首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
Transcranial Doppler studies on the effects of sumatriptan on cerebral hemodynamics have shown conflicting results. We evaluated blood flow velocity changes in 21 patients suffering from migraine with (n = 4) or without aura (n = 17) during a spontaneous attack, before and after treatment with sumatriptan. Flow velocity in the internal and external carotid, middle cerebral, and basilar arteries was measured by means of transcranial Doppler. During the attack, measurements were taken before subcutaneous sumatriptan injection, then after 30 minutes, 2 hours, and 24 hours. An additional measurement was taken 1 week later, in a headache-free state. We found a significant reduction of flow velocity during the attack in the middle cerebral artery on both sides (P < 0.05). After sumatriptan administration, flow velocity increased in the internal carotid artery on both sides (P < 0.05) and in the middle cerebral artery on the headache side (P = 0.0001), but not in the external carotid and basilar arteries (P > 0.05). Flow velocity changes may reflect the vasodilation present at the onset of the migraine attack followed by vasoconstriction in the internal carotid and middle cerebral arteries after sumatriptan treatment. Since vasoconstriction occurs in responders and nonresponders to treatment, it is unlikely to be the primary mechanism by which sumatriptan relieves headache.  相似文献   

3.
BACKGROUND AND PURPOSE: The vasomotor response can be tested by means of transcranial Doppler sonography. If a constant vessel diameter is assumed, the flow velocity changes will reflect blood flow volume changes. This hypothesis is difficult to verify. Simultaneous assessment of intracranial flow velocity and extracranial flow volume changes may solve this problem. METHODS: We tested vasomotor response in 32 volunteers (age, 42+/-18 years) with 5% CO2. Acetazolamide (1 g) was tested in 15 volunteers (age, 28+/-8 years). To evaluate drug-dependent flow changes in the external carotid artery territory, acetazolamide was administered in 7 patients with unilateral occlusion of the internal carotid artery without evidence of collateralization through the ophthalmic artery (age, 67+/-12 years). Simultaneous recording included measurements of flow volume in the common carotid arteries (M-mode color duplex system) and flow velocity in the middle cerebral arteries. RESULTS: With CO2 and acetazolamide, intracranial flow velocity increased by 31% and 39%, respectively, with a simultaneous increase of common carotid artery flow volume of 47% and 50%, respectively. No change in extracranial flow volume was observed in patients with an occluded internal carotid artery. CONCLUSIONS: These data show not only the expected increase of flow velocity in the middle cerebral artery but also suggest an increase in cross-sectional vessel diameter of 6% and 4% with CO2 and acetazolamide, respectively. It remains unresolved whether this observation is due to a direct effect of the drug on the vessel walls or is simply pressure dependent.  相似文献   

4.
The Doppler examination of the carotid arteries in the neck was compared with the results of the examination of the supratrochlear artery and of the angiographic controls in 76 patients. The results of this study indicate that the insonation of the carotid arteries considerably improves the diagnostic possibilities offered by the examination of the supratrochlear artery alone. There are three main advantages: 1. The reliability of the Doppler examination is improved. The insonation of the carotid arteries of the 76 angiographically controlled patients including stenoses from 50% onward gave only one false-positive and one false-negative result. The percentage of correct diagnoses thereby attained was 97%. 2. The insonation of the carotid arteries permits reliable differentiation between stenoses and occlusions. This is not possible by the insonation of the supratrochlear artery alone. There was only one case in which the distinction was wrong. 3. The localization of the pathologic process was possible in all cases. These conclusions are only valid for the detection of occlusions and stenoses of more than 50%. Low degree stenoses cannot be detected by this method.  相似文献   

5.
Central retinal artery and orbital artery were examined by ultrasonograph in 348 patients with atherosclerosis of the carotid arteries. Doppler shift of frequency spectrum was detected in the central retinal artery, which is typical of the ischemic syndrome of the eye. Its characteristics include decreased diastolic component of velocity and increased resistance index. The possibility of using duplex scanning with color Doppler flow mapping for assessing the treatment efficacy is demonstrated. A direct relationship between the degree of stenosis in the internal carotid artery and blood flow in the orbital artery is revealed. The detected changes do not notably affect the Doppler spectrum characteristics in the central retinal artery.  相似文献   

6.
PURPOSE: To determine whether ultrasound (US) is a sensitive follow-up method after placement of a carotid artery stent for the detection of significant stenosis, occlusion, and other complications at early and intermediate follow-up. MATERIALS AND METHODS: Doppler US examinations were performed after stent placement in 170 carotid arteries in 119 patients with angiographic correlation. Prospective diagnostic US criteria for stenosis were peak-systolic velocity greater than 1.25 m/sec, internal carotid artery (ICA) to common carotid artery (CCA) peak-systolic velocity ratio of greater than or equal to 3:1, and intrastent doubling of peak-systolic velocity. Retrospective criteria for stenosis were also applied: peak-systolic velocity greater than 1.7 m/sec, ICA end-diastolic velocity greater than 0.4 m/sec, ICA/CCA peak-systolic velocity ratio greater than 2.0, and ICA/CCA end-diastolic velocity ratio greater than 2.4. RESULTS: Eighty-seven immediate and 83 intermediate (average, 7.3 months) follow-up US examinations were performed. Two stent occlusions were detected. One or more prospective US criteria were abnormal in 26 arteries with a stent. One or more retrospective criteria were positive in 47 arteries. Angiography showed corresponding findings, with only one significant stenosis (63%) in the ICA stents. Moderate collapse of a CCA stent was depicted at US. CONCLUSION: Only one significant recurrent stenosis was detected, and no significant stenoses were missed at US. US successfully depicted carotid artery stent occlusion and a moderate stent collapse. Sensitivity in the detection of intrastent stenosis is promising. Further study to refine US criteria in a study with longer term follow-up is needed owing to the lack of significant recurrent stenosis in the intermediate follow-up group.  相似文献   

7.
Chronically implanted ultrasonic Doppler flowmeters were used to obtain simultaneously recorded flow velocity signals from internal carotid and vertebral arteries, and the sagittal sinus, in rabbits. All three signals increased to 144 +/- 7-215 +/- 35% of baseline during hypercapnia (arterial Pco2 55 mmHg) in both anesthetized and conscious animals. During the period of change in inspired CO2, the relationship between simultaneously recorded mean internal carotid and mean sagittal sinus signals was linear, with the correlation ranging from 0.83 to 0.96. Since forebrain arterial inflow must approximate forebrain venous outflow, the high correlation between internal carotid and sagittal sinus signals indicates that these measures provide reliable and valid indices of cerebral blood flow (CBF). Vertebral and internal carotid angiography confirmed the location of Doppler probe. Chronically implanted ultrasonic Doppler flowmeters can, thus, provide continuous noninvasive measurements of cerebral arterial flow in both anesthetized and conscious rabbits.  相似文献   

8.
The Doppler examination of the vertebral and subclavian arteries was compared with the angiographic findings in 40 cases. The vertebral flow was recorded at its atlas slope, the subclavian artery at the supraclavicular fossa. Twenty-seven normal Doppler results were confirmed by angiography in 26 cases. In one case there was a 70% stenosis at the origin of the vertebral artery. Occlusions, stenoses, and severe hypoplasia of the vertebral artery can be detected, but not distinguished from each other by the Doppler examination. Diagnostically relevant findings are either nondetectable flow above the vertebral artery or only minor pulsations with amplitudes less than 25% of the normal side. Eleven cases showed a flow reversal in a vertebral artery. Five of them were angiographically controlled and all showed a typical subclavian steal syndrome. Although the precision of the results of the examination of the vertebral artery is not as good as for the carotid arteries, it is a rough, suitable atraumatic screening method particularly for the subclavian steal syndrome.  相似文献   

9.
BACKGROUND AND PURPOSE: We compared the results of conventional angiography, carotid Doppler, and magnetic resonance angiography volume flow rates to determine the clinical utility of volume flow rate assessment of blood flow to the anterior circulation in patients with carotid occlusive disease. METHODS: From 11 symptomatic patients, a total of 22 extracranial carotid arteries were studied with all three techniques. The studies were independently read, and regression analysis was used to compare the measurements. RESULTS: Carotid Doppler measurements of the distal extracranial carotid arteries were proportional to the inverse of the extracranial carotid volume flow rate (r = .53, R2 = 29%, P < .01), volume flow rates were proportional to the inverse of measured percent stenosis on angiography (r = .84, R2 = 71%, P < .01), and Dopplers were proportional to angiography (r = .94, R2 = 90%, P < .01). Symptomatic Doppler systolic velocity was significantly higher (P < .002), symptomatic measured stenosis was significantly higher (P < .002), and symptomatic volume flow rate was significantly lower (P < .01) than their respective asymptomatic-side values. These preliminary observations, however, may well change once a large data set, especially one in which more patients with high-grade carotid stenosis are included, is studied. CONCLUSIONS: Assessment of carotid volume flow rates by magnetic resonance angiography quantifies flow reduction secondary to atherosclerotic occlusive disease. The easily obtained flow data add both documentation of arterial flow characteristics related to internal carotid stenosis and information regarding the adequacy of collateral pathways.  相似文献   

10.
Vertebro-basilar circulation is complex because conditioned by several factors. Ultrasounds allow the study of many of its aspect, both hemodynamic and anatomical. Data were obtained from the examination of 50,000 patients over 25 years, of which the last 1,000 patients were examined by means of transcranial Doppler, duplex scanner color and power. 40% of these patients were found normal, 20% only had arterial thickening, 26% various types of stenosis, 10.6% subclavian steal, 14% short vertigo. The basilar artery (BA) flow (230 ml/min +/- 40) is similar to that of the internal carotid (245 ml/min +/- 50). In elderly patients, the absence of a posterior communicating artery (28%) or of both arteries (13%) is more frequent than the absence of the anterior communicating artery (7%). In normal patients decubitus variations do not modify the BA flow. In patients with vertigo due to decubitus variations, BA flow velocity increases from 20% to 40% during vertigo. Subclavian steal completely modifies the hemodynamics of vertebral arteries, while in the BA it can vary in part or completely. In conclusion, vertebral hemodynamics is different from BA hemodynamics. BA must be considered as one side of the Willis' polygon because it is an anastomosis between the vertebral arteries and is a "hemodynamic damper" between intracranial and extracranial circulation.  相似文献   

11.
Transcranial Doppler ultrasonography is a useful method for the estimation and monitoring of cerebral circulation in dialyzed patients. The aim of this study was to evaluate the effect of disease and treatment on cerebral circulation in children on maintenance hemodialysis (HD) and children prior to renal replacement therapy. We demonstrated that in uremic children blood flow velocities of the internal carotid artery (ICA), anterior cerebral artery (ACA), middle cerebral artery (MCA), and posterior cerebral artery (PCA) 120 min and 240 min from the beginning of an HD session were significantly lower than values immediately before HD. Changes in blood flow velocities of MCA and ACA during HD correlated significantly with changes in mean arterial pressure during HD. There was no correlation between changes in blood flow velocities and intradialytic changes in hematocrit values, ultrafiltration, hemoglobin concentration, and blood urea nitrogen values. Mean blood flow velocities of ICA, MCA, and PCA in euvolemic children on conservative treatment were significantly higher than after a HD session in children on maintenance HD. The factors responsible for intradialytic velocity changes of cerebral arteries in uremic children require further examination.  相似文献   

12.
Coronary angiography incompletely delineates the physiologic consequences of many epicardial stenoses. Intracoronary translesional flow velocity measurements using the Doppler flow wire during cardiac catheterization provide immediate data discriminating the physiologic significance of coronary stenoses. The validity and accuracy of the flow wire for analyzing lesion hemodynamic significance have been confirmed in multiple studies. Flow velocity analysis provides objective criteria for refining the selection of cases for revascularization, and prospective clinical data have confirmed the safety of deferring intervention on lesions with normal physiologic assessment. Translesional and distal coronary flow velocity dynamics during procedures also provide immediate data assessing the physiologic adequacy of intervention. Impaired postintervention distal coronary flow velocity and vasodilator reserve can predict subsequent clinical events, and comparisons of flow velocity indices prestenting and poststenting suggest that physiologically inadequate results of angioplasty may be improved by additional intervention. Flow velocity assessment may also have utility in profiling the adequacy of infarct artery reperfusion following acute myocardial infarction. Evidence has been accumulated to support use of Doppler flow velocity analysis as a clinically relevant technique for improving both diagnostic and therapeutic aspects of cardiovascular medicine.  相似文献   

13.
Two-dimensional ultrasonography was used in combination with colour-flow imaging and pulsed wave Doppler ultrasonography to study the maternal circulation and the development of fetal vascularization in six Beagles during normal gestation. For the first time, the development of the circulation was demonstrated in the bitch and her fetuses intra vitam. The bloodstream was examined in small uteroplacental arteries, the umbilical artery, the fetal aorta and the common carotid artery. The duration of the study was from week 3 after insemination until birth. Relatively large vessels were detected by cross-sectional ultrasonography, and small vessels were detected by colour-flow imaging. In pulsed wave Doppler ultrasonography, the blood flow was measured and described using the parameters of systolic peak velocity, diastolic peak velocity, end-diastolic velocity, pulsatility index, resistance index, A:B ratio (systolic peak velocity:end-diastolic velocity) and S:D parameter (systolic peak velocity:diastolic peak velocity). The development of the measured parameters is typical and similar to that in humans. The systolic peak velocity of the canine maternal uteroplacental arteries shows important differences in comparison with humans. The pulsatility index, resistance index and A:B ratio decrease in nearly all vessels. Only the fetal common carotid artery has constant pulsatility and resistance indices during gestation. For the first time, the quality and quantity of the normal blood flow have been monitored during the whole of gestation. A normal circulation is fundamental for supplying the fetus adequately with oxygen and nutrients and thus for physiological development. These ultrasonographic results are the basis for further clinical studies.  相似文献   

14.
BACKGROUND: Previous studies have correlated quantitative coronary angiographic stenosis severity with positron emission tomography (PET) myocardial perfusion and proximal measurements of intracoronary flow velocities in normal and diseased coronary arteries. The aim of this study was to correlate regional myocardial blood flow (RMBF) derived from [15O]H2O PET with directly measured poststenotic intracoronary Doppler flow velocity data acquired under basal conditions and dipyridamole-induced hyperemia. METHODS AND RESULTS: Eleven consecutive patients 53 +/- 13 years old with ischemic chest pain and isolated proximal left coronary artery stenoses (left anterior descending, 9; left circumflex, 2; mean, 59 +/- 23% diameter stenosis) underwent [15O]H2O myocardial PET and intracoronary Doppler flow velocity studies within 1 week. PET RMBF (mL.g-1.min-1) and myocardial perfusion reserve (MPR) were calculated in poststenotic and normal reference vascular beds. Poststenotic Doppler average peak flow velocities (APV; cm/s) and coronary flow velocity reserve (CFR) were compared with corresponding PET data and quantitative angiographic lesional parameters. PET RMBF and Doppler APV were linearly correlated (r = .60; P < .001), as were poststenotic PET MPR and Doppler CFR (r = .76; P < .0002). Relative coronary flow velocity and MPR ratios between poststenotic and angiographically normal vascular beds were comparably reduced (0.83 +/- 0.25 versus 0.86 +/- 0.21, respectively; P = NS). CONCLUSIONS: Intracoronary Doppler flow velocities acquired distal to isolated left coronary artery stenoses correlated with [15O]H2O PET regional myocardial perfusion and are useful for assessment of the physiological significance of coronary stenoses in humans.  相似文献   

15.
The study was undertaken to determine if the internal carotid artery peak systolic velocities (ICA PSVs) measured by two colour Doppler imaging systems (Acuson 128 and Siemens Quantum) agree sufficiently for the two systems to be interchangeable in evaluating carotid artery disease. One operator obtained blinded measurements of ICA PSV in 63 prospective nonrandomized patients at risk of stroke. The operator examined 20 patients in the first cohort to assess the intraobserver variation, and 43 patients in the second cohort to assess the limits of agreement between the systems. In vitro comparisons of the systems were also undertaken, using both string and flow phantoms. Excluding one outlier, the intraobserver reproducibility coefficient for both machines was 0.48 m s-1. The limits of agreement (within which 95% of differences lie) between systems were -0.47 to 0.45 m s-1. This reduced to -0.39 to 0.33 m s-1 when the one outlier was excluded. This is within the intraobserver reproducibility range. In vitro data show little intersystem variation with phantom velocity. Intratransducer differences increase when the Doppler angle is increased using the string phantom; maximum differences: Acuson 0.30 m s-1 (42%) and Siemens 0.32 m s-1 (32%). These are within the in vivo reproducibility range. Intratransducer difference decreases when the Doppler angle is increased using the flow phantom, maximum differences: Acuson 0.05 m s-1 and Siemens 0.07 m s-1. The results show the systems agree sufficiently to be interchangeable in evaluating carotid artery disease; however, errors in maximum PSVs, caused by operator or system variation, may lead to errors in percent stenosis grading of the carotid arteries.  相似文献   

16.
OBJECTIVE: The purpose of this study was to evaluate both morphology and blood flow in peripheral arteries with occlusive lesions using MR angiography (MRA) and velocity-encoded cine MRI. MATERIALS AND METHODS: Two-dimensional time-of-flight MRA and velocity-encoded cine MRI were performed in nine patients with peripheral arterial occlusive disease. Findings on MR angiograms were verified by conventional angiography. RESULTS: All the stenotic lesions in the popliteal arteries were depicted by MRA. The degree of the stenoses in the artery was overestimated by MRA. Major collateral circulations were demonstrated. Velocity-encoded cine MRI provided flow velocity information on the arteries above and below the stenoses. The flow velocity waveform was monophasic above and below the stenosis. The peak systolic velocity in the artery below the stenosis was reduced compared with that above the stenosis (p < 0.05). CONCLUSION: The combination of MRA and velocity-encoded cine MRI has clinical potential for the evaluation of peripheral arterial occlusive disease.  相似文献   

17.
Directional flow in the frontal artery, a terminal branch of the ophthalmic artery, was assessed nonivasively by Doppler ultrasound druing brief digital compression of the ipsilateral common carotid artery in 62 patients. Directional frontal artery flow during carotid compression was compared with mean distal internal carotid back pressure measured at subsequent carotid endarterectomy. Mean carotid back pressure in 28 patients with normal frontal artery flow direction during carotid compression, 68 +/- 14 millimeters of mercury, was significantly higher than that observed in 24 patients in whom frontal artery flow was completely obliterated and ten in whom frontal artery flow was reversed. Distal internal carotid back pressure exceeded 48 millimeters of mercury in all patients with normal frontal artery flow direction during carotid compression. Conversely, carotid back pressure was below 41 millimeters of mercury in all but one patient in whom frontal artery flow was obliterated or bliterated or reversed during carotid compression. The results of this study indicate that Doppler ultrasound assessment of frontal artery flow direction during simultaneous carotid compression provides a rapid, sale noninvasive estimate of the adequacy of collateral hemispheric circulation.  相似文献   

18.
OBJECTIVE: To analyze the effects of carotid endarterectomy on the retrobulbar circulation of patients with severe occlusive carotid artery disease (OCAD) by means of color Doppler imaging (CDI). DESIGN: Prospective. PARTICIPANTS: A total of 17 consecutive patients with severe OCAD and neurologic symptoms (with a history of transitory ischemic attack or cerebral vascular accident) participated. INTERVENTION: All 17 patients underwent carotid endarterectomy. The CDI of both orbits was performed by one masked investigator before surgery and at 1 week and 1 month after surgery. MAIN OUTCOME MEASURES: Peak systolic velocity, end diastolic velocity, and resistive index of the ophthalmic, central retinal, and temporal short posterior ciliary arteries were measured. The authors compared the hemodynamic parameters at all intervals. RESULTS: Peak systolic and end diastolic velocities in the ophthalmic, central retinal, and temporal short posterior ciliary arteries increased significantly 1 week and 1 month after carotid endarterectomy (P < 0.05). After surgery, the resistive indices in the central retinal and temporal short posterior ciliary arteries decreased significantly at both intervals (P < 0.05). The six patients who had reversed ophthalmic artery flow before surgery showed forward ophthalmic artery flow after carotid endarterectomy. The contralateral orbits showed no significant hemodynamic change after endarterectomy (P < 0.05). CONCLUSIONS: Hemodynamic changes in patients with severe OCAD undergoing carotid endarterectomy suggest improvement in the ipsilateral retrobulbar blood flow.  相似文献   

19.
PURPOSE: To review patients who have presented with acute strokes from a middle cerebral artery occlusion in whom in addition to the middle cerebral artery thromboembolus, an internal carotid artery occlusion has been present, and in whom angioplasty of these totally occluded internal carotid arteries has bee n successful. METHODS: We reviewed retrospectively our experience in treating a cute stroke patients with intracranial, intraarterial urokinase. Six of 27 patients had internal carotid artery occlusions in addition to middle cerebral artery occlusions. Two patients presented with spontaneous carotid dissections for wh ich no further intervention from the ipsilateral internal carotid artery was attempted. In the remaining four internal carotid artery occlusions secondary to atherosclerotic disease, standard guide wires and catheters were negotiated across the level of the internal carotid artery occlusion, which expedited intracranial catheterization for thrombolysis. Subsequently, angioplasty of the internal carotid artery was performed. RESULTS: All four occluded internal carotid arteries could be traversed. No new neurologic deficits occurred. No vascular injuries occurred. No deaths occurred. Four- to 6-month follow-up showed all four internal carotid arteries remained patent. CONCLUSION: In acute occlusions of the internal carotid artery from atherosclerosis, the occluded vessel can sometimes be recanalized with low morbidity. In addition, endovascular access to the intracranial circulation can be expedited by using the recanalized internal carotid artery.  相似文献   

20.
The objectives of this study were to detect differences in the Doppler power backscattered by blood in vivo, and to identify factors affecting the backscattered power. The main hypothesis was that variations in the erythrocyte aggregation level between veins and arteries of normolipidemic and hyperlipidemic individuals can be detected with power Doppler ultrasound. Doppler measurements were performed at 5 MHz, with an Acuson 128 XP/10 system, over the carotid artery and jugular vein, external iliac artery and vein, common femoral artery and vein and popliteal artery and vein. Doppler signals were recorded at the center of each vessel to optimize the detection of erythrocyte aggregation, and processed off-line to obtain the backscattered power. The power of each recording was compensated for Doppler gain differences, tissue attenuation with depth and transmitted power variations occurring with pulse-repetition interval modifications. Results showed statistically stronger backscattered power in veins compared to arteries for the iliac, femoral and popliteal sites. In comparison with healthy subjects, stronger powers were observed in hyperlipidemic patients for the femoral and popliteal sites. Power differences were also found between peripheral measurements. On the other hand, no difference was observed between the power measured in the carotid artery and jugular vein for both groups of individuals. Multiple linear regression analyses were performed to identify factors affecting the backscattered power. Results showed a correlation (r) of 71.2% between the Doppler power in the femoral vein and the linear combination of two parameters: an erythrocyte aggregation index S10 measured with a laser scattering method, and the diameter of the vessel measured on B-mode images. Statistically significant linear correlation levels were also found between S10 and the Doppler power in various vessels. In conclusion, this study showed that power Doppler differences exist in vivo in large vessels between veins and arteries of normolipidemic and hyperlipidemic individuals. The Doppler power variations were also shown to be related to erythrocyte aggregation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号