首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Theatres are the most complex of all auditorium structures environmentally. They usually have high heat loads, which are of a transient nature as audiences come and go, and from lighting which changes from scene to scene, and they generally have full or nearly full occupancy. Theatres also need to perform well acoustically, both for the spoken word and for music, and as sound amplification is less used than in other auditoria, background noise control is critically important. All these factors place constraints on the ventilation design, and if this is poor, it can lead to the deterioration of indoor air quality and thermal comfort. To analyse the level of indoor air quality and thermal comfort in a typical medium-sized mechanically ventilated theatre, and to identify where improvements could typically be made, a comprehensive post-occupancy evaluation study was carried out on a theatre in Belgrade. The evaluation, based on the results of monitoring (temperature, relative humidity, CO2, air speed and heat flux) and modelling (CFD), as well as the assessment of comfort and health as perceived by occupants, has shown that for most of the monitored period the environmental parameters were within the standard limits of thermal comfort and IAQ. However, two important issues were identified, which should be borne in mind by theatre designers in the future. First, the calculated ventilation rates showed that the theatre was over-ventilated, which will have serious consequences for its energy consumption, and secondly, the displacement ventilation arrangement employed led to higher than expected complaints of cold discomfort, probably due to cold draughts around the occupants’ feet.  相似文献   

2.
In Kuwait, as in most countries with a typical dry desert climate, the summer season is long with a mean daily maximum temperature of 45 °C. Centralized air-conditioning, which is generally deployed from the beginning of April to the end of October, can have tremendous impact on the amount of electrical energy utilized to mechanically control the internal environment in mosque buildings. The indoor air temperature settings for all types of air-conditioned buildings and mosque buildings in particular, are often calculated based on the analytical model of ASHRAE 55-2004 and ISO 7730. However, a field study was conducted in six air-conditioned mosque buildings during the summers of 2007 to investigate indoor climate and prayers thermal comfort in state of Kuwait. The paper presents statistical data about the indoor environmental conditions in Kuwait mosque buildings, together with an analysis of prayer thermal comfort sensations for a total of 140 subjects providing 140 sets of physical measurements and subjective questionnaires were used to collect data. Results show that the neutral temperature (Tn) of the prayers is found to be 26.1 °C, while that for PMV is 23.3 °C. Discrepancy of these values is in fact about 2.8 °C higher than those predicted by PMV model. Therefore, thermal comfort temperature in Kuwait cannot directly correlate with ISO 7730 and ASHRAE 55-2004 standards. Findings from this study should be considered when designing air conditioning for mosque buildings. This knowledge can contribute towards the development of future energy-related design codes for Kuwait.  相似文献   

3.
In the warm and humid climate zone, air-conditioning (AC) is usually provided at working places to enhance human thermal comfort and work productivity. From the building sustainability point of view, to achieve acceptable thermal sensation with the minimum use of energy can be desirable. A new AC design tactic is then to increase the air movement so that the summer temperature setting can be raised. A laboratory-based thermal comfort survey was conducted in Hong Kong with around 300 educated Chinese subjects. Their thermal sensation votes were gathered for a range of controlled thermal environment. The result analysis shows that, like in many other Asian cities, the thermal sensation of the Hong Kong people is sensitive to air temperature and speed, but not much to humidity. With bodily air speed at 0.1–0.2 m/s, clothing level 0.55 clo and metabolic rate 1 met, the neutral temperature was found around 25.4 °C for sedentary working environment. Then recommendations are given to the appropriate controlled AC environment in Hong Kong with higher airflow speeds.  相似文献   

4.
Ventilation, heating and cooling systems in industrial premises are important issues as they are related to both energy cost and indoor climate management and the health of the premises’ occupants. The present paper has two aims: (1) to evaluate the performance of Computational Fluid Dynamics (CFD) for planning new or renovating existing industrial ventilation systems, and (2) to evaluate the performance of two different supply principles in a contaminant-intensive process with temperature and density stratification.  相似文献   

5.
Previous studies have found that classrooms are often inadequately ventilated, with the resultant increased risk of negative impacts on the pupils. This paper describes a series of field measurements that investigated the indoor air quality, thermal comfort and acoustic performance of nine recently built secondary schools in England. The most significant conclusion is that the complex interaction between ventilation, thermal comfort and acoustics presents considerable challenges for designers. The study showed that while the acoustic standards are demanding it was possible to achieve natural ventilation designs that met the criteria for indoor ambient noise levels when external noise levels were not excessive. Most classrooms in the sample met the requirement of limiting the daily average CO2 concentration to below 1500 ppm but just a few met the need to readily provide 8 l/s per person of fresh air under the easy control of the occupants. It would seem that the basic requirement of 1500 ppm of CO2 is achieved as a consequence of the window areas being just sufficient to provide the minimum of 3 l/s per person at low and intermittent occupancy. Thermal comfort in the monitored classrooms was mostly acceptable but temperatures tended to be much higher in practice than the design assumed.  相似文献   

6.
The indoor environmental quality (IEQ) in residential buildings is examined from the prospect of an occupant's acceptance in four aspects: thermal comfort, indoor air quality, noise level and illumination level. Based on the evaluations by 125 occupants living in 32 typical residential apartments in Hong Kong, this study proposes empirical expressions to approximate the overall IEQ acceptance with respect to four contributors, namely operative temperature, carbon dioxide concentration, equivalent noise level and illumination level, via a multivariate logistic regression model. A range of IEQ acceptances for regular residential conditions is determined and the dependence of the predicted overall IEQ acceptance on the variations of the contributors is discussed. The proposed overall IEQ acceptance can be used as a quantitative assessment criterion for similar residential environments where an occupant's evaluation is expected.  相似文献   

7.
Current Building Management System (BMS) does not integrate well with real-time occupant response. In order to fine-tune the system to meet individual demands and to maximize the occupant acceptance of indoor thermal environment, a new notion of Bayesian control algorithm was developed in this study. Control parameters of a weighting function for air temperature control (namely, the control temperature constant kT and the probable acceptance of the air temperature set-point λ) and two prior distribution functions of air temperature set-point, namely the uniform prior and the expert's prior, were examined. Optimum air temperature set-points of air-conditioning systems obtained from certain Hong Kong offices were then used to demonstrate the applicability of the new algorithm for controlling an example air temperature set-point ranged between 0.2 °C and 1 °C. This algorithm would be useful for adaptive thermal comfort control in a large, post-occupied air-conditioned space.  相似文献   

8.
Mold specific quantitative PCR (MSQPCR) was used to measure the concentrations of the 36 mold species in indoor and outdoor air samples that were taken simultaneously for 48 h in and around 17 homes in Cincinnati, Ohio. The total spore concentrations of 353 per m(3) of indoor air and 827 per m(3) of outdoor air samples were significantly different (por=0.5). These results suggest that interpretation of the meaning of short-term (<48 h) mold measurements in indoor and outdoor air samples must be made with caution.  相似文献   

9.
When an air-source heat pump (ASHP) unit is used for space heating at a low ambient temperature in winter, frost may be formed on its outdoor coil surface. Frosting affects its operational performance and energy efficiency, and therefore periodic defrosting is necessary. Currently, the most widely used standard defrosting method for ASHP units is reverse-cycle defrost. During a standard reverse-cycle defrosting process, the indoor coil in an ASHP unit actually acts as an evaporator, therefore, no heating is provided and hence indoor air temperature in a heated space can drop. Furthermore, a longer period of time is needed before space heating can become available immediately after the completion of defrosting. Consequently, occupants’ thermal comfort may be adversely affected. To improve the indoor thermal comfort for occupants during reverse-cycle defrosting, a novel thermal energy storage (TES) based reverse-cycle defrosting method has been developed and the improvement to occupants’ thermal comfort experimentally evaluated and is reported in this paper. Comparative experiments using both the novel TES based reverse-cycle defrosting method and the standard reverse-cycle defrosting method were carried out. Experimental results and the evaluated indoor thermal comfort indexes clearly suggested that when compared to the use of standard reverse-cycle defrost, the use of the novel reverse-cycle defrosting method can help achieve improved indoor thermal comfort, with a shorter defrosting period and a higher indoor supply air temperature during defrosting.  相似文献   

10.
Yu J  Ouyang Q  Zhu Y  Shen H  Cao G  Cui W 《Indoor air》2012,22(2):110-118
It has been reported previously that people who are acclimated to naturally ventilated (NV) environments respond to hot and warm environments differently than people who are acclimated to air-conditioned (AC) environments. However, it is not clear whether physiological acclimatization contributes to this discrepancy. To study whether living and working in NV or AC environments for long periods of time can lead to different types of physiological acclimatization, and whether physiological acclimatization has an important influence on people's responses of thermal comfort, measurements of physiological reactions (including skin temperature, sweat rate, heart rate variability, and heat stress protein 70) and thermal comfort responses were conducted in a 'heat shock' environment (climate chamber) with 20 people (10 in the NV group and 10 in the AC group). The results showed that the NV group had a significantly stronger capacity for physiological regulation to the heat shock than the AC group. In other words, the NV group did not feel as hot and uncomfortable as the AC group did. These results strongly indicate that living and working in indoor thermal environments for long periods of time affects people's physiological acclimatization. Also, it appears that long-term exposure to stable AC environments may weaken people's thermal adaptability. PRACTICAL IMPLICATIONS: This study examined the psychological and physiological differences of thermal adaptability of people used to air-conditioned environments and naturally ventilated environments. The results suggested that long-term exposure to stable air-conditioned environments may weaken people's thermal adaptability. Therefore, it might be advantageous for people to spend less time in static air-conditioned environments; this is not only because of its possible deleterious impact on people's physiological adaptability, but also because the air-conditioners' high-energy consumption will contribute to the effects of global warming.  相似文献   

11.
With rapid urbanization, big cities in the south of China are progressively falling short of sustaining outdoor thermal comfort. In this paper, a thermal comfort and energy evaluation model is derived from revisions of previous study, to simulate and predict the interaction of coupled urban building-site climate and then the thermal comfort. The methodology of principal calculations is demonstrated first, then a hypothetical district of office buildings in Shanghai is selected. Dynamic on-site climate parameters, anthropogenic heat and indoor/outdoor SET* values, etc., are simulated and evaluated. The results show the variation of outdoor SET* values influenced by factors including canopy height, building coverage and air-conditioning set-point temperature.  相似文献   

12.
The characteristics of thermal comfort and indoor air quality (IAQ) in bedrooms, occupants’ perceptions and their impact on sleep quality are not often studied. It becomes even more interesting if climatic conditions allow Naturally/Mechanically Ventilated (NMV) concepts as opposed to Air-conditioning (AC) and this becomes very significant from an energy perspective. This paper reports our findings from such a study conducted in a hot and humid climate. Objective measurements of thermal comfort and IAQ were carried out during sleeping period in 12 NMV and 12 AC bedrooms over a period of 2 months. Questionnaire responses were sought from each subject at the end of the objective measurements to assess their perceptions on thermal comfort and indoor air quality of the bedrooms during sleep and their sleeping conditions. Although the “Historical” and “Immediate” responses for the NMV and AC bedrooms indicate that there was a good level of acceptability for both Thermal Comfort and Perceived Air Quality (PAQ), it was found that NMV bedroom was a better sleeping environment. The subjects’ immediate perception of PAQ and thermal comfort were reasonably correlated with their historical perceptions. The subjects’ perception of PAQ was fairly closely correlated to their perception of Thermal Comfort. There was a considerable increase in the carbon dioxide level in an AC bedroom relative to a NMV bedroom. However, there was no clear evidence to substantiate that sleeping duration decreased with increasing level of carbon dioxide, but the findings do suggest that high level of carbon dioxide may hinder the duration of sleep.  相似文献   

13.
The present paper describes a process for designing and applying several techniques based on bioclimatic architecture criteria and on passive cooling and energy conservation principles in order to improve the thermal comfort conditions in an outdoor space location located in the Great Athens area. For that reason, the thermal comfort conditions in 12 different outdoor space points in the experimented location have been calculated using two different thermal comfort bioclimatic indices developed to be used for outdoor spaces. The used indices were the following: (a) “Comfa”, which is based on estimating the energy budget of a person in an outdoor environment and (b) “thermal sensation”, based on the satisfaction or dissatisfaction sensation under the prevailing climatic conditions of the outdoor spaces. Calculations were performed during the summer period and two different scenarios of the constructed space parameters have been considered. The first scenario consists of a conventionally constructed space, while the second one includes various architectural improvements according to the bioclimatic design principles. The two bioclimatic indicators were used for calculating the outdoor thermal comfort conditions in the above-mentioned outdoor space locations for both scenarios and the effect of the bioclimatic design architectural improvements on the human thermal comfort sensation was presented and analysed.  相似文献   

14.
Sekhar SC  Tham KW  Cheong KW 《Indoor air》2003,13(4):315-331
An integrated indoor air quality (IAQ)-energy audit methodology has been developed in this study in Singapore, which provides a rigorous and systematic method of obtaining the status-quo assessment of an 'IAQ signature' in a building. The methodology entails a multi-disciplinary model in obtaining measured data pertaining to different dimensions within the built environment such as the physical, chemical, biological, ventilation, and occupant response characteristics. This paper describes the audit methodology and presents the findings from five air-conditioned office buildings in Singapore. The research has also led to the development of an indoor pollutant standard index (IPSI), which is discussed in this paper. Other performance indicators such as, the ventilation index and the energy index as well as the building symptom index (BSI) are also presented and discussed in the context of an integrated approach to IAQ and energy. Several correlation attempts were made on the various symptoms, indoor air acceptability, thermal comfort, BSI and IPSI, and while BSI values are found to correlate among them as well as with IAQ and THERMAL COMFORT acceptability, no such correlation was observed between BSI and IPSI. This would suggest that the occupants' perception of symptoms experienced as well as environmental acceptability is quite distinct from IAQ acceptability determined from empirical measurements of indoor pollutants, which reinforces the complex nature of IAQ issues.  相似文献   

15.
Numerous techniques have been developed over the years for reducing aerosol exposure in indoor air environments. Among indoor air purifiers of different types, ionic emitters have gained increasing attention and are presently used for removing dust particles, aeroallergens and airborne microorganisms from indoor air. In this study, five ionic air purifiers (two wearable and three stationary) that produce unipolar air ions were evaluated with respect to their ability to reduce aerosol exposure in confined indoor spaces. The concentration decay of respirable particles of different properties was monitored in real time inside the breathing zone of a human manikin, which was placed in a relatively small (2.6 m3) walk-in chamber during the operation of an ionic air purifier in calm air and under mixing air condition. The particle removal efficiency as a function of particle size was determined using the data collected with a size-selective optical particle counter. The removal efficiency of the more powerful of the two wearable ionic purifiers reached about 50% after 15 min and almost 100% after 1.5 h of continuous operation in the chamber under calm air conditions. In the absence of external ventilation, air mixing, especially vigorous one (900 CFM), enhanced the air cleaning effect. Similar results were obtained when the manikin was placed inside a partial enclosure that simulated an aircraft seating configuration. All three stationary ionic air purifiers tested in this study were found capable of reducing the aerosol concentration in a confined indoor space. The most powerful stationary unit demonstrated an extremely high particle removal efficiency that increased sharply to almost 90% within 5-6 min, reaching about 100% within 10-12 min for all particle sizes (0.3-3 microm) tested in the chamber. For the units of the same emission rate, the data suggest that the ion polarity per se (negative vs. positive) does not affect the performance but the ion emission rate does. The effects of particle size (within the tested range) and properties (NaCl, PSL, Pseudomonas fluorescens bacteria) as well as the effects of the manikin's body temperature and its breathing on the ionic purifier performance were either small or insignificant. The data suggest that the unipolar ionic air purifiers are particularly efficient in reducing aerosol exposure in the breathing zone when used inside confined spaces with a relatively high surface-to-volume ratio. PRACTICAL IMPLICATIONS: Ionic air purifiers have become increasingly popular for removing dust particles, aeroallergens and airborne microorganisms from indoor air in various settings. While the indoor air cleaning effect, resulting from unipolar and bipolar ion emission, has been tested by several investigators, there are still controversial claims (favorable and unfavorable) about the performance of commercially available ionic air purifiers. Among the five tested ionic air purifiers (two wearable and three stationary) producing unipolar air ions, the units with a higher ion emission rate provided higher particle removal efficiency. The ion polarity (negative vs. positive), the particle size (0.3-3 microm) and properties (NaCl, PSL, Pseudomonas fluorescens bacteria), as well as the body temperature and breathing did not considerable affected the ionization-driven particle removal. The data suggest that the unipolar ionic air purifiers are particularly efficient in reducing aerosol exposure in the breathing zone when they are used inside confined spaces with a relatively high surface-to-volume ratio (such as automobile cabins, aircraft seating areas, bathrooms, cellular offices, small residential rooms, and animal confinements). Based on our experiments, we proposed that purifiers with a very high ion emission rate be operated in an intermittent mode if used indoors for extended time periods. As the particles migrate to and deposit on indoor surfaces during the operation of ionic air purifiers, some excessive surface contamination may occur, which introduces the need of periodic cleaning these surfaces.  相似文献   

16.
Based on analysis of uncertainty, this paper presents grey system theory to handle the “grey” characteristic of IAQ. Grey comprehensive analysis of indoor air quality reveals that we should pay more attention to the air purification and humidity control in the design and maintenance of HVAC. In order to represent grey characteristic of IAQ system, the educed grey IAQ models can identify the variation intervals of key IAQ model parameters that are lack of directly measurable messages in practical situations. Furthermore, grey assessment is an effective multifactor comprehensive assessment method that can express the integrative influence of contamination indexes on indoor air quality. We can determine the IAQ grade and make comparison according to the grey incidence matrix R.  相似文献   

17.
The thermal environment for air-conditioned offices in subtropical climates is examined from the prospect of maintaining an optimum operative temperature for the occupants. In this study, the optimum neutral temperature is evaluated from 422 occupants’ responses towards the perceiving thermal environment in 61 air-conditioned offices and 186 complaints of thermal discomfort in an air-conditioned office building on an electronic questionnaire, using a semantic differential evaluation scale and a dichotomous assessment scale. In particular, physical parameters for the thermal comfort study were measured by an indoor environmental quality (IEQ) logger, and the operative temperature was correlated with the occupants’ thermal responses. The probability of accepting an operative temperature for the thermal comfort of the occupants was correlated with logistic regression curves; the optimum operative temperature was derived in order to maximize the probability of thermal comfort expressed by the occupants. The results showed that the thermal neutral temperatures for air-conditioned offices in subtropical climates were 23.6 and 21.4 °C in summer and winter, respectively. The preferred thermal environment in Hong Kong should be slightly cool, corresponding to about 1 °C below the neutral temperature, in order to satisfy most of the occupants in the office space.  相似文献   

18.
It is possible to evaluate the energy demand as well as the parameters related to indoor thermal comfort through building energy simulation tools. Since energy demand for heating and cooling is directly affected by the required level of thermal comfort, the investigation of the mutual relationship between thermal comfort and energy demand (and therefore operating costs) is of the foremost importance both to define the benchmarks for energy service contracts and to calibrate the energy labelling according to European Directive 2002/92/CE. The connection between indoor thermal comfort conditions and energy demand for both heating and cooling has been analyzed in this work with reference to a set of validation tests (office buildings) derived from a European draft standard. Once a range of required acceptable indoor operative temperatures had been fixed in accordance with Fanger's theory (e.g. −0.5 < PMV < −0.5), the effective hourly comfort conditions and the energy consumptions were estimated through dynamic simulations. The same approach was then used to quantify the energy demand when the range of acceptable indoor operative temperatures was fixed in accordance with de Dear's adaptive comfort theory.  相似文献   

19.
In this paper, results of a long-term temperature monitoring in a passive solar house, located at the Sede-Boqer Campus of the Ben-Gurion University, in the Negev region of Israel are presented. Local latitude is 30.8°N and the elevation is approximately 480 m above sea level. The climate of the region is characterized by strong daily and seasonal thermal fluctuations, dry air and clear skies with intense solar radiation. The monitored building consists of a two storey, passive solar house and belongs to a student dormitory complex located at the Sede-Boqer Campus. Formulae were developed, based on part of the whole monitoring period, representing the measured daily indoor maximum, average and minimum temperatures. The formulae were then validated against measurements taken independently in different time periods. In managing the building, the main objective in the winter was to bring up the indoor temperature by direct and indirect solar gains while in the summer it was to keep the temperature down. Therefore, analysis of the data and development of predictive formulas of the indoor temperatures were done separately for the winter and for the summer. Measured data of each season were then divided into two sub-periods, the first one used to generate formulas based on measured data (generation) and the second for testing the predictability of the formulas by independent data (validation). In general, a fairly good agreement was verified between onsite measurements and results of the formulae, with regard to daily indoor maximum, average and minimum temperatures. The issue of using outdoor temperatures measured in the adjacent street canyon instead of those registered at the local meteorological site for evaluating the building's cooling demand is also addressed in the paper. The developed formulae were here used for estimating the building's thermal and energy performance in summer, taking into account: (1) solely climatic data from the meteorological station; (2) climatic data from the meteorological station, except for outdoor ambient temperature, which was monitored adjacent to building. Results indicated that the calculation of the building's energy demand for air-conditioning based on temperature data collected at the meteorological station would yield half of the cooling degree-days externally and about two-thirds of that internally, as compared to adopting measured canyon temperatures for such calculations.  相似文献   

20.
The traditional architecture of Kerala, a state in India lying along its southwest coast, is known for its use of natural and passive methods for a comfortable indoor environment. Although there have been attempts to analyze the traditional architecture of Kerala, they were focused only on qualitative approach. An investigation was thus initiated by the authors to understand the passive environment control system of Kerala traditional architecture in providing better thermal comfort, by continuously monitoring thermal comfort parameters of a typical traditional residential building over a period of time. The inferences of the first phase of the investigation carried out during winter and summer seasons, lasting about half of the year have already been published. This paper illustrates the inferences of the second phase of the investigation that is carried out during the rainy season of the year. A comparative analysis with the results of the winter and summer periods is also incorporated. The investigation has revealed that, when the outside ambient temperature is below normal, the building system tries to maintain the indoor air temperature at a higher but comfortable level and when the outside temperature is above normal, the indoor is kept at a lower but comfortable level. It is found that a continuous gentle wind flow is maintained inside the building irrespective of the wind outside. The required level of thermal comfort is achieved by maintaining a balanced level of temperature and relative humidity along with a continuous and controlled airflow inside the building irrespective of seasons.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号