共查询到8条相似文献,搜索用时 5 毫秒
1.
A.-C. Wéra K. Donato Y. Jongen 《Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms》2008,266(10):2122-2124
The interaction of charged particles with living matter needs to be well understood for medical applications. Particularly, it is useful to study how ion beams interact with tissues in terms of damage, dose released and dose rate.One way to evaluate the biological effects induced by an ion beam is by the irradiation of cultured cells at a particle accelerator, where cells can be exposed to different ions at different energies and flux.In this paper, we report the first results concerning the characterization of a broad proton beam obtained with our 2 MV tandem accelerator. For broad beam in vitro cell irradiation, the beam has to be stable over time, uniform over a ∼0.5 cm2 surface, and a dose rate ranging from 0.1 to 10 Gy/min must be achievable. Results concerning the level of achievement of these requirements are presented in this paper for a 1 MeV proton beam. 相似文献
2.
A.-C. Wéra H. Riquier 《Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms》2011,269(24):3120-3124
The study of the interaction of charged particles with living matter is of prime importance to the fields of radiotherapy, radioprotection and space radiobiology. Particle accelerators and their associated equipment are proven to be helpful tools in performing basic science in all these fields. Indeed, they can accelerate virtually any ions to a given energy and flux and let them interact with living matter either in vivo or in vitro. In this context, the University of Namur has developed a broad beam in vitro irradiation station for use in radiobiological experiments. Cells are handled in GLP conditions and can be irradiated at various fluxes with ions ranging from hydrogen to carbon. The station is mounted on a 2 MV tandem accelerator, and the energy range can be set up in the linear energy transfer (LET) ranges that are useful for radiobiological experiments. This paper describes the current status of the hardware that has been developed, and presents results related to its performance in term of dose-rate, energy range and beam uniformity for protons, alpha particles and carbon ions. The results of clonogenic assays of A549 lung adenocarcinoma cells irradiated with protons and alpha particles are also presented and compared with literature. 相似文献
3.
In normal experimental operation, a diagnostic neutral beam (DNB) can produce 6 A of extracted beam current in hydrogen at an energy of 49 keV with a pulse length of 100 ms. Hydrogen and deuterium beams can be produced as well. The diagnostic neutral beam has been added to the diagnostic set so that charge-exchange recombination spectroscopy (CXRS) can be used to acquire ion temperature and rotation. The beam power and beam profile distribution of the DNB injection can be obtained with a thermocouple probe measurement system on the HT-7 superconducting tokamak. The thermocouple probe measurement system with 13 thermocouples crossly distributed on the probe plate was used to measure the temperature rise of each coppery target, so the profile distribution of the ion/neutral beam was obtained by calculation. In this paper, the structure of the probe plate on the DNB for HT-7 tokamak and some measurement results are presented. 相似文献
4.
5.
J. Lao J.M. Nedelec E. Jallot 《Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms》2008,266(10):2412-2417
Ion beam analysis methods were used to characterize the interface of bioactive glasses with surrounding biological fluids. Glass particles in the SiO2-CaO and SiO2-CaO-P2O5 compositions were made by sol-gel processing and soaked in biological fluids for periods up to 4 days. The surface changes were characterized using PIXE-RBS, which are efficient methods for multielemental analysis and accurate trace elements quantification. Elemental maps of major and trace elements were obtained at a micrometer scale and revealed the bone bonding ability of the materials. Glass particles are quickly coated with a thin calcium phosphate-rich layer containing traces of magnesium. After a few days, SiO2-CaO-P2O5 glass particles are entirely changed into calcium phosphates, whereas SiO2-CaO particles exhibit a different behavior: the previously Ca-P enriched periphery has been dissolved and glass particles consist of a silicate network. Calculation of the Ca-P atomic ratios at the glass/biological fluids interface provides us with an explanation for this: an enduring apatitic phase seems to be formed at the periphery of SiO2-CaO-P2O5 glass particles. Presence of phosphorus in the glass matrix thus has an influence on the amplitude and the kinetics of reaction of the bioactivity process. It might result in an improved chemical bond with living tissues. 相似文献
6.
The low-energy muon facility at PSI provides nearly fully polarized positive muons with tunable energies in the ke V range to carry out muon spin rotation(LE-μSR)experiments with nanometer depth resolution on thin films,heterostructures, and near-surface regions. The low-energy muon beam is focused and transported to the sample by electrostatic lenses. In order to achieve a minimum beam spot size at the sample position and to enable the steering of the beam in the horizontal and vertical direction, a special electrostatic device has been implemented close to the sample position. It consists of a cylinder at ground potential followed by four conically shaped electrodes,which can be operated at different electric potential. In LE-μSR experiments, an electric field at the sample along the beam direction can be applied to accelerate/decelerate muons to different energies(0.5–30 keV). Additionally, a horizontal or vertical magnetic field can be superimposed for transverse or longitudinal field μSR experiments. The focusing properties of the conical lens in the presence of these additional electric and magnetic fields have been investigated and optimized by Geant4 simulations. Some experimental tests were also performed and show that the simulation well describes the experimental setup. 相似文献
7.
The low-energy muon facility at PSI provides nearly fully polarized positive muons with tunable energies in the keV range to carry out muon spin rotation (LE-μSR)experiments with nanometer depth resolution on thin films,heterostructures,and near-surface regions.The low-energy muon beam is focused and transported to the sample by electrostatic lenses.In order to achieve a minimum beam spot size at the sample position and to enable the steering of the beam in the horizontal and vertical direction,a special electrostatic device has been implemented close to the sample position.It consists of a cylinder at ground potential followed by four conically shaped electrodes,which can be operated at different electric potential.In LEμSR experiments,an electric field at the sample along the beam direction can be applied to accelerate/decelerate muons to different energies (0.5-30 keV).Additionally,a horizontal or vertical magnetic field can be superimposed for transverse or longitudinal field μSR experiments.The focusing properties of the conical lens in the presence of these additional electric and magnetic fields have been investigated and optimized by Geant4 simulations.Some experimental tests were also performed and show that the simulation well describes the experimental setup. 相似文献
8.
《核技术(英文版)》2016,(4):86-92
The applications of carbon ion beam in tumor therapy have attracted more attention in recent years.Monte Carlo simulation is an important approach to obtain accurate radiotherapy parameters. In this work, a400 Me V/u carbon ion beam incident on water phantom was simulated with Gate/Geant4 tools. In methods, the authors set up a carbon ion beam source according to the experiment parameters of Haettner, defined the geometries and materials, set up the physics processes, and designed the means of information collection. In results,the authors obtained the longitudinal dose distribution, the lateral dose distribution, and the relative uncertainty of dose. The dose contributions of all kinds of fragments were calculated detailedly and compared with the Francis results. This work is helpful for people's understanding of the dose distributions produced by carbon ion beam and fragments in water. The simulation method is also significative for radiotherapy treatment planning of carbon ion beam, and it is easy to extend. For obtaining a special result, we may change the particle energy, particle type,target material, target geometry, physics process, detector,etc. 相似文献