首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Simultaneously generating both electricity and low grade heat, photovoltaic thermal (PVT) systems maximise the solar energy extracted per unit of collector area and have the added benefit of increasing the photovoltaic (PV) electrical output by reducing the PV operating temperature. A graphical representation of the temperature rise and rate of heat output as a function of the number of transfer units NTUs illustrates the influence of fundamental parameter values on the thermal performance of the PVT collector. With the aim of maximising the electrical and thermal energy outputs, a whole of system approach was used to design an experimental, unglazed, single pass, open loop PVT air system in Sydney. The PVT collector is oriented towards the north with a tilt angle of 34°, and used six 110 Wp frameless PV modules. A unique result was achieved whereby the additional electrical PV output was in excess of the fan energy requirement for air mass flow rates in the range of 0.03–0.05 kg/s m2. This was made possible through energy efficient hydraulic design using large ducts to minimise the pressure loss and selection of a fan that produces high air mass flow rates (0.02–0.1 kg/s m2) at a low input power (4–85 W). The experimental PVT air system demonstrated increasing thermal and electrical PV efficiencies with increasing air mass flow rate, with thermal efficiencies in the range of 28–55% and electrical PV efficiencies between 10.6% and 12.2% at midday.  相似文献   

2.
The work presented in this article aims to investigate a PV/T hybrid solar window on a system level. A PV/T hybrid is an absorber on which solar cells have been laminated. The solar window is a PV/T hybrid collector with tiltable insulated reflectors integrated into a window. It simultaneously replaces thermal collectors, PV-modules and sunshade. The building integration lowers the total price of the construction since the collector utilizes the frame and the glazing in the window. When it is placed in the window a complex interaction takes place. On the positive side is the reduction of the thermal losses due to the insulated reflectors. On the negative side is the blocking of solar radiation that would otherwise heat the building passively. This limits the performance of the solar window since a photon can only be used once. To investigate the sum of such complex interaction a system analysis has to be performed. In this paper results are presented from such a system analysis showing both benefits and problems with the product. The building system with individual solar energy components, i.e. solar collector and PV modules, of the same size as the solar window, uses 1100 kW h less auxiliary energy than the system with a solar window. However, the solar window system uses 600 kW h less auxiliary energy than a system with no solar collector.  相似文献   

3.
Solar photovoltaic (PV) hybrid system technology is a hot topic for R&D since it promises lot of challenges and opportunities for developed and developing countries. The Kingdom of Saudi Arabia (KSA) being endowed with fairly high degree of solar radiation is a potential candidate for deployment of PV systems for power generation. Literature indicates that commercial/residential buildings in KSA consume an estimated 10–45% of the total electric energy generated. In the present study, solar radiation data of Dhahran (East-Coast, KSA) have been analyzed to assess the techno-economic viability of utilizing hybrid PV–diesel–battery power systems to meet the load requirements of a typical commercial building (with annual electrical energy demand of 620,000 kW h). The monthly average daily solar global radiation ranges from 3.61 to 7.96 kW h/m2. NREL's HOMER software has been used to carry out the techno-economic viability. The simulation results indicate that for a hybrid system comprising of 80 kWp PV system together with 175 kW diesel system and a battery storage of 3 h of autonomy (equivalent to 3 h of average load), the PV penetration is 26%. The cost of generating energy (COE, US$/kW h) from the above hybrid system has been found to be 0.149 $/kW h (assuming diesel fuel price of 0.1 $/L). The study exhibits that for a given hybrid configuration, the operational hours of diesel generators decrease with increase in PV capacity. The investigation also examines the effect of PV/battery penetration on COE, operational hours of diesel gensets for a given hybrid system. Emphasis has also been placed on unmet load, excess electricity generation, percentage fuel savings and reduction in carbon emissions (for different scenarios such as PV–diesel without storage, PV–diesel with storage, as compared to diesel-only situation), cost of PV–diesel–battery systems, COE of different hybrid systems, etc.  相似文献   

4.
The burning of depleting fossil fuels for power generation has detrimental impact on human life and climate. In view of this, renewable solar energy sources are being increasingly exploited to meet the energy needs. Moreover, solar photovoltaic (PV)–diesel hybrid system technology promises lot of opportunities in remote areas which are far from utility grid and are driven by diesel generators. Integration of PV systems with the diesel plants is being disseminated worldwide to reduce diesel fuel consumption and to minimize atmospheric pollution. The Kingdom of Saudi Arabia (K.S.A.) being endowed with high intensity of solar radiation, is a prospective candidate for deployment of PV systems. Also, K.S.A. has large number of remote scattered villages. The aim of this study is to analyze solar radiation data of Rafha, K.S.A., to assess the techno-economic feasibility of hybrid PV–diesel–battery power systems to meet the load requirements of a typical remote village Rawdhat Bin Habbas (RBH) with annual electrical energy demand of 15,943 MWh. Rafha is located near RBH. The monthly average daily global solar radiation ranges from 3.04 to 7.3 kWh/m2. NREL's HOMER software has been used to perform the techno-economic evaluation. The simulation results indicate that for a hybrid system composed of 2.5 MWp capacity PV system together with 4.5 MW diesel system (three 1.5 MW units) and a battery storage of 1 h of autonomy (equivalent to 1 h of average load), the PV penetration is 27%. The cost of generating energy (COE, US$/kWh) from the above hybrid system has been found to be 0.170$/kWh (assuming diesel fuel price of 0.1$/l). The study exhibits that the operational hours of diesel generators decrease with increase in PV capacity. The investigation also examines the effect of PV/battery penetration on COE, operational hours of diesel gensets. Concurrently, emphasis has been placed on: un-met load, excess electricity generation, percentage fuel savings and reduction in carbon emissions (for different scenarios such as: PV–diesel without storage, PV–diesel with storage, as compared to diesel-only situation), COE of different hybrid systems, etc. The decrease in carbon emissions by using the above hybrid system is about 24% as compared to the diesel-only scenario.  相似文献   

5.
The advantage of PV–thermal hybrid systems is their high total efficiency. By using concentrating hybrid systems, the cost per energy produced is reduced due to simultaneous heat and electricity production and a reduced PV cell area. In this article, the optical efficiency of a water-cooled PV–thermal hybrid system with low concentrating aluminium compound parabolic concentrators is discussed. The system was built in 1999 in Älvkarleby, Sweden (60.5° N, 17.4° E) with a geometric concentration ratio of C=4 and 0.5 kWp electric power. The yearly output is 250 kWh of electricity per square metre solar cell area and 800 kWh of heat at low temperatures per square metre solar cell area. By using numerical data from optical measurements of the components (glazing, reflectors, and PV cells) the optical efficiency, ηopt, of the PV–CPC system has been determined to be 0.71, which is in agreement with the optical efficiency as determined from thermal and electrical measurements. Calculations show that optimised antireflection-treated glazing and reflectors could further increase the electric power yield.  相似文献   

6.
Photovoltaic technology provides the direct method to convert solar energy into electricity. Modeling and simulation plays a very important role in the development of PV devices as well as in the design of PV systems. The objective of the current work was to develop a novel thermal model to simulate the thermal performance of PV modules with and without cooling. The model was sequentially coupled with a radiation model and an electrical model to calculate the electrical performance of the PV panels. Using the developed model, various studies were performed to evaluate the electrical and thermal performance of the module under different environmental and operating conditions with and without cooling. Results show that the performance of the PV panel with cooling had very little influence of increasing absorbed radiation (200–1000 W/m2) at a constant ambient temperature (25 °C) and increasing ambient temperature (0–50 °C) at an absorbed radiation of 800 W/m2. For the same variation in conditions, the performance of the panel without any cooling reduced significantly.  相似文献   

7.
In this paper, a study is carried out to evaluate the annual thermal and exergy performance of a photovoltaic/thermal (PV/T) and earth air heat exchanger (EAHE) system, integrated with a greenhouse, located at IIT Delhi, India, for different climatic conditions of Srinagar, Mumbai, Jodhpur, New Delhi and Bangalore. A comparison is made of various energy metrics, such as energy payback time (EPBT), electricity production factor (EPF) and life cycle conversion efficiency (LCCE) of the system by considering four weather conditions (a–d type) for five climatic zones. The embodied energy and annual energy outputs have been used for evaluation of the energy metrics. The annual overall thermal energy, annual electrical energy savings and annual exergy was found to be best for the climatic condition of Jodhpur at 29,156.8 kWh, 1185 kWh and 1366.4 kWh, respectively when compared with other weather stations covered in the study, due to higher solar intensity I and sunshine hours, and is lowest for Srinagar station. The results also showed that energy payback time for Jodhpur station is lowest at 16.7 years and highest for Srinagar station at 21.6 years. Electricity production factor (EPF) is highest for Jodhpur, i.e. 2.04 and Life cycle conversion efficiency (LCCE) is highest for Srinagar station. It is also observed that LCCE increases with increase in life cycle.  相似文献   

8.
This paper presents the numerical modeling and optimization of a spectrum splitting photovoltaic–thermoelectric (PV–TE) hybrid system. In this work, a simulation model is established in consideration of solar concentration levels and several heat dissipation rates. Exemplarily, the performance of a hybrid system composed of a GaAs solar cell and a skutterudites CoSb3 solar thermoelectric generator (TEG) is simulated. Analysis under different conditions has been carried out to evaluate the electrical and thermal performance of the hybrid system. Results show that the cutoff-wavelength of the GaAs–CoSb3 hybrid system is mainly determined by the band gap of solar cell, when the solar concentration ratio is ranged between 550 to 770 and heat transfer coefficient h = 3000–4500 W/m2 K, the hybrid system has good electrical performance and low operating temperatures. Based on the analysis of the GaAs–CoSb3 hybrid system, guidelines for the PV–TE system design are proposed. It is also compared with a PV-only system working under the same cooling condition; results show that the PV–TE hybrid system is more suitable for working under high concentrations.  相似文献   

9.
While many remote water pumping systems exist (e.g. mechanical windmills, solar photovoltaic, wind-electric, diesel powered), few combine both the wind and solar energy resources to possibly improve the reliability and the performance of the system. In this paper, off-grid wind turbine (WT) and solar photovoltaic (PV) array water pumping systems were analyzed individually and combined as a hybrid system. The objectives were to determine: (1) advantages or disadvantages of using a hybrid system over using a WT or a solar PV array alone; (2) if the WT or solar PV array interfered with the output of the other; and (3) which hybrid system was the most efficient for the location. The WT used in the analysis was rated at 900 W alternating current (AC). There were three different solar PV arrays analyzed, and they were rated at 320, 480, and 640 W direct current (DC). A rectifier converted the 3-phase variable voltage AC output from the WT to DC before combining it with the solar PV array DC output. The combined renewable energies powered a single helical pump. The independent variable used in the hybrid WT/PV array analysis was in units of W/m2. The peak pump efficiency of the hybrid systems at Bushland, TX occurred for the 900 W WT combined with the 640 W PV array. The peak pump efficiencies at a 75 m pumping depth of the hybrid systems were: 47% (WT/320 W PV array), 51% (WT/480 W PV array), and 55% (WT/640 W PV array). Interference occurred between the WT and the different PV arrays (likely due to voltage mismatch between WT and PV array), but the least interference occurred for the WT/320 W PV array. This hybrid system pumped 28% more water during the greatest water demand month than the WT and PV systems would have pumped individually. An additional controller with a buck/boost converter is discussed at end of paper for improvement of the hybrid WT/PV array water pumping system.  相似文献   

10.
The purpose of this work consists in thermodynamic modeling of hybrid photovoltaic–thermal (PV/T) solar systems, pursuing a modular strategy approach provided by Simulink/Matlab.PV/T solar systems are a recently emerging solar technology that allows for the simultaneous conversion of solar energy into both electricity and heat. This type of technology present some interesting advantages over the conventional “side-by-side” thermal and PV solar systems, such as higher combined electrical/thermal energy outputs per unit area, and a more uniform and aesthetical pleasant roof area. Despite the fact that early research on PV/T systems can be traced back to the seventies, only recently it has gained a renewed impetus. In this work, parametric studies and annual transient simulations of PV/T systems are undertaken in Simulink/Matlab. The obtained results show an average annual solar fraction of 67%, and a global overall efficiency of 24% (i.e. 15% thermal and 9% electrical), for a typical four-person single-familiar residency in Lisbon, with p-Si cells, and a collector area of 6 m2. A sensitivity analysis performed on the PV/T collector suggests that the most important variable that should be addressed to improve thermal performance is the photovoltaic (PV) module emittance. Based on those results, some additional improvements are proposed, such as the use of vacuum, or a noble gas at low-pressure, to allow for the removal of PV cells encapsulation without air oxidation and degradation, and thus reducing the PV module emittance. Preliminary results show that this option allows for an 8% increase on optical thermal efficiency, and a substantial reduction of thermal losses, suggesting the possibility of working at higher fluid temperatures. The higher working temperatures negative effect in electrical efficiency was negligible, due to compensation by improved optical properties. The simulation results are compared with experimental data obtained from other authors and perform reasonably well.The Simulink modeling platform has been mainly used worldwide on simulation of control systems, digital signal processing and electric circuits, but there are very few examples of application to solar energy systems modeling. This work uses the modular environment of Simulink/Matlab to model individual PV/T system components, and to assemble the entire installation layout. The results show that the modular approach strategy provided by Matlab/Simulink environment is applicable to solar systems modeling, providing good code scalability, faster developing time, and simpler integration with external computational tools, when compared with traditional imperative-oriented programming languages.  相似文献   

11.
Rustu Eke  Ali Senturk 《Solar Energy》2012,86(9):2665-2672
In the present study, performance results of two double axis sun tracking photovoltaic (PV) systems are analyzed after one year of operation. Two identical 7.9 kWp PV systems with the same modules and inverters were installed at Mugla University campus in October 2009. Measured data of the PV systems are compared with the simulated data. The performance measurements of the PV systems were carried out first when the PV systems were in a fixed position and then the PV systems were controlled while tracking the sun in two axis (on azimuth and solar altitude angles) and the necessary measurements were performed. Annual PV electricity yield is calculated as 11.53 MW h with 1459 kW h/kWp energy rating for 28 fixed tilt angle for each system. It is calculated that 30.79% more PV electricity is obtained in the double axis sun-tracking system when compared to the latitude tilt fixed system. The annual PV electricity fed to grid is 15.07 MW h with 1908 kW h/kWp for the double axis sun-tracking PV system between April-2010 and March-2011. The difference between the simulated and measured energy values are less than 5%. The results also allow the comparison of different solutions and the calculation of the electricity output.  相似文献   

12.
Photovoltaic-thermal collectors (or PV-T collector) are hybrid collectors where PV modules are integrated as an absorber of a thermal collector in order to convert solar energy into electricity and usable heat at the same time. In most of the cases, the hybrid collectors are made by the superposition of a PV module on the thermal absorber of a solar collector. In this paper, the approach is different and is to analyze thermal and optical properties related to both PV and solar thermal functions in order to identify an optimum combination leading to a maximum overall efficiency. Indeed, although these two functions do not exploit the same range of radiation wavelengths, thermal and PV functions are not so complementary due to photo-conversion thermal dependency. In this context, an alternative PV cell lamination has been developed with increased optical and thermal performance. The improvements were evaluated around 2 mA/cm2 in terms of current density in comparison to a standard module encapsulation. Based on this technique, a real size PV-T module has been built and tested at Fraunhofer solar test facilities. The results show a global efficiency of the PV-T collector above 87% (79% thermal efficiency plus 8.7% electrical efficiency, based on the absorber area).  相似文献   

13.
Rapid urbanization is increasing the amount of hilly communities around many large cities; therefore, saving water pumping energy deserves significant priority. This work proposes optimized rooftop rainwater harvesting systems (RRWHSs) and provides an energy-saving approach for hilly communities. The most cost-effective rainwater tank volumes for different dwelling types are calculated using marginal analysis. The case study at Hua-Chan Community in northern Taiwan indicates that the optimum rainwater tank volumes range from 5 m3 to 10 m3 according to the type of dwelling. The results also reveal that rainwater harvesting becomes economically feasible when both energy and water savings are addressed together. Furthermore, the cost of unit energy saving from RRWHSs is lower than that from solar PV systems. Hence, RRWHSs provide not only water savings, but also as an alternative renewable energy-saving approach to address the water–energy dilemma caused by the ever-growing hilly communities.  相似文献   

14.
Pico-hydro (pH) and photovoltaic (PV) hybrid systems incorporating a biogas generator have been simulated for remote villages in Cameroon using a load of 73 kWh/day and 8.3 kWp. Renewable energy systems were simulated using HOMER, the load profile of a hostel in Cameroon, the solar insolation of Garoua and the flow of river Mungo. For a 40% increase in the cost of imported power system components, the cost of energy was found to be either 0.352 €/kWh for a 5 kW pico-hydro generator with 72 kWh storage or 0.396 €/kWh for a 3 kWp photovoltaic generator with 36 kWh storage. These energy costs were obtained with a biomass resource cost of 25 €/tonne. The pH and PV hybrid systems both required the parallel operation of a 3.3 kW battery inverter with a 10 kW biogas generator. The pH/biogas/battery systems simulated for villages located in the south of Cameroon with a flow rate of at least 92 l/s produced lower energy costs than PV/biogas/battery systems simulated for villages in the north of Cameroon with an insolation level of at least 5.55 kWh/m2/day. For a single-wire grid extension cost of 5000 €/km, operation and maintenance costs of 125 €/yr/km and a grid power price of 0.1 €/kWh, the breakeven grid extension distances were found to be 12.9 km for pH/biogas/battery systems and 15.2 km for PV/biogas/battery systems respectively. Investments in biogas based renewable energy systems could thus be considered in the National Energy Action Plan of Cameroon for the supply of energy to key sectors involved in poverty alleviation.  相似文献   

15.
16.
Australia is a country with a vast amount of natural resources including sun and wind. Australia lies between latitude of 10–45°S and longitude of 112–152°E, with a daily solar exposure of between less than 3 MJ/(m2 day) in winter and more than 30 MJ/(m2 day) in summer.Global solar radiation in Australia varies between minimum of 3285 MJ/(m2 year) in Hobart to 8760 MJ/(m2 year) in Northern Territory. As a result of this wide range of radiation level there will be a big difference between costs of solar PV electricity in different locations.A study we have recently conducted on the solar PV electricity price in all states of Australia. For this purpose we have developed an economical model and a computer simulation to determine the accurate unit price of grid-connected roof-top solar photovoltaic (PV) electricity in A$/kWh for all state of Australia. The benefit of this computer simulation is that we can accurately determine the most appropriate feed-in tariff of grid-connected solar PV energy system. The main objective of this paper is to present the results of this study.A further objective of this paper is to present the details of the unit price of solar PV electricity in the state of Victoria in each month and then to compare with electricity price from conventional power systems, which is currently applied to this state. The state Victoria is located south of Australia and in terms of sun radiation is second lowest compared with the other Australian states.The computer simulation developed for this study makes it possible to determine the cost of grid-connected solar PV electricity at any location in any country based on availability of average daily solar exposure of each month as well as economical factors of the country.  相似文献   

17.
18.
A hybrid system design integrating a thermoelectric (TE) module has recently represented the advanced photovoltaic (PV) prototype with promoted efficiency for utilizing solar energy from the surroundings. Our present work during development of such a hybrid PV/TE system evaluates the thermal behaviors and the cooling performance associated with when integrating TE and heat sink modules. It has been noticed that a more effective structure through combining a heat sink with a TE module profits heat dissipation by cooling down the whole cell by ~ 8 °C, wherein the TE module itself demonstrates the cooling performance by ~ 27% enhancement in addition to its conventional role for electricity generation. Therefore, the PV/TE with a proper design can be used as a passive method for improving the cell efficiency as well as alleviating hot spot, which is typically occurring when the cell is unevenly heated during its operation. These results could be useful for further advancement on stability of power generation of a hybrid PV/TE system and may also be important for developing high-powered light emit diode.  相似文献   

19.
Investigating the complicated thermal physics mechanisms of the parabolic trough solar collector systems plays a vital role in efficiently utilizing the solar energy. In this paper, the least squares support vector machine (LSSVM) method is developed to model and optimize the parabolic trough solar collector system. Numerical simulations are implemented to evaluate the feasibility and efficiency of the LSSVM method, where the sample data derived from the experiment and the simulation results of two solar collector systems with 30 m2 and 600 m2 solar fields, and the complicated relationship between the solar collector efficiency and the solar flux, the flow rate and the inlet temperature of the heat transfer fluid (HTF) is extracted. Some basic rules, such as the solar collector efficiency increases with the increase of the solar flux and the flow rate of the heat transfer fluid, and decreases with the increase of the inlet temperature of the HTF, are obtained, which indicates the LSSVM method is competent to optimize the solar collector systems. As a result, the new approach will provide meaningful data for developing the parabolic trough solar thermal power plant in China.  相似文献   

20.
Concentrating solar thermal systems offer a promising method for large scale solar energy collection. Although concentrating collectors are generally thought of as large-scale stand-alone systems, there is a huge opportunity to use novel concentrating solar thermal systems for rooftop applications such as domestic hot water, industrial process heat and solar air conditioning for commercial, industrial and institutional buildings. This paper describes the thermal performance of a new low-cost solar thermal micro-concentrating collector (MCT), which uses linear Fresnel reflectors, and is designed to operate at temperatures up to 220 °C. The modules of this collector system are approximately 3 m long by 1 m wide and 0.3 m high. The objective of the study is to optimise the design to maximise the overall thermal efficiency. The absorber is contained in a sealed enclosure to minimise convective losses. The main heat losses are due to natural convection inside the enclosure and radiation heat transfer from the absorber tube. In this paper we present the results of a computational and experimental investigation of radiation and convection heat transfer in order to understand the heat loss mechanisms. A computational model for the prototype collector has been developed using ANSYS–CFX, a commercial computational fluid dynamics software package. The numerical results are compared to experimental measurements of the heat loss from the absorber, and flow visualisation within the cavity. This paper also presents new correlations for the Nusselt number as a function of Rayleigh number.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号