首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到15条相似文献,搜索用时 15 毫秒
1.
This paper studied the effect of oxidation-reduction potential (ORP) in the anoxic sludge zone on the excess sludge production in the oxic-settling-anoxic process (OSA process), a modified activated sludge process. Two pilot-scale activated sludge systems were employed in this study: (1) an OSA process that was modified from a conventional activated sludge process by inserting a sludge holding tank or namely the "anoxic" tank in the sludge return line; and (2) a conventional process used as the reference system. Each was composed of a membrane bioreactor to serve the aeration tank and solid/liquid separator. Both systems were operated with synthetic wastewater for 9 months. During the operation, the OSA system was operated with different ORP levels (+100 to -250 mV) in its anoxic tank. It has been confirmed that the OSA system produced much less excess sludge than the reference system. A lower ORP level than +100 mV in the anoxic tank is in favor of the excess sludge reduction. When the ORP level decreased from +100 to -250 mV the sludge reduction efficiency was increased from 23% to 58%. It has also been found that the OSA system performed better than the reference system with respect to the chemical oxygen demand removal efficiency and sludge settleability. The OSA process may present a potential low-cost solution to the excess sludge problem in an activated sludge process because addition of a sludge holding tank is only needed.  相似文献   

2.
Nitrogen control in AO process with recirculation of solubilized excess sludge   总被引:10,自引:0,他引:10  
Cui R  Jahng D 《Water research》2004,38(5):1159-1172
In order to establish a sludgeless process with a nitrogen-controlled effluent, batch and continuous experiments in a lab scale anoxic-oxic (AO) process were carried out to investigate the possibility of ozonized sludge (OS) usage as a denitrification energy source. Through ozonation at an ozone dose of 1.2g O(3)/g MLVSS, 63.2% of treated MLVSS was solubilized, 12.7% of COD was lost (probably due to complete oxidation to CO(2)), and soluble COD/TN ratio of OS appeared to be only about 10.78 because ozonation released cellular proteins and other nitrogenous substances. In oxic conditions, incubation of OS supernatant with activated sludge generated nitrate without significant ammonia accumulation, which meant that rapid nitrification occurred following ammonia generation from heterotrophic degradation of nitrogen-bearing cellular substances. In anoxic conditions, externally supplied nitrate was removed at the expense of organic carbons in the OS supernatant. However, ammonia was accumulated as anoxic incubation proceeded probably because of heterotrophic degradation of nitrogenous materials as in oxic conditions. Thus it was appeared that solubilized excess sludge acted as a reducing power for denitrification but also as a nitrogen source. In addition, 24-41% of COD contained in OS supernatant were found to be consumed for denitrification. But the remaining COD was not assimilated further even in the presence of nitrate. It was concluded by a nitrogen balance analysis that the energy source contained in OS was not sufficient to completely reduce the nitrogen that was originated from OS itself to nitrogen gas.  相似文献   

3.
Chen GH  An KJ  Saby S  Brois E  Djafer M 《Water research》2003,37(16):3855-3866
Modification of a conventional activated sludge process by inserting a sludge holding tank in a sludge return line forms an oxic-settling-anaerobic (OSA) process that may provide a cost-effective way to reduce excess sludge production in activated sludge processes. In this paper we systematically evaluate the following possible scenarios that may explain the reduction of excess sludge in the OSA process: (i). energy uncoupling, (ii). domination of slow growers, (iii). soluble microbial products (SMPs) effect and (iv). sludge decay in the sludge holding tank under a low oxidation-reduction potential (ORP) condition. Results show that only the final scenario may reasonably explain this reduction. It has also been found that the sludge decay process in the sludge holding tank may involve the reduction of the cell mass.  相似文献   

4.
The treatment and disposal of excess sludge represents a bottleneck in wastewater treatment plants (WWTP) worldwide, due to environmental, economic, social and legal factors. The ideal solution to the problem of sludge disposal is to combine sludge reduction with the removal of pollution at the source. This paper presents an overview of the potential of ozonation in sludge reduction. The full-scale application of ozonation in excess sludge reduction is presented. Improvements in the biodegradability of the ozonated sludge were confirmed. The introduction of ozonation into activated sludge did not significantly influence effluent quality but improved the settling properties of the sludge. An operation with a suitable sludge wasting ratio seems to be necessary to prevent accumulation of inorganic and inert particles for long-term operation. Sludge ozonation to reduce excess sludge production may be economical in WWTP which have high sludge disposal costs and operational problems such as sludge foaming and bulking. The recommended ozone dose ranges from 0.03 to 0.05 g O3/g TSS, which is appropriate to achieve a balance between sludge reduction efficiency and cost. An effort to design and optimize an economic sludge reduction process is necessary.  相似文献   

5.
An advanced sewage treatment process has been developed, in which excess sludge reduction by ozonation and phosphorus recovery by crystallization process are incorporated to a conventional anaerobic/oxic (A/O) phosphorus removal process. The mathematical model was developed to describe the mass balance principal at a steady state of this process. Sludge ozonation experiments were carried out to investigate solubilization characteristics of sludge and change in microbial activity by using sludge cultured with feed of synthetic sewage under A/O process. Phosphorus was solubilized by ozonation as well as organics, and acid-hydrolyzable phosphorus (AHP) was the most part of solubilized phosphorus for phosphorus accumulating organisms (PAOs) containing sludge. At solubilization of 30%, around 70% of sludge was inactivated by ozonation. The results based on these studies indicated that the proposed process configuration has potential to reduce the excess sludge production as well as to recover phosphorus in usable forms. The system performance results show that this system is practical, in which 30% of solubilization degree was achieved by ozonation. In this study, 30% of solubilization was achieved at 30 mgO(3)/gSS of ozone consumption.  相似文献   

6.
Benitez FJ  Acero JL  Garcia J  Leal AI 《Water research》2003,37(17):4081-4090
Wastewaters generated in the cork processing industry were treated in continuous reactors by means of single treatments separately-a chemical ozonation and an activated sludge system-and then by both sequential processes-ozonation followed by aerobic degradation, and aerobic degradation followed by ozonation. The removals obtained in the ozonation alone were 12-54%, 65-81%, and 55-89% for the COD, total phenolics, and absorbance at 254 nm, respectively, while the consumed ozone yield ranged from 40% to 61%, and the biodegradability (BOD(5)/COD) varied from an initial 0.60 to final values between 0.68 and 0.93. The optimum hydraulic retention time and ozone partial pressure were 3 h and 3 kPa, respectively. The stoichiometric ratio was 0.56 g of organic substrate degraded per g of ozone consumed, while the rate constants obtained for the ozone disappearance and for the organic matter degradation were 4490 L g COD(-1) h(-1) and 1970 L g O(3)(-1)h(-1) respectively. The presence of hydrogen peroxide or UV radiation in addition to ozone increased the values of organic matter removal as well as the stoichiometric ratio and the rate constants. The aerobic treatment by the activated sludge system yielded COD removals between 13% and 37% for hydraulic retention times between 24 and 96 h, and the Contois model gave values of q(max)=0.14 g COD g VSS(-1)h(-1) and K(1)=22.6 g COD g VSS(-1) for the main kinetic parameters. The sequential processes increased the substrate removal efficiencies in comparison with the individual processes. These enhancements were greater in the aerobic degradation-ozonation sequence than in the ozonation-aerobic degradation sequence.  相似文献   

7.
Minimization of excess sludge production for biological wastewater treatment   总被引:41,自引:0,他引:41  
Excess sludge treatment and disposal currently represents a rising challenge for wastewater treatment plants (WWTPs) due to economic, environmental and regulation factors. There is therefore considerable impetus to explore and develop strategies and technologies for reducing excess sludge production in biological wastewater treatment processes. This paper reviews current strategies for reducing sludge production based on these mechanisms: lysis-cryptic growth, uncoupling metabolism, maintenance metabolism, and predation on bacteria. The strategies for sludge reduction should be evaluated and chosen for practical application using costs analysis and assessment of environmental impact. High costs still limit technologies of sludge ozonation-cryptic growth and membrane bioreactor from spreading application in full-scale WWTPs. Bioacclimation and harmful to environment are major bottlenecks for chemical uncoupler in practical application. Sludge reduction induced by oligochaetes may present a cost-effective way for WWTPs if unstable worm growth is solved. Employing any strategy for reducing sludge production may have an impact on microbial community in biological wastewater treatment processes. This impact may influence the sludge characteristics and the quality of effluent.  相似文献   

8.
In this paper, a simulation benchmark of a pre-denitrifying activated sludge process is utilized in order to evaluate a supervisory aeration volume control strategy. The aeration volume control strategy has also been evaluated in a pilot plant at Hammarby Sj?stad in Stockholm, Sweden. The main idea has been to let the dissolved oxygen (DO) concentration in some of the aerated compartments be determined by a higher level controller driven by the DO concentration in other compartments. In this way, only sensors for measuring the DO concentrations are needed for the decision of time varying DO set-points. The high reliability of such sensors implies robust input values for the proposed control strategy. Moreover, it is known that the respiration rate is affected by the content of substrate and nitrogen in the compartments; therefore, the suggested manipulations of the DO set-points are indirectly determined by the current load into the plant. Compared to constant DO control and a supervisory DO set-point control strategy based on ammonium measurements in the last aerobic compartment, the suggested aeration volume control strategy could reduce the effluent nitrate and ammonium concentrations significantly without increasing the aeration energy.  相似文献   

9.
Patziger M  Kainz H  Hunze M  Józsa J 《Water research》2012,46(7):2415-2424
Secondary settling is the final step of the activated sludge-based biological waste water treatment. Secondary settling tanks (SSTs) are therefore an essential unit of producing a clear effluent. A further important function of SSTs is the sufficient thickening to achieve highly concentrated return sludge and biomass within the biological reactor. In addition, the storage of activated sludge is also needed in case of peak flow events (Ekama et al., 1997). Due to the importance of a high SST performance the problem has long been investigated ( [Larsen, 1977], [Krebs, 1991], [Takács et?al., 1991], [Ekama et?al., 1997], [Freimann, 1999], [Patziger et?al., 2005] and [Bürger et?al., 2011]), however, a lot of questions are still to solve regarding e.g. the geometrical features (inflow, outflow) and operations (return sludge control, scraper mechanism, allowable maximum values of surface overflow rates). In our study we focused on SSTs under dynamic load considering both the overall unsteady behaviour and the features around the peaks, investigating the effect of various sludge return strategies as well as the inlet geometry on SST performance. The main research tool was a FLUENT-based novel mass transport model consisting of two modules, a 2D axisymmetric SST model and a mixed reactor model of the biological reactor (BR). The model was calibrated and verified against detailed measurements of flow and concentration patterns, sludge settling, accompanied with continuous on-line measurement of in- and outflow as well as returned flow rates of total suspended solids (TSS) and water.As to the inlet arrangement a reasonable modification of the geometry could result in the suppression of the large scale flow structures of the sludge-water interface thus providing a significant improvement in the SST performance. Furthermore, a critical value of the overflow rate (qcrit) was found at which a pronounced large scale circulation pattern develops in the vertical plane, the density current in such a way hitting the outer wall of the SST, turning then to the vertical direction accompanied with significant flow velocities. This phenomenon strengthens with the hydraulic load and can entrain part of the sludge thus resulting in unfavourable turbid effluent.As a representative case study an operating circular SST most commonly used in practice was investigated. Focusing on the sludge return strategies, it was found that up to a threshold peak flow rate the most efficient way is to keep the return sludge flow rate constant, at 0.4QMAX. However, once the inflow rate exceeds the threshold value the return sludge flow rate should be slowly increased up to 0.6QMAX, performed in a delayed manner, about 20-30 min after the threshold value is exceeded. For preserving the methodology outlined in the present paper, other types of SSTs, however, need further individual investigations.  相似文献   

10.
11.
Stare A  Vrecko D  Hvala N  Strmcnik S 《Water research》2007,41(9):2004-2014
In this paper several control strategies for nitrogen removal are proposed and evaluated in a benchmark simulation model of an activated sludge process. The goal is to determine which control strategy delivers better performance with respect to plant operating costs. In the study, constant manipulated variables and various PI and feedforward control strategies are tested and compared with predictive control, which uses an ideal process model. The control strategies differ in the information used about the process (number of sensors and sensor location) and in the complexity of the control algorithms. To determine the set-points that yield optimal operating costs, an operational map is constructed for each control strategy. Results of the simulation show that with PI and feedforward controllers almost the same optimal operating costs can be achieved as with more advanced MPC algorithms under various plant operating conditions. More advanced control algorithms are advantageous only in cases where the plant is highly loaded and if stringent effluent fines are imposed by legislation.  相似文献   

12.
Yoon SH  Lee S 《Water research》2005,39(15):3738-3754
Mathematical models were developed to elucidate the relationships among process control parameters and the effect of these parameters on the performance of anoxic/oxic biological wastewater processes combined with sludge disintegrators (A/O-SD). The model equations were also applied for analyses of activated sludge processes hybrid with sludge disintegrators (AS-SD). Solubilization ratio of sludge in the sludge disintegrator, alpha, hardly affected sludge reduction efficiencies if the biomass was completely destructed to smaller particulates. On the other hand, conversion efficiency of non-biodegradable particulates to biodegradable particulates, beta, significantly affected sludge reduction efficiencies because beta was directly related to the accumulation of non-biodegradable particulates in bioreactors. When 30% of sludge in the oxic tank was disintegrated everyday and beta was 0.5, sludge reduction was expected to be 78% and 69% for the A/O-SD and AS-SD processes, respectively. Under this condition, the sludge disintegration number (SDN), which is the amount of sludge disintegrated divided by the reduced sludge, was calculated to be around 4. Due to the sludge disintegration, live biomass concentration decreased while other non-biodegradable particulates concentration increased. As a consequence, the real F/M ratio was expected to be much higher than the apparent F/M. The effluent COD was maintained almost constant for the range of sludge disintegration rate considered in this study. Nitrogen removal efficiencies of the A/O-SD process was hardly affected by the sludge disintegration until daily sludge disintegration reaches 40% of sludge in the oxic tank. Above this level of sludge disintegration, autotrophic biomass concentration decreases overly and TKN in the effluent increases abruptly in both the A/O-SD and AS-SD processes. Overall, the trends of sludge reduction and effluent quality according to operation parameters matched well with experimental results found in literatures.  相似文献   

13.
Kim YM  Chon DH  Kim HS  Park C 《Water research》2012,46(13):4292-4300
The goal of this study was to investigate the bacterial community in activated sludge with an anaerobic side-stream reactor (ASSR), a process permitting significant decrease in sludge production during wastewater treatment. The study operated five activated sludge systems with different sludge treatment schemes serving as various controls for the activated sludge with ASSR. Bacterial communities were analyzed by denaturing gradient gel electrophoresis (DGGE), sequencing and construction of phylogenetic relationships of the identified bacteria. The DGGE data showed that activated sludge incorporating ASSR contained higher diversity of bacteria, resulting from long solids retention time and recirculation of sludge under aerobic and anaerobic conditions. The similarity of DGGE profiles between ASSR and separate anaerobic digester (control) was high indicating that ASSR is primarily related to conventional anaerobic digesters. Nevertheless, there was also unique bacteria community appearing in ASSR. Interestingly, sludge in the main system and in ASSR showed considerably different bacterial composition indicating that ASSR allowed enriching its own bacterial community different than that from the aeration basin, although two reactors were connected via sludge recirculation. In activated sludge with ASSR, sequences represented by predominant DGGE bands were affiliated with Proteobacteria. The remaining groups were composed of Spirochaetes, Clostridiales, Chloroflexi, and Actinobacteria. Their putative role in the activated sludge with ASSR is also discussed in this study.  相似文献   

14.
Hedegärd M  Wik T 《Water research》2011,45(19):6308-6320
The activated sludge process for degradation of organic matter is one of the main processes commonly used in biological wastewater treatment, and aeration in that process stands for a large part of the energy consumed in a plant. Hence, there have been many attempts to improve the operation of the activated sludge process using mathematical models of the process. The advanced models used has in general their origin in IWA (former IAWQ) activated sludge model no 1 (ASM1). Unfortunately, optimization w.r.t. discharge and economy is limited for municipal wastewater treatment plants because several of the most important variables; heterotrophic biomass, readily biodegradable soluble substrate, and slowly biodegradable substrate cannot be reliably measured online because of their complexity hiding behind their notation. With the predenitrifying WWTP in Göteborg having post nitrification in trickling filters as an example, we resolve this problem by deriving an observer that estimates these concentrations in the aerobic parts based on only the commonly available online measurements of oxygen, water flows, TSS concentration and supplied air. Based on control theory analysis and simulations it is concluded that estimation does not work for an activated sludge process with aeration in one stirred tank alone, but when the activated sludge process can be described by at least two tanks in series, with oxygen measurements in each tank, the estimates converge. A sensitivity analysis with respect to deviations in model parameters reveals that the derived estimator is also fairly robust to model errors.  相似文献   

15.
In current activated sludge models aerobic degradation, resulting in loss of activity and mass of activated sludge is expressed with only one process called decay. The kinetics of this process is regarded to be first order and constant with respect to the loading conditions. In this work twelve aerobic digestion batch experiments were conducted for the activated sludge of seven different water resource recovery facilities (WRRFs). An analysis of the obtained respirograms shows three clearly distinguishable phases. The first phase is assumed to be due to the degradation of stored material (XSTOR) and active biomass simultaneously. The second phase is exclusively due to the degradation of active biomass that is regarded to consist mainly of ordinary heterotrophic biomass (XOHO). The first order decay rate is slower than the degradation rate in phase 1 and varies between samples. The decay rate correlates with the activity of the activated sludge expressed as the ratio of initial heterotrophic OUR and the initial organic fraction XORG of the activated sludge. This second phase was detectable until day 5 of most of the experiments. After that time within phase 3 the OUR decrease slows down and the OUR even increased for short intervals. This behaviour is thought to be due to the activity of higher organisms and the adaptation of microorganisms to starvation.  相似文献   