在已有的皮带张力非接触测量方案中,音波式皮带张力计由于受背景环境噪声干扰,会造成较大的测量误差.新出现的光电皮带张力计基本解决了这一难题,本文分析了光电式皮带张力计的测量原理,提出了基于转速标准装置的光电式皮带张力计的校准方法,并给出了不确度评定的参考方案. 相似文献
4.
5.
通过分析皮带张力计的测量原理、测量方法以及皮带使用时的实际工况,可知皮带张力计测量为皮带在张紧时的等效刚度,通过比较校准皮带张力计常用的两种皮带张力复现方式,表明直接张拉法比悬挂砝码法更加可靠。 相似文献
6.
正本文就光电式皮带张力计提出一种计量校准方法。一、工作原理光电式皮带张力计是以光学测振原理测量皮带张力的非接触式测力仪,其工作原理是通过光电传感器采集被测物体的频率信号,由微电脑软件进行数据处理,并通过公式计算得到皮带张力。光电式皮带张力计主要由光学发射器、接收器、频率测量分析单元、控制单元、显示单元和计算软件等部分构成。光电式皮带张力计根据测得的频率, 相似文献
7.
8.
9.
10.
11.
A method is proposed for estimating the parameters of a mixture of exponential and Weibull distributions for which the accuracy of preliminary estimates obtained by graphical analysis is refined in accordance with the criterion of maximum likelihood. The efficiency of the proposed method is supported by the results of statistical modeling. 相似文献
12.
An approximate analytical expression is derived for the velocity of the front of the wave of change of boiling modes on a
rod and on a plate. The impact of the Thomson effect and of the heater orientation in the gravity field is included. Adequate
agreement is demonstrated between the derived relations and experimental data. 相似文献
13.
Liebert A Wabnitz H Grosenick D Möller M Macdonald R Rinneberg H 《Applied optics》2003,42(28):5785-5792
A novel method for the determination of the optical properties of tissue from time-domain measurements is presented. The data analysis is based on the evaluation of the first moment and the second centralized moment, i.e., the mean time of flight and the variance of the measured distribution of times of flight (DTOF) of photons injected by short (picosecond) laser pulses. Analytical expressions are derived for calculation of absorption and of reduced scattering coefficients from these moments by application of diffusion theory for infinite and semi-infinite homogeneous media. The proposed method was tested on experimental data obtained with phantoms, and results for absorption and reduced scattering coefficients obtained by the proposed method are compared with those obtained by fitting of the same data with analytical solutions of the diffusion equation. Furthermore, the accuracy of the moment analysis was investigated for a range of integration limits of the DTOF. The moment analysis may serve as a comparatively fast method for evaluating optical properties with sufficient accuracy and can be used, e.g., for on-line monitoring of optical properties of biological tissue. 相似文献
14.
15.
16.
17.
水三相点是开尔文热力学温度的唯一基准点,也是ITS-90国际温标重要的定义固定点。因此,水三相点不确定度分析对整个温标的建立、温度量值传递起着至关重要的作用。近3年来,中国计量科学研究院研制出一系列高质量的水三相点容器,加强了水三相点的研究,为不确定度的分析提供了更为可靠的实验依据。同时,不确定度的分析也是客观评价新研制容器性能的一个重要指标。因此,根据实验结果对新研制容器所复现的水三相点进行了不确定度评定。评定结果表明,其扩展不确定度为0.16mK(k=2.69,P=0.99)。 相似文献