首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Bioaerosol concentrations in residential buildings located in the Northeastern US have not been widely studied. Here, in 2011-2015, we studied the presence and seasonal variability of culturable fungi and bacteria in three multi-family apartment buildings and correlated the bioaerosol concentrations with building ventilation system types and environmental parameters. A total of 409 indoor and 86 outdoor samples were taken. Eighty-five percent of investigated apartments had indoor-outdoor (I/O) ratios of culturable fungi below 1, suggesting minimal indoor sources of fungi. In contrast, 56% of the apartments had I/O ratios for culturable bacteria above 1, indicating the prominence of indoor sources of bacteria. Culturable fungi I/O ratios in apartments serviced by central heating, ventilation, and air-conditioning (HVAC) system were lower than those in apartments with window AC. The type of ventilation system did not have a significant effect on the presence of indoor culturable bacteria. A significant positive association was determined between indoor dew point (DP) levels and indoor culturable fungi (P < .001) and bacteria (P < .001), regardless of ventilation type. Also, residents in apartments with central HVAC did not experience extreme DP values. We conclude that building ventilation systems, seasonality, and indoor sources are major factors affecting indoor bioaerosol levels in residential buildings.  相似文献   

2.
More and more studies reported that there were insufficient ventilation and excessive CO_2 concentration in air-conditioned residential buildings, but few solutions were provided. This study investigates the overnight evolution of CO_2 concentration in air-conditioned residential buildings and then focuses mainly on the evaluation of three ventilation strategies, including overnight natural ventilation, short-term mechanical ventilation and short-term natural ventilation. On-site measurements were conducted in a typical residential bedroom in Hong Kong in September. The indoor and outdoor CO_2 concentration, air temperature and relative humidity as well as the outdoor wind speed during the measurements were analysed. Ventilation rates were calculated based on the time series of CO_2 concentration. This study confirms that additional ventilation is usually needed in air-conditioned residential buildings. Overnight natural ventilation with even a small opening is associated with excessive energy consumption and deteriorated indoor thermal environment. Short-term natural ventilation strategies are inefficient and uncontrollable. Compared to the best short-term natural ventilation strategy, a reasonably designed short-term mechanical ventilation strategy requires only a 41% of ventilation period to complete one full replacement of indoor air and to reach a lower indoor CO_2 concentration. Nighttime case studies and a theoretical analysis suggest that a few several-minute mechanical ventilation periods could potentially maintain an acceptable indoor air quality for a normal sleeping period of 8 h.  相似文献   

3.
Asian dust storms (ADS) originating from the arid deserts of Mongolia and China are a well-known springtime meteorological phenomenon throughout East Asia. The ventilation systems in office utilize air from outside and therefore it is necessary to understand how these dust storms affect the concentrations of PM2.5 and PM10 in both the indoor and outdoor air. We measured dust storm pollution particles in an office building using a direct-reading instrument (PC-2 Quartz Crystal Microbalance, QCM) that measured particle size and concentration every 10 min for 1 h, three times a day. A three-fold increase in the concentrations of PM2.5 and PM10 in the indoor and outdoor air was recorded during the dust storms. After adjusting for other covariates, autoregression models indicated that PM2.5 and PM10 in the indoor air increased significantly (21.7 μg/m3 and 23.0 μg/m3 respectively) during dust storms. The ventilation systems in high-rise buildings utilize air from outside and therefore the indoor concentrations of fine and coarse particles in the air inside the buildings are significantly affected by outside air pollutants, especially during dust storms.  相似文献   

4.
Particle count-based size distribution and PM(2.5) mass were monitored inside and outside an elementary school in Salt Lake City (UT, USA) during the winter atmospheric inversion season. The site is influenced by urban traffic and the airshed is subject to periods of high PM(2.5) concentration that is mainly submicron ammonium and nitrate. The school building has mechanical ventilation with filtration and variable-volume makeup air. Comparison of the indoor and outdoor particle size distribution on the five cleanest and five most polluted school days during the study showed that the ambient submicron particulate matter (PM) penetrated the building, but indoor concentrations were about one-eighth of outdoor levels. The indoor:outdoor PM(2.5) mass ratio averaged 0.12 and particle number ratio for sizes smaller than 1 microm averaged 0.13. The indoor submicron particle count and indoor PM(2.5) mass increased slightly during pollution episodes but remained well below outdoor levels. When the building was occupied the indoor coarse particle count was much higher than ambient levels. These results contribute to understanding the relationship between ambient monitoring station data and the actual human exposure inside institutional buildings. The study confirms that staying inside a mechanically ventilated building reduces exposure to outdoor submicron particles. PRACTICAL IMPLICATIONS: This study supports the premise that remaining inside buildings during particulate matter (PM) pollution episodes reduces exposure to submicron PM. New data on a mechanically ventilated institutional building supplements similar studies made in residences.  相似文献   

5.
M. Zaatari  J. Siegel 《Indoor air》2014,24(4):350-361
Particles in retail environments can have consequences for the occupational exposures of retail workers and customers, as well as the energy costs associated with ventilation and filtration. Little is known about particle characteristics in retail environments. We measured indoor and outdoor mass concentrations of PM10 and PM2.5, number concentrations of submicron particles (0.02–1 μm), size‐resolved 0.3–10 μm particles, as well as ventilation rates in 14 retail stores during 24 site visits in Pennsylvania and Texas. Overall, the results were generally suggestive of relatively clean environments when compared to investigations of other building types and ambient/occupational regulatory limits. PM10 and PM2.5 concentrations (mean ± s.d.) were 20 ± 14 and 11 ± 10 μg/m3, respectively, with indoor‐to‐outdoor ratios of 1.0 ± 0.7 and 0.88 ± 1.0. Mean submicron particle concentrations were 7220 ± 7500 particles/cm3 with an indoor‐to‐outdoor ratio of 1.18 ± 1.30. The median contribution to PM10 and PM2.5 concentrations from indoor sources (vs. outdoors) was 83% and 53%, respectively. There were no significant correlations between measured ventilation rates and particle concentrations of any size. When examining options to lower PM2.5 concentrations below regulatory limits, the required changes to ventilation and filtration efficiency were site specific and depended on the indoor and outdoor concentration, emission rate, and infiltration level.  相似文献   

6.
To evaluate the separate impacts on human health and establish effective control strategies, it is crucial to estimate the contribution of outdoor infiltration and indoor emission to indoor PM2.5 in buildings. This study used an algorithm to automatically estimate the long-term time-resolved indoor PM2.5 of outdoor and indoor origin in real apartments with natural ventilation. The inputs for the algorithm were only the time-resolved indoor/outdoor PM2.5 concentrations and occupants’ window actions, which were easily obtained from the low-cost sensors. This study first applied the algorithm in an apartment in Tianjin, China. The indoor/outdoor contribution to the gross indoor exposure and time-resolved infiltration factor were automatically estimated using the algorithm. The influence of outdoor PM2.5 data source and algorithm parameters on the estimated results was analyzed. The algorithm was then applied in four other apartments located in Chongqing, Shenyang, Xi'an, and Urumqi to further demonstrate its feasibility. The results provided indirect evidence, such as the plausible explanations for seasonal and spatial variation, to partially support the success of the algorithm used in real apartments. Through the analysis, this study also identified several further development directions to facilitate the practical applications of the algorithm, such as robust long-term outdoor PM2.5 monitoring using low-cost light-scattering sensors.  相似文献   

7.
Ward M  Siegel JA  Corsi RL 《Indoor air》2005,15(2):127-134
Stand-alone air cleaners may be efficient for rapid removal of indoor fine particles and have potential use for shelter-in-place (SIP) strategies following acts of bioterrorism. A screening model was employed to ascertain the potential significance of size-resolved particle (0.1-2 microm) removal using portable high efficiency particle arresting (HEPA) air cleaners in residential buildings following an outdoor release of particles. The number of stand-alone air cleaners, air exchange rate, volumetric flow rate through the heating, ventilating and air-conditioning (HVAC) system, and size-resolved particle removal efficiency in the HVAC filter were varied. The effectiveness of air cleaners for SIP was evaluated in terms of the outdoor and the indoor particle concentration with air cleaner(s) relative to the indoor concentration without air cleaners. Through transient and steady-state analysis of the model it was determined that one to three portable HEPA air cleaners can be effective for SIP following outdoor bioaerosol releases, with maximum reductions in particle concentrations as high as 90% relative to conditions in which an air cleaner is not employed. The relative effectiveness of HEPA air cleaners vs. other removal mechanisms was predicted to decrease with increasing particle size, because of increasing competition by particle deposition with indoor surfaces and removal to HVAC filters. However, the effect of particle size was relatively small for most scenarios considered here. PRACTICAL IMPLICATIONS: The results of a screening analysis suggest that stand-alone (portable) air cleaners that contain high efficiency particle arresting (HEPA) filters can be effective for reducing indoor fine particle concentrations in residential dwellings during outdoor releases of biological warfare agents. The relative effectiveness of stand-alone air cleaners for reducing occupants' exposure to particles of outdoor origin depends on several factors, including the type of heating, ventilating and air-conditioning (HVAC) filter, HVAC operation, building air exchange rate, particle size, and duration of elevated outdoor particle concentration. Maximum particle reductions, relative to no stand-alone air cleaners, of 90% are predicted when three stand-alone air cleaners are employed.  相似文献   

8.
This paper presents pollutant concentrations and performance data for code-required mechanical ventilation equipment in 23 low-income apartments at 4 properties constructed or renovated 2013-2017. All apartments had natural gas cooking burners. Occupants pledged to not use windows for ventilation during the study but several did. Measured airflows of range hoods and bathroom exhaust fans were lower than product specifications. Only eight apartments operationally met all ventilation code requirements. Pollutants measured over one week in each apartment included time-resolved fine particulate matter (PM2.5), nitrogen dioxide (NO2), formaldehyde and carbon dioxide (CO2) and time-integrated formaldehyde, NO2 and nitrogen oxides (NOX). Compared to a recent study of California houses with code-compliant ventilation, apartments were smaller, had fewer occupants, higher densities, and higher mechanical ventilation rates. Mean PM2.5, formaldehyde, NO2, and CO2 were 7.7 µg/m3, 14.1, 18.8, and 741 ppm in apartments; these are 4% lower, 25% lower, 165% higher, and 18% higher compared to houses with similar cooking frequency. Four apartments had weekly PM2.5 above the California annual outdoor standard of 12 µg/m3 and also discrete days above the World Health Organization 24-hour guideline of 25 µg/m3. Two apartments had weekly NO2 above the California annual outdoor standard of 30 ppb.  相似文献   

9.
深圳居住建筑夏季自然通风降温实验研究   总被引:6,自引:0,他引:6  
以深圳市六种布局不同、楼层不同的居住建筑为对象,调查了夏季室内热环境,测试了不同通风工况下围护结构内表面以及室内外温湿度,分析了居住建筑在夏季采用自然通风降温的可行性,比较了持续自然通风与间歇自然通风的优劣以及不同遮阳方式的遮阳效果,提出了采用自然通风降温方式的条件及建筑设计中应改进之处。  相似文献   

10.
This paper compares apartments in two residential blocks in Vienna; one passive and the other one low-energy. These blocks were constructed simultaneously in the same location and with comparable building construction features and floor plans. The main difference between the two blocks (other than the higher thermal insulation level in the passive building) lies in the ventilation system: passive buildings deploy controlled ventilation, whereas the low-energy buildings rely mostly on user-operated natural (window) ventilation. We measured indoor environmental conditions (indoor air temperature, relative humidity, and CO2 concentration) in two units of each block over a period of five months. Additionally, the buildings were compared in view of operation and embodied energy use, CO2 emissions, and construction costs.  相似文献   

11.
Air quality in two large athletic halls with different ventilation (natural and mechanical) was investigated in relation to outdoor pollution and meteorological conditions. Simultaneous measurements of O3, NO, NO2 and SO2 were performed in the halls at two heights (at the arena and spectators’ seats) and outdoors. BTX concentrations at the spectators’ seats and outdoor NMHCs, CH4, PM10 and CO concentrations were also measured. Analysis of diurnal variations of the pollutants’ concentrations, cross correlation analysis of the concentration time-series and principal component analysis were applied to the collected data. Results revealed that outdoor pollution significantly affected indoor air quality of both halls. However, this effect was different for the two buildings, depending on the ventilation types, the wind direction prevailing at the areas and the kind of indoor activity recorded. It was found that the latter parameters controlled the pollutants concentration levels in the halls and their response to the changes of the outdoor pollution levels. Temperature and pollution stratification enhancing during athletic events were also evident in both halls but with different characteristics observed, such as the spatial distribution of the indoor pollutants. The airflow patterns prevailing in each hall, imposed by the ventilation operation schemes were important factors.  相似文献   

12.
Investigations on indoor environmental conditions and natural ventilation in school buildings. There are more than 40,000 school buildings in Germany. Most of them are awaiting retrofitting. Retrofitting is not only intended to improve the energetic standards, but first of all to improve indoor environmental conditions for pupils and teachers. As most of German schools are not equipped with mechanical ventilation systems, natural ventilation controlled by the occupants opening the windows is the main way to maintain healthy and comfortable conditions in the classrooms. For that purpose the influence of window opening behaviour of the occupants on the indoor environment was measured in two German schools. Temperature and carbon dioxide concentration of the indoor air as well as the outdoor climate conditions were measured. In one school the frequency of window opening was recorded. Besides high CO2‐concentrations especially during winter, some of the investigated classrooms are additionally to cold in winter or to hot in summer. Some classrooms do not have a shading device or the shading device is insufficient or it constricts the ventilation of the room. Windows are used as controls in some degree during lessons and during the breaks. But windows get closed after lessons and stay closed until next morning. There is no night or early morning ventilation in summer. A significant weak to moderate positive correlation between total open window ratio and indoor temperature has been found. Correlation between total open window ratio and outdoor temperature is not significant in most cases or show a weak correlation coefficient.  相似文献   

13.
《Energy and Buildings》2004,36(12):1235-1239
In recent years, more and more people have started to recognize the importance of indoor air environment. In order to obtain the comprehensive knowledge about the indoor environment situation and find out the main source of indoor air pollution, 550 residents living in different buildings/apartments were subjected to a questionnaire survey and field measurements were conducted in 30 of these buildings/apartments in Dalian from January to February 2002. From the questionnaire survey and field measurements, we found that many residential buildings had good outdoor surroundings. Dust and automobile emissions are main sources of outdoor air pollution. Though air tightness of these buildings is fairly good, outdoor air quality still has great impact on indoor air environment. The most serious indoor air pollutant is formaldehyde which is mainly caused by decoration.  相似文献   

14.
In areas with poor ambient air quality, indoor particle concentrations can be significantly affected by particulate matter originating outdoors. The indoor environments of multi-zone and multi-story buildings are affected differently by outdoor particles compared with single-family houses, because of the buildings’ more complicated airflow characteristics. The objective of this study is to analyze outdoor particle penetration and transport, and their impact on indoor air, in a multi-zone and multi-story building using a CONTAMW simulation. For the airflow and particle transport analysis, the building leakage, penetration coefficients, and deposition rates were determined by on-site experiments. The results of airflow simulations for cold winters show that outdoor air infiltrates through the lower part of building and exfiltrates from the upper part. The results of the particle simulation also indicated that the airflow characteristics, combined with deposition rates, cause the lower floors of a multi-story building to be exposed to higher fine particle concentrations compared with the upper floors of the building. The study demonstrated that the CONTAMW simulation can be useful in analyzing the impact of outdoor particles on indoor environments through the identification of key particle transport parameters and validated airflow simulations.  相似文献   

15.
The concentration of ultrafine particles (0.01 to greater than 1 microm) was measured in some rural and urban areas of Sweden and Denmark. The instruments used are handheld real-time condensation particle counters, models CPC 3007 and P-Trak 8525, both manufactured by TSI. Field measurements in Sweden were conducted in a few residential and office buildings, while in Denmark the measurement sites comprised two office buildings, one of them located in a rural area. The concentration of UFPs was measured simultaneously indoors and outdoors with condensation particle counters. The results revealed that the outdoor-generated particle levels were major contributors to the indoor particle number concentration in the studied buildings when no strong internal source was present. The results showed that in office buildings, the UFP concentrations indoors were typically lower and correlated fairly well to the number concentration outdoors. The determined indoor-outdoor ratios varied between 0.5 and 0.8. The indoor levels of UFPs in offices where smoking is allowed was sometimes recorded higher than outdoor levels, as in one of the Danish offices. In residential buildings, the indoor number concentration was strongly influenced by several indoor activities, e.g., cooking and candle burning. In the presence of significant indoor sources, the indoor/outdoor (IO) ratio exceeded unity. The magnitude of UFP concentrations was greater in the large city of Copenhagen compared to the medium-size city of Gothenburg and lowest at more rural sites.  相似文献   

16.
Zhang Q  Zhu Y 《Indoor air》2012,22(1):33-42
This study examined five schools with different ventilation systems in both urban and rural areas in South Texas. Total particle number concentration, ultrafine particle (UFP, diameter < 100 nm) size distribution, PM(2.5) , and CO(2) were measured simultaneously inside and outside of various school microenvironments. Human activities, ventilation settings, and occupancy were recorded. The study found a greater variation of indoor particle number concentration (0.6 × 10(3) -29.3 × 10(3) #/cm(3) ) than of outdoor (1.6 × 10(3) -16.0 × 10(3) #/cm(3) ). The most important factors affecting indoor UFP levels were related to various indoor sources. Gas fan heaters increased the indoor-to-outdoor ratio (I/O ratio) of total particle number concentrations to 30.0. Food-related activities, cleaning, and painting also contributed to the increased indoor particle number concentration with I/O ratios larger than 1.0. Without indoor sources, the I/O ratios for total particles varied from 0.12 to 0.66 for the five ventilation systems studied. The I/O ratio decreased when the outdoor total particle number concentration increased. Particles with diameters <60 nm were less likely to penetrate and stay airborne in indoor environments than larger particles and were measured with smaller I/O ratios. PRACTICAL IMPLICATIONS: From an exposure assessment perspective, schools are important and little-studied microenvironments where students congregate and spend a large proportion of their active time. This study provides information for indoor and outdoor ultrafine particle concentrations at different types of school microenvironments. These data may allow future epidemiological studies to better estimate exposure and assess ultrafine particles health effects among students.  相似文献   

17.
对上海市某住宅建筑室内外PM10、PM2.5、PM1的浓度进行了测量,研究了最小通风量(外门窗关闭)条件下3种天气时颗粒浓度随时间变化的规律以及相关性,分析了颗粒物浓度与环境温湿度参数之间的关系。研究结果显示,测试期间,室内外空气中细颗粒(PM 2.5)占可吸入颗粒(PM 10)浓度比例分别达65%和87%以上;无明显室内源时,I/O比值小于1且随粒径减小而减小;室内外颗粒浓度相关性与粒径大小有关系,PM1、PM2.5的浓度相关性大于PM10。研究还表明,颗粒物浓度的关联性与天气状况有关系,多云、雨天和阴天时浓度关联性有显著差别;颗粒物的浓度受到室内外温湿度的影响,且受天气状况影响而呈现复杂性。  相似文献   

18.
Urban PM2.5 (particulate matter with aerodynamic diameter smaller than 2.5 microm) is associated with excess mortality and other health effects. Stationary sources are regulated and considerable effort is being put into developing low-pollution vehicles and environment-friendly transportation systems. While waiting for technological breakthroughs in emission controls, the current work assesses the exposure reductions achievable by a complementary means: efficient filtration of supply air in buildings. For this purpose infiltration factors for buildings of different ages are quantified using Exposures of Adult Urban Populations in Europe Study (EXPOLIS) measurements of indoor and outdoor concentrations in a population-based probability sample of residential and occupational buildings in Helsinki, Finland. These are entered as inputs into an evaluated simulation model to compare exposures in the current scenario with an alternative scenario, where the distribution of ambient PM2.5 infiltration factors in all residential and occupational buildings are assumed to be similar to the subset of existing occupational buildings using supply air filters. In the alternative scenario exposures to ambient PM2.5 were reduced by 27%. Compared with source controls, a significant additional benefit is that infiltration affects particles from all outdoor sources. The large fraction of time spent indoors makes the reduction larger than what probably can be achieved by local transport policies or other emission controls in the near future. PRACTICAL IMPLICATIONS: It has been suggested that indoor concentrations of ambient particles and the associated health risks can be reduced by using mechanical ventilation systems with supply air filtering in buildings. The current work quantifies the effects of these concentration reductions on population exposures using population-based data from Helsinki and an exposure model. The estimated exposure reductions suggest that correctly defined building codes may reduce annual premature mortality by hundreds in Finland and by tens of thousands in the developed world altogether.  相似文献   

19.
Indoor fine particles (FPs) are a combination of ambient particles that have infiltrated indoors, and particles that have been generated indoors from activities such as cooking. The objective of this paper was to estimate the infiltration factor (Finf) and the ambient/non‐ambient components of indoor FPs. To do this, continuous measurements were collected indoors and outdoors for seven consecutive days in 50 non‐smoking homes in Halifax, Nova Scotia in both summer and winter using DustTrak (TSI Inc) photometers. Additionally, indoor and outdoor gravimetric measurements were made for each 24‐h period in each home, using Harvard impactors (HI). A computerized algorithm was developed to remove (censor) peaks due to indoor sources. The censored indoor/outdoor ratio was then used to estimate daily Finfs and to determine the ambient and non‐ambient components of total indoor concentrations. Finf estimates in Halifax (daily summer median = 0.80; daily winter median = 0.55) were higher than have been reported in other parts of Canada. In both winter and summer, the majority of FP was of ambient origin (daily winter median = 59%; daily summer median = 84%). Predictors of the non‐ambient component included various cooking variables, combustion sources, relative humidity, and factors influencing ventilation. This work highlights the fact that regional factors can influence the contribution of ambient particles to indoor residential concentrations.  相似文献   

20.
Although almost all epidemiological studies of smaller airborne particles only consider outdoor concentrations, people in Central Europe actually spend most of their time indoors. Yet indoor pollutants such as organic gases, allergens and dust are known to play a prominent role, often affecting human health more than outdoor ones. The aim of this study was to ascertain how the indoor particle size distributions of submicron and ultrafine particles correlate with the outdoor concentrations in the absence of significant indoor sources. A typical indoor particle size distribution pattern has one or two modes. In the absence of significant indoor activities such as smoking, cooking etc., outdoor particles were found to be a very important source of indoor particles. The study shows that in the absence of significant indoor sources, the number of indoor concentrations of particles in this size range are clearly lower than the outdoor concentrations. This difference is greater, the higher the number of outdoor concentrations. However, the drop in concentration is not uniform, with the decrease in concentration of smaller particles exceeding that of larger ones. By contrast, the findings with larger particle sizes (diameter > 1 microm) exhibit rather linear concentration decreases. The non-uniform drop in the number of concentrations from outdoors to indoors in our measurements considering smaller particles ( >0.01 microm) is accompanied by a shift of the concentration maxima to larger particle diameters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号