首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
PurposeTo evaluate comfort, visual function, and in vivo wettability after the insertion of hydrogel and silicone hydrogel contact lenses for a better understanding of how long practitioners should wait for the initial evaluation of soft contact lenses.MethodsA short-term prospective, contralateral, randomized, and participant-masked study was carried out. Twenty healthy participants (25.4 ± 2.6 years) were evaluated after the insertion of two different soft contact lenses at different times (1, 5, 10, 20, 30 min). Ocufilcon D (hydrogel) and Somofilcon A (silicone hydrogel) contact lenses were randomly assigned to both eyes of the same participant. Comfort, visual function under photopic conditions in terms of high-contrast visual acuity, low-contrast visual acuity, contrast sensitivity, and in vivo wettability were measured.ResultsThere was an increase in comfort (p < 0.001), high-contrast visual acuity (p < 0.05), and contrast sensitivity (p < 0.001, only with silicone hydrogel) directly related to time after contact lens insertion. Besides, in vivo wettability suffered a statistically significant deterioration directly related to time with both contact lenses (p < 0.05). Except for comfort and contrast sensitivity, all the parameters stabilized their values 10 min after the insertion of both soft contact lenses. Additionally, in vivo wettability and visual acuity differences were found between hydrogel and silicone hydrogel contact lenses (p < 0.05).ConclusionsIt would be possible to properly evaluate high-contrast visual acuity, low-contrast visual acuity, and in vivo wettability 10 min after the insertion of both soft contact lenses.  相似文献   

2.
PurposeTo analyse and compare the alterations in corneal endothelium morphology induced by different materials and durations of wearing soft contact lenses (CL) among young adults living in Kuala Lumpur.MethodsHealthy soft CL wearers were invited to participate in this study. Visual acuity (VA) was measured using the Snellen chart, and subjective refraction was performed using cross-cylinder technique. Standard ocular assessments were conducted using a slit lamp biomicroscope and morphology of corneal endothelial cells (endothelial cell density, ECD, coefficient variation, COV, hexagonality, HEX and central corneal thickness, CCT) were evaluated using a non-contact specular microscope. Statistical analysis was conducted using ANOVA and data from the right eye only is included.ResultsA total of 72 subjects (32 SiHy and 40 HCL wearers) and 24 non-CL wearers (control) participated in this study. The gender distribution for study subjects was 13 males and 59 females, with a mean age 22.15 ± 1.84 years old. The mean refraction was −1.86 ± 1.25DS. The duration of wearing CL ranged from 1 to 9 years. Subjects were later divided into 2 groups following duration of CL wear: Group 1 (<5 years) and Group 2 (≥5 years) for analysis purposes. Statistical analysis showed significant alterations in ECD, COV and HEX of CL wearers (p < 0.05), with more changes found in HCL and Group 2 wearers. No significant change was found in CCT.ConclusionThis study concludes that soft CL wear induced alterations in the morphology of corneal endothelial cells. Contact lens material and duration of CL wear (in years) are factors that affect the alterations. Optometrists are recommended to regularly evaluate the morphology of corneal endothelial cells in CL wearers and provide necessary intervention when required.  相似文献   

3.
PurposeTo report an unusual case with a bandage silicone hydrogel lens that was applied over cyanoacrylate glue application for corneal perforation.DesignRetrospective, interventional case report.MethodsA 67-year-old woman with a history of corneal trauma experienced spontaneous corneal perforation in her left eye. Upon arrival, her anterior chamber was flat and Seidel test was positive. After initial treatment with cyanoacrylate adhesive and a bandage silicone hydrogel contact lens, there was no leakage and the anterior chamber was formed at the follow-up period. She was started topical antibiotics.ResultsAfter 7 years, she came back with the complaint of permanent redness in her left eye with the same silicone hydrogel lens in her eye.ConclusionsCorneal healing may occur under cyanoacrylate adhesive glue with therapeutic contact lenses and with proper antibiotic application. Silicone hydrogel contact lenses exhibit good efficacy and safety when utilized as a continuous wear therapeutic lens with antibiotics.  相似文献   

4.

Purpose

To evaluate the tolerability of and subject and investigator satisfaction with delefilcon A (DAILIES TOTAL1®) daily disposable contact lenses in first-time contact lens wearers.

Methods

This European multicenter, open-label, single-arm, two-week trial enrolled first-time contact lens wearers and fitted them with delefilcon A contact lenses. Assessments were made at dispensing and at Weeks 1 and 2. Subject-reported outcomes included comfort, quality of vision, convenience, and intent to purchase, which were ranked by agreement responses. Investigator-reported outcomes included slit-lamp biomicroscopy findings and lens fit satisfaction.

Results

Ninety-two subjects were included in the per protocol dataset. Mean scores at Weeks 1 and 2 for subject-reported quality of vision and ocular comfort were significantly higher with delefilcon A contact lenses than with the subjects’ habitual spectacles during the day, at the end of the day, and overall (all p?≤?0.02). Ninety-one percent of subjects reported that their study lenses were more comfortable than expected, 98% agreed that they were convenient to use, and 92% were interested in purchasing the lenses (all p?<?0.001). Investigators reported that study lenses had an acceptable fit in at least 97% of subjects.

Conclusions

Practitioners can expect favorable outcomes when transitioning first-time contact lens wearers from spectacles to delefilcon A daily disposable contact lenses.  相似文献   

5.

Purpose

To assess corneal epithelial microstructure via confocal microscopy and determine if cellular changes are associated with lens care solutions during daily wear of silicone hydrogel contact lenses.

Methods

Corneal in vivo confocal microscopy with the Nidek ConfoScan4 was performed at baseline and after 5 months of lotrafilcon A daily contact lens wear. Enrolled participants were randomized to use either a polyhexamethylene biguanide (PHMB) preserved multipurpose care solution (MPS) or a peroxide based solution system. Lens and storage case bioburden were assessed with aerobic culture methods. Univariate and multivariable analyses were done to evaluate the association between solution use, or solution-related clinical covariates, and morphologic differences (hyper-reflectivity) in the superficial epithelial cells and epithelial basal cell density.

Results

Data on 139 participants were available for analysis of superficial epithelial cells while data on 92 participants were available for epithelial basal cell density. Five months after randomization to the solution groups, 33% of participants had visible hyper-reflective cells. More participants using MPS had ≥1 hyper-reflective cells compared to peroxide users at 5 months (44% vs. 22%; p = 0.006). Similarly at 5 months, more participants with solution-induced corneal staining (SICS) had ≥1 hyper-reflective cells compared to non-SICS participants (57% vs. 29%; p = 0.010). The adjusted odds ratios (ORs) for risk of presenting with hyper-reflective cells in MPS users or SICS participants was 2.7 (95% CI; 1.27–5.65) and 3.4 (95% CI; 1.29–8.97), respectively. Basal cell density decreased by over 350 cells/mm2 over time (about 6%) in participants who had substantial bioburden on their lenses or in their storage case.

Conclusion

The confocal microscope can detect epithelial cellular changes in vivo during contact lens wear. Hyper-reflective superficial epithelial cells are associated with a PHMB preserved solution and decreases in basal epithelial cell density may be associated with bacterial bioburden.  相似文献   

6.

Purpose

To investigate effect of topical anaesthetic (TA) during gas permeable (GP) contact lens (CL) fitting on subjective and objective measures of patient anxiety.

Methods

47 subjects (mean ± sd age = 26.9 ± 4.9 years; soft CL wearers, 18, neophytes, 29). Each subject randomly assigned to Group A or B, and attended on two occasions, one week apart. First visit: subject received bilaterally either a single drop of TA (0.5% proxymetacaine) (Group A) or placebo (0.9% saline) (Group B) prior to GP CL application. No drops were instilled at second visit. Each visit mimicked a GP CL fitting. At each visit, patient anxiety was assessed either subjectively (visual analogue scale (VAS)) or objectively (skin conductance (SC)), as well as anterior ocular health.

Results

Visit 1: GP CL trial produced small increases in hyperaemia and corneal staining, but no difference associated with TA use. Visit 2: increases in staining and hyperaemia were observed, but hyperaemic responses significantly less than at Visit 1, for both groups. Corneal staining also less, but not statistically significant. VAS scores indicated subjects who received TA during Visit 1 were significantly less anxious at Visit 2. Visit 2: comfort slightly reduced for subjects who received TA at Visit 1, and significantly increased for subjects who received placebo. Use of TA reduced anxiety during lens adaptation period compared with subjects receiving placebo.

Conclusions

TA use during GP CL fitting has potential patient benefits: improved first-time GP CL wear comfort, reduced anxiety during adaptation, reduced anxiety prior to subsequent GP CL wear.  相似文献   

7.
Purpose. To determine the extent of orthokeratology (OK) contact lens fitting worldwide and to characterize associated demographics and fitting patterns.Methods. Survey forms were sent to contact lens fitters in 45 countries between January and March every year for 14 consecutive years (2004 – 2017, inclusive). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form.Results. Data were obtained for 295,044 contact lens fits, of which 2,702 were with OK lenses and 292,342 were with other lens types (non-OK). Overall, OK lenses represented 1.2% of all contact lens fits, with significant differences between nations (p < 0.0001), ranging from no fits recorded in Brazil, Egypt, Indonesia, Iran, Lithuania, Nepal and the United Arab Emirates, to 6.0% in The Netherlands. There has been a slight overall increase in OK lens fitting over the survey period (p < 0.0001). OK lenses were fitted to younger persons (OK, 25.0 ± 12.8 years vs. non-OK, 39.8 ± 14.9 years) (p < 0.0001). A higher proportion of males (55%) were fitted with OK lenses versus non-OK lenses (30%) (p < 0.0009). There was a skewed distribution towards OK lenses being fit with higher oxygen permeable materials (p < 0.0001) and on a planned replacement basis (p < 0.0001).Conclusions. OK contact lens prescribing is a niche activity, with this lens type typically being fitted in high oxygen permeable materials on a planned replacement basis to younger males. The slightly increasing rate of OK fitting, albeit at a very low level, may be attributed to practitioner interest in the reported myopia control properties of this lens type.  相似文献   

8.
PurposeTo assess the influence of contemporary contact lens (CL) materials on human coronavirus attachment and the influence of a rub and rinse step to remove these viruses.MethodsThe binding rates of HCoV-229E and HCoV-OC43 to eight soft CL materials and four rigid gas permeable materials were analyzed. The impact of a rub and rinse step to remove these viruses from all materials was examined. The efficacy of Biotrue (Bausch & Lomb), OPTI-FREE Puremoist (Alcon), Clear Care (Alcon) and cleadew (Ophtecs) to remove virus contamination from two representative soft lens materials (etafilcon A and lotrafilcon B) was also determined.ResultsApproximately 102 to 103 infectious viral particles were recovered from each CL material. Although some materials were more prone to coronavirus adhesion, contamination of both viral types was reduced to below the limit of quantification (LQ) from all materials using a simple saline rinse step. Exposure to Clear Care and cleadew reduced the number of infectious viral particles from both etafilcon A and lotrafilcon B to below the LQ, while for Biotrue and OPTI-FREE Puremoist, infectious viral particles were reduced to below the LQ only when additional rub and rinse steps were included.ConclusionHuman coronavirus contamination can be easily removed from CL surfaces. Although CL care products containing hydrogen peroxide and povidone-iodine efficiently removed virus contamination from CL surfaces without the need for a rub and rinse step, a full regimen including rub and rinse steps is crucial when using CL care products based on non-oxidative systems.  相似文献   

9.

Purpose

To compare the effects of a hydrogen peroxide (H2O2)-based lens care solution and a polyhexamethylene biguanide (PHMB) multi-purpose solution on the eyelids when used with silicone hydrogel (SiHy) contact lenses.

Methods

A total of 74 symptomatic wearers of ACUVUE® OASYS® (senofilcon A; n?=?39) or PureVision® (balafilcon A; n?=?35) contact lenses were randomised 1:1 to either CLEAR CARE® Cleaning & Disinfecting Solution or renu® fresh? multi-purpose solution (n?=?37 each). Assessments of hyperaemia, papillae and lid margin staining of eyelid tissue were evaluated subjectively by a masked investigator at enrolment (with the subjects’ habitual SiHy contact lenses and PHMB-preserved care systems), at dispensing visit (when no lenses were worn) and at 3-months’ follow-up.

Results

There were no differences in eyelid assessments between the two lens care groups at dispensing visit (p?=?0.086 to 0.947). After 3 months, the papillae response was significantly less marked with H2O2-based solution than with PHMB-based solution (p?=?0.017). Lid hyperaemia (p?<?0.001) and papillae (p?=?0.002) were also significantly reduced. Although lid hyperaemia was also reduced with PHMB-based solution (p?<?0.001), there was no concurrent decrease in papillae response (p?=?0.051). No improvements were found in eyelid margin staining either over time or between the two lens care groups.

Conclusion

In symptomatic contact lens wearers, a H2O2-based lens care solution used with senofilcon A and balafilcon A lenses was better tolerated by eyelid tissues than was a PHMB-based solution and led to a decrease in clinical markers of eyelid inflammation.  相似文献   

10.
PurposeTo compare the efficiency and safety of two bandage contact lenses after photorefractive keratectomy (PRK).MethodsIn this double-blind study, 45 patients (90 eyes) received PRK in both eyes and wore bandage contact lenses (BCLs), PureVision (Bausch & Lomb, Rochester, NY, USA) in one eye and PureVision2 (Bausch & Lomb, Rochester, NY, USA) in the other eye, randomly assigned. The medication regimen after surgery was the same for both eyes. The epithelial defect's size, conjunctival hyperemia and lens centration were graded objectively using slit-lamp biomicroscopy on days 1, 3 and 5 after surgery. Also ocular symptoms of discomfort including tearing, photophobia, foreign body sensation and visual fluctuations were assessed subjectively at each visit.ResultsThe mean epithelial defect size on the first day after operation was similar in eyes fitted with PureVision (30.08 ± 5.30 mm²) and PureVision2 (30.25 ± 5.72 mm2) lenses. (p = 0.79) Contact lens deposits and bulbar hyperaemia on days 1 and 3 after PRK were similar between the two eyes, but were significantly greater on day 5 for PureVision2 lenses. (p = 0.02; p = 0.04 respectively) There was no difference in contact lens decentration, and discomfort symptoms including pain, tearing, foreign body sensation, photophobia and visual fluctuations between the eyes fitted with PureVision and PureVision2. (p > 0.05)ConclusionsPureVision and PureVision2 contact lenses are equivalent as bandage lenses in important aspects such as corneal re-epithelialization and subjective comfort., although PureVision2 led to a higher incidence of contact lens deposits and conjunctival hyperemia early post-PRK.  相似文献   

11.
12.
PurposeTo report the use of corneoscleral lenses (CSL) in keratoconus patients who were unsatisfied with their visual outcomes after keratoplasty surgery.MethodsEleven consecutive cases with unsatisfactory vision with spectacles, due to irregular astigmatism, preferred to try CSL before SL due to handling or economic issues. An eye examination included refraction and visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelial-cell count (ECC) and evaluation of corneal biomechanical parameters (corneal resistance factor, CRF; corneal hysteresis, CH; corneal-compensated intraocular pressure, IOPcc). The fitting process was performed using a diagnostic fitting set. Subjective visual quality and comfort, and CSL usage time were also recorded. Patients were monitored for 1 year.ResultsTwo patients presented intolerance to CSL. Therefore, nine patients (6 males and 3 females; the mean±SD age, 44.56 ± 17.33 years, range 27–82) were fitted with CSL. The log MAR visual acuity of these eyes improved significantly with CSL in relation to the best spectacle-corrected vision (0.02 ± 0.06 vs 0.22 ± 0.15, respectively; p = 0.007). Patients reported prolonged usage times (an average of 9.78 ± 1.99 h; range, 8–14). No significant adverse ocular effects or clinically relevant changes in ocular parameters (ECC, CH, IOPcc, central corneal thickness and keratometry; all p > 0.05), visual quality, comfort rating or usage time were found during the 1-year follow-up.ConclusionCorneoscleral lenses could be fitted in non-severe cases after keratoplasty surgery with optimal visual results as they can be a safe and healthy alternative option.  相似文献   

13.
PurposeReplacing soft contact lenses (CLs) on a daily basis brings a number of advantages, most notably, reduced exposure to deposits, disinfectants, allergens, and other contaminants. This retrospective study estimated the prevalence of problems in current wearers of reusable soft CLs and tested the effect of refitting “problem” patients with daily disposable (DD) hydrogel lenses.MethodsPrevalence was estimated from 398 current reusable CL wearers for: frequent/constant discomfort or dryness, ≥2 h of uncomfortable wear, ≥grade 2 conjunctival hyperaemia (0–4), or ≥grade 3 corneal staining (0–15). In the second part of the study, 217 reusable CL wearers classified as problem patients were randomly refitted with DD lenses manufactured from one of two materials: etafilcon A (n = 96) or nelfilcon A (n = 121) and reassessed 1 week later.ResultsThirty-nine percent (154/398) had some qualifying criterion: reduced comfortable wearing time (CWT), 20%; dryness, 20%; irritation, 5%; corneal staining, 8%; and hyperaemia, 7%. After refitting with DDs, the prevalence of reduced CWT was decreased from 65% to 51% (P = 0.0039), dryness from 60% to 41% (P < 0.0001) and corneal staining from 28% to 21% (P = 0.04). There was no significant change in the prevalence of irritation, or hyperaemia. Some differences were noted between the two lens materials.ConclusionsA high proportion of reusable soft lens wearers encounter clinically relevant signs or symptoms with their current CLs. This study provides evidence that refitting with DD lenses is a useful strategy for alleviating some of the common problems of CL wear.  相似文献   

14.

Purpose

To compare the corneal topographical changes induced by two first and second generation silicone-hydrogel (SiH) contact lenses after 3 months of daily wear (DW).

Methods

Prospective, consecutive case-series in which patients wore one of 3 different contact lenses (either the first generation SiH Focus Night & Day, the second generation SiH Acuvue Oasys or the monthly disposable Soflens 38 hydrogel lens as control group) on a DW basis for 3 months. Over-refraction, visual acuity, mean keratometry, corneal astigmatism, corneal eccentricity, superficial regularity and superficial asymmetry indices were monitored over the 3-month period.

Results

Nineteen eyes of 10 patients completed the study. Seven Focus Night & Day, 7 Acuvue Oasys and 5 Soflens 38 contact lenses were fitted. There were no significant changes between any of the parameters measured at the 3-month visit in any of the SiH groups (non-parametric Wilcoxon test, p > 0.05). However, the control group (Soflens 38) showed statistically significant changes regarding mean keratometry, corneal astigmatism and corneal eccentricity (p < 0.05). Three patients wearing the first generation SiH showed adverse events of different degree related to their high modulus of elasticity.

Conclusions

After 3 months of DW, wearers of first and second generation SiH lenses showed greater corneal stability than hydrogel monthly disposable contact lenses users regarding commonly used topographic corneal shape indices. However, complications related to the mechanical properties of first generation SiH were seen in three patients in the follow-up time.  相似文献   

15.

Objective

To study the influence of soft contact lens (SCL) central thickness and material in keratoconus on visual function after intracorneal ring segment (ICRS) surgery.

Methods

A pilot, experimental, prospective, cross-sectional and double-blind study was performed. Fourteen keratoconus patients with age range of 34.75 ± 9.22 years (7 males and 7 females) with ICRS implanted were involved in the study. Two different SCL materials [Hioxifilcon A (G-5X/p-GMA/HEMA) and Lucifilcon A (silicone-hydrogel)] with four different central thicknesses (0.1, 0.2, 0.3 and 0.4 mm) were fitted in one eye per patient, selected randomly. High and low corrected distance visual acuity (CDVA) and contrast sensitivity (CS), corneal topography and corneal and total aberrometry were measured.

Results

Corneal spherical like, coma like and root mean square (RMS) decreased significantly for 0.3 and 0.4 mm in both SCL materials (p < 0.05). Total RMS decreased significantly for 0.4 mm with both SCL materials (p < 0.05). High and low CDVA improved for 0.4 mm of thickness for both materials (p < 0.05). Statistically increasing were found in all thicknesses studied for CS in both materials (p < 0.05).

Conclusion

A central thickness of the SCL equal or superior to 0.4 mm seems to decrease the ocular high order aberration (HOA) and to improve the visual function in keratoconus patients implanted with ICRS. However, the modulus of rigidity of the SCL would not influence the HOA correction.  相似文献   

16.
In order to establish the relevance of oxygen to contemporary contact lens practice, a review of the literature was conducted. The results indicate that there are a number of processes occurring in the normal healthy eye where oxygen is required and which are potentially affected by the presence of a contact lens. These activities appear to take place at all corneal levels, as well as at the limbus. Evidence from laboratory, clinical and modelling studies indicates that what constitutes normal oxygenation (normoxia) depends on, among other things, the physiological system under consideration, corneal location and the state of eye closure. This diversity is reflected in the wide range of minimum lens oxygen transmissibility (Dk/t) requirements that are present in a literature.  相似文献   

17.
ObjectivesTo evaluate the clinical performance and predictability using corneal topography in the fitting of a new large-diameter rigid gas permeable (RGP) contact lens design in eyes with keratoconus (KCN).MethodsThis study presents a review of eyes fitted with Alexa ES lenses for nonsurgical optimisation of visual correction. Anterior steep simulated keratometry (sim-K steep), corneal diameter (HVID), the Curvature at the apex in diopters (Cc), and distance from the corneal apex to the centre of the cornea (Lc) in millimetres derived from the Cone Location and Magnitude Index (CLMI) were recorded. Visual acuity, mean wearing time, final sagittal depth and adverse events were also recorded. Correlations between topographic indices and base curve were evaluated using the Pearson correlation coefficient.ResultsForty-six eyes from 26 patients (19 males/ 7 females) were included. Mean visual acuity improved from 0.49 ± 0.32 with glasses, to -0.02 ± 0.10 with the contact lens. The mean daily wear time was 12.19 ± 1.96 hours. No complications were detected in 95.65% of the eyes [95% CI (83.9%-99.2%)] but two episodes of non-infectious keratitis. The average sagittal depth of the lenses fitted was 0.425 ± 0.15 mm, and it was positively correlated with the Cc value (r² = 0.66, p< 0.0001, n=46) derived from the CLMI index of the pre-fitting topography.ConclusionsCorneoscleral RGP contact lenses are a safe, and effective alternative for managing KCN patients to corneal lenses. Also, clinical data derived from the corneal topography could be used to help to decide the first diagnostic lens to be assessed, easing the overall fitting process.  相似文献   

18.
Refracting telescopes are afocal compound optical systems consisting of two lenses that produce an apparent magnification of the retinal image. They are routinely used in visual rehabilitation in the form of monocular or binocular hand held low vision aids, and head or spectacle-mounted devices to improve distance visual acuity, and with slight modifications, to enhance acuity for near and intermediate tasks. Since the advent of ground glass haptic lenses in the 1930’s, contact lenses have been employed as a useful refracting element of telescopic systems; primarily as a mobile ocular lens (the eyepiece), that moves with the eye. Telescopes which incorporate a contact lens eyepiece significantly improve the weight, comesis, and field of view compared to traditional spectacle-mounted telescopes, in addition to potential related psycho-social benefits. This review summarises the underlying optics and use of contact lenses to provide telescopic magnification from the era of Descartes, to Dallos, and the present day. The limitations and clinical challenges associated with such devices are discussed, along with the potential future use of reflecting telescopes incorporated within scleral lenses and tactile contact lens systems in low vision rehabilitation.  相似文献   

19.
PurposeContact lenses offer a good option for patients with presbyopia, especially with improved optical designs available in modern multifocal contact lenses. Due to the ageing population there is good opportunity to increase contact lens penetration by managing these patients better. However, multifocal contact lenses achieve low penetration in the market.MethodsA questionnaire was administered to people aged above 40 years, to investigate their perceptions of contact lenses for presbyopia. Only people, with presbyopia, who were existing contact lens wearers or willing to try contact lenses were included. Participants were recruited from United Kingdom (UK), United States of America (USA), Netherlands, Germany, France, Spain and Italy.ResultsData from 1540 participants above the age of 40 years was collected, 57.9% were females and 42.1% males. Overall, 50.8% of the participants wore contact lenses, but contact lens wear was less common amongst older participants. Some data supported earlier studies, such as 6.1% wore gas permeable lenses. However, only 25% of the contact lens wearers used multifocal contact lenses. The reasons the participants wanted to wear contact lenses were similar to younger patient such as sports or cosmesis reasons. Reasons why participants had dropped out of contact lenses included discomfort and dry eye related issues. Poor visual performance with contact lenses was a reason to dropout of contact lenses for the older participants.ConclusionsThe study highlights some failings by eye care practitioners in the management of patients with presbyopia. It seems that patients of this age group are seeking suggestions and recommendations from their eye care practitioner including upgrading contact lenses and dual wear options. The day-to-day problems encountered by the contact lens wearers in this study seem to be, in the main, things that could be easily tackled by additional counselling and instruction from the eye care practitioners.  相似文献   

20.
PURPOSE: The purpose of this work was to evaluate the ability of four silicone-hydrogel contact lenses (galyfilcon A, balafilcon A, lotrafilcon A and lotrafilcon B) to retain their equilibrium water content before and after wear, through measurements of refractive index and compare with that of a conventional disposable hydrogel contact lens (etafilcon A). METHODS: The refractive indices of 115 contact lenses were measured using an automated refractometer (CLR 12-70, Index Instruments, Cambridge, U.K.) before and after a schedule of daily wear by 58 patients for 30 days in the case of silicone-hydrogel lenses and 15 days for the conventional contact lenses. RESULTS: In the silicone-hydrogel contact lenses the changes on the refractive indices were not statistically significant, however after being worn the refractive index of the conventional etalfilcon A hydrogel contact lens increased significantly (p<0.001). CONCLUSION: The results presented here show that after being worn the silicone-hydrogel contact lens, show more capacity to retain or to reach their initial equilibrium water content than conventional hydrogel contact lenses. This suggests that the silicone-hydrogel contact lenses are less susceptible to spoilation over time maintaining its biocompatibility and contributing to the clinical success of lens performance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号