首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 250 毫秒
1.
Delivery of proteins and peptides to electrospray ionization mass spectrometers (ESI-MS) has been demonstrated using glass and quartz microfabricated devices. This paper reports the construction and use of poly(dimethylsiloxane) (PDMS) microfabricated soft polymer devices with mass spectrometry for protein analysis. The PDMS devices were fabricated using replica molding against a patterned photoresist generated by photolithographic techniques. The PDMS devices were connected to the mass spectrometer via a derivatized transfer capillary and samples were transferred by electroosmotic pumping. The formulation of PDMS was optimized for compatibility with ESI, and the devices were tested for performance. The practical application of PDMS devices was demonstrated by the identification of rat serum albumin separated by 2-D gel electrophoresis. Extended contact of the sample with the surface of the PDMS device did not significantly affect the sample analysis, and the limit of detection for samples run on a PDMS device was comparable to the limit of detection achieved on glass devices. This study suggests that PDMS devices fabricated using replica molding are compatible with ESI-MS. This will potentially lead to the construction of inexpensive microfabricated devices with complex designs and advanced functionalities.  相似文献   

2.
For this work, two different plastic microfluidic devices are designed and fabricated for applications in high-throughput residue analysis of food contaminants and drug screening of small-molecule libraries. Microfluidic networks on copolyester and poly(dimethylsiloxane) substrates are fabricated by silicon template imprinting and capillary molding techniques. The first device is developed to perform affinity capture, concentration, and direct identification of targeted compounds using electrospray ionization mass spectrometry. Poly(vinylidene fluoride) membranes sandwiched between the imprinted copolyester microchannels in an integrated platform provide continuous affinity dialysis and concentration of a reaction mixture containing aflatoxin B1 antibody and aflatoxins. The second microfluidic device is composed of microchannels on the poly(dimethylsiloxane) substrates. The device is designed to perform miniaturized ultrafiltration of affinity complexes of phenobarbital antibody and barbiturates, including the sequential loading, washing, and dissociation steps. These microfabricated devices not only significantly reduce dead volume and sample consumption but also increase the detection sensitivity by at least 1-2 orders of magnitude over those reported previously. Improvements in detection sensitivity are attributed to analyte preconcentration during the affinity purification step, limited analyte dilution in the microdialysis junction, minimal sample loss, and the amenability of ESI-MS to nanoscale sample flow rates.  相似文献   

3.
A new design for high-throughput microfabricated capillary electrophoresis/electrospray mass spectrometry (CE/ ESI-MS) with automated sampling from a microwell plate is presented. The approach combines a sample-loading port, a separation channel, and a liquid junction, the latter for coupling the device to the MS with a miniaturized subatmospheric electrospray interface. The microdevice was attached to a polycarbonate manifold with external electrode reservoirs equipped for electrokinetic and pressure-fluid control. A computer-activated electropneumatic distributor was used for both sample loading from the microwell plate and washing of channels after each run. Removal of the electrodes and sample reservoirs from the microdevice structure significantly simplified the chip design and eliminated the need both for drilling access holes and for sample/buffer reservoirs. The external manifold also allowed the use of relatively large reservoirs that are necessary for extended time operation of the system. Initial results using this microfabricated system for the automated CE/ESI-MS analysis of peptides and protein digests are presented.  相似文献   

4.
Rapid protein digestion and analysis using a hybrid microchip nanoelectrospray device and time-of-flight mass spectrometry detection are reported. The device consists of a planar glass chip with microfabricated channels coupled to a disposable nanospray emitter. Reactions between substrate and enzyme (trypsin), mixed off-chip and then immediately loaded into a sample reservoir on the device, are monitored in real time following the onset of electrospray. Protein cleavage products are determined at the optimum pH for generating tryptic fragments, directly from the digestion buffer using "wrong-way-round" electrospray, i.e., monitoring (MH)+ ions from basic solutions. Intense tryptic peptide ions are observed within a few minutes following sample loading on the microchip. Proteins were identified from low femtomole or even attomole quantities of analyte/spectrum using peptide mass fingerprinting, loading 0.1-2 pmol/microL of sample on the chip. The sequence coverage for analyzed proteins ranged from 70 to 95%. The rapid analysis of human hemoglobin is demonstrated using the technique.  相似文献   

5.
The coupling of microfabricated devices to nanoelectrospray mass spectrometers using both a triple quadrupole and a quadrupole time-of-flight mass spectrometer (QqTOF MS) is presented for the analysis of trace-level membrane proteins. Short disposable nanoelectrospray emitters were directly coupled to the chip device via a low dead volume connection. The analytical performance of this integrated device in terms of sensitivity and reproducibility was evaluated for standard peptide mixtures. A concentration detection limit ranging from 3.2 to 43.5 nM for different peptides was achieved in selected ion monitoring, thus representing a 10-fold improvement in sensitivity compared to that of microelectrospray using the same chip/mass spectrometer. Replicate injections indicated that reproducibility of migration time was typically less than 3.1% RSD whereas RSD values of 6-13% were observed on peak areas. Although complete resolution of individual components is not typically achieved for complex digests, the present chip capillary electrophoresis (chip-CE) device enabled proper sample cleanup and partial separation of multicomponent samples prior to mass spectral identification. Analyses of protein digests were typically achieved in less than 1.5 min with peak widths of 1.8-2.5 s (half-height definition) as indicated from individual reconstructed ion electropherograms. The application of this chip-CE/QqTOF MS system is further demonstrated for the identification of membrane proteins which form a subset of the Haemophilus influenzae proteome. Bands first separated by 1D-gel electrophoresis were excised and digested, and extracted tryptic peptides were loaded on the chip without any further sample cleanup or on-line adsorption preconcentration. Accurate molecular mass determination (< 5 ppm) in peptide-mapping experiments was obtained by introducing an internal standard via a postseparation channel. The analytical potential of this integrated device for the identification of trace-level proteins from different strains of H. influenzae is demonstrated using both peptide mass-fingerprint database searching and on-line tandem mass spectrometry.  相似文献   

6.
On-line coupling of in vivo microdialysis with tandem mass spectrometry.   总被引:2,自引:0,他引:2  
The capability of interfacing in vivo microdialysis with mass spectrometry has been demonstrated. The goal of this research was to demonstrate the feasibility of real-time analysis in biological systems using microdialysis in combination with tandem mass spectrometry (MS/MS). Microdialysis sampling was accomplished by surgically implanting a small microdialysis probe into a tissue or area of interest. Molecules diffuse through the membrane of the microdialysis probe due to concentration differences. These molecules are collected in a sample loop and analyzed by tandem mass spectrometry. Sequential injections can be made in as little as 2 min. This capability is advantageous in the study of molecules with very rapid elimination rates. Tris(2-chloroethyl)phosphate (TRCP) was used as a model compound in the development of this analytical technique. As an example of an application of the microdialysis/MS/MS technique, plasma concentration vs time curves were obtained and compared with the plasma concentration profiles obtained using conventional studies. For the microdialysis/MS/MS studies, the average slope from three animals was -0.086 min-1. In comparison, the average slope from four animals from the conventional studies was -0.035 min-1.  相似文献   

7.
Microfluidic electrophoresis devices were coupled on-line to microdialysis for in vivo monitoring of primary amine neurotransmitters in rat brain. The devices contained a sample introduction channel for dialysate, a precolumn reactor for derivatization with o-phthaldialdehyde, a flow-gated injector, and a separation channel. Detection was performed using confocal laser-induced fluorescence. In vitro testing revealed that the initial device design had detection limits for amino acids of approximately 200 nM, relative standard deviation of peak heights of 2%, and separations within 95 s with up to 30,200 theoretical plates when applying an electric field of 370 V/cm. A second device design that allowed electric fields of 1320 V/cm to be applied while preserving the reaction time allowed separations within 20 s with up to 156,000 theoretical plates. Flow splitting into the electrokinetic network from hydrodynamic flow in the sample introduction channel was made negligible for sampling flow rates from 0.3 to 1.2 microL/min by placing a 360-microm-diameter fluidic access hole that had flow resistance (0.15-7.2) x 10(8)-fold lower than that of the electrokinetic network at the junction of the sample introduction channel and the electrokinetic network. Using serial injections, the device allowed the dialysate stream to be analyzed at 130-s intervals. In vivo monitoring was demonstrated by using the microdialysis/microfluidic device to record glutamate concentrations in the striatum of an anesthetized rat during infusion of the glutamate uptake inhibitor l-trans-pyrrolidine-2,4-dicarboxylic acid. These results prove the feasibility of using a microfabricated fluidic system coupled to sampling probes for chemical monitoring of complex media such as mammalian brain.  相似文献   

8.
This report describes the development of a compact and versatile, micromachined chip device enabling the efficient coupling of capillary electrophoresis to electrospray mass spectrometry (CE-ESMS). On-chip separation provides a convenient means of achieving rapid sample cleanup and resolution of multicomponent samples (typically 2-5 min) prior to mass spectral analysis. A low dead volume connection facilitating the coupling of microfabricated devices to CE-ESMS was evaluated using two different interfaces. The first configuration used disposable nanoelectrospray emitters directly coupled to the chip device via this low dead volume junction, thereby providing rapid separation of complex protein digests. The performance of this interface was compared with that of more traditional configurations using a sheath flow CE-ESMS arrangement where a fused-silica capillary of varying length enabled further temporal resolution of the multicomponent samples. The sensitivity and analytical characteristics of these interfaces were investigated in both negative and positive ion modes using standard peptide mixtures. The separation performance for synthetic peptides using a chip coated with amine reagent ranged from 26,000 to 58,000 theoretical plates for a sheath flow CE-ESMS interface comprising a 15-cm CE column. Replicate injections of a dilution series of peptide standards provided detection limits of 45-400 nM without the use of on-line preconcentration devices. The reproducibility of migration time ranged from 0.9 to 1.5% RSD whereas RSDs of 5-10% were observed on peak areas. The application of these devices for the analysis of protein digests was further evaluated using on-line tandem mass spectrometry.  相似文献   

9.
Fu Z  Shao G  Wang J  Lu D  Wang W  Lin Y 《Analytical chemistry》2011,83(7):2685-2690
A renewable flow cell integrating a microstructured pillar-array filter and a pneumatic microvalve was microfabricated to trap and release beads. A bead-based immunoassay using this device was also developed. This microfabricated device consists of a microfluidic channel connecting to a beads chamber in which the pillar-array filter is built. Underneath the filter, there is a pneumatic microvalve built across the chamber. Such a device can trap and release beads in the chamber by "closing" or "opening" the microvalve. On the basis of the pneumatic microvalve, the device can trap beads in the chamber before performing an assay and release the used beads after the assay. Therefore, this microfabricated device is suitable for "renewable surface analysis". A model analyte, 3,5,6-trichloropyridinol (TCP), was chosen to demonstrate the analytical performance of the device. The entire fluidic assay process, including beads trapping, immuno binding, beads washing, beads releasing, and chemiluminesence signal collection, could be completed in 10 min. The immunoassay of TCP using this microfabricated device showed a linear range of 0.20-70 ng/mL with a limit of detection of 0.080 ng/mL. The device was successfully used to detect TCP spiked in human plasma at the concentration range of 1.0-50 ng/mL, with an analytical recovery of 81-110%. The results demonstrated that this device can provide a rapid, sensitive, reusable, low-cost, and automatic tool for detecting various biomarkers in biological fluids.  相似文献   

10.
The adverse effects of nonvolatile salts on the electrospray (ESI) mass spectra of proteins and other biological analytes are a major obstacle for a wide range of applications. Numerous sample cleanup approaches have been devised to facilitate ESI-MS analyses. Recently developed microdialysis techniques can shorten desalting times down to several minutes, the bottleneck being diffusion of the contaminant through a semipermeable membrane. This work introduces an approach that allows the on-line desalting of macromolecule solutions within tens of milliseconds. The device does not employ a membrane; instead, it uses a two-layered laminar flow geometry that exploits the differential diffusion of macromolecular analytes and low molecular weight contaminants. To maximize desalting efficiency, diffusive exchange between the flow layers is permitted only for such a time as to allow full exchange of salt, while incurring minimal macromolecule exchange. Computer simulations and optical studies show that the device can reduce the salt concentration by roughly 1 order of magnitude, while retaining approximately 70% of the original protein concentration. Application of this approach to the on-line purification of salt-contaminated protein solutions in ESI-MS results in dramatic improvements of both the signal-to-noise ratio and the absolute signal intensity. However, efficient desalting requires the diffusion coefficients of salt and analyte to differ by roughly 1 order of magnitude or more. This technique has potential to facilitate high-throughput analyses of biological macromolecules directly from complex matrixes. In addition, it may become a valuable tool for process monitoring and for on-line kinetic studies on biological systems.  相似文献   

11.
The basic principles of multichannel devices with an array of electrospray tips for high-throughput infusion electrospray ionization mass spectrometry (ESI-MS) have been developed. The prototype plastic devices were fabricated by casting from a solvent-resistant resin. The sample wells on the device were arranged in the format of the standard 96-microtiter well plate, with each sample well connected to an independent electrospray exit port via a microchannel with imbedded electrode. A second plastic plate with distribution microchannels was employed as a cover plate and pressure distributor. Nitrogen gas was used to pressurize individual wells for transport of sample into the electrospray exit port. The design of independent microchannels and electrospray exit ports allowed very high throughput and duty cycle, as well as elimination of any potential sample carryover. The device was placed on a computer-controlled translation stage for precise positioning of the electrospray exit ports in front of the mass spectrometer sampling orifice. High-throughput ESI-MS was demonstrated by analyzing 96 peptide samples in 480 s, corresponding to a potential throughput of 720 samples/h. As a model application, the device was used for the MS determination of inhibition constants of several inhibitors of HIV-1 protease.  相似文献   

12.
The accurate measurement of free analyte concentrations within complex sample matrixes by pre-equilibrium solid-phase microextraction (SPME) has proven challenging due to variations in mass uptake kinetics. For the first time, the effects of the sample binding matrix and tortuosity on the kinetics of analyte extraction (from the sample to the SPME fiber) are demonstrated to be quantitatively symmetrical with those of the desorption of preloaded deuterated standards (from the fiber to the sample matrix). Consequently, kinetic calibration methods can be employed to correct for variation in SPME sampling kinetics, facilitating the application of pre-equilibrium SPME within complex sample systems. This approach was applied ex vivo to measure pharmaceuticals in fish muscle tissues, with results consistent with those obtained from equilibrium SPME and microdialysis. The developed method has the inherent advantages of being more accurate, precise, and reproducible, thus providing the framework for applications where rapid measurement of free analyte concentrations (within complicated sample matrixes such as biological tissues, sediment, and surface water) are required.  相似文献   

13.
Liquid chromatography-mass spectrometry (LC-MS) is a common method for profiling biological samples in metabolomics. However, LC-MS data of metabolomic studies are often affected by high noise levels, retention time shifts, and high variability in signal intensities. With a new chip-based nanoelectrospray source it becomes possible to directly infuse complex biological samples such as plasma without any chromatographic separation beforehand. In combination with highly diluted samples and long data acquisition times, the parallel analysis of hundreds of compounds is now possible. In a proof-of-concept study, 10 human plasma samples from females and males were analyzed with the intention to separate the two groups by their different metabolomes. The reproducibility was so high that statistical analysis of the data could be performed without prior normalization. Two groups of female and male samples were separated by a supervised machine learning algorithm, principal component analysis, and hierarchical clustering. Peaks contributing to the group separation were characterized by accurate mass measurement and MS-MS fragmentation and by spiking experiments. The feasibility of direct sample infusion using the new chip-based nanoelectrospray device opens a new dimension for the rapid parallel analysis of complex biological mixtures.  相似文献   

14.
A capillary electrophoresis/electrospray ionization mass spectrometry (CE/ESI-MS) interface, based on an electric circuit across a microdialysis membrane surrounding a short capillary segment closely connected to the separation capillary terminus, is demonstrated to be sensitive, efficient, and rugged. A microspray type ionization emitter produces a stable electrospray at the low flow rates provided by CE and thus avoids both the need for a makeup liquid flow provided by liquid junction or sheath flow interfaces and the subsequent dilution and reduction in sensitivity. Reproducibility studies and comparisons with CE/UV and the CE/sheath flow interface with ESI-MS are presented. Additionally, postrun acidification via the microdialysis junction interface is demonstrated and shown to be capable of denaturing the holomyoglobin protein noncovalent complex while maintaining separation efficiency.  相似文献   

15.
A fully automated high-throughput liquid-liquid extraction (LLE) methodology has been developed for preparation of biological samples using a 96-well LLE plate and a 96-channel robotic liquid handling workstation. The 96-well LLE plate is made of a 96-well filter plate filled with inert diatomaceous earth particles, allowing continuous and efficient extraction of analytes between the aqueous biological sample and the organic extraction solvent. Two carboxylic acid-based protease inhibitor compounds with high and low levels of plasma protein binding were chosen for the development and application of the automated methodology. The LLE extracts of the plasma samples of the two compounds were analyzed by high-performance liquid chromatography with electrospray (ESI) tandem mass spectrometry (LC-MS/MS). The LC-MS/MS method was developed using a rapid gradient LC separation, followed by sample introduction through an ionspray interface in the negative ion mode and tandem mass spectrometric detection with selected reaction monitoring. In the optimized LLE method, a formate buffer solution was first loaded into a 96-well filter plate packed with inert diatomaceous earth material. Then crude plasma samples and a water-immiscible organic solvent, methyl ethyl ketone, were sequentially added to the LLE plate so that LLE would occur in the interface between the two liquid phases on the surface of individual particles in each well. The organic eluate containing extracted analytes was evaporated and reconstituted for LC-MS/MS analysis. This fully automated LLE methodology avoids several disjointed steps involved in a manual or semiautomated LLE method, leading to significantly reduced sample preparation time, increased sample throughput, and clean sample extracts for improved ESI-MS/MS detection. The automated LLE methodology is universal and can be employed for sample preparation of other biological fluids. The complete bioanalytical method, based on the automated LLE and fast gradient LC-MS/MS, was validated and successfully applied to the quantitative analysis of protease inhibitors in rat plasma.  相似文献   

16.
Developing sensors for in vivo chemical monitoring is a daunting challenge. An alternative approach is to couple sampling methods with online analytical techniques; however, such approaches are generally hampered by lower temporal resolution and slow analysis. In this work, microdialysis sampling was coupled with segmented flow electrospray ionization mass spectrometry (ESI-MS) to perform in vivo chemical monitoring. The use of segmented flow to prevent Taylor dispersion of collected zones and rapid analysis with direct ESI-MS allowed 5 s temporal resolution to be achieved. The MS "sensor" was applied to monitor acetylcholine in the brain of live rats. The detection limit of 5 nM was sufficient to monitor basal acetylcholine as well as dynamic changes elicited by microinjection of neostigmine, an inhibitor of acetycholinesterase, that evoked rapid increases in acetycholine and tetrodotoxin, a blocker of Na(+) channels, that lowered the acetylcholine concentration. The versatility of the sensor was demonstrated by simultaneously monitoring metabolites and infused drugs.  相似文献   

17.
A complete field-deployable microfabricated gas chromatograph (μGC) is described, and its adaptation to the analysis of low- and subparts-per-billion (ppb) concentrations of trichloroethylene (TCE) vapors in complex mixtures is demonstrated through laboratory testing. The specific application being addressed concerns the problem of indoor air contamination by TCE vapor intrusion. The μGC prototype employs a microfabricated focuser, dual microfabricated separation columns, and a microsensor array. These are interfaced to a nonmicrofabricated front-end pretrap and high-volume sampler module to reduce analysis time and limits of detection (LOD). Selective preconcentration and focusing are coupled with rapid chromatographic separation and multisensor detection for the determination of TCE in the presence of up to 45 interferences. Autonomous operation is possible via a laptop computer. Preconcentration factors as high as 500?000 are achieved. Sensitivities are constant over the range of captured TCE masses tested (i.e., 9-390 ng), and TCE is measured in a test atmosphere at 120 parts-per-trillion (ppt), with a projected LOD of 40 ppt (4.2 ng captured, 20 L sample) and a maximum sampling + analytical cycle time of 36 min. Short- and medium-term (1 month) variations in retention time, absolute responses, and response patterns are within acceptable limits.  相似文献   

18.
A novel microfabricated nozzle has been developed for the electrospray of liquids from microfluidic devices for analysis by mass spectrometry. The electrospray device was fabricated from a monolithic silicon substrate using deep reactive ion etching and other standard semiconductor techniques to etch nozzles from the planar surface of a silicon wafer. A channel extends through the wafer from the tip of the nozzle to a reservoir etched into the opposite planar surface of the wafer. Nozzle diameters as small as 15 microm have been fabricated using this method. The microfabricated electrospray device provides a reproducible, controllable, and robust means of producing nano-electrospray of a liquid sample. The electrospray device was interfaced to an atmospheric pressure ionization time-of-flight mass spectrometer using continuous infusion of test compounds at low nanoliter-per-minute flow rates. Nozzle-to-nozzle signal intensity reproducibility using 10 nozzles was demonstrated to be 12% with single-nozzle signal stability routinely less than 4% relative standard deviation (RSD). Solvent compositions have been electrosprayed ranging from 100% organic to 100% aqueous. The signal-to-noise ratio from the infusion of a 10 nM cytochrome c solution in 100% water at 100 nL/min was 450:1. Microchip electrospray nozzles were compared with pulled capillaries for overall sensitivity and signal stability for small and large molecules. The microchip electrospray nozzles showed a 1.5-3-times increase in sensitivity compared with that from a pulled capillary, and signal stability with the microchip was 2-4% RSD compared with 4-10% with a pulled capillary. Electrospray device lifetimes achieved thus far have exceeded 8 h of continuous operation and should be sufficient for typical microfluidic applications. The total volume of the electrospray device is less than 25 pL, making it suitable for combination with microfluidic separation devices.  相似文献   

19.
We have developed a new mass spectrometry (MS) based approach for continuous, spatially resolved in vitro biochemical detection and demonstrated its utility in a 3-D cell culture system. Extracellular liquid is passively extracted at a low flow rate (~10 nL/s) through a small bore silica capillary (ID 50 μm); inline microdialysis (MD) removes ions that would interfere with mass spectrometric analysis, and the sample is ionized by nanoelectrospray ionization (nano-ESI) and mass analyzed in a time-of-flight mass spectrometer. The system successfully detects low-volume, low-concentration releases of a small protein (8 μL of 5 μM cytochrome-c, molecular mass ~12 kDa) and exhibits ~1 min temporal resolution. The system also displays sensitivity to probe proximity to the sample release point. Due to the sensitivity of ESI-MS and its ability to simultaneously detect and identify multiple unanticipated biochemicals, this approach shows considerable potential as a biomarker discovery tool.  相似文献   

20.
A microfabricated microfluidic device coupled with a nanospray tip for electrospray ionization of dilute solutions is described. The device has been interfaced with a time-of-flight mass spectrometer and evaluated for sensitive, high-speed detection of peptides and proteins. The electrospray voltage was applied through the microchip to the nanospray capillary that was attached at the end of a microfabricated channel. Fluid delivery rates were 20-30 nL min(-)(1) through the hybridized structure without any pressure assistance. On-line microchip electrophoresis has been demonstrated and the effect of the capillary-chip junction on band broadening examined. Full mass spectra are acquired within 10-20 ms at 50-100 spectra s(-)(1) storage rates. Detection of subattomole levels of sample from a 100 nM solution is demonstrated for infusion experiments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号