首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Jianhua Fan  Simon Furbo 《Solar Energy》2012,86(11):3460-3469
This paper presents numerical investigations of thermal stratification in a vertical cylindrical hot water tank established by standby heat loss from the tank. The transient fluid flow and heat transfer in the tank during cooling caused by standby heat loss are calculated by means of validated computational fluid dynamics (CFD) models. The measured heat loss coefficient for the different parts of the tank is used as input to the CFD model. Parametric studies are carried out using the validated models to investigate the influence on thermal stratification of the tank by the downward flow and the corresponding upward flow in the central parts of the tank. Tank design parameters such as tank volume, height to diameter ratio and insulation and different initial conditions of the tank are investigated.It is elucidated how thermal stratification in the tank is influenced by the natural convection and how the heat loss from the tank sides will be distributed at different levels of the tank at different thermal conditions. The results show that 20–55% of the side heat loss drops to layers below in the part of the tank without the presence of thermal stratification. A heat loss removal factor is introduced to characterize the effect of the buoyancy driven flow on exchange of heat loss between tank layers by natural convection. Based on results of the parametric studies, a generalized equation for the heat loss removal factor is obtained by regression which takes into account the influences of tank volume, height to diameter ratio, tank insulation and initial conditions of the tank. The equation is validated for a 150–500 l tank insulated with 0–7 cm mineral wool and a tank height to diameter ratio of 1–5. The equation will be implemented in an existing tank optimization and design program for calculation of thermal performance of a hot water tank.  相似文献   

2.
To sufficiently store and use high-quality heat energy, thermal stratification is gradually applied in many kinds of energy storage fields such as solar thermal utilization system. Because of the unsteady characteristics of solar radiation, thermal storage becomes very essential in long-term operation of heating load. The wide application of thermal stratification lies in the minimization of the mixing effect by use of the thermal stratification, which is caused by the thermal buoyancy because of the difference of temperature between cold and hot water. According to the review, the conception of thermal stratification allows a wide variety of different design embodiments, which essentially extends the fields of practical application of these devices. In this paper a survey of the various types of thermal stratification tanks and research methods is presented, and reasons of energy storage with efficiency problems related to the applications are introduced and benefits offered by thermal stratification are outlined. The structure designs based on theoretical prediction of thermal-stratified water tank performed at many organizations are introduced and are compared with their experimental results. Finally, the development of the tank with thermal stratification in the future application is predicted.  相似文献   

3.
A significant decrease in the degree of thermal stratification is demonstrated by improvising transverse wall ribs on the inner cylindrical surfaces of large liquid hydrogen storage tanks. The ribbed surfaces are modeled as fins and a conjugate transient heat transfer problem is formulated for predicting flow currents and heat transfer. Turbulent Rayleigh numbers between 1.2×10121.2×1012 and 6×10166×1016 are considered. A stratification parameter based on the moment of energy is defined to quantify the degree of stratification and this parameter is seen to be about 30% lower for the ribbed tanks. The degree of stratification is not sensitive to changes in the ratio of the rib height to the spacing between the ribs. The transient free convection is shown to be characterized by the parameter Fo×Ra0.15Fo×Ra0.15. The process of stratification takes place more slowly in the ribbed tanks than in smooth-walled tanks. The free convective heat transfer coefficient for tanks having ribbed surface is also seen to be significantly lower. Incorporation of ribs over the inner surface of the insulated tanks is demonstrated to offer a simple means of reducing the stratification and boil-off losses.  相似文献   

4.
PCM-module to improve hot water heat stores with stratification   总被引:1,自引:0,他引:1  
Hot water heat stores with stratification are a common technology used in solar energy systems and reuse of waste heat. Adding a PCM module at the top of the water tank would give the system higher storage density, and compensate heat loss in the top layer. The work presented here includes experimental results and numerical simulation of the system using an explicit finite-difference method. Experiments and simulations were carried out using different cylindrical PCM modules. With only 1/16 of the volume of the store being PCM, 3/16 of water at the top of the store was held warm for 50% to 200% longer and the average energy density was increased by 20% to 45%. Furthermore, these 3/16 of water were reheated by the heat from the module after being cooled down in only 20 min.  相似文献   

5.
罗艳  汤金华 《节能》2008,27(12)
利用多节点模型描述蓄热水箱温度分层,将这种模型应用到太阳能生活供热系统中,研究温度分层对太阳能供热系统性能的影响。研究表明:水箱温度分层显著提高集热器效率,对平板集热器的影响大于真空管集热器。用水模式、供水温度、供回水温差,对水箱温度分层都有影响。  相似文献   

6.
In this brief note, we have experimentally measured the temperature stratification in a solar hot water storage tank resulting from a simulated solar heating load. Various modifications using a double chimney device that acts as a thermal diode were examined with the intent of maximizing temperature stratification. The greatest stratification was seen with a unique thermal diode arrangement named the express-elevator design, so-called for the direct hot water path from the bottom third of the tank to the top third.  相似文献   

7.
The onset of convection in a horizontal stratified porous layer heated from below is studied theoretically. The stratification is continuous and periodic, with N/2 periods within the layer. For large numbers of N the critical Rayleigh number converges towards the limit of homogeneous anisotropy with a deviation proportional to N−2.  相似文献   

8.
Ulrike Jordan  Simon Furbo   《Solar Energy》2005,78(2):291-300
Storage tanks with different cold water inlet devices for small Solar Domestic Hot Water (SDHW) systems are compared. The objective of the investigation is to reveal the impact of the cold water inlet device on the thermal stratification in two marketed tanks and to evaluate the possible enhancement in the annual system performance of small solar heating systems. Two different marketed inlet designs are compared, one connected to a small curved plate placed above the inlet tube, the other one connected to a much larger flat plate. The cold domestic water enters the stores in vertical direction from the bottom of the tanks. Temperature measurements were carried out for different operating conditions. It was shown that the thermal stratification inside the two tanks depends differently on the flow rate, the draw-off volume, as well as the initial temperature in the storage tank. To carry out system simulations, a multi-node storage model was used and expanded by an additional input variable to model the mixing behaviour depending on the operating conditions. The inlet device with a comparatively large plate compared to the less favourable design results in an increase of the solar fraction of about 1–3%-points in annual system simulations with a solar fraction of about 60% and fairly large domestic hot water flow rates. This corresponds to a reduction of the auxiliary energy supply of the solar heating system of about 3–7% (58–155 MJ/year) for the investigated solar domestic hot water system.  相似文献   

9.
An analysis of transient, two dimensional, mixed convection and thermal stratification in cylindrical hot water storage tanks is presented. The governing equations together with inflow and outflow boundary conditions are written for laminar mixed convection flow using a finite volume based computational code in the dynamic discharging mode based on Boussinesq approximations and conjugate heat transfer. The equations are solved numerically and the results are obtained for aspect ratios of the tanks ranging from 1 to 4 in the Richardson number range of 105 to 108 using a finite volume based computational code. The dynamic discharging mode is considered using a conjugate heat transfer model. The transient temperature profiles in the bulk fluid reveal reduced mixing at higher Richardson numbers during discharging process. The system performance in the dynamic mode of operation is defined by a Mix Number and discharging efficiency parameter. Mixing at the bottom of the tank due to inflow of low temperature water from the load is found to have significant influence on the storage efficiency. The discharging efficiency decreases with Fourier number due to increased thermal degradation with time.  相似文献   

10.
Thermal stratification in a mantled hot water storage tank is analysed numerically for different water inlet velocities. The aim is to obtain higher thermal stratification and supply hot water for usage as long as possible. Twelve different water inlet velocities to the hot water storage tank are considered. The numerical method is validated by comparing its results against experimental and numerical results from the literature. It turned out that the results obtained from the numerical analysis have shown very good agreements with the results from previous works. As a result, the water temperature in the tank increases with the increase of the water inlet velocities to the mantle but this increment is not proportional. After a period of operation of 7.2 h, which corresponds to the average sunshine duration in Turkey, temperature increments of 6.5 and 35 K have been estimated for the hot water inlet velocities of 0.01 and 0.3 m s?1, respectively, at a radial distance of 0.1 m and a height of 1 m inside the storage tank. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

11.
为研究具有内置隔板的太阳能蓄热水箱隔板开孔尺寸及位置对其内部热分层效果的影响,对9种隔板开孔位置的太阳能蓄热水箱内温度场进行了数值分析,结果显示:在相同的流动参数及开孔面积条件下,隔板中心开1个圆孔的水箱热分层效果最好。对于多开孔的水箱,开孔位置对水箱内热分层影响不大,但对蓄热量影响显著。对于隔板中心开1个圆孔的水箱,在不同流动参数条件下,冷、热水出口温差随着冷水入口流速的增大呈先增后减的趋势,当冷水入口流速大于0.9 m/s时,减弱了热分层的稳定性。  相似文献   

12.
Thermal stratification of cryogenic propellants under the condition of external heat leakage is a dominating factor pressurizing the storage tank, which hinders long-term on-orbit storage missions for future explorations. Whether a thermodynamic venting system or cryocooler is introduced to reduce the boil-off losses or even realize zero boil-off of the cryogens, an efficient mixing and heat-exchanging device is a prerequisite for eliminating thermal stratification. Usually, a subcooled stream is introduced, which is injected into the tank through the nozzles on a spray bar. Early research provided evidence that the cooling effect is related to the arrangement of the nozzles. In contrast to adopting a heavy plate spray bar to realize the temperature profile symmetry along the tank axis, this study proposes an assembly with a rotatable nozzle head to diminish the temperature non-uniformity in the tank. In this manner, over 70% of the spray bar payload can be saved compared to the plate configuration. A three-dimensional model was established to investigate the temperature distribution of liquid hydrogen at zero gravity in a tank containing such a rotatable sprayer, which was passively driven by the counterforce of the injection flow, and therefore excluded an extra power drive demand. The injection inlet velocity, as well as the length and quantity of the nozzle arms, were analyzed parametrically to optimize the destratification performance. By employing the self-spinning sprayer, the standard deviation of the temperature in the tank could be lowered, along with the benefits of a significant payload reduction and elimination of direct power input.  相似文献   

13.
低温热水墙体辐射供暖技术因其节能、舒适及对供暖温度(热源品位)要求低等优势而越来越得到广泛应用。在研究相变墙体辐射供暖系统的基础上,针对相变墙体层蓄热效率低的问题,提出采用一种新的复合相变墙体板。并建立相应复合相变墙体的传热模型,利用数值模拟软件对复合相变墙体的蓄放热过程进行分析,对比分析了有复合相变层和没有相变层时室内供暖系统的区别,同时研究了相变温度、相变层厚度等参数对复合相变墙体表面平均温度、表面热流密度的影响,得到了它们对复合相变墙体的传热过程的影响规律。研究结果可为提高供暖系统的舒适度提供理论依据,并为发展低品位能源利用提供技术支持。  相似文献   

14.
《Applied Thermal Engineering》2007,27(11-12):1986-1995
The simulation and the optimisation of the mantle tank of solar domestic hot water systems needs dynamic simulation over long periods of time (e.g. 1 year). A model for such a mantle tank was developed by using the zonal approach. The dimensions of the zones are determined based on physical considerations. A mixing coefficient is identified to model the water flow in the mantle heat exchanger. Comparisons of the results of temperatures distribution of the model and of experiments show a difference <7% for three positions of the inlet water flow in the mantle heat exchanger.  相似文献   

15.
按照热力学原理、根据国家标准对已竣工的江苏五台山体育中心游泳馆太阳热水系统工程,提出了运行状态下的系统热性能验收测试方案,进行了测试工作,并取得测试结果.所提出的运行状态下的系统热性能验收测试方案,解决了工程热性能验收问题,具有实用价值.  相似文献   

16.
The main objective of this study is to optimize the long-term performance of an existing active-indirect solar hot water plant (SHWP), which supplies hot water at 65 °C for use in a flight kitchen, using a micro genetic algorithm in conjunction with a relatively detailed model of each component in the plant and solar radiation model based on the measured data. The performance of SHWP at Changi International Airport Services (CIASs), Singapore, is studied for better payback period using the monthly average hourly diffuse and beam radiations and ambient temperature data. The data input for solar radiation model is obtained from the Singapore Meteorological Service (SMS), and these data have been compared with long-term average data of NASA (surface meteorology and solar energy or SSE). The comparison shows a good agreement between the predicted and measured hourly-averaged, horizontal global radiation.The SHWP at CIAS, which comprises 1200 m2 of evacuated-tube collectors, 50 m3 water storage tanks and a gas-fired auxiliary boiler, is first analyzed using a baseline configuration, i.e., (i) the local solar insolation input, (ii) a coolant flow rate through the headers of collector based on ASHRAE standards, (iii) a thermal load demand pattern amounting to 100 m3/day, and (iv) the augmentation of water temperature by auxiliary when the supply temperature from solar tank drops below the set point. A comparison between the baseline configuration and the measured performance of CIAS plant gives reasonably good validation of the simulation code. Optimization is further carried out for the following parameters, namely; (i) total collector area of the plant, (ii) storage volume, and (iii) three daily thermal demands. These studies are performed for both the CIAS plant and a slightly modified plant where the hot water supply to the load is adjusted constant at times when the water temperature from tank may exceed the set temperature. It is found that the latter configuration has better thermal and economic performances over the conventional design.  相似文献   

17.
18.
The thermal decay of an initially hot isothermal water body contained in a tank was studied. Analytical solutions (including a group-theoretic solution) were obtained for the one-dimensional heat conduction equation with heat loss from the sides of the tank. The convective heat transfer coefficient was assumed not to be constant over the surface of the tank but to vary with space and time. A very good agreement was obtained between the group-theoretic solution and a numerical solution using the Crank-Nicholson finite difference scheme. The analytical results are discussed in terms of the underlying physical mechanisms.  相似文献   

19.
Experimental results on the thermal characteristics of air-water spray impingement cooling of hot metallic surface are presented and discussed in this paper.The controlling input parameters investigated were the combined air and water pressures,plate thickness,water flow rate,nozzle height from the target surface and initial temperature of the hot surface.The effects of these input parameters on the important thermal characteristics such as heat transfer rate,heat transfer coefficient and wetting front movement were measured and examined.Hot flat plate samples of mild steel with dimension 120 mm in length,120 mm breadth and thickness of 4 mm,6 mm,and 8mm respectively were tested.The air assisted water spray was found to be an effective cooling media and method to achieve very high heat transfer rate from the surface.Higher heat transfer rate and heat transfer coefficients were obtained for the lesser i.e,4 mm thick plates.Increase in the nozzle height reduced the heat transfer efficiency of spray cooling.At an inlet water pressure of 4 bar and air pressure of 3 bar,maximum cooling rates670℃/s and average cooling rate of 305.23℃/s were achieved for a temperature of 850℃ of the steel plate.  相似文献   

20.
This paper describes temperature measurements and flow visualization in a piston-cylinder enclosure where a temperature difference is suddenly established between the enclosure and the gas contained in it. The data provides experimental support for the existence of internal waves and reveals several time constants that characterize the process.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏