首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this study, electricity and hydrogen production of an integrated system with energy and exergy analyses are investigated. The system also produces clean water for the water electrolysis system. The proposed system comprises evacuated tube solar collectors (ETSCs), parabolic trough solar collectors (PTSCs), flash turbine, organic Rankine cycles (ORC), a reverse osmosis unit (RO), a water electrolysis unit (PEM), a greenhouse and a medium temperature level geothermal resource. The surface area of each collector is 500 m2. The thermodynamics analysis of the integrated system is carried out under daily solar radiation for a day in August. The fluid temperature of the medium temperature level geothermal resource is upgraded by ETSCs and PTSCs to operate the flash turbine and the ORCs. The temperature of the geothermal fluid is upgraded from 130 °C to 323.6 °C by the ETSCs and PTSCs. As a result, it is found that the integrated system generates 162 kg clean water, 1215.63 g hydrogen, and total electrical energy of 2111.04 MJ. The maximum energy and exergy efficiencies of the overall system are found as 10.43% and 9.35%, respectively.  相似文献   

2.
In this study, power and hydrogen production performance of an integrated system is investigated. The system consists of an organic Rankine cycle (ORC), parabolic trough solar collectors (PTSCs) having a surface area of 545 m2, middle-grade geothermal source (MGGS), cooling tower and proton exchange membrane (PEM). The final product of this system is hydrogen that produced via PEM. For this purpose, the fluid temperature of the geothermal source is upgraded by the solar collectors to drive the ORC. To improve the electricity generation efficiency, four working fluids namely n-butane, n-pentane, n-hexane, and cyclohexane are tried in the ORC. The mass flow rate of each working fluid is set as 0.1, 0.2, 0.3, 0.4 kg/s and calculations are made for 16 different situations (four types of working fluids and four different mass flow rates for each). As a result, n-butane with a mass flow rate of 0.4 kg/s is found to be the best option. The average electricity generation is 66.02 kW between the hours of 1100-1300. The total hydrogen production is 9807.1 g for a day. The energy and exergy efficiency is calculated to be 5.85% and 8.27%, respectively.  相似文献   

3.
In present study, hydrogen production performance of chlor-alkali cell integrated into a power generation system based on geothermal resource is studied. The basic elements of the novel system are a separator, a steam power turbine, an organic Rankine cycle (ORC), an air cooled condenser, a saturated NaCl solution reservoir tank and a chlor-alkali cell. To enhance the performance of the cell, the saturated NaCl solution is heated by the waste heat from the ORC. So, this integrated system generates significant amount of electricity for the city grid and also yields three main products those are hydrogen, chlorine and sodium hydroxide. According to the parametric study, when the temperature of a geothermal resource varies from 140 to 155 °C, the electrical power generation increases from nearly 2.5 MW to 3.9 MW and hydrogen production increases from 10.5 to 21.1 kg-h. Thus, when the geothermal resource temperature of 155 °C, the energy efficiency of the system is 6.2% and the exergetic efficiency is 22.4%. As a result, the geothermal energy potential plays a key role on the integrated system performance and the hydrogen production rate.  相似文献   

4.
In this work, a unified renewable energy system has designed to assess the electricity and hydrogen production. This system consists of the evacuated tube solar collectors (ETSCs) which have the total surface area of 300 m2, a salt gradient solar pond (SGSP) which has the surface area of 217 m2, an Organic Rankine Cycle (ORC) and an electrolysis system. The stored heat in the heat storage zone (HSZ) transferred to the input water of the ETSCs by means of an exchanger and thereby ETSCs increase the temperature of preheated water to higher level as much as possible that primarily affects the performance of the ORC. The balance equations of the designed system were written and analyzed by utilizing the Engineering Equations Solver (EES) software. Hence, the energy and exergy efficiencies of the overall system were calculated as to be 5.92% and 18.21%, respectively. It was also found that hydrogen generation of the system can reach up to ratio 3204 g/day.  相似文献   

5.
In this paper, a combined power plant based on the dish collector and biomass gasifier has been designed to produce liquefied hydrogen and beneficial outputs. The proposed solar and biomass energy based combined power system consists of seven different subplants, such as solar power process, biomass gasification plant, gas turbine cycle, hydrogen generation and liquefaction system, Kalina cycle, organic Rankine cycle, and single-effect absorption plant with ejector. The main useful outputs from the combined plant include power, liquid hydrogen, heating-cooling, and hot water. To evaluate the efficiency of integrated solar energy plant, energetic and exergetic effectiveness of both the whole plant and the sub-plants are performed. For this solar and biomass gasification based combined plant, the generation rates for useful outputs covering the total electricity, cooling, heating and hydrogen, and hot water are obtained as nearly 3.9 MW, 6584 kW, 4206 kW, and 0.087 kg/s in the base design situations. The energy and exergy performances of the whole system are calculated as 51.93% and 47.14%. Also, the functional exergy of the whole system is calculated as 9.18% for the base working parameters. In addition to calculating thermodynamic efficiencies, a parametric plant is conducted to examine the impacts of reference temperature, solar radiation intensity, gasifier temperature, combustion temperature, compression ratio of Brayton cycle, inlet temperature of separator 2, organic Rankine cycle turbine and pump input temperature, and gas turbine input temperature on the combined plant performance.  相似文献   

6.
In the presented paper, energy and exergy analysis is performed for thermochemical hydrogen (H2) production facility based on solar power. Thermal power used in thermochemical cycles and electricity production is obtained from concentrated solar power systems. In order to investigate the effect of thermochemical cycles on hydrogen production, three different cycles which are low temperature Mg–Cl, H2SO4 and UT-3 cycles are compared. Reheat-regenerative Rankine and recompression S–CO2 Brayton power cycles are considered to supply electricity needed in the Mg–Cl and H2SO4 thermochemical cycles. Furthermore, the effects of instant solar radiation and concentration ratio on the system performance are investigated. The integration of S–CO2 Brayton power cycle instead of reheat-regenerative Rankine enhances the system performance. The maximum exergy efficiency which is obtained in the system with Mg–Cl thermochemical and recompression S–CO2 Brayton power cycles is 27%. Although the energy and exergy efficiencies decrease with the increase of the solar radiation, they increase with the increase of the concentration ratio. The highest exergy destruction occurred in the solar energy unit.  相似文献   

7.
In this paper, a new renewable energy-based cogeneration system for hydrogen and electricity production is developed. Three different methods for hydrogen production are integrated with Rankine cycle for electricity production using solar energy as an energy source. In addition, a simple Rankine cycle is utilized for producing electricity. This integrated system consists of solar steam reforming cycle using molten salt as a heat carrier, solar steam reforming cycle using a volumetric receiver reactor, and electrolysis of water combined with the Rankine cycle. These cycles are simulated numerically using the Engineering Equation Solver (EES) based on the thermodynamic analyses. The overall energetic and exergetic efficiencies of the proposed system are determined, and the exergy destruction and entropy generation rates of all subcomponents are evaluated. A comprehensive parametric study for evaluating various critical parameters on the overall performance of the system is performed. The study results show that both energetic and exergetic efficiencies of the system reach 28.9% and 31.1%, respectively. The highest exergy destruction rates are found for the steam reforming furnace and the volumetric receiver reforming reactor (each with about 20%). Furthermore, the highest entropy generation rates are obtained for the steam reforming furnace and the volumetric receiver reforming reactor, with values of 174.1 kW/K and 169.3 kW/K, respectively. Additional parametric studies are undertaken to investigate how operating conditions affect the overall system performance. The results report that 60.25% and 56.14% appear to be the highest exergy and energy efficiencies at the best operating conditions.  相似文献   

8.
In this study, the hydrogen production performance of a reactor assisted by a solar pond by photoelectrochemical method is examined conceptually. The main components of the new integrated system are a solar pond, a photovoltaic panel (PV) and a hybrid chlor-alkali reactor which consists of a semiconductor anot, photocathode and cation exchange membrane. The proposed system produces hydrogen via water splitting reaction and also yields the by products namely chlorine and sodium hydroxide while consumes saturated NaCl solution and pure water. In order to increase the efficiency of the reactor, the saturated hot NaCl solution at the heat storage zone (HSZ) of the solar pond is transferred to the anot section and the heated pure water by heat exchanger in the HSZ is transferred to cathode section. The photoelectrode releases electrons for hydrogen production with diminishing the power requirement from the PV panel that is used as a source of electrical energy for the electrolysis. The results confirm that the thermal performance of the solar pond plays a key role on the hydrogen production efficiency of the reactor.  相似文献   

9.
阐述了光解水制氢的原理,介绍了光解水制氢技术的现状,分析了目前光解水制氢技术存在的问题以及提高光解水效率的有效途径,指出了利用光热化学循环进行光解水制氢的新途径.  相似文献   

10.
The present study develops a new solar and geothermal based integrated system, comprising absorption cooling system, organic Rankine cycle (ORC), a solar-driven system and hydrogen production units. The system is designed to generate six outputs namely, power, cooling, heating, drying air, hydrogen and domestic hot water. Geothermal power plants emit high amount of hydrogen sulfide (H2S). The presence of H2S in the air, water, soils and vegetation is one of the main environmental concerns for geothermal fields. In this paper, AMIS(AMIS® - acronym for “Abatement of Mercury and Hydrogen Sulphide” in Italian language) technology is used for abatement of mercury and producing of hydrogen from H2S. The present system is assessed both energetically and exergetically. In addition, the energetic and exergetic efficiencies and exergy destruction rates for the whole system and its parts are defined. The highest overall energy and exergy efficiencies are calculated to be 78.37% and 58.40% in the storing period, respectively. Furthermore, the effects of changing various system parameters on the energy and exergy efficiencies of the overall system and its subsystems are examined accordingly.  相似文献   

11.
In this paper, we propose an integrated system aiming for hydrogen production with by-products using geothermal power as a renewable energy source. In analyzing the system, an extensive thermodynamic model of the proposed system is developed and presented accordingly. In addition, the energetic and exergetic efficiencies and exergy destruction rates for the whole system and its parts are defined. Due to the significance of some parameters, the impacts of varying working conditions are also investigated. The results of the energetic and exergetic analyses of the integrated system show that the energy and exergy efficiencies are 39.46% and 44.27%, respectively. Furthermore, the system performance increases with the increasing geothermal source temperature and reference temperature while it decreases with the increasing pinch point temperature and turbine inlet pressure.  相似文献   

12.
This paper presents the analytical study of flat plate collector based on the computer‐based thermal models considering two different cases, case A (fully covered by glass) and case B (fully covered by photovoltaic (PV) module). These models are developed based on energy balance equations. An analytical expression for characteristic equation for photovoltaic–thermal flat plate collector has been derived as a function of design and climatic parameters. This paper shows the detailed analysis of energy, exergy and electrical energy by varying the number of collectors by considering four weather conditions (A, B, C and D type) for five different cities (New Delhi, Bangalore, Mumbai, Srinagar and Jodhpur) of India. It is observed that the collectors fully covered by PV module combine the production of hot water in addition to electricity generation and it is beneficial in terms of exergy, thermal energy and electrical energy gain. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

13.
In the current study, an experimental analysis of exergy performance for different absorber plates is done. Three types of absorber plates are supplied with different fin arrangements with a variable air mass flow rate. The exergy analysis to evaluate the exergy performance of the solar air heaters uses experimental data for conventional and finned solar air collectors with different arrangements of fins. The main aim of the current study is to compare the exergy performance of the conventional solar air collector with those equipped with fins. The introducing of the fins in different arrangements enhances the absorber surface area, which leads to increased heat transfer. Also, fins induce air turbulence in the flow field, which improves the exergy performance of solar air collector. It is found that the exergy reduces and exergy efficiency enhances with increasing the airflow rate. The traditional flat absorber plate has undesirable exergy loss and exergy efficiency for all ranges of airflow rates. Thus, the flat plate collector presents the most substantial irreversibility, for which the exergy efficiency is the least. However, the results show that the exergy efficiency of inclined staggered turbulators is higher than that of in‐line and staggered turbulators. The optimal value of exergy efficiency is recorded at nearly 77% for the solar air collectors equipped with inclined staggered turbulators compared with other types of configurations.  相似文献   

14.
In this work, a new model for producing hydrogen from a low enthalpy geothermal source was presented. Thermal energy from geothermal sources can be converted into electric power by using thermoelectric modules instead of Organic Rankine Cycle (ORC) machines, especially for low geothermal temperatures. This electrical energy uses the water electrolysis process to produce hydrogen. Simulation and experiments for the thermoelectric module in this system were undertaken to assess the efficiency of these models. TRNSYS software is used to simulate the system in Hammam Righa spa, the temperature of this spring is 70 °C. Obtained results reveal that in hammam righa spa in Algeria, 0.5652 Kg hydrogen per square meter of thermoelectric generator (TEG) can be produced in one year.  相似文献   

15.
In this study, the detailed thermodynamic assessment of an integrated process based on heat pipe evacuated tube solar collectors for hydrogen production is provided for more efficiently process designs. An integrated process consists of the solar heat pipe collector, photovoltaic panels, PEM electrolyzer and Linde-Hampson hydrogen liquefaction process are considered and analyzed thermodynamically for hydrogen production and liquefaction aims. The energetic and exergetic efficiencies of this integrated process are calculated as 0.2297 and 0.1955, respectively. Based on the parametric study, the effectiveness of the solar energy based integrated process is also highly dependent on the solar flux and ambient conditions.  相似文献   

16.
In this study, a new solar and geothermal based integrated system is developed for multigeneration of electricity, fresh water, hydrogen and cooling. The system also entails a solar integrated ammonia fuel cell subsystem. Furthermore, a reverse osmosis desalination system is used for fresh water production and a proton exchange membrane based hydrogen production system is employed. Moreover, an absorption cooling system is utilized for district cooling via available system waste heat. The system designed is assessed thermodynamically through approaches of energy and exergy analyses. The overall energy efficiency is determined to be 42.3%. Also, the overall exergy efficiency is assessed, and it is found to be 21.3%. The exergy destruction rates in system components are also analysed and the absorption cooling system generator as well as geothermal flash chamber are found to have comparatively higher exergy destruction rates of 2370.2 kW and 643.3 kW, respectively. In addition, the effects of varying system parameters on the system performance are studied through a parametric analyses of the overall system and associated subsystems.  相似文献   

17.
The use of ground-source heat pumps for heating and domestic hot water in dwellings is common in Sweden. The combination with solar collectors has been introduced to reduce the electricity demand in the system.  相似文献   

18.
In this study, the energetic and exergetic efficiencies of a salt gradient cylindrical solar pond (SGCSP) that integrated and nonintegrated evacuated tube solar collectors (ETSCs) are investigated to improve daily heat preservation performance of the heat storage zone (HSZ). The integrated system is consisted of an SGCSP and four ETSCs. The SGCSP has a surface area of 2 m2, a depth of 1.65 m, salty water layers at different densities, and HSZ in which the cylindrical serpentine type heat exchanger (CSHE) is located. Thus, the daily effects of the heat storage performance of both the ETSCs and the SGCSP in the winter season was determined experimentally. The analysis of the data regarding the efficiencies of the system is investigated separately by means of experimental studies where the SGCSP is integrated and nonintegrated with the ETSCs. The number of ETSCs integrated with SGCSP is increased to 1, 2, 3, and 4, respectively, and each of the five different experimental systems is performed separately. The temperature distributions of the integrated system are measured by a data acquisition system on 11 different points per hour. The efficiencies are calculated using the data obtained from these studies. Consequently, the energetic and exergetic efficiencies of the SGCSP are obtained without collectors as 10.4% and 4.3% and with one collector as 12.83% and 6.15%, with two collectors 14.88% and 8.25%, with three collectors 16% and 9.35%, and finally with four collectors 16.94% and 10.3%, respectively. Furthermore, the theoretical efficiencies are found to be consistent with the experimental results obtained by increasing the collector numbers.  相似文献   

19.
In this paper, thermodynamic analysis and assessment of a novel geothermal energy based integrated system for power, hydrogen, oxygen, cooling, heat and hot water production are performed. This integrated process consists of (a) geothermal subsystem, (b) Kalina cycle, (c) single effect absorption cooling subsystem and (d) hydrogen generation and storage subsystems. The impacts of some design parameters, such as absorption chiller evaporator temperature, geothermal source temperature, turbine input pressure and pinch point temperature on the integrated system performance are investigated to achieve more efficient and more effective. Also, the impacts of reference temperature and geothermal water temperature on the integrated system performance are studied in detail. The energetic and exergetic efficiencies of the integrated system are then calculated as 42.59% and 48.24%, respectively.  相似文献   

20.
The study aims to optimize the geothermal and solar-assisted sustainable energy and hydrogen production system by considering the genetic algorithm. The study will be useful by integrating hydrogen as an energy storage unit to bring sustainability to smart grid systems. Using the Artificial Neural Network (ANN) based Genetic Algorithm (GA) optimization technique in the study will ensure that the system is constantly studied in the most suitable under different climatic and operating conditions, including unit product cost and the plant's power output. The water temperature of the Afyon Geothermal Power Plant varies between 70 and 130 °C, and its mass flow rate varies between 70 and 150 kg/s. In addition, the solar radiation varies between 300 and 1000 W/m2 for different periods. The net power generated from the region's geothermal and solar energy-supported system is calculated as 2900 kW. If all of this produced power is used for hydrogen production in the electrolysis unit, 0.0185 kg/s hydrogen can be produced. The results indicated that the overall energy and exergy efficiencies of the integrated system are 4.97% and 16.0%, respectively. The cost of electricity generated in the combined geothermal and solar power plant is 0.027 $/kWh if the electricity is directly supplied to the grid and used. The optimized cost of hydrogen produced using the electricity produced in geothermal and solar power plants in the electrolysis unit is calculated as 1.576 $/kg H2. The optimized unit cost of electricity produced due to hydrogen in the fuel cell is calculated as 0.091 $/kWh.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号