首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Recent reports have shown that nanoscale electronic devices can be used to detect a change in electrical properties when receptor proteins bind to their corresponding antibodies functionalized on the surface of the device, in extracts from as few as ten lysed tumor cells. We hypothesized that nanotube-antibody devices could sensitively and specifically detect entire live cancer cells. We report for the first time a single nanotube field effect transistor array, functionalized with IGF1R-specific and Her2-specific antibodies, which exhibits highly sensitive and selective sensing of live, intact MCF7 and BT474 human breast cancer cells in human blood. Those two cell lines both overexpress IGF1R and Her2, at different levels. Single or small bundle of nanotube devices that were functionalized with IGF1R-specific or Her2-specific antibodies showed 60% decreases in conductivity upon interaction with BT474 or MCF7 breast cancer cells in two μl drops of blood. Control experiments with non-specific antibodies or with MCF10A control breast cells produced a less than 5% decrease in electrical conductivity, illustrating the high sensitivity for whole cell binding by these single nanotube-antibody devices. We postulate that the free energy change due to multiple simultaneous cell-antibody binding events exerted stress along the nanotube surface, decreasing its electrical conductivity due to an increase in band gap. Because the free energy change upon cell-antibody binding, the stress exerted on the nanotube, and the change in conductivity are specific to a specific antigen-antibody interaction; these properties might be used as a fingerprint for the molecular sensing of circulating cancer cells. From optical microscopy observations during sensing, it appears that the binding of a single cell to a single nanotube field effect transistor produced the change in electrical conductivity. Thus we report a nanoscale oncometer with single cell sensitivity with a diameter 1000 times smaller than a cancer cell that functions in a drop of fresh blood.  相似文献   

2.
Zong C  Wu J  Wang C  Ju H  Yan F 《Analytical chemistry》2012,84(5):2410-2415
A sensitive chemiluminescence (CL) imaging immunoassay method for detection of multiple tumor markers with high throughput, easy operation, and low cost was developed. The immunosensor array was prepared by covalently immobilizing capture antibodies on corresponding sensing sites on a silanized disposable glass chip. Gold nanoparticle-based bioconjugates with a high molar ratio of horseradish peroxidase (HRP) to detection antibodies were used for signal amplification. Under a sandwich immunoassay, the CL signals triggered by HRP captured on each sensing cell were collected by a charge-coupled device for simultaneous measurement of biomarkers and combination diagnosis of certain tumors. As a proof of concept, the immunosensor array was applied to detect α-fetoprotein, carcinoma antigen 125, carbohydrate antigen 153, and carcinoembryonic antigen and to screen patients with liver, breast, or ovarian cancers. This method showed wide linear ranges over 5 orders of magnitude and much lower detection limits than previously reported multiplexed immunoassays. The high throughput and acceptable stability, reproducibility, and accuracy showed good applicability of the proposed multiplex CL imaging immunoassay in clinical diagnosis.  相似文献   

3.
There is a need for intraoperative imaging technologies to guide breast‐conserving surgeries and to reduce the high rates of re‐excision for patients in which residual tumor is found at the surgical margins during postoperative pathology analyses. Feasibility studies have shown that utilizing topically applied surface‐enhanced Raman scattering (SERS) nanoparticles (NPs), in conjunction with the ratiometric imaging of targeted versus untargeted NPs, enables the rapid visualization of multiple cell‐surface biomarkers of cancer that are overexpressed at the surfaces of freshly excised breast tissues. In order to reliably and rapidly perform multiplexed Raman‐encoded molecular imaging of large numbers of biomarkers (with five or more NP flavors), an enhanced staining method has been developed in which tissue surfaces are cyclically dipped into an NP‐staining solution and subjected to high‐frequency mechanical vibration. This dipping and mechanical vibration (DMV) method promotes the convection of the SERS NPs at fresh tissue surfaces, which accelerates their binding to their respective biomarker targets. By utilizing a custom‐developed device for automated DMV staining, this study demonstrates the ability to simultaneously image four cell‐surface biomarkers of cancer at the surfaces of fresh human breast tissues with a mixture of five flavors of SERS NPs (four targeted and one untargeted control) topically applied for 5 min and imaged at a spatial resolution of 0.5 mm and a raster‐scanned imaging rate of >5 cm2 min?1.  相似文献   

4.
Immunohistochemistry (IHC) can provide detailed information about protein expression within the cell microenvironment and is one of the most common techniques in biology and medicine due to the broad availability of highly specific antibodies and well-established bioconjugation methods for modification of these antibodies with chromogens and fluorophores. Despite recent advances in this field, it remains challenging to simultaneously achieve high multiplexing, sensitivity, and throughput in single-cell profiling experiments. Here, the combination of two powerful technologies is reported, quantum dot and signal amplification by exchange reaction (QD-SABER), for sensitive and multiplexed imaging of endogenous proteins. Compared to the conventional IHC process using dye-labeled secondary antibodies (which already has a built-in signal amplification mechanism), QD-SABER provides an additional 7.6-fold signal amplification. In addition, the DNA hybridization-based IHC can be rapidly removed to regenerate the sample for subsequent cycles of immunostaining (>10 cycles), greatly expanding the multiplexing capability.  相似文献   

5.
Single-walled carbon nanotubes (CNTs) convert absorbed near infrared (NIR) light into heat. The use of CNTs in the NIR-mediated photothermal ablation of tumor cells is attractive because the penetration of NIR light through normal tissues is optimal and the side effects are minimal. Targeted thermal ablation with minimal collateral damage can be achieved by using CNTs attached to tumor-specific monoclonal antibodies (MAbs). However, the role that the cellular internalization of CNTs plays in the subsequent sensitivity of the target cells to NIR-mediated photothermal ablation remains undefined. To address this issue, we used CNTs covalently coupled to an anti-Her2 or a control MAb and tested their ability to bind, internalize, and photothermally ablate Her2(+) but not Her2(-) breast cancer cell lines. Using flow cytometry, immunofluorescence, and confocal Raman microscopy, we observed the gradual time-dependent receptor-mediated endocytosis of anti-Her2-CNTs whereas a control MAb-CNT conjugate did not bind to the cells. Most importantly, the Her2(+) cells that internalized the MAb-CNTs were more sensitive to NIR-mediated photothermal damage than cells that could bind to, but not internalize the MAb-CNTs. These results suggest that both the targeting and internalization of MAb-CNTs might result in the most effective thermal ablation of tumor cells following their exposure to NIR light.  相似文献   

6.
The development of specific and sensitive immunomagnetic cell separation nanotechnologies is central to enhancing the diagnostic relevance of circulating tumor cells (CTCs) and improving cancer patient outcomes. The limited number of specific biomarkers used to enrich a phenotypically diverse set of CTCs from liquid biopsies has limited CTC yields and purity. The ultra-high molecular weight mucin, mucin16 (MUC16) is shown to physically shield key membrane proteins responsible for activating immune responses against ovarian cancer cells and may interfere with the binding of magnetic nanoparticles to popular immunomagnetic cell capture antigens. MUC16 is expressed in ≈90% of ovarian cancers and is almost universal in High Grade Serous Epithelial Ovarian Cancer. This work demonstrates that cell bound MUC16 is an effective target for rapid immunomagnetic extraction of expressor cells with near quantitative yield, high purity and viability from serum. The results provide a mechanistic insight into the effects of nanoparticle physical properties and immunomagnetic labeling on the efficiency of immunomagnetic cell isolation. The growth of these cells has also been studied after separation, demonstrating that nanoparticle size impacts cell-particle behavior and growth rate. These results present the successful isolation of “masked” CTCs enabling new strategies for the detection of cancer recurrence and select and monitor chemotherapy.  相似文献   

7.
Cloud point extraction (CPE) with inductively coupled plasma mass spectrometry (ICPMS) was applied to the analysis of zinc oxide nanoparticles (ZnO NPs, mean diameter ~40 nm) in water and wastewater samples. Five CPE factors, surfactant (Triton X-114 (TX-114)) concentration, pH, ionic strength, incubation temperature, and incubation time, were investigated and optimized by orthogonal array design (OAD). A three-level OAD, OA(27) (3(13)) matrix was employed in which the effects of the factors and their contributions to the extraction efficiency were quantitatively assessed by the analysis of variance (ANOVA). Based on the analysis, the best extraction efficiency (87.3%) was obtained at 0.25% (w/v) of TX-114, pH = 10, salt content of 15 mM NaCl, incubation temperature of 45 °C, and incubation time of 30 min. The results showed that surfactant concentration, pH, incubation time, and ionic strength exert significant effects on the extraction efficiency. Preconcentration factors of 62 and 220 were obtained with 0.25 and 0.05% (w/v) TX-114, respectively. The relative recoveries of ZnO NPs from different environmental waters were in the range 64-123% at 0.5-100 μg/L spiked levels. The ZnO NPs extracted into the TX-114-rich phase were characterized by transmission electron microscopy (TEM) combined with energy-dispersive X-ray spectroscopy (EDS) and UV-visible spectrometry. Based on the results, no significant changes in size and shape of NPs were observed compared to those in the water before extraction. The extracted ZnO NPs were determined after microwave digestion by ICPMS. A detection limit of 0.05 μg/L was achieved for ZnO NPs. The optimized conditions were successfully applied to the analysis of ZnO NPs in water samples.  相似文献   

8.
Circulating tumor cells (CTCs), though exceedingly rare in the blood, are nonetheless becoming increasingly important in cancer diagnostics. Despite this keen interest and the growing number of potential clinical applications, there has been limited success in developing a CTC isolation platform that simultaneously optimizes recovery rates, purity, and cell compatibility. Herein, a novel tracheal carina‐inspired bifurcated (TRAB) microfilter system is reported, which uses an optimal filter gap size satisfying both 100% theoretical recovery rate and purity, as determined by biomechanical analysis and fluid–structure interaction (FSI) simulations. Biomechanical properties are also used to clearly discriminate between cancer cells and leukocytes, whereby cancer cells are selectively bound to melamine microbeads, which increase the size and stiffness of these cells. Nanoindentation experiments are conducted to measure the stiffness of leukocytes as compared to the microbead‐conjugated cancer cells, with these parameters then being used in FSI analyses to optimize the filter gap size. The simulation results show that given a flow rate of 100 μL min?1, an 8 μm filter gap optimizes the recovery rate and purity. MCF‐7 breast cancer cells with solid microbeads are spiked into 3 mL of whole blood and, by using this flow rate along with the optimized microfilter dimensions, the cell mixture passes through the TRAB filter, which achieves a recovery rate of 93% and purity of 59%. Regarding cell compatibility, it is verified that the isolation procedure does not adversely affect cell viability, thus also confirming that the re‐collected cancer cells can be cultured for up to 8 days. This work demonstrates a CTC isolation technology platform that optimizes high recovery rates and cell purity while also providing a framework for functional cell studies, potentially enabling even more sensitive and specific cancer diagnostics.  相似文献   

9.
To explore the effect of combination therapy of epirubicin (Epi) and melittin (Mel) to cancer cells, calcium carbonate nanoparticles (CCN), as carriers, were developed which were modified with MUC1-Dimer aptamers as targeting agents. Both Epi and Mel were delivered at the same time to cancer cells overexpressing the target of MUC1 aptamer, mucin 1 glycoproteins (MCF7 and C26 cells). CCN were prepared with a water-in-oil emulsion method. Epi and Mel were separately encapsulated in CCN and the nanoparticles were modified with MUC1-Dimer aptamers. In vitro studies, including MTT assay, flow cytometry analysis and fluorescence imaging were applied to investigate the targeting and cell proliferation inhibition capabilities of MUC1-Dimer aptamer-CCN-Mel complex and MUC1-Dimer aptamer-CCN-Epi complex in the target (MCF-7 and C26 cells) and nontarget (HepG2) cells. Also, the function of the developed complexes was analyzed using in vivo tumor growth inhibition. The release of Epi from MUC1-Dimer aptamer-CCN-Epi complex was pH-sensitive. Cellular uptake studies showed more internalization of the MUC1-Dimer aptamer-CCN-Epi complex into MCF-7 and C26 cells (target) compared to HepG2 cells (nontarget). Interestingly, the MUC1-Dimer aptamer-CCN-Mel complex and MUC1-Dimer aptamer-CCN-Epi complex indicated very low toxicity as compared to target cells. Moreover, co-delivery of Epi and Mel using the mixture of MUC1-Dimer aptamer-CCN-Mel complex and MUC1-Dimer aptamer-CCN-Epi complex exhibited strong synergistic cytotoxicity in MCF-7 and C26 cells. Furthermore, the presented complexes had a better function to control tumor growth in vivo compared to free Epi.  相似文献   

10.
Sensitive, single volume detections of multiple diabetes antibodies can provide immunoprofiling and early screening of at‐risk patients. To advance the state‐of‐the‐art suspension assays for diabetes antibodies, porous hydrogel droplets are leveraged in microfluidic serpentine arrays to enhance reagent transport. This spatially multiplexed assay is applied to the detection of antibodies against insulin, glutamic acid decarboxylase, and insulinoma‐associated protein 2. Optimization of assay protocol results in a shortened assay time of 2 h, with better than 20 pg mL Supporting Information detection limits across all three antibodies. Specificity and cross‐reactivity tests show negligible background, nonspecific antibody–antigen, and nonspecific antibody–antibody bindings. Multiplexed detections are able to measure within 15% of target concentrations from low to high ranges. The technique enables quantifications of as little as 8000 molecules in each 500 µm droplet in a single volume, multiplexed assay format, a breakthrough necessary for the adoption of diabetes panels for clinical screening and monitoring in the future.  相似文献   

11.
Up to now, biomedical imaging with ultrasound for observing a cellular tissue structure has been limited to very thinly sliced tissue at very high ultrasonic frequencies, i.e., 1 GHz. In this paper, we present the results of a systematic study to use a 150 to 200 MHz frequency range for thickly sliced biological tissue. A mechanical scanning reflection acoustic microscope (SAM) was used for obtaining horizontal crosssectional images (C-scans) showing cellular structures. In the study, sectioned specimens of human breast cancer and tissues from the small intestine were prepared and examined. Some accessories for biomedical application were integrated into our SAM (Sonix HS-1000 and Olympus UH-3), which operated in pulse-wave and tone-burst wave modes, respectively. We found that the frequency 100 to 200 MHz provides optimal balance between resolution and penetration depth for examining the thickly sliced specimens. The images obtained with the lens focused at different depths revealed cellular structures whose morphology was very similar to that seen in the thinly sectioned specimens with optical and scanning acoustic microscopy. The SAM operation in the pulse-echo mode permits the imaging of tissue structure at the surface, and it also opens up the potential for attenuation imaging representing reflection from the substrate behind the thick specimen. We present such images of breast cancer proving the method?s applicability to overall tumor detection. SAM with a high-frequency tone-burst ultrasonic wave reveals details of tissue structure, and both methods may serve as additional diagnostic tools in a hospital environment.  相似文献   

12.
13.
Breast cancer is caused by the abnormal and rapid growth of breast cells. An early diagnosis can ensure an easier and effective treatment. A mass in the breast is a significant early sign of breast cancer, even though differentiating the cancerous mass's tissue from normal tissue for diagnosis is a difficult task for radiologists. The development of computer-aided detection systems in recent years has led to nondestructive and efficient cancer diagnostic techniques. This paper proposes a comprehensive method to locate the cancerous region in the mammogram image. This method employs image noise reduction, optimal image segmentation based on the convolutional neural network, a grasshopper optimization algorithm, and optimized feature extraction and feature selection based on the grasshopper optimization algorithm, thereby improving precision and decreasing the computational cost. This method was applied to the Mammographic Image Analysis Society Digital Mammogram Database and Digital Database for Screening Mammography breast cancer databases and the simulation results were compared with 10 different state-of-the-art methods to analyze the proposed system's efficiency. Final results showed that the proposed method had 96% Sensitivity, 93% Specificity, 85% PPV, 97% NPV, 92% accuracy, and better efficiency than other traditional methods in terms of Sensitivity, Specificity, PPV, NPV, and Accuracy.  相似文献   

14.
The transport phenomena of laser-produced aerosols prior to analysis by inductively coupled plasma mass spectrometry (ICPMS) were examined. Aerosol particles were visualized over the cross section of a transport tube attached to the outlet of a conventional ablation cell by light scattering using a pulsed laser source. Experiments were carried out under laminar or turbulent in-cell flow conditions applying throughputs of up to 2.0 L/min and reveal the nature of aerosol transportation to strongly depend on both flow rate and carrier gas chosen. For instance, laser ablation (LA) using laminar in-cell flow and helium as aerosol carrier resulted in stationary but inhomogeneous dispersion patterns. In addition, aerosols appear to be separated into two coexisting phases consisting of (i) dispersed particles that accumulate at the boundary layer of several vortex channel flows randomly arranged along the tube axis and (ii) larger fragments moving inside. The occurrence of these fragments was found to affect the accuracy of Si-, Zn-, and Cd-specific ICPMS analyses of aerosols released by LA of silicate glass (SRM NIST610). Accuracy drifts of more than 10% were observed for helium flow rates of >1 L/min, most probably, due to preferential evaporation and diffusion losses of volatile constituents inside the ICP. The utilization of turbulent in-cell flow made the vortex channels collapse and resulted in an almost complete aerosol homogenization. In contrast, LA using argon as aerosol carrier generally yielded a higher degree of dispersion, which was nearly independent of the flow conditions applied. To illustrate the differences among laminar and turbulent in-cell flow, furthermore, the velocity field inside the ablation cell was simulated by computational fluid dynamics.  相似文献   

15.
Breast cancer is marked by large increases in the protein fibers around tumor cells. These fibers increase the mechanical stiffness of the tissue, which has long been used for tumor diagnosis by manual palpation. Recent research in bioengineering has led to the development of novel biomaterials that model the mechanical and architectural properties of the tumor microenvironment and can be used to understand how these cues regulate the growth and spread of breast cancer. Herein, we provide an overview of how the mechanical properties of breast tumor tissues differ from those of normal breast tissue and non-cancerous lesions. We also describe how biomaterial models make it possible to understand how the stiffness and viscosity of the extracellular environment regulate cell migration and breast cancer metastasis. We highlight the need for biomaterial models that allow independent analysis of the individual and different mechanical properties of the tumor microenvironment and that use cells derived from different regions within tumors. These models will guide the development of novel mechano-based therapies against breast cancer metastasis.  相似文献   

16.
Laser ablation (LA) is a powerful analytical technique for solid microsampling. Its coupling with ICPMS has been shown to offer good precision and accuracy for the elemental analysis of glass fragments. Fractionation in LA poses one of the major challenges to using this technique for in situ trace elemental profiling of glass evidence. The aim of this work was to study the effect of elemental fractionation on the forensic application of elemental analysis of glass samples by LA-ICPMS. Two different approaches were used to evaluate the fractionation: fractionation index and U/Th ratios. The resulting fractionation index values indicate low fractionation for the majority of elements evaluated, ranging between 0.8 and 1.2. The U/Th ratio suggests a higher fractionation at the beginning of the ablation process. To evaluate whether fractionation affects the quantification of glass samples by LA-ICPMS, a comparison of LA results with solution ICPMS analysis was conducted. The distribution of particle sizes during the ablation under different conditions and laser systems was also measured to evaluate the fractionation. The standard reference materials NIST 612, 610, and 1831 were analyzed in triplicate by both methods (n = 55) along with a set of 10 casework samples originating from different automobiles.  相似文献   

17.
Quiescent cancer stem cells (CSCs) have long been considered to be a source of tumor initiation. However, identification and isolation of these cells have been hampered by the fact that commonly used fluorescent markers are not sufficiently stable, both chemically and photophysically, to allow tracking over an extended period of time. Here, it is shown that fluorescent nanodiamonds (FNDs) are well suited for this application. Genotoxicity tests of FNDs with comet and micronucleus assays for human fibroblasts and breast cancer cells indicate that the nanoparticles neither cause DNA damage nor impair cell growth. Using AS‐B145‐1R breast cancer cells as the model cell line for CSC, it is found that the FND labeling outperforms 5‐ethynyl‐2′‐deoxyuridine (EdU) and carboxyfluorescein diacetate succinimidyl ester (CFSE) in regards to its long‐term tracking capability (>20 d). Moreover, through a quantification of their stem cell activity by measuring mammosphere‐forming efficiencies (MFEs) and self‐renewal rates, the FND‐positive cells are identified to have an MFE twice as high as that of the FND‐negative cells isolated from the same dissociated mammospheres. Thus, the nanoparticle‐based labeling technique provides an effective new tool for tracking and finding slow‐proliferating/quiescent CSCs in cancer research.  相似文献   

18.
Circulating tumor cells (CTC) are shed in peripheral blood at advanced metastatic stages of solid cancers. Surface-marker-based detection of CTC predicts recurrence and survival in colorectal, breast, and prostate cancer. However, scarcity and variation in size, morphology, expression profile, and antigen exposure impairs reliable detection and characterization of CTC. We have developed a noncontact, label-free microfluidic acoustophoresis method to separate prostate cancer cells from white blood cells (WBC) through forces generated by ultrasonic resonances in microfluidic channels. Implementation of cell prealignment in a temperature-stabilized (±0.5 °C) acoustophoresis microchannel dramatically enhanced the discriminatory capacity and enabled the separation of 5 μm microspheres from 7 μm microspheres with 99% purity. Next, we determined the feasibility of employing label-free microfluidic acoustophoresis to discriminate and divert tumor cells from WBCs using erythrocyte-lysed blood from healthy volunteers spiked with tumor cells from three prostate cancer cell-lines (DU145, PC3, LNCaP). For cells fixed with paraformaldehyde, cancer cell recovery ranged from 93.6% to 97.9% with purity ranging from 97.4% to 98.4%. There was no detectable loss of cell viability or cell proliferation subsequent to the exposure of viable tumor cells to acoustophoresis. For nonfixed, viable cells, tumor cell recovery ranged from 72.5% to 93.9% with purity ranging from 79.6% to 99.7%. These data contribute proof-in-principle that label-free microfluidic acoustophoresis can be used to enrich both viable and fixed cancer cells from WBCs with very high recovery and purity.  相似文献   

19.
We present a method for the noninvasive determination of the size, position, and optical properties (absorption and reduced scattering coefficients) of tumors in the human breast. The tumor is first detected by frequency-domain optical mammography. It is then sized, located, and optically characterized by use of diffusion theory as amodel for the propagation of near-infrared light in breast tissue. Our method assumes that the tumor is a spherical inhomogeneity embedded in an otherwise homogeneous tissue. We report the results obtained on a 55-year-old patient with a papillary cancer in the right breast. We found that the tumor absorbs and scatters near-infrared light more strongly than the surrounding healthytissue. Our method has yielded a tumor diameter of 2.1 ? 0.2cm, which is comparable with the actual size of 1.6 cm, determined after surgery. From the tumor absorption coefficients at two wavelengths (690 and 825 nm), we calculated the total hemoglobin concentration (40 ? 10 muM) and saturation (71 ? 9%) of the tumor. These results can provide the clinical examiner with more detailed information about breast lesions detected by frequency-domain optical mammography, thereby enhancing its potential for specificity.  相似文献   

20.
A laser ablation microanalysis system has been developed that can analyze trace elements with a sensitivity in the ppb range, using a CETAC LSX-200 laser ablation system with a Finnigan Element. This capability has been applied to a set of iron meteorites to demonstrate the laser microprobe's analytical capability for the determination of platinum group elements (PGEs) with a spatial resolution of ~20 μm, comparable to that of dynamic secondary ion mass spectrometry (SIMS). The laser is shown to provide an accurate means of solid sampling for magnetic sector inductively coupled plasma mass spectrometry (ICPMS), allowing the determination of bulk metal composition, chemical zoning within the sample, and depth profiling. Recovery of the chemical zoning in taenite lamellae was achieved for Ru, Rh, and Pd, which was not previously possible using SIMS. The methods presented here show that magnetic sector ICPMS can be successfully coupled to a laser ablation system, providing the advantages of higher sensitivity of the sector instrument, low background count rates (<0.1 counts/s), and flat-topped spectral peaks, while minimizing tradeoff against the speed of data acquisition required to handle the transient signals from the laser ablation system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号