共查询到20条相似文献,搜索用时 0 毫秒
1.
Gravity driven ultrafiltration was operated in dead-end mode without any flushing or cleaning. In contrary to general expectations, the flux value stabilized after about one week of operation and remained constant during an extended period of time (several months). Different surface water types and diluted wastewater were used as feed water and, depending on the feed water composition, stable flux values were in the range of 4-10 L h−1 m−2. When sodium azide was added to the feed water to diminish the biological activity, no stabilization of flux occurred, indicating that biological processes play an important role in the flux stabilization process. Confocal laser scanning microscopy revealed the presence of a biofouling layer, of which the structure changed over time, leading to relatively heterogeneous structures. It is assumed that the stabilization of flux is related to the development of heterogeneous structures in the fouling layer, due to biological processes in the layer. The phenomenon of flux stabilization opens interesting possibilities for application, for instance in simple and low-cost ultrafiltration systems for decentralized drinking water treatment in developing and transition countries, independent of energy supply, chemicals, or complex process control. 相似文献
2.
对超滤技术的发展、超滤技术原理、超滤技术的特点及超滤设备的运行等做了详尽的阐述,同时着重介绍了超滤技术在饮用水深度处理、地表水处理、海水淡化、污水回用等方面的应用,最后将超滤技术的未来发展进行了展望。 相似文献
3.
4.
5.
Fate of perfluorooctanesulfonate and perfluorooctanoate in drinking water treatment processes 总被引:2,自引:0,他引:2
Takagi S Adachi F Miyano K Koizumi Y Tanaka H Watanabe I Tanabe S Kannan K 《Water research》2011,45(13):3925-3932
Perfluorooctanesulfonate (PFOS) and perfluorooctanoate (PFOA) have been recognized as global environmental pollutants. Although PFOS and PFOA have been detected in tap water from Japan and several other countries, very few studies have examined the fate, especially removal, of perfluorinated compounds (PFCs) in drinking water treatment processes. In this study, we analyzed PFOS and PFOA at every stages of drinking water treatment processes in several water purification plants that employ advanced water treatment technologies. PFOS and PFOA concentrations did not vary considerably in raw water, sand filtered water, settled water, and ozonated water. Sand filtration and ozonation did not have an effect on the removal of PFOS and PFOA in drinking water. PFOS and PFOA were removed effectively by activated carbon that had been used for less than one year. However, activated carbon that had been used for a longer period of time (>1 year) was not effective in removing PFOS and PFOA from water. Variations in the removal ratios of PFOS and PFOA by activated carbon were found between summer and winter months. 相似文献
6.
Removal or inactivation of viruses in drinking water treatment processes can be quantified by measuring the concentrations of viruses or virus indicators in water before and after treatment. Virus reduction is then calculated from the ratio of these concentrations. Most often only the average reduction is reported. That is not sufficient when treatment efficiency must be characterized in quantitative risk assessment.We present three simple models allowing statistical analysis of series of counts before and after treatment: distribution of the ratio of concentrations, and distribution of the probability of passage for unpaired and paired water samples.Performance of these models is demonstrated for several processes (long and short term storage, coagulation/filtration, coagulation/sedimentation, slow sand filtration, membrane filtration, and ozone disinfection) using microbial indicator data from full-scale treatment processes.All three models allow estimation of the variation in (log) reduction as well as its uncertainty; the results can be easily used in risk assessment. Although they have different characteristics and are present in vastly different concentrations, different viruses and/or bacteriophages appear to show similar reductions in a particular treatment process, allowing generalization of the reduction for each process type across virus groups.The processes characterized in this paper may be used as reference for waterborne virus risk assessment, to check against location specific data, and in case no such data are available, to use as defaults. 相似文献
7.
根据强化混凝技术在国内外的研究和发展状况,在分析强化混凝技术的机理及其常用方法的基础上,重点探讨了强化混凝技术的影响因素,对于自来水净化处理工艺设计具有一定帮助。 相似文献
8.
详细阐述了阳泉市污水处理厂的污水处理工艺设计及运行情况,同时总结了一些运行经验,处理后数据表明:所有出水指标均满足国家要求,处理效果良好。 相似文献
9.
Interplay of different NOM fouling mechanisms during ultrafiltration for drinking water production 总被引:6,自引:0,他引:6
Ultrafiltration is an emerging technology for drinking water production, but a main challenge remains the lack of understanding about fouling. This paper investigates the impact of molecular interactions between different natural organic matter (NOM) compounds on ultrafiltration fouling mechanisms. We performed dead-end filtration experiments with individual and mixed humic acid and alginate (polysaccharide). Alginate showed detrimental, but mostly reversible, flux decline and high solute retention. Our results indicate that this was caused by pore blocking transformed into cake building and weak molecular foulant-membrane and foulant-foulant interactions. In the presence of calcium, aggravated fouling was observed, related to complexation of alginate and its subsequently induced gel formation. With humic acid, more severe irreversible fouling occurred due to humic acid adsorption. Minor adsorption of alginate onto the membrane was also observed, which probably caused the substantial irreversible flux decline. The fouling characteristics in the mixtures reflected a combination of the individual humic acid and alginate experiments and we conclude, that the individual fouling mechanisms mutually influence each other. A model elucidates this interplay of the individual fouling mechanisms via hydrophobic and electrostatic interactions. In our study such an interplay resulted in an alginate cake, or gel in the presence of calcium, which is relatively irreversibly adsorbed onto the membrane by humic acid associations. This study shows the importance of mutual influences between various foulants for improved understanding of fouling phenomena. Furthermore it shows that substances with a minor individual influence might have a large impact in mixed systems such as natural water. 相似文献
10.
南方地区农村安全饮水工程水处理工艺研究 总被引:1,自引:0,他引:1
对南方地区水系的水质特征和变化规律进行了分析,对农村现有水处理设施和技术所面临的主要问题进行了探讨,并对各水处理单元技术进行了综合评价,最后根据南方地区农村供水要求和水源特点,提出了适宜的水处理优化组合构想。 相似文献
11.
Membrane bioreactor for the drinking water treatment of polluted surface water supplies 总被引:22,自引:0,他引:22
A laboratory membrane bioreactor (MBR) using a submerged polyethylene hollow-fibre membrane module with a pore size of 0.4 microm and a total surface area of 0.2 m2 was used for treating a raw water supply slightly polluted by domestic sewage. The feeding influent had a total organic carbon (TOC) level of 3-5 mg/L and an ammonia nitrogen (NH(3)-N) concentration of 3-4 mg/L. The MBR ran continuously for more than 500 days, with a hydraulic retention time (HRT) as short as 1h or less. Sufficient organic degradation and complete nitrification were achieved in the MBR effluent, which normally had a TOC of less than 2 mg/L and a NH(3)-N of lower than 0.2 mg/L. The process was also highly effective for eliminating conventional water impurities, as demonstrated by decreases in turbidity from 4.50+/-1.11 to 0.08+/-0.03 NTU, in total coliforms from 10(5)/mL to less than 5/mL and in UV(254) absorbance from 0.098+/-0.019 to 0.036+/-0.007 cm(-1). With the MBR treatment, the 3-day trihalomethane formation potential (THMFP) was significantly reduced from 239.5+/-43.8 to 60.4+/-23.1 microg/L. The initial chlorine demand for disinfection decreased from 22.3+/-5.1 to 0.5+/-0. 1mg/L. The biostability of the effluent improved considerably as the assimilable organic carbon (AOC) decreased from 134.5+/-52.7 to 25.3+/-19.9 microg/L. All of these water quality parameters show the superior quality of the MBR-treated water, which was comparable to or even better than the local tap water. Molecular size distribution analysis and the hydrophobic characterisation of the MBR effluent, in comparison to the filtered liquor from the bioreactor, suggest that the MBR had an enhanced filtration mechanism. A sludge layer on the membrane surface could have functioned as an additional barrier to the passage of typical THM precursors, such as large organic molecules and hydrophobic compounds. These results indicate that the MBR with a short HRT could be developed as an effective biological water treatment process to address the urgent need of many developing countries that are plagued by the serious contamination of surface water resources. 相似文献
12.
Drinking water biofilm formation on polyvinyl chloride (PVC), cross-linked polyethylene (PEX), high density polyethylene (HDPE) and polypropylene (PP) was followed in three different reactors operating under stagnant or continuous flow regimes. After one week, a quasi-steady state was achieved where biofilm total cell numbers per unit surface area were not affected by fluctuations in the concentration of suspended cells. Metabolically active cells in biofilms were around 17-35% of the total cells and 6-18% were able to form colony units in R(2)A medium. Microbiological analysis showed that the adhesion material and reactor design did not affect significantly the biofilm growth. However, operating under continuous flow (0.8-1.9 Pa) or stagnant water had a significant effect on biofilm formation: in stagnant waters, biofilm grew to a less extent. By applying mass balances and an asymptotic biofilm formation model to data from biofilms grown on PVC and HDPE surfaces under turbulent flow, specific growth rates of bacteria in the biofilm were found to be similar for both materials (around 0.15 day(-1)) and much lower than the specific growth rates of suspended bacteria (around 1.8 day(-1)). 相似文献
13.
Kinetics and mechanism for degradation of dichlorvos by permanganate in drinking water treatment 总被引:3,自引:0,他引:3
The degradation kinetics and mechanism of dichlorvos by permanganate during drinking water treatment were investigated. The reaction of dichlorvos with permanganate was of second-order overall with negligible pH dependence and an activation energy of 29.5 kJ·mol−1. At pH 7.0 and 25 °C, the rate constant was 25.2 ± 0.4 M−1 s−1. Dichlorvos was first degraded to trimethyl phosphate (TMP) and dimethyl phosphate (DMP) simultaneously which approximately accounted for <5% and ≥95% with respect to phosphorus mass, respectively. Further oxidation of DMP generated a final byproduct, monomethyl phosphate (MMP). MMP was for the first time identified as a major byproduct in chemical oxidation of dichlorvos. The kinetic model based on degradation mechanism and determined reaction rate constants allowed us to predict the evolution of dichlorvos and its byproduct concentrations during permanganate pre-oxidation process at water treatment plants. These results suggest that even though the dichlorvos concentration in surface water complies with the surface water quality standards of China (50 μg L−1), its concentration after conventional water treatment will most probably exceed the drinking water quality standards (1 μg L−1). Moreover, luminescent bacteria test shows that the acute toxicity of dichlorvos solution evidently increased after permanganate oxidation. 相似文献
14.
Andrew J. Hartshorn George Prpich Andrew Upton Jitka Macadam Bruce Jefferson Peter Jarvis 《Water and Environment Journal》2015,29(1):16-26
This investigation explores the use of five‐parameter logistic curve fitting in quantifying turbidity robustness and risk scoring in clarification and filtrations stages of several surface water treatment works in the Anglian Water region of the United Kingdom. The approach taken reviews different scoring systems and addresses issues of weighting, averages and variability in robustness performance using turbidity robustness indices (TRIs). It also proposes an area‐based risk scoring profile to assess performance [relative area profile for T90 (RAP90)]. The metrics produced are considered to be a logical and rational way to help prioritise where resources for water treatment operation should be deployed. 相似文献
15.
The current status of membrane filtration for potable water and wastewater applications is assessed with reference to recent history and key legislative drivers. The current installed capacity for potable water membrane treatment is around 1100 ML/day provided by over 100 plants, with the majority being conventional pumped systems using hollow fibre ultrafiltration (UF) or microfiltration (MF) membranes. An examination of the distribution of membrane plants reveals that capacity is provided predominantly by two commercial UF/MF membrane suppliers, but that a large number of smaller nanofiltration plants have been installed in one UK region. Future prospects for desalination are considered. 相似文献
16.
17.
纳滤用于饮用水深度处理的研究 总被引:3,自引:0,他引:3
采用纳滤膜对某市自来水进行深度处理试验,研究了纳滤对自来水中有机物及离子等的去除效果.结果表明,采用一级纳滤工艺,在回收率为70%的情况下,能有效去除自来水中的有机物、离子、内分泌干扰物和细菌等.对CODMn浊度、Cr6+和阿特拉津的平均去除率分别为81.06%,85.47%,77.20%和83.90%;对总硬度和阴离子的去除率保持在一个适中的水平;出水中未检测出细菌. 相似文献
18.
In this paper, a novel submerged ultrafiltration (UF) membrane coagulation bioreactor (MCBR) process was evaluated for drinking water treatment at a hydraulic retention time (HRT) as short as 0.5h. The MCBR performed well not only in the elimination of particulates and microorganisms, but also in almost complete nitrification and phosphate removal. As compared to membrane bioreactor (MBR), MCBR achieved much higher removal efficiencies of organic matter in terms of total organic carbon (TOC), permanganate index (COD(Mn)), dissolved organic carbon (DOC) and UV absorbance at 254nm (UV(254)), as well as corresponding trihalomethanes formation potential (THMFP) and haloacetic acids formation potential (HAAFP), due to polyaluminium chloride (PACl) coagulation in the bioreactor. However, the reduction of biodegradable dissolved organic carbon (BDOC) and assimilable organic carbon (AOC) by MCBR was only 8.2% and 10.1% higher than that by MBR, indicating that biodegradable organic matter (BOM) was mainly removed through biodegradation. On the other hand, the trans-membrane pressure (TMP) of MCBR developed much lower than that of MBR, which implies that coagulation in the bioreactor could mitigate membrane fouling. It was also identified that the removal of organic matter was accomplished through the combination of three unit effects: rejection by UF, biodegradation by microorganism and coagulation by PACl. During filtration operation, a fouling layer was formed on the membranes surface of both MCBR and MBR, which functioned as a second membrane for further separating organic matter. 相似文献
19.
Fass S Block JC Boualam M Gauthier V Gatel D Cavard J Benabdallah S Lahoussine V 《Water research》2003,37(3):493-500
The effects of discontinuous chlorination on the characteristics of the water in a pilot drinking water distribution network were investigated. The release or consumption of organic matter (as dissolved organic carbon, DOC) following chlorination and non-chlorination periods were estimated, as were changes in bacterial cell production. In each unchlorinated network 0.3 mg DOCl(-1) was consumed and the average cell production was approximately 1.3 x 10(5) cells ml(-1). In discontinously chlorinated networks (chlorine treatment: 3.3 mg Cl2l(-1), chlorine residual: 0.1 mg Cl2l(-1)) the DOC release (DOCout-DOCin) was between 0.1 and 0.2 mg Cl(-1). Biomass production (cells(out)-cells(in)) during this chlorination period was lower (approximately 2 x 10(4) cells ml(-1)). The delay before DOC was released in chlorinated networks appeared to be less than 24 h, which corresponds to one hydraulic residence time. Likewise, when chlorination was stopped, 24 h or less were required before an efficient DOC removal was resumed. When chlorination was prolonged the observed release of DOC was progressively reduced from 0.2 mg l(-1) to zero, thus after 6 weeks of continuous chlorination the DOCin was equivalent to the DOCout. 相似文献
20.
对新疆某大型输水渠道调度运行管理现状进行了论述,针对渠道运行管理中存在的问题,从水量调度管理、信息化建设、工程维修维护、机电设备保养、水管人员队伍五方面入手,提出了改进措施和建议,以保证输水渠道的安全运行。 相似文献