首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Particle air filters used in central residential forced‐air systems are most commonly evaluated for their size‐resolved removal efficiency for particles 0.3‐10 µm using laboratory tests. Little information exists on the removal efficiency of commercially available residential filters for particles smaller than 0.3 µm or for integral measures of mass‐based aerosol concentrations (eg, PM2.5) or total number concentrations (eg, ultrafine particles, or UFPs) that are commonly used in regulatory monitoring and building measurements. Here, we measure the size‐resolved removal efficiency of 50 new commercially available residential HVAC filters installed in a recirculating central air‐handling unit in an unoccupied apartment unit using alternating upstream/downstream measurements with incense and NaCl as particle sources. Size‐resolved removal efficiencies are then used to estimate integral measures of PM2.5 and total UFP removal efficiency for the filters assuming they are challenged by 201 residential indoor particle size distributions (PSDs) gathered from the literature. Total UFP and PM2.5 removal efficiencies generally increased with manufacturer‐reported filter ratings and with filter thickness, albeit with numerous exceptions. PM2.5 removal efficiencies were more influenced by the assumption for indoor PSD than total UFP removal efficiencies. Filters with the same ratings but from different manufacturers often had different removal efficiencies for PM2.5 and total UFPs.  相似文献   

2.
This study evaluated nine ventilation and filtration systems in an unoccupied 2006 house located 250 m downwind of the I‐80 freeway in Sacramento, California. Systems were evaluated for reducing indoor concentrations of outdoor particles in summer and fall/winter, ozone in summer, and particles from stir‐fry cooking. Air exchange rate was measured continuously. Energy use was estimated for year‐round operation in California. Exhaust ventilation without enhanced filtration provided indoor PM2.5 that was 70% lower than outdoors. Supply ventilation with MERV13 filtration provided slightly less protection, whereas supply MERV16 filtration reduced PM2.5 by 97‐98% relative to outdoors. Supply filtration systems used little energy but provided no benefits for indoor‐generated particles. Systems with MERV13‐16 filter in the recirculating heating and cooling unit (FAU) operating continuously or 20 min/h reduced PM2.5 by 93‐98%. Across all systems, removal percentages were higher for ultrafine particles and lower for black carbon, relative to PM2.5. Indoor ozone was 3‐4% of outdoors for all systems except an electronic air cleaner that produced ozone. Filtration via the FAU or portable filtration units lowered PM2.5 by 25‐75% when operated over the hour following cooking. The energy for year‐round operation of FAU filtration with an efficient blower motor was estimated at 600 kWh/year.  相似文献   

3.
In this study, we explore different filter and contextual characteristics that influence effectiveness of high-efficiency filters in 21 residences in Toronto, Canada. The in situ effectiveness was assessed with decay tests at the beginning and the end of filter life with four different filters (MERV 8-14 from ASHRAE Standard 52.2) installed in operational HVAC systems, compared with either the system off or with no filter installed. There was considerable difference between median PM2.5 effectiveness of the non-electret filters when compared to electret filters (16% vs. 36%) of the same nominal efficiency (MERV 8). However, median PM2.5 effectiveness of electret filters only slightly improved (between 5% and 9% absolute increase) as MERV increased from 8 to 14. There was more variation in filter effectiveness between the same filter in different homes than there was between different filters in the same home. Variations in filter performance arose because home-specific particle loss rates (eg, ventilation rate) vary greatly in different buildings. The higher the loss rates due to non-filter factors, the lower the effectiveness of a filter. Given the relatively large variation in effectiveness for a given filter over time and in different homes, increasing system runtime may be a productive way to improve filter performance in many homes.  相似文献   

4.
We applied filter forensics, the analysis of dust from the heating, ventilation, and air-conditioning (HVAC) filters, to measure particle size distribution in 21 residences in Toronto, Canada over a year. Four filters with different nominal efficiencies (Minimum Efficiency Reporting Value (MERV) 8–14 from ASHRAE Standard 52.2) were deployed in each residence each for three months, while the effective filtration volumes (the product of flow rate, runtime, and in-situ filter efficiency) were characterized over each filter lifetime. Using extraction and laser diffraction, we found that approximately 90% of the volumetric distributions were >10 µm and the volume median diameter (VMD) ranged from 23.4 to 75.1 µm. Using quantitative filter forensics (QFF), total suspended particle (TSP) concentrations ranged from 2.9 to 823.7 µg/m3 (median = 89.8 µg/m3) with a moderate correlation with the content of TSP on the filters (in terms of g) and with the TSP effective filtration volume (m3) indicating the importance of both filter forensics and HVAC metadata parameters to QFF concentration estimates. There was no strong correlation between PM10 or PM2.5 concentrations and hourly airborne particle number concentrations measured by low-cost sensors suggesting an evaluation of QFF is warranted, particularly for the exploration of smaller particles.  相似文献   

5.
This study involved the development of a model for evaluating the potential costs and benefits of ozone control by activated carbon filtration in single‐family homes. The modeling effort included the prediction of indoor ozone with and without activated carbon filtration in the HVAC system. As one application, the model was used to predict benefit‐to‐cost ratios for single‐family homes in 12 American cities in five different climate zones. Health benefits were evaluated using disability‐adjusted life‐years and included city‐specific age demographics for each simulation. Costs of commercially available activated carbon filters included capital cost differences when compared to conventional HVAC filters of similar particle removal efficiency, energy penalties due to additional pressure drop, and regional utility rates. The average indoor ozone removal effectiveness ranged from 4 to 20% across the 12 target cities and was largely limited by HVAC system operation time. For the parameters selected in this study, the mean predicted benefit‐to‐cost ratios for 1‐inch filters were >1.0 in 10 of the 12 cities. The benefits of residential activated carbon filters were greatest in cities with high seasonal ozone and HVAC usage, suggesting the importance of targeting such conditions for activated carbon filter applications.  相似文献   

6.
The aim of this work was to assess ultrafine particles (UFP) number concentrations in different microenvironments of Portuguese preschools and to estimate the respective exposure doses of UFP for 3–5‐year‐old children (in comparison with adults). UFP were sampled both indoors and outdoors in two urban (US1, US2) and one rural (RS1) preschool located in north of Portugal for 31 days. Total levels of indoor UFP were significantly higher at the urban preschools (mean of 1.82 × 104 and 1.32 × 104 particles/cm3 at US1 an US2, respectively) than at the rural one (1.15 × 104 particles/cm3). Canteens were the indoor microenvironment with the highest UFP (mean of 5.17 × 104, 3.28 × 104, and 4.09 × 104 particles/cm3 at US1, US2, and RS1), whereas the lowest concentrations were observed in classrooms (9.31 × 103, 11.3 × 103, and 7.14 × 103 particles/cm3 at US1, US2, and RS1). Mean indoor/outdoor ratios (I/O) of UFP at three preschools were lower than 1 (0.54–0.93), indicating that outdoor emissions significantly contributed to UFP indoors. Significant correlations were obtained between temperature, wind speed, relative humidity, solar radiation, and ambient UFP number concentrations. The estimated exposure doses were higher in children attending urban preschools; 3–5‐year‐old children were exposed to 4–6 times higher UFP doses than adults with similar daily schedules.  相似文献   

7.
Analysis of the dust from heating, ventilation, and air conditioning (HVAC) filters is a promising long‐term sampling method to characterize airborne particle‐bound contaminants. This filter forensics (FF) approach provides valuable insights about differences between buildings, but does not allow for an estimation of indoor concentrations. In this investigation, FF is extended to quantitative filter forensics (QFF) by using measurements of the volume of air that passes through the filter and the filter efficiency, to assess the integrated average airborne concentrations of total fungal and bacterial DNA, 36 fungal species, endotoxins, phthalates, and organophosphate esters (OPEs) based on dust extracted from HVAC filters. Filters were collected from 59 homes located in central Texas, USA, after 1 month of deployment in each summer and winter. Results showed considerable differences in the concentrations of airborne particle‐bound contaminants in studied homes. The airborne concentrations for most of the analytes are comparable with those reported in the literature. In this sample of homes, the HVAC characterization measurements varied much less between homes than the variation in the filter dust concentration of each analyte, suggesting that even in the absence of HVAC data, FF can provide insight about concentration differences for homes with similar HVAC systems.  相似文献   

8.
Ward M  Siegel JA  Corsi RL 《Indoor air》2005,15(2):127-134
Stand-alone air cleaners may be efficient for rapid removal of indoor fine particles and have potential use for shelter-in-place (SIP) strategies following acts of bioterrorism. A screening model was employed to ascertain the potential significance of size-resolved particle (0.1-2 microm) removal using portable high efficiency particle arresting (HEPA) air cleaners in residential buildings following an outdoor release of particles. The number of stand-alone air cleaners, air exchange rate, volumetric flow rate through the heating, ventilating and air-conditioning (HVAC) system, and size-resolved particle removal efficiency in the HVAC filter were varied. The effectiveness of air cleaners for SIP was evaluated in terms of the outdoor and the indoor particle concentration with air cleaner(s) relative to the indoor concentration without air cleaners. Through transient and steady-state analysis of the model it was determined that one to three portable HEPA air cleaners can be effective for SIP following outdoor bioaerosol releases, with maximum reductions in particle concentrations as high as 90% relative to conditions in which an air cleaner is not employed. The relative effectiveness of HEPA air cleaners vs. other removal mechanisms was predicted to decrease with increasing particle size, because of increasing competition by particle deposition with indoor surfaces and removal to HVAC filters. However, the effect of particle size was relatively small for most scenarios considered here. PRACTICAL IMPLICATIONS: The results of a screening analysis suggest that stand-alone (portable) air cleaners that contain high efficiency particle arresting (HEPA) filters can be effective for reducing indoor fine particle concentrations in residential dwellings during outdoor releases of biological warfare agents. The relative effectiveness of stand-alone air cleaners for reducing occupants' exposure to particles of outdoor origin depends on several factors, including the type of heating, ventilating and air-conditioning (HVAC) filter, HVAC operation, building air exchange rate, particle size, and duration of elevated outdoor particle concentration. Maximum particle reductions, relative to no stand-alone air cleaners, of 90% are predicted when three stand-alone air cleaners are employed.  相似文献   

9.
Filters are used in heating, ventilation, and air-conditioning (HVAC) systems for both commercial and residential buildings to protect the equipment and improve indoor air quality in conditioned spaces. Although there are many benefits of using the air filter in an air-conditioning system, the resistance associated with it can increase fan energy use and may adversely affect air-conditioning system performance and efficiency. The paper explores the impact of air filtration on energy consumption for a typical air-conditioning (AC) system with constant- or variable-speed fan. A whole building simulation model is used to simulate the annual energy consumption for various air-conditioning system capacities, different levels of filter cleanliness, and various filter minimum efficiency reporting values (MERV). The results indicate that with a constant-speed fan, the cooling energy use increases as the filter gets dirty over time and the energy use in the fan may increase but this depends heavily on the investigated fan performance curve. With a variable-speed fan, the fan energy use increases with a dirty filter but the cooling and heating energy uses are slightly affected. The fan energy use rise due to the dirty filter depends mainly on air system capacities, filter MERV ratings, and the degree of the filter cleanliness.  相似文献   

10.
Continuous emission of unipolar ions has been shown to improve the performance of respirators and stationary filters challenged with non-biological particles. In this study, we investigated the ion-induced enhancement effect while challenging a low-efficiency heating, ventilation and air-conditioning (HVAC) filter with viable bacterial cells, bacterial and fungal spores, and viruses. The aerosol concentration was measured in real time. Samples were also collected with a bioaerosol sampler for viable microbial analysis. The removal efficiency of the filter was determined, respectively, with and without an ion emitter. The ionization was found to significantly enhance the filter efficiency in removing viable biological particles from the airflow. For example, when challenged with viable bacteria, the filter efficiency increased as much as four- to fivefold. For viable fungal spores, the ion-induced enhancement improved the efficiency by a factor of approximately 2. When testing with virus-carrying liquid droplets, the original removal efficiency provided by the filter was rather low: 9.09 +/- 4.84%. While the ion emission increased collection about fourfold, the efficiency did not reach 75-100% observed with bacteria and fungi. These findings, together with our previously published results for non-biological particles, demonstrate the feasibility of a new approach for reducing aerosol particles in HVAC systems used for indoor air quality control. PRACTICAL IMPLICATIONS: Recirculated air in HVAC systems used for indoor air quality control in buildings often contains considerable number of viable bioaerosol particles because of limited efficiency of the filters installed in these systems. In the present study, we investigated - using aerosolized bacterial cells, bacterial and fungal spores, and virus-carrying particles - a novel idea of enhancing the performance of a low-efficiency HVAC filter utilizing continuous emission of unipolar ions in the filter vicinity. The findings described in this paper, together with our previously published results for non-biological particles, demonstrate the feasibility of the newly developed approach.  相似文献   

11.
This study aimed to measure in French children personal exposure concentrations of black carbon (BC) and ultrafine particles (UFP) and to quantify the contribution of different microenvironments (home, school, places of extracurricular activities, transport) to their total exposure. It was conducted on 96 9‐year‐old children from the PARIS birth cohort. BC and UFP were continuously measured by portable devices (microAeth® AE51 and DiSCmini®) for a minimum of 24 hours, while participating families simultaneously filled in a space‐time‐activities‐budget questionnaire. BC exposure concentration was higher during trips (principally metro/train and bus), while UFP exposure concentration was higher during indoor activities (mainly eating at restaurants) and in trips. The most important UFP peaks were measured at home, especially during cooking. Home and school together accounted for much of the total exposure, 83.8% for BC and 85.3% for UFP. The contribution of transport to total exposure was 12.4% for BC and 9.7% for UFP, while extracurricular activities were responsible for 3.8% and 5% of the total exposure to BC and UFP, respectively.  相似文献   

12.
Q. Zhang  J. Avalos  Y. Zhu 《Indoor air》2014,24(2):190-198
This study characterized fine (PM2.5) and ultrafine particle (UFP, diameter < 100 nm) emissions from microwave popcorn and analyzed influential factors. Each pre‐packed popcorn bag was cooked in a microwave oven enclosed in a stainless steel chamber for 3 min. The number concentration and size distribution of UFPs and PM2.5 mass concentration were measured inside the chamber repeatedly for five different flavors under four increasing power settings using either the foil‐lined original package or a brown paper bag. UFPs and PM2.5 generated by microwaving popcorn were 150–560 and 350–800 times higher than the emissions from microwaving water, respectively. About 90% of the total particles emitted were in the ultrafine size range. The emitted PM concentrations varied significantly with flavor. Replacing the foil‐lined original package with a brown paper bag significantly reduced the peak concentration by 24–87% for total particle number and 36–70% for PM2.5. A positive relationship was observed between both UFP number and PM2.5 mass and power setting. The emission rates of microwave popcorn ranged from 1.9 × 1010 to 8.0 × 1010 No./min for total particle number and from 134 to 249 μg/min for PM2.5.  相似文献   

13.
Filter forensics is a promising indoor air investigation technique involving the analysis of dust which has collected on filters in central forced‐air heating, ventilation, and air conditioning (HVAC) or portable systems to determine the presence of indoor particle‐bound contaminants. In this study, we summarize past filter forensics research to explore what it reveals about the sampling technique and the indoor environment. There are 60 investigations in the literature that have used this sampling technique for a variety of biotic and abiotic contaminants. Many studies identified differences between contaminant concentrations in different buildings using this technique. Based on this literature review, we identified a lack of quantification as a gap in the past literature. Accordingly, we propose an approach to quantitatively link contaminants extracted from HVAC filter dust to time‐averaged integrated air concentrations. This quantitative filter forensics approach has great potential to measure indoor air concentrations of a wide variety of particle‐bound contaminants. Future studies directly comparing quantitative filter forensics to alternative sampling techniques are required to fully assess this approach, but analysis of past research suggests the enormous possibility of this approach.  相似文献   

14.
We measured particulate matter (PM), acrolein, and other indoor air contaminants in eight visits to grocery stores in California. Retail stores of other types (hardware, furniture, and apparel) were also sampled on additional visits. Based on tracer gas decay data, most stores had adequate ventilation according to minimum ventilation rate standards. Grocery stores had significantly higher concentrations of acrolein, fine and ultrafine PM, compared to other retail stores, likely attributable to cooking. Indoor concentrations of PM2.5 and acrolein exceeded health guidelines in all tested grocery stores. Acrolein emission rates to indoors in grocery stores had a mean estimate about 30 times higher than in other retail store types. About 80% of the indoor PM2.5 measured in grocery stores was emitted indoors, compared to only 20% for the other retail store types. Calculations suggest a substantial increase in outdoor air ventilation rate by a factor of three from current level is needed to reduce indoor acrolein concentrations. Alternatively, acrolein emission to indoors needs to be reduced 70% by better capturing of cooking exhaust. To maintain indoor PM2.5 below the California annual ambient standard of 12 μg/m3, grocery stores need to use air filters with an efficiency rating higher than the MERV 8 air filters commonly used today.  相似文献   

15.
Exposure to airborne particulate matter has a negative effect on respiratory health in both children and adults. The ultrafine fraction of particulate air pollution is of particular interest because of its increased ability to cause oxidative stress and inflammation in the lungs. We reviewed the literature, and to date findings suggest that ultrafine particles (UFPs) may play an important role in triggering asthma symptoms. Furthermore, we believe that indoor UFP exposures may be particularly important because people spend the majority of their time indoors where sources of these contaminants are often present. While several epidemiological studies have examined the respiratory effects of ambient UFP exposures, the relationship between indoor UFP exposures and childhood asthma has yet to be examined in clinical or epidemiological studies. However, the portable instrumentation necessary to conduct such investigations is increasingly available, and we expect that this issue will be addressed in the near future. Therefore, the aim of this article is to provide a general review of UFP toxicity as related to childhood asthma in order to draw attention to a potentially important public health concern. PRACTICAL IMPLICATIONS: A number of indoor sources of ultrafine particles (UFPs) have been identified, but the health effects of indoor UFP exposures remain largely unexplored. The potential respiratory effects of such exposures seem most concerning because these particles are known to cause oxidative stress and inflammation in the lungs. Subsequently, indoor UFP exposures may contribute to the exacerbation of asthma symptoms in susceptible individuals. This paper provides a review of UFP toxicity as related to childhood asthma, and to date evidence suggests that further investigation into the respiratory effects of indoor UFP exposures is warranted.  相似文献   

16.
Retail stores contain a wide range of products that can emit a variety of indoor pollutants. Among these chemicals, phthalate esters and polybrominated diphenyl ethers (PBDEs) are two important categories of semi‐volatile organic compounds (SVOCs). Filters in heating, ventilation, and air‐conditioning (HVAC) system collect particles from large volumes of air and thus potentially provide spatially and temporally integrated SVOC concentrations. This study measured six phthalate and 14 PBDE compounds in HVAC filter dust in 14 retail stores in Texas and Pennsylvania, United States. Phthalates and PBDEs were widely found in the HVAC filter dust in retail environment, indicating that they are ubiquitous indoor pollutants. The potential co‐occurrence of phthalates and PBDEs was not strong, suggesting that their indoor sources are diverse. The levels of phthalates and PBDEs measured in HVAC filter dust are comparable to concentrations found in previous investigations of settled dust in residential buildings. Significant correlations between indoor air and filter dust concentrations were found for diethyl phthalate, di‐n‐butyl phthalate, and benzyl butyl phthalate. Reasonable agreement between measurements and an equilibrium model to describe SVOC partitioning between dust and gas‐phase is achieved.  相似文献   

17.
J. Kim  K. Lee 《Indoor air》2013,23(4):318-324
The purposes of this study were to determine indoor ultrafine particle (UFP, diameter <100 nm) levels in ice rinks and to characterize UFP decay and emission rates. All 15 public ice rinks in Seoul were investigated for UFP and carbon monoxide (CO) concentrations. Three ice rinks did not show peaks in UFP concentrations, and one ice rink used two resurfacers simultaneously. High peaks of UFP and CO concentrations were observed when the resurfacer was operated. The average air change rate in the 11 ice rinks was 0.21 ± 0.13/h. The average decay rates of UFP number concentrations measured by the P‐Trak and DiSCmini were 0.54 ± 0.21/h and 0.85 ± 0.34/h, respectively. The average decay rate of UFP surface area concentration was 0.33 ± 0.15/h. The average emission rates of UFP number concentrations measured by P‐Trak and DiSCmini were 1.2 × 1014 ± 6.5 × 1013 particles/min and 3.3 × 1014 ± 2.4 × 1014 particles/min, respectively. The average emission rate of UFP surface area concentration was 3.1 × 1011 ± 2.0 × 1011 μm2/min. UFP emission rate was associated with resurfacer age. DiSCmini measured higher decay and emission rates than P‐Trak due to their different measuring mechanisms and size ranges.  相似文献   

18.
Waring MS  Siegel JA 《Indoor air》2008,18(3):209-224
The rate at which airborne particulate matter deposits onto heating, ventilation, and air-conditioning (HVAC) components is important from both indoor air quality (IAQ) and energy perspectives. This modeling study predicts size-resolved particle mass loading rates for residential and commercial filters, heat exchangers (i.e. coils), and supply and return ducts. A parametric analysis evaluated the impact of different outdoor particle distributions, indoor emission sources, HVAC airflows, filtration efficiencies, coils, and duct system complexities. The median predicted residential and commercial loading rates were 2.97 and 130 g/m(2) month for the filter loading rates, 0.756 and 4.35 g/m(2) month for the coil loading rates, 0.0051 and 1.00 g/month for the supply duct loading rates, and 0.262 g/month for the commercial return duct loading rates. Loading rates are more dependent on outdoor particle distributions, indoor sources, HVAC operation strategy, and filtration than other considered parameters. The results presented herein, once validated, can be used to estimate filter changing and coil cleaning schedules, energy implications of filter and coil loading, and IAQ impacts associated with deposited particles. PRACTICAL IMPLICATIONS: The results in this paper suggest important factors that lead to particle deposition on HVAC components in residential and commercial buildings. This knowledge informs the development and comparison of control strategies to limit particle deposition. The predicted mass loading rates allow for the assessment of pressure drop and indoor air quality consequences that result from particle mass loading onto HVAC system components.  相似文献   

19.
Children in preschools were studied as an exceptionally vulnerable group to lung diseases due to their immature immune system. Few data are available in the literature addressing the exposure of children in preschools to ultrafine (>10 nm) particles. Exposure of children to fine, ultrafine (10 nm–1 µm) particles and black carbon particles present inside and near two preschools in Nur-Sultan, Kazakhstan, during Fall 2019 was investigated. For Preschool I, the average daily (6 h) indoor (outdoor) PM1, PM2.5, and PM10 concentrations over three-week measurements were 15.0 (SD 12.5) µg/m3, 34.6 (SD 35.1) µg/m3, and 47.2 (SD 45.2) µg/m3, respectively. Average indoor UFP concentrations (>10.0 nm) including candle burning events were 5.20 × 103 (SD 8.80 × 103) particles/cm3, with the background UFP concentration to be 3.30 × 103 (SD 1.80 × 103) particles/cm3. In Preschool II, the average UFP concentration (>30.0 nm) in the morning and afternoon was 3.94 × 103 (SD 5.34 × 102) and 3.36 × 103 (SD 1.90 × 103) particles/cm3, respectively. Indoor black carbon (BC) concentrations were correlated with the outdoor smoking activity. The major sources of the indoor particles in the preschools were dust resuspension, candle burning, and infiltrated outdoor particles.  相似文献   

20.
Human exposures to ultrafine particles (UFP) are poorly characterized given the potential associated health risks. Residences are important sites of exposure. To characterize residential exposures to UFP in some circumstances and to investigate governing factors, seven single-family houses in California were studied during 2007-2009. During multiday periods, time-resolved particle number concentrations were monitored indoors and outdoors and information was acquired concerning occupancy, source-related activities, and building operation. On average, occupants were home for 70% of their time. The geometric mean time-average residential exposure concentration for 21 study subjects was 14,500 particles per cm(3) (GSD = 1.8; arithmetic mean ± standard deviation = 17,000 ± 10,300 particles per cm(3)). The average contribution to residential exposures from indoor episodic sources was 150% of the contribution from particles of outdoor origin. Unvented natural-gas pilot lights contributed up to 19% to exposure for the two households where present. Episodic indoor source activities, most notably cooking, caused the highest peak exposures and most of the variation in exposure among houses. Owing to the importance of indoor sources and variations in the infiltration factor, residential exposure to UFP cannot be characterized by ambient measurements alone. PRACTICAL IMPLICATIONS: Indoor and outdoor sources each contribute to residential ultrafine particle (UFP) concentrations and exposures. Under the conditions investigated, peak exposure concentrations indoors were associated with cooking, using candles, or the use of a furnace. Active particle removal systems can mitigate exposure by reducing the persistence of particles indoors. Eliminating the use of unvented gas pilot lights on cooking appliances could also be beneficial. The study results indicate that characterization of human exposure to UFP, an air pollutant of emerging public health concern, cannot be accomplished without a good understanding of conditions inside residences.  相似文献   