首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 13 毫秒
1.
A method combining immunomagnetic separation (IMS) and real-time (5'-nuclease) PCR was developed to detect Escherichia coli O157:H7. Monoclonal antibody specific for the E. coli O157 antigen was added to protein A-coated magnetic particles to create antibody-coated beads. The beads specifically captured E. coli O157:H7 from bacterial suspensions. The cells were eluted from the beads and lysed by heating; the eluate was then assayed by real-time PCR, using primers and probe specifically targeting the eaeA gene of E. coli O157:H7. Approximately 50% of the cells in suspension were captured by the beads and detected by real-time PCR. No cross-reactivity was detected when other strains of E. coli were tested. This method was applied to detect E. coli O157:H7 from ground beef. Both cell capture efficiency and real-time PCR efficiency were reduced by meat-associated inhibitors. However, we were still able to detect up to 8% of E. coli O157:H7 from inoculated ground beef samples. The detection sensitivity varied among ground beef samples. The minimum detection limit was <5x10(2) cells ml(-1) for suspensions of E. coli O157:H7 in buffer and 1.3x10(4) cells g(-1) for E. coli O157:H7 in ground beef. The combination of IMS and real-time PCR results in rapid, specific and quantitative detection of E. coli O157:H7 without the need for an enrichment culture step.  相似文献   

2.
The DNA band patterns generated by polymerase chain reaction (PCR) using the du2 primer and template DNAs from various strains of Escherichia coli and non-E. coli bacteria were compared. Among three to five prominent bands produced, the three bands at about 1.8, 2.7, and 5.0 kb were detected in all of the E. coli O157 strains tested. Some nonpathogenic E. coli and all pathogenic E. coli except E. coli O157 showed bands at 1.8 and 5.0 kb. It seems that the band at 2.7 kb is specific to E. coli O157. Sequence analysis of the 2.7-kb PCR product revealed the presence of a DNA sequence specific to E. coli O157:H- and E. coli O157:H7. Since the DNA sequence from base 15 to base 1,008 of the PCR product seems to be specific to E. coli O157, a PCR assay was carried out with various bacterial genomic DNAs and O157-FHC1 and O157-FHC2 primers that amplified the region between base 23 and base 994 of the 2.7-kb PCR product. A single band at 970 bp was clearly detected in all of the strains of E. coli O157:H- and E. coli O157:H7 tested. However, no band was amplified from template DNAs from other bacteria, including both nonpathogenic and pathogenic E. coli except E. coli O157. All raw meats inoculated with E. coli O157:H7 at 3 x 10(0) to 3.5 x 10(2) CFU/25 g were positive both for our PCR assay after cultivation in mEC-N broth at 42 degrees C for 18 h and for the conventional cultural method.  相似文献   

3.
We describe the development and application of an electromagnetic flow cell and fluidics system for automated immunomagnetic separation (IMS) of Escherichia coli O157:H7 directly from poultry carcass rinse. We further describe the biochemical coupling of automated sample preparation with nucleic acid microarrays. Both the cell concentration system and microarray detection method did not require cell growth or enrichment from the poultry carcass rinse prior to IMS. Highly porous Ni foam was used to enhance the magnetic field gradient within the flow path, providing a mechanism for immobilizing immunomagnetic particles throughout the fluid rather than the tubing wall. A maximum of 32% recovery efficiency of non-pathogenic E. coli was achieved within the automated system with 6 s cell contact times using commercially available antibodies targeted against the O and K antigens. A 15-min protocol (from sample injection though elution) provided a cell recovery efficiency that was statistically similar to > I h batch captures. O157:H7 cells were reproducibly isolated directly from poultry carcass rinse with 39% recovery efficiency at 10(3) CFU ml(-1) inoculum. Direct plating of washed beads showed positive recovery of O157:H7 directly from poultry carcass rinse at an inoculum of 10 CFU ml(-1). Recovered beads were used for direct polymerase chain reaction (PCR) amplification and microarray detection, with a process-level detection limit (automated cell concentration though microarray detection) of < 10(3)CFU ml(-1) in poultry carcass rinse.  相似文献   

4.
The direct detection and estimation of concentration of Escherichia coli O157:H7 down to 1 CFU/g of cheese was achieved by conventional plating techniques. Cheese was manufactured with unpasteurized milk inoculated with E. coli O157: H7 at 34 +/- 3 CFU/ml. The numbers of E. coli O157:H7 were monitored during cheese ripening by plating on sorbitol MacConkey agar supplemented with cefixime and potassium tellurite (CT-SMAC) and on CT-O157:H7 ID medium. Using the pour plate method, E. coli O157:H7 colonies could easily be distinguished from non-O157:H7 colonies on CT-O157:H7 ID medium but not on CT-SMAC. Higher numbers of E. coli O157:H7 were detectable with O157:H7 ID medium. Latex agglutination and PCR were used to confirm the identification of typical E. coli O157:H7 colonies, and nontypical colonies as not being E. coli O157:H7. As few as 1 CFU/g of cheese could be detected. E. coli O157:H7 also was detected in deliberately contaminated milk at concentrations as low as 4 CFU/10 ml.  相似文献   

5.
建立了一种快速检测原料乳中大肠杆菌O157:H7的PCR技术.该方法利用过滤富集菌体后的PCR技术来检测原料乳中大肠杆菌O157:H7,先对人工污染大肠杆菌O157:H7的原料乳进行离心脱脂,然后添加EDTA-2Na获得澄清乳液,最后通过0.45 μm微膜过滤收集菌体,整个过程只需6 h左右即可完成.检测灵敏度高达10-mL-1.这种方法在传统检测方法的基础上做了有效改进,使得原料乳中的大肠杆菌O157:H7的检测能够快速、准确、灵敏的进行.  相似文献   

6.
Salmonella infection is the second most prevalent cause of foodborne illness in most developing countries. Meat, poultry, and dairy products are frequently implicated in outbreaks. The objective of this study was to apply a novel immunomagnetic separation (IMS)-bacteriophage assay to the detection of Salmonella enteritidis in artificially inoculated skimmed milk powder, chicken rinses, and ground beef. In all food types tested, the IMS-bacteriophage assay was able to detect an average of 3 CFU of S. enteritidis in 25 g or ml of food sample. Total assay time including pre-enrichment is about 20 h. The results indicate that the IMS-bacteriophage assay is a rapid and sensitive means of detecting S. enteritidis in these foods. The assay was successfully adapted to the detection of Escherichia coli O157:H7 and was able to detect E. coli in ground beef at the lowest inoculation level tested, 2 CFU/g. The assay was also adapted to the simultaneous detection of S. enteritidis and E. coli. The results indicate that the IMS-bacteriophage assay shows promise for the simultaneous detection of these pathogens, but further development work would be necessary to improve sensitivity and produce reliable results at low inoculation levels.  相似文献   

7.
Series of animal feces and meat samples artificially contaminated with strains of Escherichia coli O157 isolated from different sources were tested by both an immunomagnetic separation (IMS)-based method and a PCR method using primers specific for a portion of the rfbE gene of E. coli O157. IMS is laborious and time consuming but ends up with the isolation of the pathogen. PCR is fast and less laborious, but it can only be used for screening purposes, so a further culture step is required to isolate the organism. For both fecal and meat samples, the IMS method was found to be more sensitive than the PCR. Furthermore, the detection efficiency of the PCR was influenced by the origin of the fecal sample and the type of meat. For sheep feces, the efficiency of the PCR appeared to be systematically lower than for cattle feces. And the efficiency of the PCR in detecting E. coli O157 in spiked samples of raw minced beef and dry-fermented sausages was systematically lower than in samples of filet americain. Based on this study, it can be concluded that both for animal feces and meat, IMS can be used more successfully to detect E. coli O157 than PCR, because IMS showed to be more sensitive and the outcome was not influenced by the type of animal feces or meat.  相似文献   

8.
To establish the best detection method for Escherichia coli O157:H7 on produce, the sensitivity, specificity, and recovery values of 3 selective media [sorbitol MacConkey agar containing cefixime and tellurite (CTSMAC), sorbitol MacConkey agar containing cefixime, tellurite, and 5-bromo-4-chloro-3-indoxyl-β-glucuronide (CTB-SMAC), and CHROMagar O157 were compared. Sample preparation methods (pummeling, sonication, and hand-shaking) were compared to determine the optimum procedure for qualitative analysis from cherry tomato. The selectivity and recovery rates of stressed cell of the 3 tested media were in the order of CHROMagar O157>CTBSMAC>CT-SMAC. The recovery rates of hand-shaken tomatoes (10/10) were higher than rates of sonicated (8/10) and pummeled tomatoes (6/10) for inoculated cherry tomatoes in modified E. coli (mEC) broth enriched with novobicin. CHROMagar O157 was the optimum agar medium for detection of E. coli O157:H7. Cherry tomatoes should be treated with hand-shaking to enhance recovery for qualitative analysis.  相似文献   

9.
A quartz crystal microbalance (QCM) immunosensor was developed and evaluated for detection of Escherichia coli O157:H7. The immunosensor was fabricated by self-assembling of protein A and affinity-purified anti-E. coli O157:H7 antibodies on the gold electrode of an AT-cut piezoelectric quartz crystal. To enhance the sensitivity of the QCM immunosensor, nanoparticle-antibody conjugates, which were prepared using streptavidin-conjugated nanoparticles (145 nm diameter) and biotinylated anti-E. coli antibodies, were used for signal amplification. After the binding of E. coli O157:H7 cells with the antibodies immobilized on the electrode, nanoparticle-antibody conjugates were introduced as mass amplifiers. Compared to the direct detection of E. coli O157:H7, the binding of the nanoparticle conjugates further resulted in a decrease in resonant frequency and an increase in resonant resistance, and the detection sensitivity was improved by five orders of magnitude by lowering the detection limit from 107 to 102 CFU/mL. The sensor specificity and nonspecific adsorption of nanoparticle-antibody conjugates were also investigated.  相似文献   

10.
The immunomagnetic separation with magnetic nanoparticle-antibody conjugates (MNCs) was investigated and evaluated for the detection of Escherichia coli O157:H7 in ground beef samples. MNCs were prepared by immobilizing biotin-labeled polyclonal goat anti-E. coli antibodies onto streptavidin-coated magnetic nanoparticles. For bacterial separation, MNCs were mixed with inoculated ground beef samples, then nanoparticle-antibody-E. coli O157:H7 complexes were separated from food matrix with a magnet, washed, and surface plated for microbial enumeration. The capture efficiency was determined by plating cells bound to nanoparticles and unbound cells in the supernatant onto sorbitol MacConkey agar. Key parameters, including the amount of nanoparticles and immunoreaction time, were optimized with different concentrations of E. coli O157:H7 in phosphate-buffered saline. MNCs presented a minimum capture efficiency of 94% for E. coli O157:H7 ranging from 1.6 x 10(1) to 7.2 x 10(7) CFU/ml with an immunoreaction time of 15 min without any enrichment. Capture of E. coli O157:H7 by MNCs did not interfere with other bacteria, including Salmonella enteritidis, Citrobacter freundii, and Listeria monocytogenes. The capture efficiency values of MNCs increased from 69 to 94.5% as E. coli O157:H7 decreased from 3.4 x 10(7) to 8.0 x 10(0) CFU/ml in the ground beef samples prepared with minimal steps (without filtration and centrifugation). An enrichment of 6 h was done for 8.0 x 10(0) and 8.0 x 10(1) CFU/ml of E. coli O157:H7 in ground beef to increase the number of cells in the sample to a detectable level. The results also indicated that capture efficiencies of MNCs for E. coli O157:H7 with and without mechanical mixing during immunoreaction were not significantly different (P > 0.05). Compared with microbeads based immunomagnetic separation, the magnetic nanoparticles showed their advantages in terms of higher capture efficiency, no need for mechanical mixing, and minimal sample preparation.  相似文献   

11.
Pathogenic bacterial contamination is a serious problem for the food industry and in public health. Rapid, accurate and affordable testing for pathogenic bacterial strains is desirable. In this study, a competition visual antigen macroarray (CVAM) for rapid detection of Escherichia coli O157:H7 (E. coli O157:H7) has been developed. This array was able to utilize an HRP‐labeled anti‐E. coli O157:H7 MAb at a concentration of 1:20000 while having a similar sensitivity of 10 5 CFU/ml for E. coli O157:H7 detection as double antibody sandwich array and conventional ELISA. The detection time of CVAM was short as 2 h and can be examined directly by the naked eye. Moreover, there was no cross‐reactivity in the detection of tested in this study. Application of CVAM for the detection of E. coli O157:H7 artificially contaminated milk samples was feasible that showed the antigen array could be applied in the detection of food pathogen infections.  相似文献   

12.
This research aimed to detect Escherichia coli O157:H7 in milk based on immunomagnetic probe separation technology and quenching effect of gold nanoparticles to Rhodamine B. Streptavidin-modified magnetic beads (MBs) were combined with biotin-modified antibodies to capture E. coli O157:H7 specifically. Gold nanoparticle (AuNPs) was incubated with sulfhydryl-modified aptamers (SH-Aptamers) to obtain the Aptamers-AuNPs probe. After magnetic beads captured target bacteria and formed a sandwich structure with the gold nanoprobe, Rhodamine B was added into complex to obtain fluorescent signal changes. Our results demonstrated that the established method could detect E. coli O157:H7 in the range of 101–107 CFU/mL, and the limit of detection (LOD) was 0.35 CFU/mL in TBST buffer (pH = 7.4). In milk simulation samples, the LOD of this method was 1.03 CFU/mL. Our research provides a promising approach on the detection of E. coli O157:H7.  相似文献   

13.
应用DPO-PCR技术检测肠出血性大肠杆菌O157∶H7   总被引:2,自引:0,他引:2  
利用双启动寡核苷酸引物(dual-priming oligonucleotide,DPO)聚合酶链式反应(polymerase chain reaction,PCR)技术检测肠出血性大肠杆菌O157∶H7。根据DPO引物设计原则,以肠出血性大肠杆菌O157∶H7 rfbE 基因为靶基因设计一对DPO引物,经过反应体系的优化,建立了肠出血性大肠杆菌O157∶H7 DPO-PCR检测方法, 其检测灵敏度约为94 CFU/mL。与常规PCR方法相比,所建立的DPO-PCR方法对退火温度不敏感,在引物设计和实 验过程中不需要对引物及其退火温度反复优化,同时基于DPO引物的特殊结构又增强了其特异性。DPO-PCR方法 设计简易、特异性强,为致病性微生物的快速准确检测提供了新途径。  相似文献   

14.
Cross-contamination of lettuce with Escherichia coli O157:H7   总被引:2,自引:0,他引:2  
Contamination of produce by bacterial pathogens is an increasingly recognized problem. In March 1999, 72 patrons of a Nebraska restaurant were infected with enterohemorrhagic Escherichia coli (EHEC) O157:H7, and shredded iceberg lettuce was implicated as the food source. We simulated the restaurant's lettuce preparation procedure to determine the extent of possible EHEC cross-contamination and growth during handling. EHEC inoculation experiments were conducted to simulate the restaurant's cutting procedure and the subsequent storage of shredded lettuce in water in the refrigerator. All lettuce pieces were contaminated after 24 h of storage in inoculated water (2 x 10(9) CFU of EHEC per 3 liters of water) at room temperature or at 4 degrees C; EHEC levels associated with lettuce increased by > 1.5 logs on the second day of storage at 4 degrees C. All lettuce pieces were contaminated after 24 h of storage in water containing one inoculated lettuce piece (approximately 10(5) CFU of EHEC per lettuce piece) at both temperatures. The mixing of one inoculated dry lettuce piece with a large volume of dry lettuce, followed by storage at 4 degrees C or 25 degrees C for 20 h resulted in 100% contamination of the leaves tested. Microcolonies were observed on lettuce stored at 25 degrees C, while only single cells were seen on leaves stored at 4 degrees C, suggesting that bacterial growth had occurred at room temperature. Three water washes did not significantly decrease the number of contaminated leaves. Washing with 2,000 mg of calcium hypochlorite per liter significantly reduced the number of contaminated pieces but did not eliminate contamination on large numbers of leaves. Temperature abuse during storage at 25 degrees C for 20 h decreased the effectiveness of the calcium hypochlorite treatment, most likely because of bacterial growth during the storage period. These data indicate that storage of cut lettuce in water is not advisable and that strict attention must be paid to temperature control during the storage of cut lettuce.  相似文献   

15.
《Food microbiology》2002,19(2-3):159-165
A method for quantitative detection of Escherichia coli O157:H7 based on the polymerase chain reaction (PCR) was developed. The method used the NIH Image 1·61 software program to quantitatively analyse the intensity of the fluorescent image of the amplified PCR product. Based on the PCR with SLT1 and SLT2 primers used separately, a log-linear relationship between the numbers of cfu of E. coli O157:H7 inoculated into ground beef and the intensity of the PCR products was achieved with and without enrichment. Without enrichment, 150 cfu of E. coli O157:H7 per gram of ground beef were detected. In contrast, the detection limit decreased to 1·2 cfu g−1 of ground beef using SLT1 and SLT2 primers after 4·5 h of enrichment using modified EC broth with 20 μg ml−1 of novobiocin.  相似文献   

16.
The objective of this study was to develop a rapid, simple method for enhanced detection and isolation of low levels of Escherichia coli O157:H7 from leafy produce and surface water using recirculating immunomagnetic separation (RIMS) coupled with real-time PCR and a standard culture method. The optimal enrichment conditions for the method also were determined. Analysis of real-time PCR data (C(T) values) suggested that incubation of lettuce and spinach leaves rather than rinsates provides better enrichment of E. coli O157:H7. Enrichment of lettuce or spinach leaves at 42 degrees C for 5 h provided better detection than enrichment at 37 degrees C. Extended incubation of surface water for 20 h at 42 degrees C did not improve the detection. The optimized enrichment conditions were also employed with modified Moore swabs, which were used to sample flowing water sites. Positive isolation rates and real-time PCR results indicated an increased recovery of E. coli O157:H7 from all samples following the application of RIMS. Under these conditions, the method provided detection and/or isolation of E. coli O157:H7 at levels as low as 0.07 CFU/g of lettuce, 0.1 CFU/g of spinach, 6 CFU/100 ml of surface water, and 9 CFU per modified Moore swab. During a 6-month field study, modified Moore swabs yielded high isolation rates when deployed in natural watershed sites. The method used in this study was effective for monitoring E. coli O157:H7 in the farm environment, during postharvest processing, and in foodborne outbreak investigations.  相似文献   

17.
A multiplex polymerase chain reaction (PCR) procedure based on fliCh7 and rfbE genes was developed for the detection of Escherichia coli O157:H7 in raw pork meat and ready-to-eat (RTE) meat products. Two different DNA extraction procedures were evaluated for application on meat products. MasterPure™ DNA Purification kit in combination with immunomagnetic separation was found to be the best method in a meat system. The optimized PCR included an enrichment step in brilliant green bile 2% broth at 37 °C. This method was applied to artificially inoculated meat and RTE meat products with different concentrations of E. coli O157:H7. The results indicate that the PCR assay developed could sensitively and specifically detect E. coli O157:H7 in raw pork meat and RTE meat products in approximately 10 h, including a 6 h enrichment step. Thus, this method could be proposed for screening E. coli O157:H7 in raw pork and RTE meat products.  相似文献   

18.
Lateral flow assay (LFA) has been applied in many fields due to its relative ease of use and cost-effectiveness. However, it has low sensitivity and its applications are limited. Probe materials play a significant role in improving the detection efficiency and sensitivity of LFA. In this study, by using concave palladium-platinum (Pd-Pt) nanoparticles as a nanozyme probe, we developed a sensitive LFA based on the sandwich format for qualitative and quantitative detection of Escherichia coli O157:H7. The sensitivity of the LFA was improved by applying the 3,3′,5,5′-tetramethylbenzidine (TMB) substrate onto the test line where the nanozyme was accumulated in the presence of analytes. The nanozyme showed high catalytic performance toward TMB and greatly enhanced the signal intensity of the test line. The sensitivity of the nanozyme-based LFA was 9.0 × 102 cfu/mL in milk, which was 111-fold higher than that of traditional colloidal gold-based LFA. The proposed method has remarkable potential in the detection of various pathogens in real samples.  相似文献   

19.
Two sampling methods (rectoanal swabs and rectal fecal grabs) were compared for their recovery of Escherichia coli O157:H7 from feedlot cattle. Samples were collected from 144 steers four times during the finishing period by swabbing the rectoanal mucosa with cotton swabs and immediately obtaining feces from the rectum of each individual steer. The number of steers with detectable E. coli O157:H7 increased from 2 of 144 (1.4%) cattle on arrival at the feedlot to 10 of 144 (6.9%) after 1 month, 76 of 143 (52.8%) after 7 months, and 30 of 143 (20.8%) at the last sampling time before slaughter. Wilcoxon signed-rank tests indicated that the two sampling methods gave different results for sampling times 3 and 4 (P < 0.05) but not for sampling time 2 (P = 0.16). Agreement between the two sampling methods was poor (kappa < 0.2) for three of the four sampling times and moderate (kappa = 0.6) for one sampling time, an indication that in this study rectoanal swabs usually were less sensitive than rectal fecal grabs for detection of E. coli O157:H7 in cattle. Overall, the herd of origin was not significantly associated with E. coli O157:H7 results, but the weight of the steers was. Further investigation is needed to determine the effects of potential confounding factors (e.g., size and type of swab, consistency of feces, site sampled, and swabbing technique) that might influence the sensitivity of swabs in recovering E. coli O157:H7 from the rectoanal mucosa of cattle.  相似文献   

20.
Detection of Escherichia coli O157:H7 in fruit juices such as apple cider is necessary for diagnosis of infection and epidemiological investigations. However, inhibitors in the apple cider, such as endogenous polyphenols and acids, often decrease the sensitivity of PCR assays and immunoassays, thus routinely requiring laborious cell separation steps to increase the sensitivity. In the current study, polyethylene glycol (PEG)-derivatized liposomes encapsulating sulforhodamine B were tagged with anti-E. coli O157:H7 antibodies and used in an immunoliposome sandwich assay for the detection of E. coli O157:H7 in apple cider. Even without prior separation, this assay can detect E. coli O157:H7 in apple cider samples inoculated with as few as 1 CFU/ml after an 8-h enrichment period. The lower limit of detection in pure cultures without enrichment was 7 x 10(3) CFU/ml (280 CFU/40-microl sample). PEGylated immunoliposomes are suitable as an analytical reagent for the detection of E. coli O157:H7 in fruit juices containing polyphenols.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号