首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Gas chromatography (GC)/surface ionization organic mass spectrometry (SIOMS) has been found to give much higher sensitivity for measurements of phencyclidine (PCP) than the conventional GC/electron impact (EI)-mass spectrometry (MS). Thus, we have established a detailed procedure for measurements of PCP in body fluids by both mass chromatography and selected-ion monitoring (SIM) of SIOMS using pethidine as an internal standard (IS). Good linearity was found in the range of 0.25-10 ng/mL of whole blood or urine, when measured by mass chromatography, and in the range of 0.025-1.0 ng/mL of whole blood by SIM. The recoveries of PCP and IS spiked to whole blood were 106 +/- 17% at 1 ng/mL and 113 +/- 11% at 5 ng/mL; that of IS was 97.8 +/- 10.4% at 5 ng/mL. The detection limits (signal-to-noise ratio = 3) were estimated to be 0.05 ng/mL of whole blood or urine by mass chromatography and 0.01 ng/mL of whole blood by SIM. The coefficients of intraday and interday variations were not greater than 10.3%. We could detect PCP from rat whole blood 2 h after subcutaneous injection of PCP (1 mg/kg) by mass chromatography. The mean PCP concentration in rat blood was 47.7 +/- 6.2 ng/mL (mean +/- SD, n = 4).  相似文献   

2.
粮谷中嗪草酮残留量的气相色谱和气相色谱-质谱分析   总被引:1,自引:0,他引:1  
粮谷中嗪草酮残留用苯提取,提取液经浓缩、定容后直接用配有氮磷检测器的气相色谱仪测定,并用气相色谱-质谱(选择离子监测)进行确证。以HP-1大口径毛细管柱和HP-1毛细管柱为分离柱,选择出合适的色谱条件,嗪草酮的分离效果良好。本方法对大米样品的测定下限为0.05mg/kg;添加浓度为0.05mg/kg~1.0mg/kg的嗪草酮,回收率为80%以上;相对标准偏差小于9.5%。样品前处理采用了微量化学法(MiccM)技术,质谱(选择离子监测)确证的监测离子选M/Z103、144、182、198、214amu。  相似文献   

3.
Adhesives made from natural substances such as resins, tars, and waxes are found during excavations on archaeological sites dating back to prehistoric periods. Until now, their analysis was mainly performed by gas chromatography, possibly coupled to mass spectrometry, after extraction, purification, and derivatization of the samples. To minimize sampling and sample preparation of ancient organic remains, which are often preserved in tiny amounts, we have directly analyzed archaeological samples from Bronze and Iron Age periods by direct inlet electron ionization mass spectrometry. A series of contemporary natural and synthetic substances, including pine and pistacia resins, birch bark tar, beeswax, and plant oils, possibly used for adhesive fabrication during ancient times, was also investigated with the same technique as reference materials. Despite the complexity of their chemical composition, pine resin and birch bark tar were clearly identified in archaeological samples. Furthermore, mass spectrometry has been shown to be efficient for the identification of glues made of a mixture of beeswax, presenting a series of mass spectral peaks assigned to long-chain esters, and birch bark tar, whose mass spectrum presents characteristic peaks of lupane compounds. The intentional mixing of birch bark tar and beeswax during prehistory is reported here for the first time.  相似文献   

4.
Gas chromatography/mass spectrometry (GC/MS) is often used for detection and measurement of cocaine metabolites in biological specimens. However, cocaine N-oxide, a recently identified metabolite of cocaine, is thermally degraded when introduced into a GC/MS. The major degradation products are cocaine and norcocaine. When cocaine N-oxide was measured in rat plasma using liquid chromatography in combination with electrospray ionization-mass spectrometry (LC/ESI-MS), the cocaine N-oxide concentrations in the rat plasma were reported to be as high as 30% of the cocaine concentrations. However, in our study involving LC/ESI-MS/MS analysis of plasma collected from human subjects following administration of oral cocaine, we determined that the concentrations of cocaine N-oxide relative to the cocaine concentrations never exceeded 3%. This suggests that determination of cocaine concentration in human plasma by GC/MS analysis will not significantly distort the actual cocaine concentrations due to thermal conversion of cocaine N-oxide to cocaine. In the work reported here, we compared results obtained using GC/MS, LC/ESI-MS/MS, and liquid chromatography/atmospheric pressure chemical ionization-tandem mass spectrometry (LC/APCI-MS/MS) to determine thermal degradation of cocaine N-oxide. LC/ ESI-MS/MS was selected to determine cocaine, benzoylecgonine, and cocaine N-oxide, and LC/APCI-MS/MS was selected to determine ecgonine methyl ester and norcocaine in plasma collected from three human subjects participating in a clinical study. The resulting time course data provide additional information into kinetic interrelationships between cocaine N-oxidation and cocaine hydrolysis.  相似文献   

5.
Polycyclic aromatic sulfur heterocycles (PASH) are sulfur analogues of polycyclic aromatic hydrocarbons (PAH). Alkylated PAH attract much attention as carcinogens, mutagens, and as diagnostics for environmental forensics. PASH, in contrast, are mostly ignored in the same studies due to the conspicuous absence of gas chromatography/mass spectrometry (GC/MS) retention times and fragmentation patterns. To obtain these data, eight coal tar and crude oils were analyzed by automated sequential GC-GC. Sample components separated based on their interactions with two different stationary phases. Newly developed algorithms deconvolved combinatorially selected ions to identify and quantify PASH in these samples. Simultaneous detection by MS and pulsed flame photometric detectors (PFPD) provided additional selectivity to differentiate PASH from PAH when coelution occurred. A comprehensive library of spectra and retention indices is reported for the C(1)-C(4) two-, three-, and four-ring PASH. Results demonstrate the importance of using multiple fragmentation patterns per homologue (MFPPH) compared to selected ion monitoring (SIM) or extraction (SIE) to identify isomers. Since SIM/SIE analyses dramatically overestimate homologue concentrations, MFPPH should be used to correctly quantify PASH for bioavailability, weathering, and liability studies.  相似文献   

6.
猪肉中二溴磷残留量的气相色谱和气相色谱/质谱分析   总被引:1,自引:0,他引:1  
试样经盐酸酸化,用正己烷提取残留的二溴磷。提取液在-20℃冷冻2小时凝固析出脂肪,净化液经浓缩定容后,用配有电子俘获检测器的气相色谱测定(GC-ECD),外标定量,并用气相色谱—质谱(选择离子监测)(GC/MS(SIM))进行确证。以HP-5大口径毛细管柱和HP-5MS毛细管柱为分离柱,选择出合适的色谱条件,二溴磷的分离效果良好。本方法对猪肉样品的测定低限为0.05mg/kg;添加浓度为0.05mg/kg~1.00mg/kg时,回收率为89%以上;相对标准偏差小于5.0%;标准进样量在0.1~10.0ng范围内,线性关系良好,r=0.9995。样品前处理采用了微量化学法(MiccM)技术,质谱(选择离子监测)确证的监测离子选m/z 301、185、109amu。  相似文献   

7.
水果中三唑酮残留用丙酮提取,经液—液分配净化,用气相色谱—电子捕获检测器(GC—ECD)测定,并用气相色谱—质谱(离子选择监测)[Gc/MS(SIM))进行确证。以HP-5大口径毛细管柱和HP-5MS毛细管柱为分离柱,选择出合适的色谱条件,三唑酮的分离效果良好。本方法对苹果样品的测定低限为0.05mg/kg,添加浓度为0.05~1.0mg/kg的三唑酮,回收率为96%以上,变异系数小于4.0%。  相似文献   

8.
A simple method for direct coupling of gas chromatography (GC) with electrospray ionization mass spectrometry (ESI/MS) has been developed. The outlet of the GC capillary column was placed between the ESI needle and the atmospheric pressure ionization (API) source of a mass spectrometer. The ionization occurs via dissolution of neutral compounds into the charged ESI droplet followed by ion evaporation or via a gas-phase proton transfer reaction between a protonated solvent molecule and an analyte. The mass spectra of organic volatile compounds showed abundant protonated molecules with little fragmentation, being very similar to those produced by normal liquid ESI. The quantitative performance of the system was evaluated by determining the limit of detection (LOD), linearity ( r (2)), and repeatability (RSD). The GC-ESI/MS method was shown to be stable, providing high sensitivity and good quantitative performance.  相似文献   

9.
建立了化妆品中5种硝基麝香含量的气相色谱-质谱联用检测方法。采用丙酮/正己烷混合液超声提取化妆品中的硝基麝香,提取液经过浓缩,由气相色谱-质谱联用仪检测,以氘代二甲苯麝香内标法定量。该方法对化妆品中5种硝基麝香的加标回收率在85.21%~110.2%之间,相对标准偏差(RSD)不大于7.15%,在50μg/L~5000μg/L范围内呈现良好的线性关系,灵敏度高,最低检测限分别达到20~50μg/kg;选择性好,能有效消除复杂基体干扰。可用于常见化妆品中硝基麝香类化合物含量的检测。  相似文献   

10.
Electrospray ionization mass spectrometry coupled to multiple reaction monitoring (ESI-MS/MRM) has been applied for the first time to analyze enzyme inhibitor kinetics. Specifically, a known competitive inhibitor, guanosine 5'-monophosphate (GMP), and a synthetic, transition-state analogue inhibitor, guanosine 5'-[1D-(1,3,4/2)-5-methyl-5-cyclohexene-1,2,3,4-tetrol 1-diphosphate] (1) have been characterized against recombinant fucosyltransferase (Fuc-T) V using ESI-MS/MRM. Dixon analysis with GMP yielded a signature plot for competitive inhibition. Nonlinear regression analysis gave a Ki of 211.8+/-24.7 microM. The conventional analysis using GDP-[U-14C]-Fuc yielded a similar Ki value of 235.6+/-59.4 microM, confirming the validity of the MS-based method. The synthetic inhibitor 1 showed potent competitive inhibition with a Ki of 25.6+/-2.8 microM. Although 1 possesses a chemically reactive allyl phosphate group, ESI-MS/MRM showed that there was no reduction in the concentration of 1 and no production of a predicted metabolite GDP during the assay. MS/MS also confirmed the absence of a possible pseudo-trisaccharide product. The results clearly show that 1 is neither a slow-reacting donor nor does it act as a suicide-type inhibitor toward Fuc-T V. ESI-MS/MRM is therefore a powerful tool for the kinetic characterization of enzyme inhibitors, providing complete disclosure of the mechanism of action of 1 as an inhibitor.  相似文献   

11.
A miniaturized two-electrode electrochemical (EC) cell was developed and was coupled on-line with an electrospray ionization Fourier transform ion cyclotron resonance mass spectrometer (ESI-FTICR MS). Electrochemistry on-line with mass spectrometry, EC/ESI-FTICR MS, of triphenylamine (TPA), which undergoes one-electron oxidation to form a radical cation (TPA*+), demonstrates a significant sensitivity enhancement compared to ESI-FTICR MS. The on-line EC cell configuration with a stainless steel ES needle as the working electrode produces the highest sensitivity in EC/ESI-MS. The results provide evidence that, during the ES ionization, electrolytic reactions occur mainly in the ES tip region, as previously predicted. The results demonstrate that ESI-MS signal suppression by tetrabutylammonium perchlorate electrolyte, which can be a problem, is minimized in EC/ESI-MS. TPA*+ dimer tetraphenylbenzidine (TPB) can be detected by EC/ESI-MS, together with TPA*+, as TPB*+ and TPB2+. The high mass resolving power of FTICR MS was exploited to identify TPB2+ dication in the presence of [TPA*+ - H*]+ ions of the same m/z, from their respective isotopic distributions. The dimer dication TPB2+ can be detected only in EC/ESI-MS.  相似文献   

12.
New developments in biochemical mass spectrometry: electrospray ionization   总被引:32,自引:0,他引:32  
The principles, development, and recent application of electrospray ionization-mass spectrometry (ESI-MS) to biological compounds are reviewed. ESI-MS methods now allow determination of accurate molecular weights for proteins extending to over 50,000, and in some cases well over 100,000. Similar capabilities are being developed for oligonucleotides. The instrumentation used for ESI-MS is briefly described and it is shown that, although ionization efficiency appears to be uniformly high, detector sensitivity may be directly correlated with molecular weight. The use of tandem mass spectrometry (e.g., MS/MS) for extending collision-induced dissociation (CID) methods to the structural studies of large molecules is described. For example, effective CID of various albumin species (molecular weight approximately 66,000) can be obtained, far larger than obtainable for singly charged molecular ions. The combination of capillary electrophoresis, in both free solution zone electrophoresis and isotachophoresis formats, as well as microcolumn liquid chromatography with ESI-MS, provides the capability for on-line separation and analysis of subpicomole quantities of proteins. These and other new developments related to ESI-MS are illustrated by a range of examples. Fundamental considerations suggest even more impressive developments may be anticipated related to detection sensitivity and methods for obtaining structural information.  相似文献   

13.
A single multiresidue method was developed to determine 109 priority organic compounds included in the 76/464/EEC Council Directive on Pollution of the European Union. Such Directive includes 132 priority pollutants with a broad spectrum of polarities to be analyzed in drinking and surface waters, with the aim to protect water quality. From this list, the compounds analyzed included benzidines, chloroanilines, chloronitrobenzenes, chloronitrotoluenes, chlorophenols, chloronitrotoluidines, PAHs, PCBs, pesticides, phenylurea, and triazine herbicides. The method was developed in four steps. First, automated off-line solid-phase extraction using polymeric sorbent Oasis 60 mg cartridges was optimized to trap 109 compounds. Second, gas chromatography coupled to mass spectrometry with electron impact ionization (GC/EI/MS) was used in selected ion monitoring (SIM) mode for tentative identification of target analytes. Third, GC/EI/MS under full scan conditions was used for spectrum identification and analyte confirmation. Last, quantification was performed from SIM chromatogram using surrogates and internal standard. This method offered excellent sensitivity and selectivity, and the preconcentration of 200 mL permitted the achievement of limits of detection at the low nanogram/liter level and recoveries between 70 and 120%. Such methodology was applied to determine 109 organic compounds in French surface waters, and several pollutants were detected at levels from ppt to ppb. This multiresidue method developed was highly reproducible and robust and permitted a high sample throughput.  相似文献   

14.
In this study, we report a novel procedure for fabricating internally tapered capillary columns suitable for the coupling of capillary electrochromatography (CEC) to electrospray mass spectrometry (ESI-MS). The internal tapers were prepared by slowly heating the capillary end in a methane/O2 flame. Due to continuous self-shrinking of the inner channel of the capillary, the inside diameter of the opening was reduced to 7-10 microm. The procedure is easy to handle, with no requirement for expensive equipment as well as elimination of problematic grinding of the tip. Several advantages of these new internal tapers, as compared to using externally tapered columns, are described. First, the problems of poor durability and tip breakage associated with external tapering were successfully overcome with the internal taper. A comparison of the online CEC/ESI-MS between external versus internal tapers showed that the latter provides enhanced electrospray stability, resulting in significantly lower short-term noise and very short-term noise values. In turn, the more rugged design of internal tapers allows performing CEC/MS utilizing a harsh polar organic mobile phase, which was not previously successful using an external taper due to higher operating current and electrospray arcing. Next, data on the reproducibility of the internally tapered CEC/MS column using warfarin and beta-blockers as model analytes are presented. For example, when comparing the reproducibility for separation of warfarin under reversed-phase conditions, the internal taper demonstrated superior intraday % RSD (1.6-3.4) as compared to the external taper intraday % RSD (5-6). Last, the applicability of performing quantitative CEC/MS with internally tapered capillaries is demonstrated for simultaneous enantioseparation of beta-blockers. Impressive quantitative results include good linearity of calibration curves (e.g., R2 = 0.9940-0.9988) and limit of detection as low as 30 nM. The sensitive detection of a minor impurity of one enantiomer at the 0.1% level in a major chiral entity buttresses the suitability of compliance with FDA guidelines.  相似文献   

15.
Analysis of C37 alkenone mixtures by gas chromatography (GC) with flame ionization detection (FID) and GC coupled to mass spectrometry (GC/MS) in the chemical ionization mode (CI) shows that the later is useful for paleotemperature estimation when ammonia is used as reagent gas. Conversely, the use of isobutane gives rise to Uk'37 readings that are dependent on the amount of C37 alkenones introduced in the system, being unreliable for paleoclimatic studies. However, ammonia CI GC/MS may produce Uk'37 measurements that deviate from those obtained by GC-FID, the method calibrated for temperature estimation from algal cultures and marine sedimentary data. The differences result from changes in relative sensitivity between the di- and triunsaturated alkenones and depend on the instrument used and operational conditions. This problem is solved in the present study by determination of the response factor linear equations for each alkenone and their average relative sensitivity (R) using mixtures of known composition. These parameters allow the transformation of the GC/MS readings into the GC-FID equivalents using the following equation: UG = R x UM/(1 - UM(1 - R)). Examples of the suitability of this approach are given.  相似文献   

16.
A fully automated high-throughput liquid-liquid extraction (LLE) methodology has been developed for preparation of biological samples using a 96-well LLE plate and a 96-channel robotic liquid handling workstation. The 96-well LLE plate is made of a 96-well filter plate filled with inert diatomaceous earth particles, allowing continuous and efficient extraction of analytes between the aqueous biological sample and the organic extraction solvent. Two carboxylic acid-based protease inhibitor compounds with high and low levels of plasma protein binding were chosen for the development and application of the automated methodology. The LLE extracts of the plasma samples of the two compounds were analyzed by high-performance liquid chromatography with electrospray (ESI) tandem mass spectrometry (LC-MS/MS). The LC-MS/MS method was developed using a rapid gradient LC separation, followed by sample introduction through an ionspray interface in the negative ion mode and tandem mass spectrometric detection with selected reaction monitoring. In the optimized LLE method, a formate buffer solution was first loaded into a 96-well filter plate packed with inert diatomaceous earth material. Then crude plasma samples and a water-immiscible organic solvent, methyl ethyl ketone, were sequentially added to the LLE plate so that LLE would occur in the interface between the two liquid phases on the surface of individual particles in each well. The organic eluate containing extracted analytes was evaporated and reconstituted for LC-MS/MS analysis. This fully automated LLE methodology avoids several disjointed steps involved in a manual or semiautomated LLE method, leading to significantly reduced sample preparation time, increased sample throughput, and clean sample extracts for improved ESI-MS/MS detection. The automated LLE methodology is universal and can be employed for sample preparation of other biological fluids. The complete bioanalytical method, based on the automated LLE and fast gradient LC-MS/MS, was validated and successfully applied to the quantitative analysis of protease inhibitors in rat plasma.  相似文献   

17.
We describe a method, based on pressure-assisted capillary electrophoresis coupled to electrospray ionization mass spectrometry (PACE/ESI-MS), that allows the simultaneous and quantitative analysis of multivalent anions, such as citrate isomers, nucleotides, nicotinamide-adenine dinucleotides, and flavin adenine dinucleotide, and coenzyme A (CoA) compounds. Key to the analysis was using a noncharged polymer, poly(dimethylsiloxane), coated to the inner surface of the capillary to prevent anionic species from adsorbing onto the capillary wall. It was also necessary to drive a constant liquid flow toward the MS by applying air pressure to the inlet capillary during electrophoresis to maintain a conductive liquid junction between the capillary and the electrospray needle. Although theoretical plates were inferior to those obtained by CE/ESI-MS using a cationic polymer-coated capillary, the PACE/ESI-MS method improved reproducibility and sensitivity of these anions. Eighteen anions were separated by PACE and selectively detected by a quadrupole mass spectrometer with a sheath-flow electrospray ionization interface. The relative standard deviations (n = 6) of the method were better than 0.6% for migration times and between 1.4% and 6.2% for peak areas. The detection limits for these species were between 0.4 and 3.7 micromol/L with pressure injection of 50 mbar for 30 s (30 nL), that is, mass detection limits calculated in the range from 12 to 110 fmol at a signal-to-noise ratio of 3. The utility of the method was demonstrated by analysis of citrate isomers, nucleotides, dinucleotides, and CoA compounds extracted from Bacillus subtilis cells.  相似文献   

18.
Measurement of the proliferation of lymphocytes and other high-turnover cell populations in vivo can be accomplished through the incorporation of an isotopically labeled DNA precursor into actively dividing cells and the subsequent determination of the isotope enrichment in the isolated genomic DNA from selected cell populations. Two published gas chromatography/mass spectrometry (GC/MS) methods were successfully modified by our laboratory whereby a postinjection methylation reaction, rather than silylation or acetylation, was used to form a volatile derivative of deoxyadenosine (dA). We also developed a second robust microcapillary liquid chromatography-electrospray ionization (microLC-ESI)/MS method that is faster and more sensitive than the GC/MS method and does not require sample derivatization. Following administration of [6,6-(2)H(2)]-glucose to human immunodeficiency virus-infected patients, peripheral blood was drawn; cells were obtained by lymphapheresis and fractionated. DNA was isolated from the desired cell subtypes and enzymatically hydrolyzed to the free deoxyribonucleosides. The digest was analyzed using both capillary GC/MS and microLC/ESI-MS to measure the levels of the dA and [(2)H(2)]-dA or their reaction products. Sample enrichments were calculated by comparison to standard curves prepared from dA and [(2)H(2)]-dA. The microLC/ESI-MS method required fewer cells, less sample preparation, shorter analysis times, and a single calibration curve. Overall, the microLC/ESI-MS method is superior to the GC/MS method in terms of precision and accuracy, while providing a 4-fold increase in sensitivity (from 20 pmol at 0.2% [(2)H(2)]-dA enrichment to 5 pmol at 0.1% [(2)H(2)]-dA enrichment).  相似文献   

19.
The application of electrospray ionization mass spectrometry (ESI-MS) to trace-fiber color analysis is explored using acidic dyes commonly employed to color nylon-based fibers, as well as extracts from dyed nylon fibers. Qualitative information about constituent dyes and quantitative information about the relative amounts of those dyes present on a single fiber become readily available using this technique. Sample requirements for establishing the color identity of different samples (i.e., comparative trace-fiber analysis) are shown to be submillimeter. Absolute verification of dye mixture identity (beyond the comparison of molecular weights derived from ESI-MS) can be obtained by expanding the technique to include tandem mass spectrometry (ESI-MS/MS). For dyes of unknown origin, the ESI-MS/MS analyses may offer insights into the chemical structure of the compound-information not available from chromatographic techniques alone. This research demonstrates that ESI-MS is viable as a sensitive technique for distinguishing dye constituents extracted from a minute amount of trace-fiber evidence. A protocol is suggested to establish/refute the proposition that two fibers--one of which is available in minute quantity only--are of the same origin.  相似文献   

20.
The advantages of gas chromatography/mass spectrometry (GC/MS) selected-ion monitoring (SIM) in the mass profile (MP) mode at medium mass resolving power were investigated for analyses requiring detection of low-picogram quantities of analytes in complex mixtures. The mass profile monitoring provides a certainty at least 10 times greater than that achieved by conventional GC/MS-SIM in the peak-top monitoring mode, and it can be operated at lower mass resolving power to compensate for the loss of sensitivity in the MP mode. The examination of mass profile peak shape, central mass shift, and sequential changes during GC elution not only reveals the presence of interfering compounds but also results in accurate mass measurement for those interferences. The latter feature takes the MP mode beyond the target mass analysis that GC/MS-SIM was originally designed for. This additional dimension of information is particularly useful for those complex and incompletely characterized matrices that are frequently encountered in environmental and biological sample analyses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号