Slide valve is normally employed in screw refrigeration compressor to meet the cooling capacity demanded by the load variation. A mathematical model describing the working process of screw refrigeration compressor with a slide valve assembly under part-load conditions is established based on the calculation of the effective by-pass area and radial discharge area. Experimental investigation on a screw refrigeration compressor under part-load conditions with several evaporation and condensation temperatures is also carried out. Simulation results are in good agreement with the experimental ones. With the validated model, effects of key design parameters, i.e. the installation angles of the slide valve relative to the cylinder and the slide stop length, on the working process and performance of screw refrigeration compressor have been analyzed. These results can be useful for optimum design of the slide valve assembly to improve the energy efficiency of refrigeration system with screw compressor under part-load conditions.  相似文献   

2.
The performance of CO2 refrigeration systems strongly depends on the operating conditions. The specific characteristics of low critical temperature and high operating pressure limit its applications and imply the implementation of different control strategies. This study compares the performance of different CO2 system solutions for supermarket refrigeration with R404A system. Some possible modifications and improvements on the CO2 system have been investigated. The COP of the investigated CO2 system solution can be improved by about 3–7% along the ambient temperature range of 10–40 °C. The annual energy consumption calculations in three different climates; cold, moderate and hot, show that the centralized trans-critical CO2 system is good solution for cold climates whereas the NH3–CO2 cascade system has the lowest energy consumption in hot climates. Both systems proved to be good alternatives to R404A DX system for supermarket refrigeration.  相似文献   

3.
The purpose of this paper is to present a local stability analysis of an endoreversible refrigerator operating at the minimum input power P for given cooling load R absorbed from the cold reservoir, for different thermal conductances α and β, in the isothermal couplings of the working fluid with the heat reservoirs TH and TL (TH>TL). An endoreversible refrigerator system that is modeled by the differential equation may depend on the numerical values of certain parameters that appear in the equation. From the local stability analysis we find that a critical point of an almost linear system is a stable node. After a small perturbation the system state exponentially decays to steady state with either of two relaxation times that are a function of α, β, TL, R and the heat capacity C. We can exhibit qualitatively the behavior of solutions of the system by sketching its phase portrait. One eigenvector in a phase portrait is the nonzero constant vector, and the other is a function of α, β, R, TH and TL. Finally, we discuss the local stability and energetic properties of the endoreversible refrigerator.  相似文献   

4.
Optimisation is a design method to search the best value of the defined system's goal that can be expressed by an objective function to be minimised or maximised. A set of unknowns subject to constraints controls the values that the objective function can assume. A multi-variable approach enables one to address the optimisation of a thermodynamic system: the best working conditions of the system are different from those corresponding to component optimisation. Then we have to model the complete system to find an optimumty.

Different objective functions are presented as optimisation criteria of the design data of a steam ejector cycle, keeping the same boundary conditions and convergence limits and using a numerical optimisation of the cycle published by the authors. The comparison between the results obtained with different objective functions is presented to show the influence of the function chosen on the system design.

The comparison also shows that the choice of the objective function decisively influences the robustness of the numerical code results and the convergence performances of the code.  相似文献   


5.
On the basis of classical Langevin theory along with statistical mechanics, thermodynamics and magnetism, a new expression of magnetocaloric parameters used for room temperature magnetic refrigeration is proposed, which is briefer and more accurate than the existing one, providing a new way for studying performance of regenerative room temperature magnetic Ericsson refrigeration cycle. Influences of temperature of heat reservoirs and magnetic intensity on cycle refrigeration capacity and coefficient of performance are analyzed. The results show that the maximal temperature span of the cycle increases but its increasing rate decreases with the increase of magnetic field strength. In addition, there exists only one maximum value of effective refrigerating capacity. Two cycles with the same COP can reach a same temperature span under a certain magnetic field strength. A large magnetic field strength can improve COP but the increase rate of COP decreases.  相似文献   

6.
In this article, a special configuration of Stirling refrigerator for domestic refrigeration purpose is introduced. A thermal buffer tube is installed between the refrigerator cold-end and the expansion piston to improve the system reliability by moving the expansion piston from low temperature to ambient temperature. Furthermore, a commercial oil-lubricated dual-piston compressor is modified to drive the refrigerator, inside which an elastic membrane is used to transfer acoustic work and separate the working gas of the refrigerator from that of the compressor. Experimental investigations on the refrigerator are performed using helium as the working fluid and a cooling power of 200 W at −78 °C is achieved at 15 Hz working frequency and 2.5 MPa mean pressure. Meanwhile, a rough estimation of the refrigerator COP in terms of cooling power divided by input acoustic power gives the value of 0.64. It gives the possibility of building a low-cost, high efficiency domestic refrigerator.  相似文献   

7.
In this work a model of a vapour compression refrigeration system with a variable-speed compressor, based on a black-box modelling technique, is presented. The kernel of the model consists of a full customized radial basis function network, which has been developed to accurately predict the performance of the system with low cost data requirement in terms of input variables and training data. The work also presents a steady state validation of the model inside and outside the training data set, finding, in both cases, a good agreement between experimental values and those predicted by the model. These results constitute a first step to go through future research on fault detection and energy optimisation in variable-speed refrigeration systems.  相似文献   

8.
Some complex refrigeration and heat pump systems with several condensers and evaporators have been developed for different kinds of application. Traditional simulation models were developed for systems in certain operating modes and they failed in modeling the complex refrigeration systems with uncertainties of heat exchangers function and refrigerant flowing direction. In order to predict the performance of complex refrigeration systems, a simulation model is presented based on the two-phase fluid network. The model is consisted of distributed-parameter model of heat exchangers and connecting tubes, map-based model of inverter compressor and electronic expansion valve (EEV). Based on the characteristic of refrigeration system and fluid network, the three conservation equations, i.e. energy, momentum and mass equations, are solved iteratively. This model can deal with the uncertainty of refrigerant flow direction by separating the solving process of the components and the fluid network model, and therefore can simulate different kinds of complex refrigeration systems in different operating modes and conditions. The model is validated by the experimental data of an inverter air conditioner in heating/cooling operating modes and it shows the error of the model is mainly determined by the error of submodels of components in calculating heat transfer and pressure loss. The model is applied for performance analysis of three kinds of complex refrigeration systems in the accompanying article [Shi W.X., Shao, S.Q., Li, X.T., Yan, Q.S., 2008. Simulation model for complex heat pump systems based on two-phase fluid network: part II – model applications, International Journal of Refrigeration 31 (3), 500–509.].  相似文献   

9.
A simulation model of complex refrigeration system based on two-phase fluid network is developed in part I of the paper [Shao, S.Q., Shi, W.X., Li, X.T., Yan, Q.S., 2008. Simulation model for complex heat pump systems based on two-phase fluid network – part I: model development. International Journal of Refrigeration 31 (3), 490–499.]. One same fluid network is used in the model to describe the refrigeration system in different operating modes with the method of the factual and fictitious branches. When there are many heat exchangers with concurrent cooling and heating, the traditional models are not able to define the flowing directions. The developed model, however, whether the initial flowing direction of the connecting branches is right or not, is able to predict the flow and heat transfer. Three typical complex refrigeration systems such as the multi-unit inverter air conditioner, heat pump with domestic hot water and multi-unit heat pump dehumidifier are simulated with the developed model as demonstrations on how to use it. The model can evaluate the influences of one or more parameters on the system performance, which can be used for the optimization of the system by all-condition performance analysis. It is shown that the two-phase fluid network model is effective and convenient for the simulation of different complex refrigeration system, especially for performance analysis, system evaluation, and optimization based on the performance prediction.  相似文献   

10.
A numerical and experimental comparative study of a carbon dioxide trans-critical refrigerating system and a conventional sub-critical refrigerating cycle is presented. Attention is focussed not only on the whole refrigeration cycle, but also on the behaviour of the hermetic reciprocating compressors used in these systems. The comparative cases presented have been specially designed for small cooling capacity units with an evaporation temperature around 0 °C. A detailed numerical simulation model for hermetic reciprocating compressors performance, widely validated under conventional fluid refrigerants, has been extended to numerically obtain the CO2 compressor prototypes behaviour. Two CO2 compressor prototypes working with CO2 have been experimentally tested in a specific unit, specially designed and built to analyse high-pressure single stage vapour compression trans-critical refrigerating equipments. This set-up has allowed validating a detailed numerical simulation code for the thermal and fluid-dynamic behaviour of single stage vapour compression refrigeration system working with CO2 as fluid refrigerant. The numerical results and the experimental data obtained to validate compressors, heat exchangers and whole cycle behaviour have shown a really good agreement. Finally, the numerical and experimental comparison between the carbon dioxide system and the sub-critical conventional cycle has shown the possibility of CO2 as fluid refrigerant under the studied working conditions.  相似文献   

11.
Using CO2 trans-critical system solutions in supermarket refrigeration is gaining interest with several installations already running in different European countries. Using a computer simulation model, this study investigates the performance of two main system solutions: centralized with accumulation tank at the medium temperature level and parallel with two separate circuits for low and medium temperature levels. Both system solutions are presented and the simulation model is described in details. Calculations have been performed to design the systems and optimize their performances where basic layout and size of each solution have been defined. For ambient temperature range of 10–40 °C, the reference centralized system solution shows higher COP of about 4–21% than the reference parallel solution. Using two-stage compression in the centralized system solution instead of single stage will result in total COP which is about 5–22% higher than that of the reference centralized system and 13–17% higher than that of the improved two-stage parallel system. The two-stage centralized system solution gives the highest COP for the selected ambient temperature range.  相似文献   

12.
The performance of a twin screw compressor operating under wet (two-phase) compression conditions in an ammonia–water compression absorption heat pump cycle is investigated both theoretically and experimentally. The paper reports on the influence of the location of liquid intake or, depending what applies, injection angle and mass flow rate of the injected liquid on compressor performance. Labyrinth seals separate the oil-free process side from oil lubricated bearing housing. Labyrinth seals leakage is modelled and its impact on performance is theoretically and experimentally investigated. The need for liquid injection from the discharge side to obtain acceptable performance is discussed based on experimental results.  相似文献   

13.
14.
A previously developed one-dimensional model, based on a forward marching solution technique of the conservation equations has been used to study ejector operation and performance in a large range of refrigeration working conditions. Several important features of ejector operation characteristics were simulated. Global parameter values, their local distributions along the ejector including the temperature, the pressure and the Mach number were calculated for design and off design conditions. Operation parameters such as the entrainment ratio ω, compression ratios Pexit/Pev, Pg/Pexit and the geometric ratio (D/Dc)2 were found to significantly affect performance. The impact of the generator, the evaporator, the condenser and related thermodynamic parameters, which have been assessed in this study, are summarized as:
Fluid mixing conditions dictated by the fluid type, the mixing chamber geometry, the inlet and outlet constraints, may lead to off design operation with related stability and performance deterioration

Internal superheat generation, due to inefficient mixing and normal shock waves is very important in off design operation

Some degree of inlet superheat (around 5 °C) is necessary to prevent internal condensation but excess superheat is detrimental to the condenser efficiency at exit

Generator pressure conditions and the evaporator temperature significantly affect ejector performance.

Keywords: Refrigerating system; Ejector system; Modelling; Ejector; Parameter; Geometry; Performance

Mots clés: Système frigorifique; Système à éjecteur; Modélisation; Ejecteur; Paramètre; Géométrie; Performance  相似文献   


15.
Capillary tubes have been used in refrigeration systems for many years, but not with a transcritical CO2 system. In this article, the effects of capillary tubes in a transcritical CO2 refrigeration system have been investigated experimentally and theoretically. Different types of capillary tubes with different lengths (0.5–4 m) and diameters (1–2 mm) have been tested. The result of this work is a static model, which is used in the further work to make a simulation model (static) of a complete refrigeration system. The model is based on Friedel's and Colebrook's pressure drop correlations.

The behaviour of an adiabatic capillary tube in a refrigeration cycle has been investigated theoretically. The conclusion is that the COP of a system with capillary tubes generally is better than when a fixed high pressure is used, but not as good as when variable optimal high pressure is used. Capillary tubes are especially interesting in applications where the evaporation pressure is constant and the temperature out of the gas cooler varies no more than ±10 K from the design condition. The reduction in COP is more significant at low temperatures out of the gas cooler.  相似文献   


16.
The aim of this paper is to investigate, both experimentally and theoretically, the potential of improving the cycle efficiency through two stage compression with intermediate cooling, at operating conditions typical of air conditioning. The experimental set-up consists of two closed loop air circuits acting as heat sink and heat source for gas-cooler and evaporator, respectively. The tested refrigerating circuit includes two tube-and-fin heat exchangers as gas-cooler and evaporator, a back-pressure valve as throttling device and a double-stage semi-hermetic compound, two-piston, reciprocating compressor equipped with oil separator and intercooler. A full set of thermocouples, pressure transducers and flow-meters allows measurement of all the main parameters of the CO2 cycle, enabling to perform heat balance both air and refrigerant side. Tests were run at fixed evaporation pressure, evaporator outlet superheating and gas-cooler outlet temperature, varying the gas-cooler outlet pressure in the range 8–11 MPa. The optimal gas-cooler pressure for this application as well as the effect of the intercooler efficiency on the cycle performance were investigated.

A FORTRAN code for the simulation of an improved two-stage cycle was validated against the experimental results; a theoretical analysis performed with this code is proposed for optimisation and energy performance evaluation of such a cycle.  相似文献   


17.
Conventional working fluids (refrigerants) are being phased out worldwide to combat with the twin menace of ozone layer depletion and global warming and natural refrigerants are fast gaining favour lately. Single stage and multi stage refrigeration systems fail to widen the gap between heat source and heat sink temperatures required in many industrial applications requiring simultaneous heating and cooling and cascaded systems appear to be the best alternative. Modest research has been done in cascaded systems based on natural refrigerants thereby offering good potential for research. In this paper, a cascaded system for simultaneous heating and cooling (refrigeration and heat pump system) with a carbon dioxide based HT cycle and propane based LT cycle for simultaneous refrigeration and heating applications has been analyzed. To facilitate prediction of optimum performance parameters, performance trends with variation in the design parameters and operating variables have been presented in this article. Relevant expressions have been developed to serve as guidelines to the user for selecting appropriate design parameters like intermediate temperature so that the system yields optimum performance. Independently developed property codes have been employed for both carbon dioxide and propane for higher accuracy.  相似文献   

18.
The system performance of a CO2 refrigeration system is greatly affected by the compressor discharge pressure. An internal heat exchanger (IHX) with high effectiveness is an important factor to achieve high system performance. The expression traditionally used to describe the heat exchange effectiveness is not suitable for CO2 systems. As a result a practical effectiveness expression for IHX, based on enthalpy difference, has been derived and is reported in this paper. Detailed analysis on the relationship between the optimum high pressure Pk,opt and other systematic parameters was performed. Evaporating temperature has little influence on Pk,opt; and IHX can minimize the sensitivity of the system to the refrigerant quality x at the evaporator outlet. Based on simulation data, a correlation of Pk,opt was developed that predicts the simulation values with a deviation of less than 3.6% in the whole range and 0.94% when the evaporating temperature t1=5.3 °C. The results reported in this paper can be used in optimum control and performance evaluation of the whole system.  相似文献   

19.
This paper describes the experiment carried out to analyze the performance of a refrigeration system in cascade with ammonia and carbon dioxide as working fluids. The effect of operation parameters, such as the evaporating temperature of the low temperature cycle, the condensing temperature of low temperature cycle, temperature difference in cascade heat exchanger and superheat degree, on the system performance was investigated. Performance of the cascade system with NH3/CO2 was compared with that of two-stage NH3 system and single-stage NH3 system with or without economizer. It was found that the COP of the cascade system is the best among all the systems, when the evaporating temperature is below −40 °C. Also, the cascade system performance is greatly affected by evaporating temperature, condensing temperature of low temperature cycle, temperature difference in cascade heat exchanger and is only slightly sensitive to superheat degree. All the experimental results indicate that the NH3/CO2 cascade system is very competitive in low temperature applications.  相似文献   

20.
For some years, European regulation concerning refrigerating systems has become more and more severe. Because of their design and technology, refrigeration units cannot avoid refrigerant leaks, and can thus have a harmful impact on the environment. Many studies aimed at minimizing the charge in a refrigerating machine were thus developed. On a global level, reduction of refrigerant charges must not affect energy aspects while respecting environmental constraints [Montreal 1987, Kyoto 1997]. The architecture and refrigerant charge distribution in the systems are of particular importance; their analyses permit the determination of the target elements and thus define those in which the refrigerant charge could be reduced (heat exchangers, liquid pipes, receivers, …). This paper presents a review of the refrigerant charge studies in a refrigerating plant (methodologies of charge measurement, void fraction correlations and characteristic values for various technologies). It also evaluates the influence of the refrigerant charge on the coefficient of performance (COP) and on the cooling capacity. Finally, it inventories the different means that allow the charge in a refrigerating system to be minimized.  相似文献   