首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new 6-plex isobaric mass tagging technology is presented, and proof of principle studies are carried out using standard protein mixtures and human cerebrospinal fluid (CSF) samples. The Tandem Mass Tags (TMT) comprise a set of structurally identical tags which label peptides on free amino-terminus and epsilon-amino functions of lysine residues. During MS/MS fragmentation, quantification information is obtained through the losses of the reporter ions. After evaluation of the relative quantification with the 6-plex version of the TMT on a model protein mixture at various concentrations, the quantification of proteins in CSF samples was performed using shotgun methods. Human postmortem (PM) CSF was taken as a model of massive brain injury and comparison was carried out with antemortem (AM) CSF. After immunoaffinity depletion, triplicates of AM and PM CSF pooled samples were reduced, alkylated, digested by trypsin, and labeled, respectively, with the six isobaric variants of the TMT (with reporter ions from m/z = 126.1 to 131.1 Th). The samples were pooled and fractionated by SCX chromatography. After RP-LC separation, peptides were identified and quantified by MS/MS analysis with MALDI TOF/TOF and ESI-Q-TOF. The concentration of 78 identified proteins was shown to be clearly increased in PM CSF samples compared to AM. Some of these proteins, like GFAP, protein S100B, and PARK7, have been previously described as brain damage biomarkers, supporting the PM CSF as a valid model of brain insult. ELISA for these proteins confirmed their elevated concentration in PM CSF. This work demonstrates the validity and robustness of the tandem mass tag (TMT) approach for quantitative MS-based proteomics.  相似文献   

2.
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) is a central tool for proteomic analysis, yet the singly protonated tryptic peptide ions produced by MALDI are significantly more difficult to dissociate for tandem mass spectrometry (MS/MS) than the corresponding multiply protonated ions. In order to overcome this limitation, current proteomic approaches using MALDI-MS/MS involve high-energy collision-induced dissociation (CID). Unfortunately, the use of high-energy CID complicates product ion spectra with a significant proportion of irrelevant fragments while also reducing mass accuracy and mass resolution. In order to address the lack of a high-resolution, high mass accuracy MALDI-MS/MS platform for proteomics, Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) and a recently developed MS/MS technique termed CIRCA (for combination of infrared and collisional activation) have been applied to proteomic analysis. Here, CIRCA is shown to be suitable for dissociating singly protonated tryptic peptides, providing greater sequence coverage than either CID or infrared multiphoton dissociation (IRMPD) alone. Furthermore, the CIRCA fragmentation spectra are of sufficient quality to allow protein identification based on the MS/MS spectra alone or in concert with the peptide mass fingerprint (PMF). This is accomplished without compromising mass accuracy or mass resolution. As a result, CIRCA serves to enable MALDI-FTICR-MS/MS for high-performance proteomics experiments.  相似文献   

3.
Here we describe a new quadrupole Fourier transform ion cyclotron resonance hybrid mass spectrometer equipped with an intermediate-pressure MALDI ion source and demonstrate its suitability for "bottom-up" proteomics. The integration of a high-speed MALDI sample stage, a quadrupole analyzer, and a FT-ICR mass spectrometer together with a novel software user interface allows this instrument to perform high-throughput proteomics experiments. A set of linearly encoded stages allows sub-second positioning of any location on a microtiter-sized target with up to 1536 samples with micrometer precision in the source focus of the ion optics. Such precise control enables internal calibration for high mass accuracy MS and MS/MS spectra using separate calibrant and analyte regions on the target plate, avoiding ion suppression effects that would result from the spiking of calibrants into the sample. An elongated open cylindrical analyzer cell with trap plates allows trapping of ions from 1000 to 5000 m/z without notable mass discrimination. The instrument is highly sensitive, detecting less than 50 amol of angiotensin II and neurotensin in a microLC MALDI MS run under standard experimental conditions. The automated tandem MS of a reversed-phase separated bovine serum albumin digest demonstrated a successful identification for 27 peptides covering 45% of the sequence. An automated tandem MS experiment of a reversed-phase separated yeast cytosolic protein digest resulted in 226 identified peptides corresponding to 111 different proteins from 799 MS/MS attempts. The benefits of accurate mass measurements for data validation for such experiments are discussed.  相似文献   

4.
Enhanced charging, or supercharging, of analytes in electrospray ionization mass spectrometry (ESI MS) facilitates high resolution MS by reducing an ion mass-to-charge (m/z) ratio, increasing tandem mass spectrometry (MS/MS) efficiency. ESI MS supercharging is usually achieved by adding a supercharging reagent to the electrospray solution. Addition of these supercharging reagents to the mobile phase in liquid chromatography (LC)-MS/MS increases the average charge of enzymatically derived peptides and improves peptide and protein identification in large-scale bottom-up proteomics applications but disrupts chromatographic separation. Here, we demonstrate the average charge state of selected peptides and proteins increases by introducing the supercharging reagents directly into the ESI Taylor cone (in-spray supercharging) using a dual-sprayer ESI microchip. The results are comparable to those obtained by the addition of supercharging reagents directly into the analyte solution or LC mobile phase. Therefore, supercharging reaction can be accomplished on a time-scale of ion liberation from a droplet in the ESI ion source.  相似文献   

5.
Electron transfer dissociation (ETD) has improved the mass spectrometric analysis of proteins and peptides with labile post-translational modifications and larger intact masses. Here, the parameters governing the reaction rate of ETD are examined experimentally. Currently, due to reagent injection and isolation events as well as longer reaction times, ETD spectra require significantly more time to acquire than collision-induced dissociation (CID) spectra (>100 ms), resulting in a trade-off in the dynamic range of tandem MS analyses when ETD-based methods are compared to CID-based methods. Through fine adjustment of reaction parameters and the selection of reagents with optimal characteristics, we demonstrate a drastic reduction in the time taken per ETD event. In fact, ETD can be performed with optimal efficiency in nearly the same time as CID at low precursor charge state (z = +3) and becomes faster at higher charge state (z > +3).  相似文献   

6.
A novel highly sensitive strategy is introduced for analysis of tyrosine phosphorylation in previously identified proteins channelling for this aim all analytical and sequence information available. Nanoelectrospray high-resolution MS/MS analysis is targeted to precalculated m/z values corresponding to phosphotyrosine-containing tryptic peptides. Identification of these peptides is supported by the occurrence of the phosphotyrosine immonium ion at m/z 216, neutral loss of 79.97/z (= loss of HPO3), and similarity of the fragmentation patterns of phosphotyrosine-containing peptides with their nonphosphorylated analogues. This tyrosine-targeted tandem mass spectrometry strategy is demonstrated for epidermal growth factor receptor showing that phosphotyrosine-containing tryptic peptides invisible in the survey spectrum can be safely identified.  相似文献   

7.
Liu H  Zhang Y  Wang J  Wang D  Zhou C  Cai Y  Qian X 《Analytical chemistry》2006,78(18):6614-6621
The mass spectrometry-based methods with a stable isotope as the internal standard in quantitative proteomics have been developed quickly in recent years. But the use of some stable isotope reagents is limited by the relative high price and synthetic difficulties. We have developed a new method for quantitative proteomics research by using metal element chelated tags (MECT) coupled with mass spectrometry. The bicyclic anhydride diethylenetriamine-N,N,N',N' ',N' '-pentaacetic acid (DTPA) is covalently coupled to primary amines of peptides, and the ligand is then chelated to the rare earth metals Y and Tb. The tagged peptides are mixed and analyzed by LC-ESI-MS/MS. Peptides are quantified by measuring the relative signal intensities for the Y and Tb tag pairs in MS, which permits the quantitation of the original proteins generating the corresponding peptides. The protein is then identified by the corresponding peptide sequence from its MS/MS spectrum. The MECT method was evaluated by using standard proteins as model sample. The experimental results showed that metal chelate-tagged peptides chromatographically coeluted successfully during the reversed-phase LC analysis. The relative quantitation results were accurate for proteins using MECT. DTPA modification of the N-terminal of peptides promoted cleaner fragmentation (only y-series ions) in mass spectrometry and improved the confidence level of protein identification. The MECT strategy provides a simple, rapid, and economical alternative to current mass tagging technologies available.  相似文献   

8.
The development of methods to chemically modify and isolate cysteinyl-residue-containing peptides (Cys-peptides) for LC-MS/MS analysis has generated considerable interest in the field of proteomics. Methods using isotope-coded affinity tags (ICAT) and (+)-biotinyl-iodoacetamidyl-3,6-dioxaoctanediamine (iodoacetyl-PEO-biotin) employ similar Cys-modifying reagents that contain a thiolate-specific biotin group to modify and isolate Cys-containing peptides in conjunction with immobilized avidin. For these strategies to be effective on a proteome-wide level, the presence of the ICAT or acetyl-PEO-biotin tag should not interfere with the efficiency of induced dissociation in MS/MS experiments or with the identification of the modified Cys-peptides by automated database searching algorithms. We have compared the collision-induced dissociation (CID) fragmentation patterns of peptides labeled with iodoacetyl-PEO-biotin and the ICAT reagent to those of the unmodified peptides. CID of Cys-peptides modified with either reagent resulted in the formation of ions attributed to the modified Cys-peptides as well as those unique to the labeling reagent. As demonstrated by analyzing acetyl-PEO-biotin labeled peptides from ribonuclease A and the ICAT-labeled proteome of Deinococcus radiodurans, the presence of these label-specific product ions provides a useful identifier to discern whether a peptide has been modified with the Cys-specific reagent, especially when a number of peptides analyzed using these methods do not contain a modified Cys residue, and to differentiate identical Cys-peptides labeled with either ICAT-d0 or ICAT-d8.  相似文献   

9.
Proteomics has grown significantly with the aid of new technologies that consistently are becoming more streamlined. While processing of proteins from a whole cell lysate is typically done in a bottom-up fashion utilizing MS/MS of peptides from enzymatically digested proteins, top-down proteomics is becoming a viable alternative that until recently has been limited largely to offline analysis by tandem mass spectrometry. Here we describe a method for high-resolution tandem mass spectrometery of intact proteins on a chromatographic time scale. In a single liquid chromatography-tandem mass spectrometry (LC-MS/MS) run, we have identified 22 yeast proteins with molecular weights from 14 to 35 kDa. Using anion exchange chromatography to fractionate a whole cell lysate before online LC-MS/MS, we have detected 231 metabolically labeled (14N/15N) protein pairs from Saccharomyces cerevisiae. Thirty-nine additional proteins were identified and characterized from LC-MS/MS of selected anion exchange fractions. Automated localization of multiple acetylations on Histone H4 was also accomplished on an LC time scale from a complex protein mixture. To our knowledge, this is the first demonstration of top-down proteomics (i.e., many identifications) on linear ion trap Fourier transform (LTQ FT) systems using high-resolution MS/MS data obtained on a chromatographic time scale.  相似文献   

10.
Time-of-flight mass spectrometry (TOF MS) is increasingly used in proteomics research. Herein, we report on the development and characterization of a TOF MS instrument with improved sensitivity equipped with an electrodynamic ion funnel trap (IFT) that employs an automated gain control (AGC) capability. The IFT-TOF MS was coupled to a reversed-phase capillary liquid chromatography (RPLC) separation and evaluated in experiments with complex proteolytic digests. When applied to a global tryptic digest of Shewanella oneidensis proteins, an order-of-magnitude increase in sensitivity compared to that of the conventional continuous mode of operation was achieved due to efficient ion accumulation prior to TOF MS analysis. As a result of this sensitivity improvement and related improvement in mass measurement accuracy, the number of unique peptides identified in the AGC-IFT mode was 5-fold greater than that obtained in the continuous mode.  相似文献   

11.
As the process of top-down mass spectrometry continues to mature, we benchmark the next installment of an improving methodology that incorporates a tube-gel electrophoresis (TGE) device to separate intact proteins by molecular mass. Top-down proteomics is accomplished in a robust fashion to yield the identification of hundreds of unique proteins, many of which correspond to multiple protein forms. The TGE platform separates 0-50 kDa proteins extracted from the yeast proteome into 12 fractions prior to automated nanocapillary LC-MS/MS in technical triplicate. The process may be completed in less than 72 h. From this study, 530 unique proteins and 1103 distinct protein species were identified and characterized, thus representing the highest coverage to date of the Saccharomyces cerevisiae proteome using top-down proteomics. The work signifies a significant step in the maturation of proteomics based on direct measurement and fragmentation of intact proteins.  相似文献   

12.
13.
Dynamic range and the presence of highly abundant proteins limit the number of proteins that may be identified within a complex mixture. Cysteine (Cys) has unique chemical reactivity that may be exploited for chemical tagging/capture with biotin/avidin reagents or affinity chromatography allowing specific isolation and subsequent identification of peptide sequences by mass spectrometry. Organomercurial agarose (Hg-beads) specifically captures Cys-containing peptides and proteins from cell lysates. Tryptic peptides from yeast lysates containing Cys were captured and eluted from Hg-beads after incubation with TCEP and trypsin. From two 1 h nano 1-D LC DDA/MS of the eluate >700 proteins were identified with an estimated false positive rate of approximately 1%. Few peptides were identified with high confidence without Cys within their sequence after capture, and extensive washing, indicating little nonspecific binding. The number of fragmentation spectra was increased using automated 2-D nano-LC/MS and allowed identification of 1496 proteins with an estimated false positive rate of 1.1%. Approximately 4% of the proteins identified were from peptides that did not contain Cys, and these were biased toward higher abundance proteins. Comparison of the 1496 proteins to those reported previously showed that >25% were from yeast proteins not previously observed. Most proteins were identified from a single peptide, and sequence coverage was sacrificed by focusing only on identifying Cys-containing peptides, but large numbers of proteins were rapidly identified by eliminating many of the peptides from the higher abundance proteins.  相似文献   

14.
We describe approaches for proteomics analysis using electrospray ionization-tandem mass spectrometry coupled with fast reversed-phase liquid chromatography (RPLC) separations. The RPLC separations used 50-microm-i.d. fused-silica capillaries packed with submicrometer-sized C18-bonded porous silica particles and achieved peak capacities of 130-420 for analytes from proteome tryptic digests. When these separations were combined with linear ion trap tandem mass spectrometry measurements, approximately 1000 proteins could be identified in 50 min from approximately 4000 identified tryptic peptides; approximately 550 proteins in 20 min from approximately 1800 peptides; and approximately 250 proteins in 8 min from approximately 700 peptides for a S. oneidensis tryptic digest. The dynamic range for protein identification with the fast separations was determined to be approximately 3-4 orders of magnitude of relative protein abundance on the basis of known proteins in human blood plasma analyses. We found that 55% of the MS/MS spectra acquired during the entire analysis (and up to 100% of the MS/MS spectra acquired from the most data-rich zone) provided sufficient quality for identifying peptides. The results confirm that such analyses using very fast (minutes) RPLC separations based on columns packed with microsized porous particles are primarily limited by the MS/MS analysis speed.  相似文献   

15.
Wang N  Li L 《Analytical chemistry》2008,80(12):4696-4710
In shotgun proteome analysis by liquid chromatography-tandem mass spectrometry (LC-MS/MS), not all coeluting peptides at a given retention time are subjected to MS/MS due to the limitation of spectral acquisition speed of a mass spectrometer. In this work, precursor ion exclusion (PIE) in an electrospray ionization (ESI) quadrupole time-of-flight (QTOF) mass spectrometer was explored as a means of mitigating the undersampling problem. This strategy is based on running replicates of the sample where the precursor ions detected in the initial run(s) are excluded for MS/MS in the subsequent run. Four PIE methods as well as running replicates without PIE were investigated and compared for their effectiveness in identifying peptides and proteins. In the analysis of an MCF-7 breast cancer cell lysate digest by three replicate 2 h gradient LC-ESI runs, the first PIE method used a list of precursor ions detected in the initial run(s) for exclusion and identified a total of 572 proteins from the three runs combined with an average of 3.59 peptides matched to a protein. The second PIE method involved in the generation of a list of m/ z values of precursor ions along with their retention time information from the initial run(s), followed by entering these ions with retention times into the ion exclusion program of the QTOF control software for exclusion at a predefined retention time window (i.e., +/-150 s). In comparison to the first PIE method, this method reduced the possibility of excluding different peptide ions of the same m/ z (within a mass tolerance window) eluted at different retention windows. A total of 657 proteins were identified with an average of 3.75 peptides matched to a protein. The third PIE method studied relied on the exclusion of the precursor ions of peptides identified through database search of the MS/MS spectra generated in the initial run(s). This selective PIE method identified a total of 681 proteins with an average of 3.68 peptides matched to a protein. The final PIE method investigated involves the expansion of the selective PIE list by including nonidentifiable peptide ions found in the database search. This complete PIE method identified a total of 726 proteins with an average of 3.66 peptides per protein. In the case of three replicate runs without PIE, a total of 460 proteins were identified with an average of 3.51 peptides matched to a protein. Thus, the use of an optimal PIE strategy significantly increased the number of proteins identified from replicate runs (i.e., 726 vs 460 or a 58% increase). It is further demonstrated that this PIE strategy also improves protein identification efficiency in the analysis of a yeast whole cell lysate digesta less complex proteome digest. A total of 533 proteins identified from five replicate runs with complete PIE, compared to 353 proteins identified from the five replicate runs without PIE, representing a 51% increase in the number of proteins identified.  相似文献   

16.
For localization of deuterium atoms after solution-phase exchange with D2O, intact proteins are often digested prior to analysis by mass spectrometry (MS) and tandem MS (MS/MS). Amelioration of limitations associated with this approach (e.g., <70% sequence coverage and some D atom scrambling during MS/MS) were sought using intact proteins and two newer methods applied to tracking H/D exchange dynamics for the first time. Using 2-4-fold signal enhancements through depletion of 13C and 15N isotopes and implementing the new MS/MS technique of electron capture dissociation (ECD) yielded an increased number of c and z* ions observed (43 vs 25) for recombinant yeast ubiquitin (9.3 kDa). Initial determination of D atom content in consecutive c ion series (c4-c7, c28, c31, c32, and c33) was demonstrated. The improved ion signal and experiment speed combined with narrower isotopic distributions markedly increases the degree of localization and feasibility of ECD-based MS/MS after solution-phase H/D exchange.  相似文献   

17.
Due to the complexity of proteome samples, only a portion of peptides and thus proteins can be identified in a single LC-MS/MS analysis in current shotgun proteomics methodologies. It has been shown that replicate runs can be used to improve the comprehensiveness of the proteome analysis; however, high-intensity peptides tend to be analyzed repeatedly in different runs, thus reducing the chance of identifying low-intensity peptides. In contrast to commonly used online ESI-MS, offline MALDI decouples the separation from MS acquisition, thus allowing in-depth selection for specific precursor ions. Accordingly, we extended a strategy for offline LC-MALDI MS/MS analysis using a precursor ion exclusion list consisting of all identified peptides in preceding runs. The exclusion list eliminated redundant MS/MS acquisitions in subsequent runs, thus reducing MALDI sample depletion and allowing identification of a larger number of peptide identifications in the cumulative dataset. In the analysis of the digest of an Escherichia coli lysate, the exclusion list strategy resulted in a 25% increase in the number of unique peptide identifications in the second run, in contrast to simply pooling MS/MS data from two replicate runs. To reduce the increased LC analysis time for repeat runs, a four-column multiplexed LC system was developed to carry out separation simultaneously. The multiplexed LC-MALDI MS provides a high-throughput platform to utilize the exclusion list strategy in proteome analysis.  相似文献   

18.
Online liquid chromatography-mass spectrometric (LC-MS) analysis of intact proteins (i.e., top-down proteomics) is a growing area of research in the mass spectrometry community. A major advantage of top-down MS characterization of proteins is that the information of the intact protein is retained over the vastly more common bottom-up approach that uses protease-generated peptides to search genomic databases for protein identification. Concurrent to the emergence of top-down MS characterization of proteins has been the development and implementation of the stable isotope labeling of amino acids in cell culture (SILAC) method for relative quantification of proteins by LC-MS. Herein we describe the qualitative and quantitative top-down characterization of proteins derived from SILAC-labeled Aspergillus flavus using nanoflow reversed-phase liquid chromatography directly coupled to a linear ion trap Fourier transform ion cyclotron resonance mass spectrometer (nLC-LTQ-FTICR-MS). A. flavus is a toxic filamentous fungus that significantly impacts the agricultural economy and human health. SILAC labeling improved the confidence of protein identification, and we observed 1318 unique protein masses corresponding to 659 SILAC pairs, of which 22 were confidently identified. However, we have observed some limiting issues with regard to protein quantification using top-down MS/MS analyses of SILAC-labeled proteins. The role of SILAC labeling in the presence of competing endogenously produced amino acid residues and its impact on quantification of intact species are discussed in detail.  相似文献   

19.
The extension of quantitation methods for small peptides to ions above 5 kDa, and eventually to global quantitative proteomics of intact proteins, will require extensive refinement of current analytical approaches. Here we evaluate postgrowth Cys-labeling and 14N/15N metabolic labeling strategies for determination of relative protein expression levels and their posttranslational modifications using top-down mass spectrometry (MS). We show that intact proteins that are differentially alkylated with acrylamide (+71 Da) versus iodoacetamide (+57 Da) have substantial chromatographic shifts during reversed-phase liquid chromatography separation (particularly in peak tails), indicating a requirement for stable isotopes in alkylation tags for top-down MS. In the 14N/15N metabolic labeling strategy, we achieve 98% 15N incorporation in yeast grown 10 generations under aerobic conditions and determine 50 expression ratios using Fourier transform ion cyclotron resonance MS in comparing these cells to anaerobically grown control (14N) cells. We devise quantitative methods for top-down analyses, including a correction factor for accurate protein ratio determination based upon the signal-to-noise ratio. Using a database of 200 yeast protein forms identified previously by top-down MS, we verify the intact mass tag concept for protein identification without tandem MS. Overall, we find that top-down MS promises work flows capable of large-scale proteome profiling using stable isotope labeling and the determination of >5 protein ratios per spectrum.  相似文献   

20.
A general approach that combines mass spectrometry (MS), collision-induced dissociation (CID), ion mobility (IM), and MS for top-down proteomics is described, denoted as MS-CID-IM-MS. Using this approach, CID product ions are dispersed in two dimensions, specifically size-to-charge (IM) and mass-to-charge (MS), and the resulting 2D data display greatly facilitates peptide/protein mass mapping, amino acid sequence analysis, and determination of site-specific protein modifications. Also, this approach alleviates some of the inherent limitations of top-down proteomics, viz. the limitations in dynamic range for fragment ion abundances owing to the number of fragmentation channels available to large ionic systems as well as the resulting spectral congestion. For large peptides such as melittin (2845 Da), CID of the [M + 3H](3+), [M + 4H](4+), and [M + 5H](5+) ions yields amino acid sequence coverage of 42.3%, 38.5%, and 7.7%, respectively, whereas the hybrid MS-CID-IM-MS approach yields amino acid sequence coverages of 84.6%, 65.4%, and 69.2%, respectively. For large biomolecules such as ubiquitin (8565 Da), the amino acid sequence coverage increases from 39% to 76%. The MS-CID-IM-MS top-down approach allows for greater depth of information by allowing the assignment and study of internal fragment ions. Lastly, analysis of the methyl esterification of ubiquitin and single point mutation of human iron sulfur cluster U (HISCU, 14.3 kDa) demonstrates the ability of MS-CID-IM-MS to rapidly identify the presence and sites of modifications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号