首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
PurposeTo investigate effects of Rose K2 XL semi-scleral contact lenses (Menicon Co.) on visual acuity and higher-order aberrations in eyes with irregular corneas. Methods: One hundred and twelve eyes of 84 patients fitted with Rose K2 XL lenses were analysed. Participants were in 4 clinical groups: keratoconus, intra-corneal ring segments, radial keratotomy, and penetrating keratoplasty. Corrected distance visual acuity and ocular aberrations were determined before lens wear and 60 min into lens wear. The i-Trace aberrometer was used to determine aberrations at 4.5 mm pupil size.ResultsThere were 55, 22, 19 and 16 eyes in keratoconus, intra-corneal ring segments, radial keratotomy and penetrating keratoplasty groups, respectively. Before lens wear, eyes had poor corrected distance vision acuity (mean and standard deviation +0.55 ± 0.33 logMAR), high negative spherical equivalent refraction (−6.4 ± 3.7 D), high cylindrical errors (4.5 ± 2.2 D), large higher-order root-mean-squared (HO-RMS) aberration (1.5 ± 1.3 μm) and large higher-order aberration components. Cylinder was particular high for the penetrating keratoplasty group (mean 5.9 ± 2.5 D), root-mean-squared third-order coma was lowest for the radial keratotomy group (0.7 ± 1.0 μm), and fourth-order spherical aberration was highly negative for the intra-corneal ring segment group (co-efficient –0.4 ± 0.7 μm). With lens wear, the values changed considerably. Corrected distance visual acuity improved by 0.51 ± 0.31 logMAR, cylinder decreased by 3.6 ± 2.1 D, HO-RMS aberration reduced by 1.1 ± 1.2 μm, and higher-order aberration components decreased considerably. Magnitudes of group changes reflected the magnitudes before lens wear.ConclusionsRose K2 XL semi-scleral contact lenses were effective in improving vision and reducing ocular aberrations for eyes with irregular corneas.  相似文献   

2.
ObjectiveTo evaluate the efficacy of contact lenses in visual rehabilitation of a series of patients with corneal scars/opacities.MethodRetrospective review of case records of 158 patients (n = 162 eyes) with poor vision subsequent to corneal scar/opacity, who underwent contact lens fitting, was done. Primary outcome assessed was quantum of additional improvement in vision with rigid gas permeable (RGP) or soft lenses over spectacles. Success was defined as visual improvement of ≥2 lines over that of spectacles and/or improvement of vision to ≥20/60 (LogMAR 0.48).ResultsRigid gas permeable lenses were fitted in 137 eyes and soft contact lenses in 25 eyes. Lenses were successful in improving visual acuity by two or more lines over that of spectacles in 70% eyes (113 of 162 eyes), of which RGP lens accounted for 85% (96 of 113 eyes). Alternative outcome of success was defined as attainment of reasonable functional vision of >20/60 (LogMAR 0.48). This could be achieved in 65% cases (105 of 162 eyes) of which 83% (88 eyes) were with use of RGP lenses. Almost one-fourth (23.4%) patients were children less than 15 years old. Soft contact lenses were attempted in 25 instances, where RGP lens could not be fitted and were successful in 17 (68%) of these. All these 17 patients were aphakes.ConclusionsRehabilitation of corneas with visually disabling corneal opacities is possible with usage of appropriate contact lenses even in young children.  相似文献   

3.
ObjectivesTo evaluate the clinical performance and predictability using corneal topography in the fitting of a new large-diameter rigid gas permeable (RGP) contact lens design in eyes with keratoconus (KCN).MethodsThis study presents a review of eyes fitted with Alexa ES lenses for nonsurgical optimisation of visual correction. Anterior steep simulated keratometry (sim-K steep), corneal diameter (HVID), the Curvature at the apex in diopters (Cc), and distance from the corneal apex to the centre of the cornea (Lc) in millimetres derived from the Cone Location and Magnitude Index (CLMI) were recorded. Visual acuity, mean wearing time, final sagittal depth and adverse events were also recorded. Correlations between topographic indices and base curve were evaluated using the Pearson correlation coefficient.ResultsForty-six eyes from 26 patients (19 males/ 7 females) were included. Mean visual acuity improved from 0.49 ± 0.32 with glasses, to -0.02 ± 0.10 with the contact lens. The mean daily wear time was 12.19 ± 1.96 hours. No complications were detected in 95.65% of the eyes [95% CI (83.9%-99.2%)] but two episodes of non-infectious keratitis. The average sagittal depth of the lenses fitted was 0.425 ± 0.15 mm, and it was positively correlated with the Cc value (r² = 0.66, p< 0.0001, n=46) derived from the CLMI index of the pre-fitting topography.ConclusionsCorneoscleral RGP contact lenses are a safe, and effective alternative for managing KCN patients to corneal lenses. Also, clinical data derived from the corneal topography could be used to help to decide the first diagnostic lens to be assessed, easing the overall fitting process.  相似文献   

4.
ObjectivesTo evaluate the utility of the Rose K2 XL semi-scleral contact lens (Menicon Co. Ltd., Nagoya, Japan) in the management of the irregular cornea.MethodsTwenty-seven subjects (34 eyes) with irregular corneas referred for contact lens fitting were evaluated. A diagnostic trial set was used in the fitting process. Once the trial lens was considered optimal, a final lens was ordered from the manufacturer with the necessary changes in power, edge lift and diameter. We analyzed visual acuity, number of lenses ordered and patients’ ability to wear and handle lenses.ResultsTwenty-three subjects (30 eyes) were fitted with the Rose K2 XL lens. Four subjects (4 eyes) decided not to conclude the fitting process for different reasons. Average logMAR visual acuity without correction and with the lens was 0.82 and 0.09, respectively (p < 0.001). An average of 1.4 ordered lenses (range 1–3) were necessary to achieve the optimal fit. Nineteen eyes (63%) were fitted with the first lens ordered. Three subjects (13%) had problems with lens handling, and three subjects (4 eyes) abandoned the wear of the lenses after three months due to discomfort (3 eyes) and unsatisfactory visual acuity (1 eye), respectively. Follow-up ranged from 6 to 9 months.ConclusionRose K2 XL semi-scleral contact lens provides good visual acuity and comfort in patients with irregular corneas.  相似文献   

5.
Distance and near visual acuity of 13 low astigmats were determined in a double-masked experiment through thick and thin (centre thickness 0.12 mm and 0.06 mm, respectively) spherical lathe-cut soft lenses. For each lens type, distance and near LogMAR VA and over-refraction were assessed with different logMAR VA charts. For 70% of the subjects, the residual astigmatism was significantly lower than the refractive astigmatism with thicker lenses. No statistically significant differences in the distance and near logMAR VA was found between the two lens types using any of the charts used, though, in general, logMAR VA obtained through the thicker lens was better than logMAR VA through the thinner lens. The variabilities in distance and near logMAR VA between the two lens types increased with decreased contrast. The variabilities in distance logMAR VA were greater with Chinese charts than with English charts, and LogMAR VA with Chinese charts were significantly worse for both lens types. Based on the results of this study, we concluded that thicker spherical lathe-cut soft lenses provide better vision in low astigmats. The Snellen acuity test is inadequate for vision assessment of soft contact lens wearers. When a patient wearing thin soft contact lenses complains of poor vision in spite of 6/6 or 6/5 Snellen acuity, changing to thicker lenses may be considered.  相似文献   

6.
PurposeThe purpose of this study is to compare the binocular visual perception of participants wearing multifocal contact lenses and these same lens designs viewed through a temporal multiplexing visual simulator.MethodsVisual performance and perceived visual quality at various distances were obtained in 37 participants wearing soft M?CLs and through the SimVis Gekko programmed with the same lenses. In a pilot study (n = 10) visual performance was measured in terms of LogMAR visual acuity (VA) at far (4 m), intermediate (64 cm) and near (40 cm) distances and through-focus VA (TFVA) curves with the simulated M?CLs. In the follow-up study (n = 27), LogMAR VA at far, intermediate and near distances were measured both with the actual and simulated M?CLs. Perceived visual quality was measured in both studies using the Multifocal Acceptance Score (MAS-2EV), and a Participants Reported Outcomes Vision questionnaire. Differences between the metrics obtained with simulated and actual lenses were obtained.ResultsBoth actual and simulated M?CLs increased depth-of-focus by a similar amount. Mean LogMAR VA differences with actual and simulated M?CLs ranged between 4 and 6 letters (0.08 ± 0.01, 0.12 ± 0.01 and 0.10 ± 0.01, for far, intermediate and near distances, respectively). MAS-2EV average score differences with actual and simulated M?CLs ranged between ?1.00 and + 4.25. Average MAS-2EV scores were not correlated significantly with VA. However, MAS-2EV (average and individual scores) were highly correlated to visual quality questionnaire responses (p < 0.005).ConclusionsA simultaneous vision simulator accurately represented vision with M?CLs both VA at various distances and perceived visual quality, as measured in a clinical setting. The MAS-2EV metric accurately captured participant reported outcomes of standard vision questionnaires. The combination of SimVis Gekko and MAS-2EV has the potential to largely reduce chair time in M?CLs fitting.  相似文献   

7.
PurposeTo assess visual performance and patient satisfaction of multifocal contact lenses in eyes having monofocal intraocular lens (IOL) implantation.MethodsWe prospectively assessed uncorrected visual acuity at all distances (0.3, 0.4, 0.5, 0.7, 1, and 5 m), higher-order aberrations (HOAs), objective scattering index (OSI), contrast sensitivity, and patient satisfaction, before and during multifocal contact lenses wear in IOL-implanted eyes.ResultsVisual acuity at 0.3, 0.4, 0.5, 0.7, 1, and 5 m during wearing multifocal contact lenses was 0.21 ± 0.08, 0.11 ± 0.06, 0.01 ± 0.08, -0.02 ± 0.10, -0.02 ± 0.08, and -0.01 ± 0.07, respectively. We found a significant improvement at near to intermediate distances (30, 40, and 50 cm), but no significant change at intermediate to far distances (70 cm, 1 m, and 5 m). Log contrast sensitivity significantly decreased at 6 and 12 cycles/degrees, but did not significantly change at 1.5, 3, and 18 cycles/degrees. Third-order aberrations significantly increased after CL treatment, but fourth-order aberrations or total higher-order aberrations did not significantly change during CL treatment. The OSI and log(s) did not significantly change during CL treatment. The patient satisfaction score for overall vision significantly improved during CL treatment.ConclusionsMultifocal contact lenses significantly improved visual acuity at near to intermediate distances, and subsequent patient satisfaction, even though contrast sensitivity function slightly decreased, suggesting its viability of presbyopic correction in monofocal IOL-implanted eyes.  相似文献   

8.
PURPOSE: To quantify the complexity involved in fitting contact lenses on the eyes of patients with keratoconus. METHODS: The contact lens care of one randomly selected eye each of 38 keratoconus patients was retrospectively analyzed and compared to that of 38 gender and age matched controls. We evaluated the number of diagnostic contact lenses used to establish the initial contact lens order, number of ordered rigid gas permeable (RGP) contact lenses needed to complete the fit, number of office visits during the initial 4 months of care, best spectacle and RGP contact lenses corrected Log MAR visual acuities, complications encountered, and whether or not the patient was successful in contact lens wear. RESULTS: Keratoconic eyes statistically used more diagnostic lenses, more ordered lenses, and more office visits than did normal eyes. Visual acuities improved from an average of 20/40 with spectacles to an average of 20/20 by use of RGP contact lenses in keratoconic eyes. Visions were corrected to 20/20 with both spectacles and contact lenses in control eyes. Sixty nine percent (69%) of keratoconic eyes and 95% of controls were successful in contact lens wear. CONCLUSIONS: Contact lens care of keratoconic eyes is more challenging than care of normal eyes because of the need for more diagnostic and ordered contact lenses and the use of more professional time. Keratoconic eyes may suffer more complications than normals during contact lens care, but this does not affect the success rates, and such patients benefit from enhanced visual acuity with RGP contact lenses compared to that achieved with spectacles.  相似文献   

9.
The purpose of this study was to determine whether the visual acuity of keratoconic eyes was affected by alteration of back optic zone radii (BOZRs) of rigid gas permeable lenses (RGP) contact lenses. Visual acuity, spherical and sphero-cylindrical over-refraction and keratometry of the front surface of the RGP lenses of nine keratoconic eyes were measured. The BOZR of the five lenses varied from steeper to flatter than that habitually worn by the subjects. The steepest lenses produced significantly greater lens flexure and residual astigmatism (P < 0.002) and worse high and low contrast visual acuity with the spherical over-refraction (P < 0.05). There was no statistical difference in visual acuity across the range of BOZR when a sphero-cylindrical over-refraction was applied. Thus reduced visual acuity in keratoconus with steep lenses is likely due to uncorrected residual astigmatism from a combination of several possible sources.  相似文献   

10.
PurposeThis study was conducted to evaluate the effects of long-term use of rigid gas-permeable (RGP) contact lenses on corneal endothelium in keratoconus (KC) patients using non-contact specular microscopy. In addition, the correlation between wearing duration of RGP lenses (years & hours /d) and endothelial morphometric changes in KC patients was performed. This may provide more useful data for clinical application of RGP contact lens.Study designThis study was a prospective, observational, comparative, hospital based, nonrandomized, cross-sectional, and quantitative study.Subjects and methodsThe study included 40 eyes of non-wearer contact lens KC patients (group 1) and 38 KC eyes with a long history of Rose K2 RGP contact lens wearing (group 2). The corneal endothelial morphology such as endothelial cell density (ECD); coefficient of variation of cell area (CV); percentage of hexagonal cells (HEX); and central corneal thickness (CCT) were evaluated in all patients using SP3000P Specular Microscope.ResultsThe study included 40 eyes of non-wearer contact lens KC patients (20 mild KC eyes and 20 moderate KC eyes) and 38 KC eyes with a long history of RGP contact lens wearing (18 mild KC eyes and 20 moderate KC eyes). The mean duration of RGP lenses wearing was 5.67 ± 3.481 years & 12.11 ± 2.698 h/d in mild KC eyes and 7.15 ± 5.294 years &13.65 ± 2.889 h/d in moderate KC eyes. Wearing duration in hours in mild KC eyes showed a significant moderate negative correlation with ECD (r = ?0.529, p = 0.024) and a moderate positive correlation with CV (r = 0.565, p = 0.015). In addition, wearing duration in years in moderate KC eyes showed a significant moderate negative correlation with ECD (r = ?0.465, p = 0.039) and moderate positive correlation with CV (r = 0.627, p = 0.003). However, wearing duration in hours in moderate KC eyes showed a significant moderate negative correlation with HEX only (r = ?0.490, p = 0.028). This study reported significant corneal thinning in contact lens wearer KC eyes in contrast to non-wearer KC eyes.ConclusionThis study documented a significant correlation between a long-term use of Rose K2 RGP using the three-point touch and corneal endothelial morphometric changes in KC patients. In addition, the current study confirmed a significant corneal thinning in RGP contact lens wearer compared to non-contact lens wearer KC patients. Further studies are recommended to evaluate the association between different RGP lens materials with different oxygen permeability transmissibility; different lens design types; different fitting methods; the duration of contact lens wear and the endothelial morphometric changes in KC patients.  相似文献   

11.
PurposeTo evaluate the success rate of highly gas permeable scleral contact lenses (SCL) for visual rehabilitation after penetrating keratoplasty (PK), over a period of up to 9 years.MethodsA total database of 31 consecutive patient fitted with SCL between January 2004 and December 2009 was retrospectively reviewed. Demographic data, etiology prior to lens fitting, visual outcomes, follow up time and complications were analyzed.ResultsAll eyes were fitted due to inadequate spectacle-corrected vision after successful penetrating keratoplasty or failure of other contact lens modalities. Out of 31 patients fitted, 28 (33 eyes) continue to wear SCL for periods between 0.5 and 8.8 years. The mean duration of follow-up after contact lens fitting was 5.2 ± 2.2 years. The mean age of corneal graft was 17.6 ± 11.4 years (range 4.3–42), and the mean interval between PK and initial contact lens fitting was 12.2 ± 10.7 years (range 0.7–36.0). The average steepest keratometry of our cohort was 55.0 ± 7.5 diopter (D) and the refractive astigmatism was 8.0 ± 4.4 D. The mean contact lens corrected visual acuity (BCVAcl) was 0.78 ± 0.25 (range 0.3–1.2). Twenty-three (82%) patients achieved a functional vision of 0.5 or more.During the studied period, ten (30.0%) eyes presented at least one graft rejection episode and two eyes (6%) had an episode of microbial keratitis. Corneal transplants of 20 years or more show a higher rate of refits due to ectasia recurrence.ConclusionsScleral lenses should be considered as lens of choice in eyes with complex corneal geometry, as besides visual rehabilitation, their use may delay or prevent further surgical involvement.  相似文献   

12.
PurposeTo report the therapeutic effect of corneoscleral contact lenses (CLs) with a diameter of 14.0 mm on the refractory ocular surface diseases.MethodsMedical records of 13 eyes (of nine patients) attempted for fitting with corneoscleral CLs for the management of the severe refractory ocular surface diseases were retrospectively reviewed including Stevens-Johnson syndrome (SJS; eight eyes) and chronic ocular graft-versus-host disease (GVHD; five eyes). Lenses were fitted to improve refractory punctate epithelial erosions (PEE, ten eyes) and persistent epithelial defect (PED, three eyes with SJS) despite the proper medical management. Short-term (1 month) and long-term (12 months) changes in the best corrected visual acuity (BCVA), corneal fluorescein staining (CFS) score, mean wearing time, and National Eye Institute’s Visual Function Questionnaire-25 (VFQ-25) were evaluated.ResultsOf the 13 eyes, ten eyes were successfully fitted with the corneoscleral CLs. The fitting was failed in three eyes due to small palpebral fissure and shortened fornices (two eyes) and handling difficulty (one eye). At one-month follow-up after successful fitting in ten eyes, mean wearing time was 12.6 h (6.5–17, all day long) and BCVA improved from 0.56 ± 0.59 to 0.27 ± 0.46 in logMAR (P = .018). For the eight well-fitted eyes with refractory PEE, CFS score improved from 7.38±2.20 to 5.13±2.48 (P = .024). PED improved in all two eyes which were successfully fitted with corneoscleral CLs (Of the three eyes with PED, one eye failed fitting). At 12-month follow-up, mean wearing time was 11.4 h and the improved BCVA and CFS score were maintained. Furthermore, no adverse events attributable to corneoscleral CLs use occurred.ConclusionThe corneoscleral CLs with a diameter of 14.0 mm were successfully fitted in ten out of 13 eyes with severe refractory ocular surface diseases and demonstrated therapeutic benefits in the well-fitted eyes. The corneoscleral CL can be an option in the management of severe refractory ocular surface diseases.  相似文献   

13.
PurposeMultifocal soft contact lenses (MFCLs) are prescribed to inhibit myopia progression; these include aspheric and concentric designs. The effects of MFCLs on visual quality, accommodation and vergence in young-adult myopes were evaluated.MethodsParticipants were twenty-six myopes (19–25 years, spherical equivalent ?0.50 to ?5.75D), with normal binocular vision and no past myopia control. Pupil sizes were 4.4 ± 0.9 mm during distance viewing and 3.7 ± 0.8 mm at near. In random order, participants wore four MFCLs: Proclear single vision distance, MiSight concentric dual focus (+2.00D), distance center aspheric (Biofinity, +2.50D) (CooperVision lenses), and NaturalVue aspheric (Visioneering Technologies). Testing included visual acuity, contrast sensitivity (Pelli-Robson), stereoacuity, accommodation response, negative and positive relative accommodation, horizontal phorias, horizontal fusional vergence and AC/A ratio, and a visual quality questionnaire.ResultsThe four lenses differed in distance (p = 0.001) and near visual acuity (p = 0.011), and contrast sensitivity (p = 0.001). Compared with the single vision lens, the Biofinity aspheric had the greatest visual impact: 0.19 ± 0.14 logMAR distance acuity reduction, 0.22 ± 0.15 log contrast sensitivity reduction. Near acuity was affected less than distance acuity; the reduction was greatest with the NaturalVue (0.05 ± 0.07 logMAR reduction). The MFCLs altered the autorefraction measure at distance and near (p = 0.001); the accommodation response was less with aspheric lenses. Negative relative accommodation reduced with the aspheric lenses (p = 0.001): by 0.9 ± 0.5D with Biofinity and 0.5 ± 0.7D with NaturalVue. Exophoric shifts were greater with aspheric lenses (1.8 ± 2.4Δ Biofinity, 1.7 ± 1.7Δ NaturalVue) than with the concentric MiSight (0.5 ± 1.3Δ).ConclusionsMFCLs alter visual performance, refraction and vergence; two aspheric lenses had greater effect than a concentric lens.  相似文献   

14.
PURPOSE: To demonstrate the feasibility of contact lens fitting in keratoconus patients with INTACS inserts. METHODS: A chart review was conducted of all patients with bilateral keratoconus who were treated with INTACS inserts on one eye and who were subsequently referred for contact lens fitting in a university based contact lens practice between April 2000 and April 2002. The study was a retrospective, non-comparative case series. The uncorrected and best spectacle corrected visual acuity (BSCVA) after INTACS implantation surgery, postoperative best contact lens-corrected visual acuity (BCLVA), number of diagnostic contact lenses used, number of contact lenses ordered within a 4-month follow-up period, contact lens complications encountered, final base curves, final lens powers, and final wearing times were determined. RESULTS: Three keratoconic patients meeting the selection criteria were found through the chart review. Prior to surgery, all patients had uncorrected visual acuity (UCVA) of 2.0 logMAR (counting fingers). This improved to a mean of 0.81+/-0.25 logMAR (20/125-1) after surgery. Mean BSCVA also improved from 0.51+/-0.30 logMAR (20/60-2) to 0.30+/-0.16 logMAR (20/40). The mean postoperative best contact lens-corrected visual acuity was 0.02+/-0.10 logMAR (20/20-1). The number of diagnostic lenses ranged from 1 to 7. The numbers of contact lenses ordered during the 4-month follow up period ranged from 1 to 3. Two eyes were fitted with larger than usual lens designs made of rigid gas-permeable material and one eye was fitted with a toric soft lens. The final lens power ranged from +1.25 to -21.0D with a mean spherical equivalent of -7.46+/-11.89 D. Final wearing times ranged from 2.5 to 12.0h. CONCLUSION: Fitting contact lenses on keratoconus patients who have INTACS inserts is feasible and has a role in augmenting their vision.  相似文献   

15.
PurposeTo compare the clinical and topographical findings of the keratoconus patients according to the prescribed contact lens type and to investigate the effects of corneal collagen cross-linking (CXL) and cone location on lens selection.MethodsThe records of 301 eyes of 195 keratoconus patients who were prescribed contact lenses were analyzed retrospectively. The eyes were grouped according to the lens type: Soft toric contact lens (STCL), rigid gas-permeable contact lens (RGPCL), hybrid contact lens (HCL) and mini-scleral contact lens (MSCL). The history of having CXL, ophthalmological examination findings, and the topographical findings were compared between the groups. Brown-Forsythe, Chi-square, and post-hoc tests were used to compare the groups. Mann-Whitney U test was used for subgroup analysis. Comparison of the lens-corrected visual acuity (LCVA) and spectacle-corrected visual acuity (SCVA) levels was made with Wilcoxon signed-ranks test.ResultsThere was no significant difference between the groups regarding topographical cone location, CXL history, spherical refraction, and LCVA. The difference between spectacle-corrected visual acuity and LCVA was higher in RGPCL and MSCL groups than STCL group (p=0.01). Keratometry of RGPCL and MSCL groups were higher than STCL and HCL groups (p=0.01, p<0.001). In RGPCL group, eyes with central cones had a higher increase in visual acuity with contact lenses compared to eyes with paracentral cones (p=0.043). STCL and MSCL were mostly prescribed in mild and severe keratoconic eyes, respectively. In RGPCL group, the increase in visual acuity with contact lens was higher in eyes treated with CXL (p= <0.01).ConclusionsWhile STCL and HCL were mostly prescribed in mild keratoconus, RGPCL and MSCL were selected for moderate or advanced disease. If appropriately chosen, all types of contact lenses could result in a good visual acuity level. CXL history did not affect the prescribed lens type. Having central cone location and CXL history in RGPCL group improved visual acuity more efficiently.  相似文献   

16.
PurposeTo determine the efficacy of the KeraSoft® IC (KIC) (Ultravision International Limited, Bedfordshire, UK), a silicone hydrogel contact lens, for the optical management of non-surgical corneal ectasias and to compare it with the Rose-K 2 RGP contact lens.MethodsIn a retrospective study ninety-four eyes fitted with KIC (group A) were compared with seventy-seven eyes fitted with Rose-K® RGP lenses as a control group. Ocular diagnoses, corneal curvature by topography, refraction, best spectacle-corrected visual acuity (BSCVA), and age at time of fitting were noted. Outcome data included average daily wearing time, contact lens complications, visual acuity with the lens (BCLCVA), power of the lenses and length of follow-up.ResultsDifferences in either BCLCVA or wearing time could not be statistically established (p = 0.63, p = 0.15) between both groups. More biomicroscopic complications were found in the RGP group, basically corneal staining (P < 0.0001). In the KIC group, BCLCVA was statistically similar between types of ectasia (p = 0.19) as well as in mild and moderate keratoconus (p = 0.45).ConclusionsKIC is a good alternative for the optical management of irregular corneal astigmatism in non surgical corneal ectasias such as keratoconus and pellucid marginal degeneration.  相似文献   

17.
PURPOSE: To explore the success of the application of a computerised videokeratography (CVK) software system for the fitting of rigid gas permeable (RGP) contact lenses (CLs) on irregular corneal surfaces and compare it to the standard diagnostic fitting procedure. METHODS: This was a comparative prospective study, over a 1-year period (2004-2005). It included 41 RGP CL wearers (68 eyes) with irregular corneal surfaces. Of these, 51 (75%) had keratoconus, 7 (10%) corneal scarring (infectious or traumatic), 6 (6.82%) corneal transplants, 2 (2.9%) astigmatism, and 2 (2.9%) aphakia. Each eye was being re-fitted with a new RGP CL based on a topographical measurement in conjunction with a CL fitting software programme. The performance of the CLs was evaluated regarding visual outcome, fitting characteristics, and efficiency of the fitting procedure. RESULTS: Of the 68 eyes, 53 (77.94%) chose the CL fitted using the CVK software system, 9 (13.24%) chose the CL fitted using the standard procedure, and 6 (8.82%) showed no preference for either CL. There was a statistically significant improvement regarding visual outcome [contrast sensitivity at the spatial frequencies of 0.66 (p=0.029), 3.40 (p=0.008), and 17 (p=0.032), subjective vision (p=0.009)], fitting characteristics [grading scale (p=0.00), lens comfort (p=0.00) and daily wearing time (p=0.002)], and efficiency [number of trial lenses required (p=0.00)] with the CL fitted using the CVK software system. Correlating factors for the likely preference for the CL fitted using the CVK software system were subjective vision (p=0.004), lens comfort (p=0.009), and convenience of the fitting procedure (p=0.023). CONCLUSION: The application of a CVK software system for the fitting procedure of RGP CLs on irregular corneal surfaces was a safe procedure and shown to be more successful and efficient than the standard diagnostic fitting method.  相似文献   

18.

Purpose

To explore the safety profile and overall visual improvement over the course of RGP contact lens wear on children with unilateral or bilateral amblyopia resulting from myopia.

Methods

This was a retrospective analysis case series study. Clinical records of 15 patients who were fitted with RGP contact lenses at the Shanghai Eye and EENT Hospital of Fudan University between the period of January 2009 to December 2014 were reviewed. The inclusion criteria for review included patients with myopia of ?3.00DS or greater in one or both eyes and an initial best-corrected visual acuity (BCVA) of logMAR 0.4 or worse for 3 year olds, and logMAR 0.3 or worse for 4 years old and above. One or both myopic eyes were fitted with RGP lenses.

Results

15 subjects and 22 amblyopic eyes were included. The mean baseline BCVA was logMAR 0.70 ± 0.38, which improved to a VA of 0.23 ± 0.28 at the time of review (p < 0.05). Baseline myopia also increased from ?8.18 ± 2.93DS to ?11.41 ± 3.76DS (p < 0.05). The final visual acuity at the time of this review was correlated with the initial refractive error (r = ?0.695, p < 0.05) as well as the initial BCVA (r = 0.854, p < 0.05). There was also a strong correlation between initial refractive error and initial BCVA (r = 0.?801, p < 0.05)

Conclusion

RGP contact lens wear is a safe and effective refractive treatment option in young children with amblyopia due to myopia.  相似文献   

19.
PurposeMany activities of daily living rely on reading, thus is not surprising that complaints from presbyopes originate in reading difficulties rather in visual acuity. Here, the effectiveness of presbyopia correction with multifocal contact lenses (CLs) is evaluated using an eye-fixation based method of silent reading performance.ΜethodsVisual performance of thirty presbyopic volunteers (age: 50 ± 5 yrs) was assessed monocularly and binocularly following 15 days of wear of monthly disposable CLs (AIR OPTIX™ plus HydraGlyde™, Alcon Laboratories) with: (a) single vision (SV) lenses – uncorrected for near (b) aspheric multifocal (MF) CLs. LogMAR acuity was measured with ETDRS charts. Reading performance was evaluated using standard IReST paragraphs displayed on a screen (0.4 logMAR print size at 40 cm distance). Eye movements were monitored with an infrared eyetracker (Eye-Link II, SR Research Ltd). Data analysis included computation of reading speed, fixation duration, fixations per word and percentage of regressions.ResultsAverage reading speed was 250 ± 68 and 235 ± 70 wpm, binocularly and monocularly, with SV CLs, improving statistically significantly to 280 ± 67 (p = 0.002) and 260 ± 59 wpm (p = 0.01), respectively, with MF CLs. Moreover, fixation duration, fixations per word and ex-Gaussian parameter of fixation duration, μ, showed a statistically significant improvement when reading with MF CLs, with fixation duration exhibiting the stronger correlation (r = 0.79, p < 0.001) with improvement in reading speed. The correlation between improvement in VA and reading speed was moderate (r = 0.46, p = 0.016), as was the correlation between VA and any eye fixation parameter.ConclusionAverage silent reading speed in a presbyopic population was found improved with MF compared to SV CL correction and was faster with binocular compared to monocular viewing: this was mainly due to the faster average fixation duration and the lower number of fixations. Evaluating reading performance using eye fixation analysis could offer a reliable outcome of functional vision in presbyopia correction.  相似文献   

20.
ObjectivesTo assess the feasibility of fitting soft toric contact lenses (STCL) in corneal ectasias and their impact on optical quality and visual performance.MethodsA total of 22 eyes were fitted with a molded STCL: 11 eyes/9 subjects with corneal ectasia and 11 healthy eyes/11 subjects. Wavefront aberrations were analyzed using a Hartmann-Shack aberrometer. Visual performance was measured under photopic (85 cd/m 2) and mesopic (≤3 cd/m 2) conditions. High-(96 %) and low- (10 %) contrast VA (HCVA and LCVA respectively) were assessed using the ETDRS charts and contrast sensitivity (CS) using the Pelli-Robson chart.ResultsAfter STCL fitting in the ectatic corneas, oblique astigmatism increased 0.15±0.17 μm and 0.34 ± 0.36 μm for 3 mm- and mesopic pupil diameters, respectively.Mean defocus decreased 1.41 ± 0.36 μm and 2.17 ± 0.85 μm for the same pupil diameters. More positive values of vertical coma were found with a change of 0.05 ± 0.06 μm and 0.12 ± 0.10 μm for 3 mm and mesopic pupil diameters, respectively. Comparing changes between both groups, with a 3 mm pupil aperture, statistically significant differences (p < 0.05) were detected in oblique astigmatism, defocus, vertical secondary trefoil and horizontal secondary coma. In the group with corneal ectasia, photopic HCVA and LCVA improved 0.09 ± 0.11 logMAR and 0.12 ± 0.15 logMAR respectively. In mesopic conditions, HCVA, LCVA and CS improved 0.11 ± 0.12 logMAR, 0.18 ± 0.15 logMAR and 0.11 ± 0.07 log. units, respectively.ConclusionsThe analyzed molded soft toric contact lens is a feasible option for good vision in corneal ectasia with moderate irregularity and negative vertical coma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号