首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The performance of cadmium-selenide/zinc-sulfide (CdSe@ZnS) quantum dots (QDs) and the fluorescent dye Alexa 647 as reporter in an assay designed to detect apolipoprotein E (ApoE) has been compared. The assay is a sandwich immunocomplex microarray that functions via excitation by visible light. ApoE was chosen for its potential as a biomarker for Alzheimer's disease. The two versions of the microarray (QD or Alexa 647) were assessed under the same experimental conditions and then compared to a conventional enzyme-linked immunosorbent assay (ELISA) targeting ApoE. The QDs proved to be highly effective reporters in the microarrays, although their performance strongly varied in function of the excitation wavelength. At 633 nm, the QD microarray gave a limit of detection (LOD) of ~247 pg mL(-1); however, at an excitation wavelength of 532 nm, it provided a LOD of ~62 pg mL(-1), five times more sensitive than that of the Alexa microarray (~307 pg mL(-1)) and seven times more than that of the ELISA (~470 pg mL(-1)). Finally, serial dilutions from a human serum sample were assayed with high sensitivity and acceptable precision and accuracy.  相似文献   

2.
Magnetic bead based immunoassay for autonomous detection of toxins   总被引:1,自引:0,他引:1  
We are developing an automated system for the simultaneous, rapid detection of a group of select agents and toxins in the environment. To detect toxins, we modified and automated an antibody-based approach previously developed for manual medical diagnostics that uses fluorescent eTag reporter molecules and is suitable for highly multiplexed assays. Detection is based on two antibodies binding simultaneously to a single antigen, one of which is labeled with biotin while the other is conjugated to a fluorescent eTag through a cleavable linkage. Aqueous samples are incubated with the mixture of antibodies along with streptavidin-coated magnetic beads and a photoactive porphyrin complex. In the presence of antigen, a molecular complex is formed where the cleavable linkage is held in proximity to the photoactive group. Upon excitation at 680 nm, free radicals are generated, which diffuse and cleave the linkage, releasing the eTags. Released eTags are analyzed using capillary gel electrophoresis with laser-induced fluorescence detection. Limits of detection for ovalbumin and botulinum toxoid individually were 4 (or 80 pg) and 16 ng/mL (or 320 pg), respectively, using the manual assay. In addition, we demonstrated the use of pairs of antibodies from different sources in a single assay to decrease the rate of false positives. Automation of the assay was demonstrated in a flow-through format with higher LODs of 32 ng/mL (or 640 ng) each of a mixture of ovalbumin and botulinum toxoid. This versatile assay can be easily modified with the appropriate antibodies to detect a wide range of toxins and other proteins.  相似文献   

3.
xMAP technology was used for simultaneous identification of six protein toxins (staphylococcal enterotoxins A and B, cholera toxin, ricin, botulinum toxin A, and heat labile toxin of E. coli). Monoclonal antibody-conjugated xMAP microspheres and biotinilated monoclonal antibodies were used to detect the toxins in a sandwich immunoassay format. The detection limits were found to be 0.01 ng/mL for staphylococcal enterotoxin A, cholera toxin, botulinum toxin A, and ricin in model buffer (PBS-BSA) and 0.1 ng/mL for staphylococcal enterotoxin B and LT. In a complex matrix, such as cow milk, the limits of detection for staphylococcal enterotoxins A and B, cholera toxin, botulinum toxin A, and ricin increased 2- to 5-fold, while for LT the detection limit increased 30-fold in comparison with the same analysis in PBS-BSA. In the both PBS-BSA and milk samples, the xMAP test system was 3-200 times (depending on the toxin) more sensitive than ELISA systems with the same pairs of monoclonal antibodies used. The time required for a simultaneous analysis of six toxins using the xMAP system did not exceed the time required for ELISA to analyze one toxin. In the future, the assay may be used in clinical diagnostics and for food and environmental monitoring.  相似文献   

4.
An extremely sensitive bioassay has been developed for cholera toxin (CT) detection, using ganglioside-incorporated liposomes. Cholera is a diarrheal disease, often associated with water or seafood contamination. Ganglioside GM1 was used to prepare the liposomes by spontaneous insertion into the phospholipid bilayer. CT recognition and signal generation is based on the strong and specific interaction between GM1 and CT. In a sandwich immunoassay, CT was detected as a colored band on the nitrocellulose membrane strip, where CT bound to GM1-liposomes can be captured by immobilized antibodies. The intensity of the band could be visually estimated or measured by densitometry, using computer software. The limit of detection (LOD) of CT in the assay system was found to be 10 fg/mL which is equivalent to 8 zmol in the 70-microL sample. The assay was also tested with water samples spiked with CT, providing a LOD of 0.1-30 pg/mL, which is much better than previously reported limits of detection from other assays. The assay could be completed within 20 min. These results demonstrate that the bioassay developed for CT is rapid and ultrasensitive, suggesting the possibility for detecting CT, simply and reliably, in field screening.  相似文献   

5.
A direct competitive immunoassay in an antibody microarray format was developed for the sensitive detection of neuropeptide Y (NPY) and employed in the analysis of NPY in human sweat samples. This is the first demonstration that antibody microarray, as a powerful multiplex analysis tool, can be used for the sensitive determination of NPY and potentially other neuropeptides. 400 pg/mL of dibiotinylated NPY and 0.1 mg/mL spotting capture antibody were found to offer the best performance, yielding a sensitivity of 50 pg/mL and a linear dynamic range of 0.1-100 ng/mL for NPY. Evaluation of matrix effects by using artificial sweat revealed that dialysis is necessary for analyzing NPY in human sweat samples with microarray immunoassay. In a preliminary application, 50-210 pg/mL of NPY was detected in sweat samples collected with Macroduct collectors. This study indicates that antibody microarrays can be used for NPY analysis and that human sweat could be a valuable sample source for biomarker and proteomics studies, especially when noninvasive human sample collection is preferable.  相似文献   

6.
A competitive immunoassay with near-infrared (NIR) fluorescence detection to analyze microliter biological samples with an amol limit of detection (LOD) is described. An important feature about this technique is that the immunoreaction and fluorescence detection are separated into two distinct steps, allowing for independent optimization. In the immunoreaction step, NIR fluorescence-labeled antigen (Ag) competes with the unlabeled analyte (Ag) for antibodies (Ab) immobilized on the surface of paramagnetic beads. A magnet is then used to separate the bound antigen from the free in the supernatant. As the amount of Ag in the sample increases, there is less binding between Ag and immobilized Ab; therefore, the amount of Ag in the supernatant is proportionally related to the amount of Ag in the sample. In the fluorescence detection step, aliquots of the supernatant are concentrated onto a protein binding membrane by a capillary blotting technique with an optimized 33 nL/min flow rate. The fluorescence of the blotted spots is detected with a NIR sensitive photon counting system that is optimized to an instrumental LOD of 30 000 fluorophore molecules. This competitive assay demonstrates a sample LOD of 400 pg/mL of unlabeled rabbit immunoglobulin G spiked into bovine serum. This design features low sample volumes and reagent consumption.  相似文献   

7.
Over the past 5 years, the on-chip detection and manipulation of magnetic beads via magnetoelectronics has emerged as a promising new biosensor platform. Magnetic bead sensing (MBS) provides a highly sensitive and specific technique, enabling these sensors to meet the diagnostic needs that are currently not met by existing technologies. Although many studies have proven the high physical sensitivity of magnetic sensors, the establishment of dose-response curves using MBS is unexplored and their capability to sensitively detect low concentrations of target molecules for diagnostic applications has remained unproven. In this study, we have exploited an alternative MBS concept based on the repositioning of the magnetic beads toward the most sensitive location on the spin valve sensors to allow for highly sensitive immunosensing over a wide range of target concentrations. Furthermore, we present the optimization of the magnetoimmuno assay, i.e., the surface chemistry, the blocking procedure, and the type of magnetic particle, for the highly sensitive and specific detection of S100betabeta, a diagnostic marker for stroke and minor head injury. Finally, a dose-response curve was established that illustrates that our MBS platform can specifically detect S100betabeta down to 27 pg/mL, while maintaining a broad dynamic detection range of approximately 2 decades.  相似文献   

8.
The toxin ricin is a biological weapon that may be used for bioterrorist purposes. As a member of the group of ribosome-inactivating proteins (RIPs), ricin has an A-chain possessing N-glycosidase activity which irreversibly inhibits protein synthesis. In this paper, we demonstrate that provided appropriate sample preparation is used, this enzymatic activity can be exploited for functional ricin detection with sensitivity similar to the best ELISA and specificity allowing application to environmental samples. Ricin is first captured by a monoclonal antibody directed against the B chain and immobilized on magnetic beads. Detection is then realized by determination of the adenine released by the A chain from an RNA template using liquid chromatography coupled to tandem mass spectrometry. The immunoaffinity step combined with the enzymatic activity detection leads to a specific assay for the entire functional ricin with a lower limit of detection of 0.1 ng/mL (1.56 pM) after concentration of the toxin from a 500 microL sample size. The variability of the assay was 10%. Finally, the method was applied successfully to milk and tap or bottled water samples.  相似文献   

9.
CS Kim  JH Seo  HJ Cha 《Analytical chemistry》2012,84(15):6884-6890
The development of analytical tools is important for understanding the infection mechanisms of pathogenic bacteria or viruses. In the present work, a functional carbohydrate microarray combined with a fluorescence immunoassay was developed to analyze the interactions of Vibrio cholerae toxin (ctx) proteins and GM1-related carbohydrates. Ctx proteins were loaded onto the surface-immobilized GM1 pentasaccharide and six related carbohydrates, and their binding affinities were detected immunologically. The analysis of the ctx-carbohydrate interactions revealed that the intrinsic selectivity of ctx was GM1 pentasaccharide ? GM2 tetrasaccharide > asialo GM1 tetrasaccharide ≥ GM3trisaccharide, indicating that a two-finger grip formation and the terminal monosaccharides play important roles in the ctx-GM1 interaction. In addition, whole cholera toxin (ctxAB(5)) had a stricter substrate specificity and a stronger binding affinity than only the cholera toxin B subunit (ctxB). On the basis of the quantitative analysis, the carbohydrate microarray showed the sensitivity of detection of the ctxAB(5)-GM1 interaction with a limit-of-detection (LOD) of 2 ng mL(-1) (23 pM), which is comparable to other reported high sensitivity assay tools. In addition, the carbohydrate microarray successfully detected the actual toxin directly secreted from V. cholerae, without showing cross-reactivity to other bacteria. Collectively, these results demonstrate that the functional carbohydrate microarray is suitable for analyzing toxin protein-carbohydrate interactions and can be applied as a biosensor for toxin detection.  相似文献   

10.
Ahn S  Walt DR 《Analytical chemistry》2005,77(15):5041-5047
Salmonella spp. are one of the most problematic food pathogens in public health, as they are responsible for food poisoning associated with contamination of meat, poultry, and eggs. Thus, rapid and sensitive detection of Salmonella spp. is required to ensure food safety. In this study, a fiber-optic DNA microarray using microsphere-immobilized oligonucleotide probes specific for the Salmonella invA and spvB genes was developed for detection of Salmonella spp. Microarrays were prepared by randomly distributing DNA probe-functionalized microspheres (3.1-microm diameter) into microwells created by etching optical fiber bundles. Hybridization of the probe-functionalized microspheres to target DNA from Salmonella was performed and visualized using Cy3-labeled secondary probes in a sandwich-type assay format. In this study, 10(3)-10(4) cfu/mL of the target organism could be detected after 1-h hybridization without any additional amplification. The DNA microarray showed no cross-reactivity with other common food pathogens, including E. coli and Y. enterocolitica, and could even detect Salmonella spp. from cocktails of bacterial strains with only moderate loss of sensitivity due to nonspecific binding. This work suggests that fiber-optic DNA microarrays can be used for rapid and sensitive detection of Salmonella spp. Since fiber-optic microarrays can be prepared with different probes, this approach could also enable the simultaneous detection of multiple food pathogens.  相似文献   

11.
Magneto immunoassay-based strategies for the detection of Plasmodium falciparum histidine-rich protein 2 (HRP2) related to malaria are described for the first time by using magnetic micro- and nanoparticles. The covalent immobilization of a commercial monoclonal antibody toward the HRP2 protein in magnetic beads and nanoparticles was evaluated and compared. The immunological reaction for the protein HRP2 was successfully performed in a sandwich assay on magnetic micro- and nanoparticles by using a second monoclonal antibody labeled with the enzyme, horseradish peroxidase (HRP). Then, the modified magnetic particles were easily captured by a magneto sensor made of graphite-epoxy composite (m-GEC) which was also used as the transducer for the electrochemical detection. The performance of the immunoassay-based strategy with the electrochemical magneto immunosensors was successfully evaluated and compared with a novel magneto-ELISA based on optical detection using spiked serum samples. Improved sensitivity was obtained when using 300 nm magnetic nanoparticles in both cases. The electrochemical magneto immunosensor coupled with magnetic nanoparticles have shown better analytical performance in terms of limit of detection (0.36 ng mL(-1)), which is much lower than the LOD reported by other methods. Moreover, at a low level of HRP2 concentration of 31.0 ng mL(-1), a signal of 15.30 μA was reached with a cutoff value of 0.34 μA, giving a clear positive result with a non-specific adsorption ratio of 51. Due to the high sensitivity, this novel strategy offers great promise for rapid, simple, cost-effective, and on-site detection of falciparum malaria disease in patients, but also to screen out at-risk blood samples for prevention of transfusion-transmitted malaria.  相似文献   

12.
In this study, we applied the developed paired surface plasma waves biosensor (PSPWB) in a dual-channel biosensor for rapid and sensitive detection of swine-origin influenza A (H1N1) virus (S-OIV). In conjunction with the amplitude ratio of the signal and the reference channel, the stability of the PSPWB system is significantly improved experimentally. The theoretical limit of detection (LOD) of the dual-channel PSPWB for S-OIV is 30 PFU/mL (PFU, plaque-forming unit), which was calculated from the fitting curve of the surface plasmon resonance signal with a S-OIV clinical isolate concentration in phosphate-buffered saline (PBS) over a range of 18-1.8 × 10(6) PFU/mL. The LOD is 2 orders of magnitude more sensitive than the commercial rapid influenza diagnostic test at worst and an order of magnitude less sensitive than real-time quantitative polymerase chain reaction (PCR) whose LOD for S-OIV in PBS was determined to be 3.5 PFU/mL in this experiment. Furthermore, under in vivo conditions, this experiment demonstrates that the assay successfully measured S-OIV at a concentration of 1.8 × 10(2) PFU/mL in mimic solution, which contained PBS-diluted normal human nasal mucosa. Most importantly, the assay time took less than 20 min. From the results, the dual-channel PSPWB potentially offers great opportunity in developing an alternative PCR-free diagnostic method for rapid, sensitive, and accurate detection of viral pathogens with epidemiological relevance in clinical samples by using an appropriate pathogen-specific antibody.  相似文献   

13.
A novel electrochemical immunosensing strategy for the detection of atrazine based on magnetic beads is presented. Different coupling strategies for the modification of the magnetic beads with the specific anti-atrazine antibody have been developed. The immunological reaction for the detection of atrazine performed on the magnetic bead is based on a direct competitive assay using a peroxidase (HRP) tracer as the enzymatic label. After the immunochemical reactions, the modified magnetic beads can be easily captured by a magnetosensor made of graphite-epoxy composite, which is also used as the transducer for the electrochemical immunosensing. The electrochemical detection is thus achieved through a suitable substrate and mediator for the enzyme HRP. The electrochemical approach is also compared with a novel magneto-ELISA based on optical detection. The performance of the electrochemical immunosensing strategy based on magnetic beads was successfully evaluated using spiked real orange juice samples. The detection limit for atrazine using the competitive electrochemical magnetoimmunosensing strategy with anti-atrazine-specific antibody covalent coupled with tosyl-activated magnetic beads was found to be 6 x 10(-3) microg L(-1) (0.027 nmol L(-1)). This strategy offers great promise for rapid, simple, cost-effective, and on-site analysis of biological, food, and environmental samples.  相似文献   

14.
A microarray immunoassay for simultaneous detection of proteins and bacteria   总被引:11,自引:0,他引:11  
We report the development and characterization of an antibody microarray biosensor for the rapid detection of both protein and bacterial analytes under flow conditions. Using a noncontact microarray printer, biotinylated capture antibodies were immobilized at discrete locations on the surface of an avidin-coated glass microscope slide. Preservation of capture antibody function during the deposition process was accomplished with the use of a low-salt buffer containing sucrose and bovine serum albumin. The slide was fitted with a six-channel flow module that conducted analyte-containing solutions over the array of capture antibody microspots. Detection of bound analyte was subsequently achieved using fluorescent tracer antibodies. The pattern of fluorescent complexes was interrogated using a scanning confocal microscope equipped with a 635-nm laser. This microarray system was employed to detect protein and bacterial analytes both individually and in samples containing mixtures of analytes. Assays were completed in 15 min, and detection of cholera toxin, staphylococcal enterotoxin B, ricin, and Bacillus globigii was demonstrated at levels as low as 8 ng/mL, 4 ng/mL, 10 ng/mL, and 6.2 x 10(4) cfu/mL, respectively. The assays presented here are very fast, as compared to previously published methods for measuring antibody-antigen interactions using microarrays (minutes versus hours).  相似文献   

15.
Zhou Y  Zhang Y  Lau C  Lu J 《Analytical chemistry》2006,78(16):5920-5924
A novel protocol for performing a sequential dual-protein immunoassay, based on a temperature-triggered separation/mixing process and HRP-catalyzed chemiluminescence (CL) detection, is described. In contrast to current multilabel-based detection techniques, a single HRP label is employed in this proposed method. Herein we introduce poly(N-isopropylacrylamide) (PNIP) and magnetic beads as bimolecular immobilizing carriers to separate different targets by taking advantage of thermal response, as demonstrated by sequential detection of human IgG and IgA. PNIP is known to aggregate and precipitate out of water when the temperature is raised above the lower critical solution temperature (LCST) of 31 degrees C; thus, it can be separated from supernatant by centrifugation. Besides, magnetic beads can be separated from PNIP by magnetic force as the temperature is lower than LCST. A homogeneous noncompetitive ELISA was employed, formed by primary antibodies immobilized onto the surface of magnetic beads and PNIP, antigen as IgG and IgA in the sample, and HRP-labeled second antibodies. Moreover, highly sensitive CL detection of HRP was applied, and the detection limits of IgG and IgA were as low as 2.0 and 1.5 ng/mL, respectively. Within the calibrated amount, the protocol had excellent precision within 11% for each target and was comparable in performance to commercial single-analyte ELISAs. Furthermore, the proposed method has been successfully applied to the determination of dual analyte in real samples without cross-reaction, and a good correlation was achieved after comparison with the conventional assay for IgG and IgA in 40 human serum samples.  相似文献   

16.
Gangliosides, glycosphingolipids present in the membranes of neuronal and other cells, are natural receptors for a number of bacterial toxins and viruses whose sensitive detection is of interest in clinical medicine as well as in biological warfare or terrorism incidents. Liposomes containing gangliosides mimic cells that are invaded by bacterial toxins and can be used as sensitive probes for detecting these toxins. We discuss detection of three bacterial toxins-tetanus, botulinum, and cholera toxins using ganglioside-bearing liposomes. Tetanus and botulinum toxins selectively bind gangliosides of the G1b series, namely, GT1b, GD1b, and GQ1b; and cholera toxin binds GM1 very specifically. Unilamellar liposomes containing GT1b or GM1 as one of the constituent lipids were prepared by extrusion through polycarbonate membranes. To impart signal generation capability to these liposomes, fluorophore-labeled lipids were incorporated in the bilayer of liposomes. The fluorescent liposomes, containing both a marker (rhodamine) and a receptor (GT1b or GM1) in the bilayer, were used in sandwich fluoroimmunoassays for tetanus, botulinum, and cholera toxins and as low as 1 nM of each toxin could be detected. The apparent dissociation constants of liposome-toxin complexes were in 10(-8) M range, indicating strong binding. This is the first report on detection of tetanus and botulinum toxins based on specific recognition by gangliosides. The fluorescent liposomes are attractive as immunoreagents for another reason as well--they provide enormous signal amplification for each binding event as each liposome contains up to 22,000 rhodamine molecules. The present approach using receptors incorporated in bilayers of liposomes offers a unique solution to employ water-insoluble receptors, such as glycolipids and membrane proteins, for sensitive detection of toxins and other clinically important biomolecules.  相似文献   

17.
Enhanced chemiluminescence (ECL) detection can significantly enhance the sensitivity of immunoassays but often requires expensive and complex detectors. The need for these detectors limits broader use of ECL in immunoassay applications. To make ECL more practical for immunoassays, we utilize a simple cooled charge-coupled device (CCD) detector combined with carbon nanotubes (CNTs) for primary antibody immobilization to develop a simple and portable point-of-care immunosensor. This combination of ECL, CNT, and CCD detector technologies is used to improve the detection of Staphylococcal enterotoxin B (SEB) in food. Anti-SEB primary antibodies were immobilized onto the CNT surface, and the antibody-nanotube mixture was immobilized onto a polycarbonate surface. SEB was then detected by an ELISA assay on the CNT-polycarbonate surface with an ECL assay. SEB in buffer, soy milk, apple juice, and meat baby food was assayed with a LOD of 0.01 ng/mL using our CCD detector, a level similar to the detection limit obtained with a fluorometric detector when using the CNTs. This level is far more sensitive than the conventional ELISA, which has a LOD of approximately 1 ng/mL. Our simple, versatile, and inexpensive point-of-care immunosensor combined with the CNT-ECL immunoassay method described in this work can also be used to simplify and increase sensitivity for many other types of diagnostics and detection assays.  相似文献   

18.
Trichothecene mycotoxins in animal feed and human food can cause fatalities in livestock and disease in humans. In addition, these toxins are suspected chemical warfare agents. Therefore, development of a simple and sensitive method for the screening of trichothecenes is important to prevent economic loss and health hazards. A simple and inexpensive method for the detection of type-B trichothecene mycotoxins has been developed in our laboratory. By hydrolyzing the toxin under basic conditions at 80 degrees C for 1 h it is possible to detect the toxin with simple electrochemical techniques. Deoxynivalenol (DON), commonly known as vomitoxin, was used as a representative compound for type-B trichothecenes in this detection scheme. The detection limit for DON using our procedures was determined to be 9.1 microM in solution, corresponding to 0.24 ppm in a 25-g grain sample if the final extraction volume is 2.2 mL. The linear dynamic detection range was determined to be from 0.32 ppm to greater than 32 ppm. In addition to standard solutions, this method was used on rice samples spiked with DON. It was demonstrated that there is no electrochemical interference from rice extract and that 1 ppm of DON in rice samples can be quantified. This method may be ideal for toxin screening in animal feeds or in runoff from sites that produce the compounds as chemical warfare agents. Since the active moiety in DON is common to virtually all type-B trichothecenes, our approach may be ideal for type-specific screening.  相似文献   

19.
Although immunoassay-based methods are sensitive and widely used for measuring protein toxins in food matrixes, there is a need for methods that can directly confirm the molecular identity of the toxin in situations where immunoassay tests yield a positive result. A method has been developed that uses mass spectrometry to identify a protein toxin, staphylococcal enterotoxin B (SEB), in a model food matrix, apple juice. The approach employs ultrafiltration to remove low molecular weight components from the sample, after which the remaining high molecular weight fraction, containing the protein, is digested with trypsin. The tryptic fragments are separated from residual biopolymers and analyzed by liquid chromatography-electrospray mass spectrometry. The background is still sufficiently complex that tandem mass spectrometry (MS/MS) is used to confirm the identity of target peptides. Limits of detection are 80 ng of SEB for MS and 100 ng for full scan MS/MS, using a tryptic fragment as the analytical target. Lower detection limits can be obtained using selected ion monitoring and multiple reaction monitoring. The presence of SEB can be confirmed at concentrations as low as 5 parts-per-billion by increasing the size of the sample to 10 mL. The method is applicable to the detection of SEB in other water-soluble food matrixes.  相似文献   

20.
Cheng S  Shi F  Jiang X  Wang L  Chen W  Zhu C 《Analytical chemistry》2012,84(5):2129-2132
A novel detection method of small molecules, competitive immunomagnetic-proximity ligation assay (CIPLA), was developed and described in this report. Through the proximity effect caused by special proximity probes we prepared, small molecules can be detected using only one monoclonal antibody. CIPLA overcomes the obstacle that the proximity ligation assay (PLA) cannot be used in small molecular detection, as two antibodies are unable to combine to one small molecule due to its small molecular structure. Two small molecular compounds, clenbuterol (CLE) and ractopamine (RAC), were selected as targets for CIPLA. The limit of detection (LOD) reached 0.01 ng mL(-1), which was 10-50-fold lower than ELISA. With 5 orders of magnitude of the dynamic range achieved, the excellent sensitivity and broad dynamic range of CIPLA are noted. It can be applied widely in the sensitive detection of many other small molecular materials such as pesticides, additives in food, drugs, and biological samples, which have great significance in both theoretical and practical aspects.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号