1.
The paper presents a field study of occupants’ thermal comfort and residential thermal environment conducted in an urban and a rural area in Hunan province, which is located in central southern China. The study was performed during the cold winter 2006. Twenty-eight naturally ventilated urban residences and 30 also naturally ventilated rural residences were investigated. A comparative analysis was performed on results from urban and rural residences. The mean thermal sensation vote of rural residences is approximately 0.4 higher than that of urban residences at the same operative temperature. Thermal sensation votes calculated by Fanger’s PMV model did not agree with these obtained directly from the questionnaire data. The neutral operative temperature of urban and rural residences is 14.0 and 11.5 °C, respectively. Percentage of acceptable votes of rural occupants is higher than that of urban occupants at the same operative temperature. It suggests that rural occupants may have higher cold tolerance than urban occupants for their physiological acclimatization, or have relative lower thermal expectation than urban occupants because of few air-conditioners used in the rural area. The research will be instrumental to researchers to formulate thermal standards for naturally ventilated buildings in rural areas.  相似文献   

2.
The purpose of this paper is made to clarify that the relationship between the human physiological and psychological responses and the enhanced conduction-corrected modified effective temperature ETFe as the outdoor thermal environment evaluation index upon the human body. Environmental factors and human physiological and psychological responses were measured. It was made clear that the variables by which summer outdoor environmental factors influence the thermal sensation vote are heat conduction, humidity and short-wave solar radiation. The variables that affect the thermal comfort vote are air velocity, heat conduction and humidity. ETFe, into which the environmental factors that are the variables for human response are incorporated, showed good correspondence with the thermal sensation vote. Similarly, ETFe has a good correspondence with thermal comfort vote. The usage of ETFe as a thermal environment evaluation index for summer outdoor spaces is valid. The threshold for the human body with regards to thermal environment stimuli in an outdoor space is higher than the thermal environment stimuli in a summer indoor space.  相似文献   

3.
《Building and Environment》2001,36(2):231-237
This paper reviews the results from a field survey of thermal comfort within two types of buildings; old (traditional) and new (contemporary), in Ghadames oasis in Libya. The survey was undertaken in the summer seasons 1997 and 1998, which were typical of the hot–dry climate of North Africa. It shows how the 237 residents responded to the environmental conditions. Questionnaires were collected from the residents of 51 buildings: 24 old buildings that employ natural ventilation systems with courtyards and 27 new buildings that employ air-conditioning systems. In addition the environmental parameters were measured in 11 buildings (5 old, 6 new) representing 50 subjects, to calculate the predicted mean vote value of the subject using Fanger’s model as presented in ISO 7730 standard 1995. The survey has shown that the measurements of predicted mean vote (PMV) in new air-conditioned buildings provide satisfactory comfort conditions according to ISO 7730 and the occupants agree by indicating a satisfactory actual mean vote (AMV). The equivalent measurements and survey results in old traditional buildings indicated that although the PMV, based on measurements and ISO 7730, implied discomfort (hot), the occupants expressed their thermal satisfaction with the indoor comfort conditions. The field study also investigated occupants’ overall impression of the indoor thermal environments; the results suggest that people have an overall impression of higher standard of thermal comfort in old buildings than in new buildings.  相似文献   

4.
The relationship between thermal sensation and thermal comfort was studied experimentally under uniform and non-uniform, steady and dynamic conditions separately. Thirty subjects participated in all the experiment and reported their thermal sensation and thermal comfort simultaneously. Thermal sensation and comfort are found to be correlated closely under steady and uniform conditions and the comfort zone of thermal sensation vote in warm side is (0, 1.25). Under steady and non-uniform conditions thermal sensation change with space is found to be an important factor determining thermal comfort. Combining the effects of overall thermal sensation and thermal sensation change with space, a thermal comfort model for steady conditions is proposed. Under dynamic conditions, thermal sensation change with time affects thermal comfort significantly.  相似文献   

5.
The present work is focused on the study of indoor thermal comfort control problem in buildings equipped with HVAC (heating, ventilation and air conditioning) systems. The occupants’ thermal comfort sensation is addressed here by the well-known comfort index known as PMV (predicted mean vote) and by a comfort zone defined in a psychrometric chart. In this context, different strategies for the control algorithms are proposed by using an only-one-actuator system that can be associated to a cooling and/or heating system. The first set of strategies is related to the thermal comfort optimization and the second one includes energy consumption minimization, while maintaining the indoor thermal comfort criterion at an adequate level. The methods are based on the model predictive control scheme and simulation results are presented for two case studies. The results validate the proposed methodology in terms of both thermal comfort and energy savings.  相似文献   

6.
In addition to ensuring the thermal comfort of occupants, monitoring and controlling indoor thermal environments can reduce the energy consumed by air conditioning systems. This study develops an additive model for predicting thermal comfort with rapid and simple arithmetic calculations. The advantage of the additive model is its comprehensibility to administrators of air conditioning systems, who are unfamiliar with the PMV–PPD model but want to adjust an indoor environment to save energy without generating complaints of discomfort from occupants. In order to generate the additive model, a laboratory chamber experiment based on matrix experiment using orthogonal array, was performed. By applying the analysis of variance on observed thermal sensation votes and percentage of dissatisfaction, the factor effects of environmental variables that account for the additive model were determined. Additionally, the applicability of the PMV–PPD model in hot and humid climates is discussed in this study, based on experimental results.  相似文献   

7.
Radiant heating systems are increasingly widely utilized in buildings for its energy conservation potential and enhanced thermal comfort. This paper presented an experiment to compare the thermal comfort performance of radiant heating system with convective heating system through objective measurement and subjective survey. Six physical parameters which might influence occupants' thermal satisfaction, including the Mean Radiant Temperature(MRT), humidity, air movement, A-weighted sound level,temperature fluctuation and vertical temperature difference, were measured. In addition, 97 subjects participated in the subjective survey part of this experiment, experiencing all the three environments heated by air source heat pump, radiator and floor heating.And they were asked to vote in six thermal comfort related aspects, i.e. thermal sensation, humidity, draught, local discomfort,overall thermal satisfaction and overall preferences, plus the acoustic environment, since the operation noise of heating system might lead to complains of the occupants. It was found that in continuous heating, no significant difference between radiant and convective heating system was observed in the Mean Radiant Temperature(MRT), indoor humidity and noise issue. Though radiant heating systems resulted in lower draught risk and less local discomfort complains in the feet region due to the less significant temperature fluctuations and vertical temperature gradients, radiant heating did not have significantly higher overall thermal satisfaction votes and was not significantly more preferred by occupants.  相似文献   

8.
Forty years of Fanger’s model of thermal comfort: comfort for all?   总被引:1,自引:0,他引:1  
van Hoof J 《Indoor air》2008,18(3):182-201
The predicted mean vote (PMV) model of thermal comfort, created by Fanger in the late 1960s, is used worldwide to assess thermal comfort. Fanger based his model on college-aged students for use in invariant environmental conditions in air-conditioned buildings in moderate thermal climate zones. Environmental engineering practice calls for a predictive method that is applicable to all types of people in any kind of building in every climate zone. In this publication, existing support and criticism, as well as modifications to the PMV model are discussed in light of the requirements by environmental engineering practice in the 21st century in order to move from a predicted mean vote to comfort for all. Improved prediction of thermal comfort can be achieved through improving the validity of the PMV model, better specification of the model's input parameters, and accounting for outdoor thermal conditions and special groups. The application range of the PMV model can be enlarged, for instance, by using the model to assess the effects of the thermal environment on productivity and behavior, and interactions with other indoor environmental parameters, and the use of information and communication technologies. Even with such modifications to thermal comfort evaluation, thermal comfort for all can only be achieved when occupants have effective control over their own thermal environment. PRACTICAL IMPLICATIONS: The paper treats the assessment of thermal comfort using the PMV model of Fanger, and deals with the strengths and limitations of this model. Readers are made familiar to some opportunities for use in the 21st-century information society.  相似文献   

9.
Sheng Zhang  Zhang Lin 《Indoor air》2020,30(5):1052-1062
Thermal adaptations, as feedbacks of occupants to physical stimuli, extend thermal comfort zone thereby reducing building energy consumption effectively. The rational approach models thermal comfort from the perspective of the body's heat balance, but is limited in explaining the thermal adaptations. The adaptive approach of modeling thermal comfort can fully account for the thermal adaptations, but ignores the body's heat balance. To improve thermal comfort prediction, this study proposes an adaptive-rational thermal comfort model, that is, an adaptive predicted mean vote with a variable adaptive coefficient (termed as arPMV). By linearly linking the negative feedback effects of the thermal adaptations to the ambient temperature according to the adaptive approach, the variable adaptive coefficient is linearly related to the reciprocal of the ambient temperature with two constants. The variable adaptive coefficient is determined by explicitly quantifying the two constants as the functions of the predicted mean vote, thermal sensation vote, and ambient temperature. The proposed arPMV is validated for naturally ventilated, air-conditioned, and mixed-mode buildings, with the mean absolute error and the robustness of the thermal sensation prediction reduced by 24.8%-83.5% and improved by 49.7%-83.4%, respectively.  相似文献   

10.
Zhou X  Ouyang Q  Lin G  Zhu Y 《Indoor air》2006,16(5):348-355
Airflow fluctuation is an important factor affecting indoor thermal environments and human thermal response. In this study, dynamic airflows with different fluctuation characteristics were generated by a dynamic air supply terminal. The influence of three different kinds of airflows, constant airflow, simulated natural airflow and sinusoidal airflow, on thermal comfort was studied. Subjective experiments indicated that a dynamic airflow can cause a stronger cold sensation, and that air movement with 1/f fluctuations similar to natural wind is more acceptable than other dynamic airflows in warm environments. Moreover, the impact of draughts in dynamic airflows on human thermal response is different in neutral-warm (30 degrees C) and cool-neutral (26 degrees C) thermal environments. PRACTICAL IMPLICATIONS: By means of a dynamic air supply terminal it is possible to generate artificial airflows that simulate natural wind indoors. This kind of airflow with higher velocity is more comfortable and causes less draught sensation than the constant airflows supplied by conventional fans. While the cooling effect of this airflow is utilized in the built environment, the design temperature of air-conditioning system can be increased and the amount of energy consumption can be reduced dramatically.  相似文献   

11.
This study was conducted during the summer and winter in Beijing. Classrooms and offices in a university were used to conduct the survey. The respondents’ thermal sensation and thermal adaptability in both seasons were analyzed. During the study, indoor environmental parameters including air temperature, mean radiant temperature, relative humidity, and air velocity were measured. The respondents’ thermal sensation was determined by questionnaire.A relationship between indoor temperature and thermal sensation was found. In the summer study, the “scissors difference” between TSV and PMV was observed in the air-conditioned environments if the temperature was out of the neutral zone. People had higher tolerance in the hot environment than PMV predicted. During winter, the outdoor temperature had a prominent influence on thermal adaptability. The low outdoor temperature made people adapt to the cold environment. When the indoor temperature was heated to a high temperature by space heating facilities, respondents felt uncomfortable since their adaptability to the cold environment was nullified.Furthermore, the differences in thermal responses between respondents from North and South China showed that the different climates of people's native regions also affected their thermal comfort and adaptability.  相似文献   

12.
Field survey was conducted to evaluate thermal comfort perception of the occupants in naturally ventilated public housing in Singapore. Thermal acceptability assessment was performed to find out whether the naturally ventilated indoor environment meets the ASHRAE Standard-55's 80% acceptability criteria. The study investigated whether thermal perception was influenced by different sessions of the day, building height, and flat types. Comparative analysis of thermal sensation and thermal comfort votes revealed that a high proportion of people experiencing sensations of +2,+3 still found the conditions to be comfortable. The survey also examined the adaptive behavior of the occupants in the usage of climatic control such as windows, fans and air-conditioning to modify the indoor environment.  相似文献   

13.
热湿环境下人体热反应的实验研究   总被引:17,自引:4,他引:17  
采用问卷方式,对热湿环境下人体热感觉、对空气湿度的感觉、吹风感觉及热舒适感觉进行了研究,分析了空气相对湿度对热舒适的影响,给出了高温高湿条件下人体热反应的规律。并在分析人体散热的基础上,提出了一个可以对热湿环境中人体热舒适进行预测的数学模型。  相似文献   

14.
The building industry needs a fundamental paradigm shift in its notion of comfort, to find low-energy ways of creating more thermally dynamic and non-uniform environments that bring inhabitants pleasure. Strategies for providing enriched thermal environments must be conjoined with reducing energy; these are inseparable for any building striving for high performance. The objective of current comfort standards is to have no more than 20% of occupants dissatisfied, yet buildings are not reaching even that scant goal. A significant energy cost is incurred by the current practice of controlling buildings within a narrow range of temperatures (often over-cooling in the summer). If building designers and operators can find efficient ways to allow building temperatures to float over a wider range, while affording occupants individual control of comfort, the potential for energy savings is enormous. Five new ways of thinking, or paradigm shifts, are presented for designing or operating buildings to provide enhanced thermal experiences. They are supported by examples of research conducted by the Center for the Built Environment, and include shifts from centralized to personal control, from still to breezy air movement, from thermal neutrality to delight, from active to passive design, and from system disengagement to improved feedback loops.  相似文献   

15.
沈阳市商场冬季室内热舒适的模糊分析   总被引:1,自引:0,他引:1  
对沈阳市冬季商场室内热环境状况进行了实地调查,建立了基于自适应性模糊神经网络的人体热舒适模糊评判模型,对采集到的数据进行了模糊推理和网络训练,总结出了关于人体热舒适的模糊推理规则。由仿真结果可知,模糊评判模型输出值与热感觉投票值吻合较好,为客观评价和预测人体热舒适提供了一种方法和思路。  相似文献   

16.
There is a dearth of thermal comfort studies in India. It is aimed to investigate into the aspects of thermal comfort in Hyderabad and to identify the neutral temperature in residential environments. This was achieved through a thermal comfort field study in naturally ventilated apartment buildings conducted during summer and monsoon involving over 100 subjects. A total of 3962 datasets were collected covering their thermal responses and the measurement of the thermal environment. The comfort band (voting within –1 and +1), based on the field study, was found to be 26–32.45°C, with the neutral temperature at 29.23°C. This is way above the indoor temperature standards specified in Indian Codes. It was found that the regression neutral temperature and the globe temperature recorded when voting neutral converged when mean thermal sensation of the subjects was close to 0. This happened during the period of moderate temperature when the adaptive measures were adequate. The indoor temperatures recorded in roof-exposed (top floor) flats were higher than the lower floors. The thermal sensation and preference votes of subjects living in top floors were always higher. Consequently, their acceptance vote was also lower. It was found that the subjects living in top floor flats had a higher neutral temperature when the available adaptive opportunities were sufficient. This was due to their continuous exposure to a higher thermal regime due to much higher solar exposure. This study calls for special adaptive measures for roof-exposed flats to achieve neutrality at higher temperature.  相似文献   

17.
This field study was performed during the winter of 2000–2001 in order to investigate the thermal environment and thermal comfort in residential buildings in Harbin, northeast of China. A total of 120 participants provided 120 sets of physical data and subjective questionnaires. An indoor climate analyzer and a thermal comfort meter made in Denmark were used to collect the measured parameters of the indoor environment, the predicted mean vote (PMV), and predicted percentage of dissatisfied (PPD). The conclusions are as follows: males are less sensitive to temperature variations than females; the neutral operative temperature of males is 1 °C lower than that of females; Harbin subjects are as sensitive to temperature variations as the Beijing and Tianjin subjects; the minimum value of PPD (7.5%) is similar to the Tianjin occupants; both the sensitivity and the minimum value of PPD are lower than those of the foreign field studies.  相似文献   

18.
Ye XJ  Zhou ZP  Lian ZW  Liu HM  Li CZ  Liu YM 《Indoor air》2006,16(4):320-326
A long-term field investigation was carried out in naturally ventilated residential buildings in Shanghai from April 2003 to November 2004. A total of 1,768 returned questionnaires were collected in the study. This study deals with the thermal sensation of occupants in naturally ventilated buildings and the change in thermal neutral temperature with season. The range of accepted temperature in naturally ventilated buildings is between 14.7 degrees C T(op) and 29.8 degrees C T(op). The results also report the findings of the adaptive comfort model in Shanghai that determines the adaptive relationship of neutral temperature with outdoor air temperature. A long-term field study was carried out in residential buildings in Shanghai to find the relationship between thermal sensation, indoor neutral temperature and outdoor temperature. This paper presents findings of thermal comfort and discusses the more sustainable standard for the indoor climate of residential buildings in Shanghai.  相似文献   

19.
A three-part series presents the development of models for predicting the local thermal sensation (Part I) and local thermal comfort (Part II) of different parts of the human body, and also the whole-body sensation and comfort (Part III) that result from combinations of local sensation and comfort. The models apply to sedentary activities in a range of environments: uniform and non-uniform, stable and transient. They are based on diverse findings from the literature and from body-part-specific human subject tests in a climate chamber. They were validated against a test of automobile passengers. The series is intended to present the models’ rationale, structure, and coefficients, so that others can test them and develop them further as additional empirical data becomes available.A) The whole-body (overall) sensation model has two forms, depending on whether all of the body's segments have sensations effectively in the same direction (e.g warm or cool), or whether some segments have sensations opposite to those of the rest of the body. For each, individual body parts have different weights for warm versus cool sensations, and strong local sensations dominate the overall sensation. If all sensations are near neutral, the overall sensation is close to the average of all body sensations.B) The overall comfort model also has two forms. Under stable conditions, people evaluate their overall comfort by a complaint-driven process, meaning that when two body parts are strongly uncomfortable, no matter how comfortable the other body parts might be, the overall comfort will be near the discomfort level of the two most uncomfortable parts. When the environmental conditions are transient, or people have control over their environments, overall comfort is better than that of the two most uncomfortable body parts. This can be accounted for by adding the most comfortable vote to the two most uncomfortable ones.  相似文献   

20.
Studies of thermal comfort of occupants started in the early part of the 20th century to describe the comfort level in terms of environmental variables. Field studies have indicated that many of the complaints about unsatisfactory indoor environment can be attributed to the thermal environment. Hence, heating, ventilation, and air conditioning (HVAC) systems are used in buildings to create thermal environments that are capable of providing comfort to the occupants. Among different ventilation systems, displacement ventilation (DV) systems have become popular as more energy efficient room air distribution systems compared with the other more common forms of air distribution systems, such as mixing ventilation. However, local cold discomfort at the lower extremities due to vertical temperature gradient is often reported with DV systems. Although many studies are reported in the literature that compare the performance of the DV systems with the other more conventional types of ventilation systems, the performance of different displacement ventilation types in providing thermal comfort need further investigation. The aim of the current work is to compare the ventilation performance, as predicted by an advanced thermal comfort model, of three commonly used DV air terminal devices (ATDs) for room ventilation: a flat wall diffuser (ATD1), semi-cylindrical wall diffuser (ATD2) and floor swirl diffusers (ATD3). The CBE (Center for the Built Environment at Berkeley) comfort model has been implemented in this study to compare the thermal comfort provided by the three ATDs due to its good performance in non-uniform thermal environments. Based on the test conditions and the results obtained from the comfort model, the predicted occupant’s local sensations for the case of ATD2 were better than those for ATD1 and ATD3 and it showed better overall thermal sensation. Since the local comfort of the CBE model is a function of both local and overall thermal sensations, the predicted occupant’s local comfort values for ATD2 were better than those for ATD1 and ATD3 and consequently it provided better overall thermal comfort.  相似文献   