首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A. Ucar  M. Inalli 《Renewable Energy》2005,30(7):1005-1019
Thermal performance and economic feasibility of two types of central solar heating system with seasonal storage under four climatically different Turkey locations are investigated. The effects of storage volume and collector area on the thermal performance and cost are studied for three load sizes. The simulation model of the system consisting of flat plate solar collectors, a heat pump, under ground storage tank and heating load based on a finite element analysis and finite element code ANSYS™ is chosen as a convenient tool. In this study, the lowest solar fraction value for Trabzon (41°N) and the highest solar fraction value for Adana (37°N) are obtained. Based on the economic analysis, the payback period of system is found to be about 25–35 years for Turkey.  相似文献   

2.
A small solar crop dryer, consisting of a drying unit, thermal storage and solar collector, was designed for the climatic conditions of Papua New Guinea, and was constructed and tested at the Energy Research site of the University of Papua New Guinea. Detailed experimental studies were carried out for drying of tapioca, as well as the testing of the drying unit with and without thermal storage. Based on economic analysis, it is observed that the annual cost per kilogram of dried tapioca is about K0.27 ≠.  相似文献   

3.
In order to produce process heat for drying of agricultural, textile, marine products, heating of buildings and re-generating dehumidify agent, solar energy is one of the promising heat sources for meeting energy demand without putting adverse impact of environment. Hence it plays a key role for sustainable development. Solar energy is intermittent in nature and time dependent energy source. Owing to this nature, PCMs based thermal energy storage system can achieve the more popularity for solar energy based heating systems. The recent researches focused on the phase change materials (PCMs), as latent heat storage is more efficient than sensible heat storage. In this paper an attempt has been made to present holistic view of available solar air heater for different applications and their performance.  相似文献   

4.
A solar adsorption cooling system which can be switched between a system with heat storage and a system without heat storage was designed. In the system with heat storage, a heat storage water tank was employed as the link between the solar collector circulation and the hot water circulation for the adsorption chillers. However, the heat storage water tank was isolated in the system without heat storage, and the hot water was directly circulated between the solar collector arrays and the adsorption chillers. It was found that the inlet and outlet temperatures for the solar collector arrays and the adsorption chillers in the system without heat storage were more fluctuant than those of the system with heat storage. Also found was that the system with heat storage operated stably because of the regulating effect by the heat storage water tank. However, under otherwise similar conditions, the cooling effect of the system without heat storage was similar to that of the system with heat storage. Compared with the system with heat storage, the system without heat storage has the advantages of higher solar collecting efficiency as well as higher electrical COP.  相似文献   

5.
An experimental solar assisted heat pump space heating system with a daily energy storage tank is designed and constructed, and its thermal performance is investigated. The heating system basically consists of flat plate solar collectors, a heat pump, a cylindrical storage tank, measuring units, and a heating room located in Gaziantep, Turkey (37.1°N). All measurements are automatically collected as a function of time by means of a measurement chain feeding to a data logger in combination with a PC. Hourly and daily variations of solar radiation, collector performance, coefficient of performance of the heat pump (COPHP), and that of the overall system (COPS) are calculated to evaluate the system performance. The effects of climatic conditions and certain operating parameters on the system performance parameters are investigated. COPHP is about 2.5 for a lower storage temperature at the end of a cloudy day and it is about 3.5 for a higher storage temperature at the end of a sunny day, and it fluctuates between these values in other times. Also, COPS turns out to be about 15–20% lower than COPHP. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

6.
A straightforward analysis of a solar water heating system with n-tanks connected in series has been presented. The long-term performance of the system has also been studied. On the basis of numerical calculations made for four successive days, the following conclusions have been drawn:
1. (1) The fluctuation in temperature variation decreases with increase of the number of tanks connected in series.
2. (2) The variation becomes smooth after the second successive day, which is more desirable from the point of view of users.
  相似文献   

7.
This work describes measurements of the solar irradiance made during cloudy periods in order to improve the amount of solar energy captured during such periods. It is well-known that 2-axis tracking, in which solar modules are pointed at the sun, improves the overall capture of solar energy by a given area of modules by 30-50% versus modules with a fixed tilt. On sunny days the direct sunshine accounts for up to 90% of the total solar energy, with the other 10% from diffuse (scattered) solar energy. However, during overcast conditions nearly all of the solar irradiance is diffuse radiation that is isotropically-distributed over the whole sky. An analysis of our data shows that during overcast conditions, tilting a solar module or sensor away from the zenith reduces the irradiance relative to a horizontal configuration, in which the sensor or module is pointed toward the zenith (horizontal module tilt), and thus receives the highest amount of this isotropically-distributed sky radiation. This observation led to an improved tracking algorithm in which a solar array would track the sun during cloud-free periods using 2-axis tracking, when the solar disk is visible, but go to a horizontal configuration when the sky becomes overcast. During cloudy periods we show that a horizontal module orientation increases the solar energy capture by nearly 50% compared to 2-axis solar tracking during the same period. Improving the harvesting of solar energy on cloudy days is important to using solar energy on a daily basis for fueling fuel-cell electric vehicles or charging extended-range electric vehicles because it improves the energy capture on the days with the lowest hydrogen generation, which in turn reduces the system size and cost.  相似文献   

8.
In this paper, production of hydrogen from concentrated solar radiation is examined by a laboratory scale solar tower system that is capable of handling continuous flow photocatalysis. The system is built and studied under a solar simulator with an aiming area of 20 × 20 cm2. The fraction of solar spectrum useful for water splitting depends on the energy band gap of the selected photocatalyst. Two types of nano-particulate photocatalysts are used in this work: ZnS (3.6 eV) and CdS (2.4 eV). The effect of light concentration on photocatalysis performance is studied using Alfa Aesar 99.99% pure grade, 325 mesh ZnS nano-particles. An improved quantum efficiency of 73% is obtained as compared to 45% with the same sample under non-concentrated light in a previous study. Only 1.1% of the energy of the solar radiation spectrum can be used by ZnS catalyst. A mixture of CdS and ZnS nano-particulate photocatalysts (both Alfa Aesar 99.99% pure grade, 325 mesh) is used to conduct a parametric study for a wider spectrum capture corresponding to 18% of the incident energy. Hydrogen production increases from 0.1 mmol/h to 0.21 mmol/h when the operating conditions are varied from 25 °C and 101 kPa to 40 °C and 21 kPa absolute pressures. Furthermore, the implementation of a continuous flow process results in an improvement in the energy efficiency by a factor of 5.5 over the batch process.  相似文献   

9.
The effect of solar radiation availability on the performance of different solar heating systems has been studied. The systems include a solar water heater, passive solar houses and district solar heating systems with seasonal heat storage. Also, different collector orientations and collector types have been investigated. The hourly radiation data were generated by a simple computational simulation procedure. It was found that district solar heating systems with concentrating collectors and passive solar houses showed the largest variations for the given conditions.  相似文献   

10.
An experimental investigation has been carried out on a thermosyphon solar water heater. The system consisted of a flat-plate collector of 1.5 m2 absorber area with 21 tubes/m width and storage tank of 125 litre capacity. Experiments were carried out for both cloudy and clear weather conditions in winter and summer. The hourly system performance was evaluated for all test conditions. The final mean tank temperature was measured daily which enabled the calculation of the possible contribution of solar energy for domestic hot water supply in Basrah, Iraq (latitude 30.76°N). The system was tested at both no-load and loading conditions. Intermittent and continuous load was imposed, and system performance was evaluated for each condition.  相似文献   

11.
Analytical models have been put forward to predict the thermal performance of passive heating systems, which have previously been suggested. The systems consist of a water vessel for heat storage and a structure positioned on its outside wall, which act as a solar collector and a thermal insulation for the storage, respectively. Four different variations of structures have been considered and numerical calculations performed corresponding to the physical parameters of an earlier reported experimental study. The analysis is able to predict the experimental results fairly satisfactorily.  相似文献   

12.
In this paper, a solar combi-system which consists of solar collector and a CO2 heat pump is investigated experimentally and theoretically. Two experiments are primarily conducted to show the performance of this solar combi-system under different operation conditions. A system model is developed and validated in TRNSYS to analyze the influence of main components parameters. Subsequently, a multi-parameter optimization is carried out in GENOPT to obtain a final optimal result. The simulated results show that the optimized system can save 14.2% electricity and improve the solar fraction by 8%. The solar fraction of the optimized system can reach 71.1%. Finally, the optimized system performance is studied with the weather and load characteristics in Shanghai. Compared with the CO2 HP heating system alone, the solar assisted system can save 1790.8 kWh electricity on the basis of year round operation.  相似文献   

13.
The objective of the present work is to investigate experimentally the thermal behavior of a packed bed of combined sensible and latent heat thermal energy storage (TES) unit. A TES unit is designed, constructed and integrated with constant temperature bath/solar collector to study the performance of the storage unit. The TES unit contains paraffin as phase change material (PCM) filled in spherical capsules, which are packed in an insulated cylindrical storage tank. The water used as heat transfer fluid (HTF) to transfer heat from the constant temperature bath/solar collector to the TES tank also acts as sensible heat storage (SHS) material. Charging experiments are carried out at constant and varying (solar energy) inlet fluid temperatures to examine the effects of inlet fluid temperature and flow rate of HTF on the performance of the storage unit. Discharging experiments are carried out by both continuous and batchwise processes to recover the stored heat. The significance of time wise variation of HTF and PCM temperatures during charging and discharging processes is discussed in detail and the performance parameters such as instantaneous heat stored and cumulative heat stored are also studied. The performance of the present system is compared with that of the conventional SHS system. It is found from the discharging experiments that the combined storage system employing batchwise discharging of hot water from the TES tank is best suited for applications where the requirement is intermittent.  相似文献   

14.
This paper describes the theoretical rationale for a new low temperature phase-change desalination process, and six examples of applications to illustrate how this process can be engineered for sustainable desalination. In this process, brackish water is evaporated at near-ambient temperatures under near-vacuum pressures created by the barometric head without any mechanical energy input. Thermodynamic advantages and benefits of low temperature phase-change desalination are discussed and results from simulation studies and a prototype test system are presented. Three of the examples illustrate how the proposed process can be driven by solar energy: a) utilizing direct solar energy; b) inclusion of an external reflector; c) utilizing photovoltaic energy during non-sunlight hours. The other examples illustrate how the proposed process can be driven by waste heat: i) waste heat rejected by an absorption refrigeration unit driven by grid power; ii) waste heat rejected by an absorption refrigeration unit driven by solar collectors; and iii) waste heat rejected by an absorption refrigeration unit supported by a photovoltaic array. Merits of utilizing solar energy and process waste heat in reducing energy consumption and greenhouse gas emissions are discussed in detail.  相似文献   

15.
16.
An experimental investigation is carried out on a forced circulation solar water heater to assess its performance under various operating conditions. The system consisted of two identical collectors of total absorber area of 3.45 m2 and a storage tank of 200 litre capacity. Experiments were carried out during clear days with and without system loading for two water mass flow rates through the collector; namely 0.1305 kg/s and 0.06525 kg/s. The system was operated without thermostat control and with thermostat control at maximum and minimum settings. The collector efficiency improved with system loading. The improvement was better with increased hot water withdrawal from the system.  相似文献   

17.
Growing global concern regarding climate change motivates technological studies to minimize environmental impacts. In this context, solar water heating (SWH) systems are notably prominent in Brazil, primarily because of the abundance of solar energy in the country. However, SWH designs have not always been perfectly developed. In most projects, the installation option of the solar system only considers the electric power economy aspects and not the particular characteristics of each climatic zone. Thus, the primary objective of this paper is to assess the potential of carbon dioxide reduction with the use of SWH in comparison with electric showers in social housing in several Brazilian climatic zones. The Brazilian government authorities have created public policies to encourage the use of these technologies primarily among the low-income population. The results of this paper indicate that hot climactic regions demonstrate a low reduction of CO2 emissions with SWH installations. Thus, solar radiation is not useful for water heating in those regions, but it does lead to a large fraction of household cooling loads, implying a demand for electrical energy for air conditioning or requiring the adoption of passive techniques to maintain indoor temperatures below threshold values.  相似文献   

18.
This work presents the stability and performance characteristics of a Hybrid Solar Receiver Combustor operating in the Moderate or Intense Low oxygen Dilution (MILD) combustion regime. The device was operated at 12-kWth in two different modes of operation, i.e. combustion-only (MILD) and mixed (combustion and solar introduced into the device simultaneously), using natural gas (NG), liquefied petroleum gas (LPG), hydrogen (H2), NG/H2 and LPG/H2 blends. A 5-kWel xenon-arc lamp was used to simulate the concentrated solar radiation introduced into the device. The influence of the mode of operation and fuel composition on the combustion stability, thermal efficiency, energy balance, pollutant emissions, heat losses and distribution of heat flux within the receiver are presented for a range of values of the heat extraction. It was found that MILD combustion can be successfully stabilised within the HSRC over a broad range of operating conditions and fuel type, and in mixed operations, with low CO (for carbon-based fuels) and NOx emissions. The addition of H2 and/or concentrated solar radiation to the MILD process was found to increase its stability limits. Mixed and combustion-only operations showed similar performance, regardless of the fuel type, providing further evidence that the fuel flow rate can be used dynamically to compensate for variability in the solar resource. Also, the heat extracted from the heat exchanger and the specific fuel consumption were found to increase and decrease, respectively, by adding H2 to the system for both modes of operation, showing that hydrogen addition is beneficial. The numerical analysis revealed that the higher performance with H2 is attributable to a higher radiative heat transfer rate than for NG and LPG under MILD conditions.  相似文献   

19.
German central solar heating plants with seasonal heat storage   总被引:4,自引:0,他引:4  
Central solar heating plants contribute to the reduction of CO2-emissions and global warming. The combination of central solar heating plants with seasonal heat storage enables high solar fractions of 50% and more. Several pilot central solar heating plants with seasonal heat storage (CSHPSS) built in Germany since 1996 have proven the appropriate operation of these systems and confirmed the high solar fractions.Four different types of seasonal thermal energy stores have been developed, tested and monitored under realistic operation conditions: Hot-water thermal energy store (e.g. in Friedrichshafen), gravel-water thermal energy store (e.g. in Steinfurt-Borghorst), borehole thermal energy store (in Neckarsulm) and aquifer thermal energy store (in Rostock). In this paper, measured heat balances of several German CSHPSS are presented. The different types of thermal energy stores and the affiliated central solar heating plants and district heating systems are described. Their operational characteristics are compared using measured data gained from an extensive monitoring program. Thus long-term operational experiences such as the influence of net return temperatures are shown.  相似文献   

20.
A new combined cooling, heating and power (CCHP) system is proposed. This system is driven by solar energy, which is different from the current CCHP systems with gas turbine or engine as prime movers. This system combines a Rankine cycle and an ejector refrigeration cycle, which could produce cooling output, heating output and power output simultaneously. The effects of hour angle and the slope angle of the aperture plane for the solar collectors on the system performance are examined. Parametric optimization is conducted by means of genetic algorithm (GA) to find the maximum exergy efficiency. It is shown that the optimal slope angle of the aperture plane for the solar collectors is 60° at 10 a.m. on June 12, and the CCHP system can reach its optimal performance with the slope angle of 45° for the aperture plane at midday. It is also shown that the system can reach the maximum exergy efficiency of 60.33% under the conditions of the optimal slope angle and hour angle.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号