首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This field study measured ventilation rates and indoor air quality in 21 visits to retail stores in California. Three types of stores, such as grocery, furniture/hardware stores, and apparel, were sampled. Ventilation rates measured using a tracer gas decay method exceeded the minimum requirement of California's Title 24 Standard in all but one store. Concentrations of volatile organic compounds (VOCs), ozone, and carbon dioxide measured indoors and outdoors were analyzed. Even though there was adequate ventilation according to standard, concentrations of formaldehyde and acetaldehyde exceeded the most stringent chronic health guidelines in many of the sampled stores. The whole‐building emission rates of VOCs were estimated from the measured ventilation rates and the concentrations measured indoor and outdoor. Estimated formaldehyde emission rates suggest that retail stores would need to ventilate at levels far exceeding the current Title 24 requirement to lower indoor concentrations below California's stringent formaldehyde reference level. Given the high costs of providing ventilation, effective source control is an attractive alternative.  相似文献   

2.
This study characterized indoor volatile organic compounds (VOCs) and investigated the effects of the dwelling characteristics, building materials, occupant activities, and environmental conditions on indoor VOC concentrations in 40 dwellings located in Melbourne, Australia, in 2008 and 2009. A total of 97 VOCs were identified. Nine VOCs, n‐butane, 2‐methylbutane, toluene, formaldehyde, acetaldehyde, d‐limonene, ethanol, 2‐propanol, and acetic acid, accounted for 68% of the sum of all VOCs. The median indoor concentrations of all VOCs were greater than those measured outdoors. The occupant density was positively associated with indoor VOC concentrations via occupant activities, including respiration and combustion. Terpenes were associated with the use of household cleaning and laundry products. A petroleum‐like indoor VOC signature of alkanes and aromatics was associated with the proximity of major roads. The indoor VOC concentrations were negatively correlated (P < 0.05) with ventilation. Levels of VOCs in these Australian dwellings were lower than those from previous studies in North America and Europe, probably due to a combination of an ongoing temporal decrease in indoor VOC concentrations and the leakier nature of Australian dwellings.  相似文献   

3.
Measurements were taken in new US residences to assess the extent to which ventilation and source control can mitigate formaldehyde exposure. Increasing ventilation consistently lowered indoor formaldehyde concentrations. However, at a reference air exchange rate of 0.35 h?1, increasing ventilation was up to 60% less effective than would be predicted if the emission rate were constant. This is consistent with formaldehyde emission rates decreasing as air concentrations increase, as observed in chamber studies. In contrast, measurements suggest acetaldehyde emission was independent of ventilation rate. To evaluate the effectiveness of source control, formaldehyde concentrations were measured in Leadership in Energy and Environmental Design (LEED)‐certified/Indoor airPLUS homes constructed with materials certified to have low emission rates of volatile organic compounds (VOC). At a reference air exchange rate of 0.35 h?1, and adjusting for home age, temperature and relative humidity, formaldehyde concentrations in homes built with low‐VOC materials were 42% lower on average than in reference new homes with conventional building materials. Without adjustment, concentrations were 27% lower in the low‐VOC homes. The mean and standard deviation of formaldehyde concentration was 33 μg/m3 and 22 μg/m3 for low‐VOC homes and 45 μg/m3 and 30 μg/m3 for conventional.  相似文献   

4.
In retail stores, workers are constantly exposed to new manufactured goods. The issue of the exposure of retail workers to volatile organic compounds (VOCs) should clearly be considered. Therefore, this study provides data regarding VOC concentrations in ten French retail stores. The stores were chosen to represent various products: sports goods, shoes and leather, furniture, car equipment, bazaars, online-sales storage, clothes, books, DIY (do-it-yourself), and household appliances. VOCs and aldehydes were actively sampled on the same day in five to seven locations per building and outdoors. Toluene and formaldehyde were omnipresent with indoor concentrations reaching 252 and 53 µg/m3, respectively. The car equipment store, followed by clothing, shoes, and leather, and DIY stores showed the worst indoor air quality. High concentrations were measured, for example, the maximum α-pinene concentration in the furniture and DIY stores was 364 and 141 µg/m3, respectively, and the heptane concentration in the car equipment store reached 1,316 µg/m3. Two VOCs classified as toxic to reproduction were measured: hexane in the car equipment store and the bazaar, and dimethylformamide in the sports goods store. This study shows some disparities in the indoor concentrations among different locations in the same store, particularly between sales and storage areas.  相似文献   

5.
We measured particulate matter (PM), acrolein, and other indoor air contaminants in eight visits to grocery stores in California. Retail stores of other types (hardware, furniture, and apparel) were also sampled on additional visits. Based on tracer gas decay data, most stores had adequate ventilation according to minimum ventilation rate standards. Grocery stores had significantly higher concentrations of acrolein, fine and ultrafine PM, compared to other retail stores, likely attributable to cooking. Indoor concentrations of PM2.5 and acrolein exceeded health guidelines in all tested grocery stores. Acrolein emission rates to indoors in grocery stores had a mean estimate about 30 times higher than in other retail store types. About 80% of the indoor PM2.5 measured in grocery stores was emitted indoors, compared to only 20% for the other retail store types. Calculations suggest a substantial increase in outdoor air ventilation rate by a factor of three from current level is needed to reduce indoor acrolein concentrations. Alternatively, acrolein emission to indoors needs to be reduced 70% by better capturing of cooking exhaust. To maintain indoor PM2.5 below the California annual ambient standard of 12 μg/m3, grocery stores need to use air filters with an efficiency rating higher than the MERV 8 air filters commonly used today.  相似文献   

6.
We assessed the chronic health risks from inhalation exposure to volatile organic compounds (VOCs) and particulate matter (PM2.5) in U.S. offices, schools, grocery, and other retail stores and evaluated how chronic health risks were affected by changes in ventilation rates and air filtration efficiency. Representative concentrations of VOCs and PM2.5 were obtained from available data. Using a mass balance model, changes in exposure to VOCs and PM2.5 were predicted if ventilation rate were to increase or decrease by a factor of two, and if higher efficiency air filters were used. Indoor concentrations were compared to health guidelines to estimate percentage exceedances. The estimated chronic health risks associated with VOC and PM2.5 exposures in these buildings were low relative to the risks from exposures in homes. Chronic health risks were driven primarily by exposures to PM2.5 that were evaluated using disease incidence of mortality, chronic bronchitis, and non‐fatal stroke. The leading cancer risk factor was exposure to formaldehyde. Using disability‐adjusted life years (DALYs) to account for both cancer and non‐cancer effects, results suggest that increasing ventilation alone is ineffective at reducing chronic health burdens. Other strategies, such as pollutant source control and the use of particle filtration, should also be considered.  相似文献   

7.
Indoor air quality was characterized in 10 recently built energy‐efficient French schools during two periods of 4.5 days. Carbon dioxide time‐resolved measurements during occupancy clearly highlight the key role of the ventilation rate (scheduled or occupancy indexed), especially in this type of building, which was tightly sealed and equipped with a dual‐flow ventilation system to provide air refreshment. Volatile organic compounds (VOCs) and inorganic gases (ozone and NO2) were measured indoors and outdoors by passive techniques during the occupied and the unoccupied periods. Over 150 VOC species were identified. Among them, 27 species were selected for quantification, based on their occurrence. High concentrations were found for acetone, 2‐butanone, formaldehyde, toluene, and hexaldehyde. However, these concentrations are lower than those previously observed in conventional school buildings. The indoor/outdoor and unoccupied/occupied ratios are informative regarding emission sources. Except for benzene, ozone, and NO2, all the pollutants in these buildings have an indoor source. Occupancy is associated with increased levels of acetone, 2‐butanone, pentanal, butyl acetate, and alkanes.  相似文献   

8.
M. Zaatari  J. Siegel 《Indoor air》2014,24(4):350-361
Particles in retail environments can have consequences for the occupational exposures of retail workers and customers, as well as the energy costs associated with ventilation and filtration. Little is known about particle characteristics in retail environments. We measured indoor and outdoor mass concentrations of PM10 and PM2.5, number concentrations of submicron particles (0.02–1 μm), size‐resolved 0.3–10 μm particles, as well as ventilation rates in 14 retail stores during 24 site visits in Pennsylvania and Texas. Overall, the results were generally suggestive of relatively clean environments when compared to investigations of other building types and ambient/occupational regulatory limits. PM10 and PM2.5 concentrations (mean ± s.d.) were 20 ± 14 and 11 ± 10 μg/m3, respectively, with indoor‐to‐outdoor ratios of 1.0 ± 0.7 and 0.88 ± 1.0. Mean submicron particle concentrations were 7220 ± 7500 particles/cm3 with an indoor‐to‐outdoor ratio of 1.18 ± 1.30. The median contribution to PM10 and PM2.5 concentrations from indoor sources (vs. outdoors) was 83% and 53%, respectively. There were no significant correlations between measured ventilation rates and particle concentrations of any size. When examining options to lower PM2.5 concentrations below regulatory limits, the required changes to ventilation and filtration efficiency were site specific and depended on the indoor and outdoor concentration, emission rate, and infiltration level.  相似文献   

9.
Hotel housekeepers represent a large, low-income, predominantly minority, and high-risk workforce. Little is known about their exposure to chemicals, including volatile organic compounds (VOCs). This study evaluates VOC exposures of housekeepers, sources and factors affecting VOC levels, and provides preliminary estimates of VOC-related health risks. We utilized indoor and personal sampling at two hotels, assessed ventilation, and characterized the VOC composition of cleaning agents. Personal sampling of hotel staff showed a total target VOC concentration of 57 ± 36 µg/m3 (mean ± SD), about twice that of indoor samples. VOCs of greatest health significance included chloroform and formaldehyde. Several workers had exposure to alkanes that could cause non-cancer effects. VOC levels were negatively correlated with estimated air change rates. The composition and concentrations of the tested products and air samples helped identify possible emission sources, which included building sources (for formaldehyde), disinfection by-products in the laundry room, and cleaning products. VOC levels and the derived health risks in this study were at the lower range found in the US buildings. The excess lifetime cancer risk (average of 4.1 × 10−5) still indicates a need to lower exposure by reducing or removing toxic constituents, especially formaldehyde, or by increasing ventilation rates.  相似文献   

10.
This research assesses benefits of adding to California Title‐24 ventilation rate (VR) standards a performance‐based option, similar to the American Society of Heating, Refrigerating, and Air Conditioning Engineers ‘Indoor Air Quality Procedure’ (IAQP) for retail spaces. Ventilation rates and concentrations of contaminants of concern (CoC) were measured in 13 stores. Mass balance models were used to estimate ‘IAQP‐based’ VRs that would maintain concentrations of all CoCs below health‐ or odor‐based reference concentration limits. An intervention study in a ‘big box’ store assessed how the current VR, the Title 24‐prescribed VR, and the IAQP‐based VR (0.24, 0.69, and 1.51 air changes per hour) influenced measured IAQ and perceived of IAQ. Neither current VRs nor Title 24‐prescribed VRs would maintain all CoCs below reference limits in 12 of 13 stores. In the big box store, the IAQP‐based VR kept all CoCs below limits. More than 80% of subjects reported acceptable air quality at all three VRs. In 11 of 13 buildings, saving energy through lower VRs while maintaining acceptable IAQ would require source reduction or gas‐phase air cleaning for CoCs. In only one of the 13 retail stores surveyed, application of the IAQP would have allowed reduced VRs without additional contaminant‐reduction strategies.  相似文献   

11.
To conserve energy, office buildings with air-conditioning systems in Thailand are operated with a tight thermal envelope. This leads to low fresh-air ventilation rates and is thought to be partly responsible for the sick building syndrome symptoms reported by occupants. The objectives of this study are to measure concentrations and to determine sources of 13 volatile organic compounds (VOCs) in office buildings with air-conditioning systems in the business area of Bangkok. Indoor and outdoor air samples from 17 buildings were collected on Tenax-TA sorbent tubes and analyzed for individual VOCs by thermal desorption-gas chromatography/mass spectrometry (TD–GC/MS). Building ventilation was measured with a constant injection technique using hexafluorobenzene as a tracer gas. The results show that the VOC concentrations varied significantly among the studied buildings. The two most dominant VOCs were toluene and limonene with average concentrations of 110 and 60.5 μg m−3, respectively. A Wilcoxon sum rank test indicated that the indoor concentrations of aromatic compounds and limonene were statistically higher than outdoor concentrations at the 0.05 level, while the indoor concentrations of chlorinated compounds were not. Indoor emission factors of toluene and limonene were found to be highest with the average values of 80.9 and 18.9 μg m−2 h−1, respectively. Principal component analysis was applied to the emission factors of 13 VOCs, producing three components based on source similarities. Furthermore, a questionnaire survey investigation and field measurements of building air exchange pointed to indoor air complaints related to inadequate ventilation.  相似文献   

12.
Hodgson AT  Rudd AF  Beal D  Chandra S 《Indoor air》2000,10(3):178-192
Concentrations of 54 volatile organic compounds (VOCs) and ventilation rates were measured in four new manufactured houses over 2-9.5 months following installation and in seven new site-built houses 1-2 months after completion. The houses were in four projects located in hot-humid and mixed-humid climates. They were finished and operational, but unoccupied. Ventilation rates ranged from 0.14-0.78 h-1. Several of the site-built houses had ventilation rates below the ASHRAE recommended value. In both manufactured and site-built houses, the predominant airborne compounds were alpha-pinene, formaldehyde, hexanal, and acetic acid. Formaldehyde concentrations were below or near 50 ppb with a geometric mean value for all houses of 40 ppb. Similarities in the types of VOCs and in VOC concentrations indicated that indoor air quality in the houses was impacted by the same or similar sources. Major identified sources included plywood flooring, latex paint and sheet vinyl flooring. One site-built house was operated at ventilation rates of 0.14 and 0.32 h-1. VOC emission rates calculated at the two conditions agreed within +/- 10% for the most volatile compounds. Generally, the ratios of emission rates at the low and high ventilation rates decreased with decreasing compound volatility. Changes in VOC emission rates in the manufactured houses over 2-9.5 months after installation varied by compound. Only several compounds showed a consistent decrease in emission rate over this period.  相似文献   

13.
We investigate source characteristics and emission dynamics of volatile organic compounds (VOCs) in a single‐family house in California utilizing time‐ and space‐resolved measurements. About 200 VOC signals, corresponding to more than 200 species, were measured during 8 weeks in summer and five in winter. Spatially resolved measurements, along with tracer data, reveal that VOCs in the living space were mainly emitted directly into that space, with minor contributions from the crawlspace, attic, or outdoors. Time‐resolved measurements in the living space exhibited baseline levels far above outdoor levels for most VOCs; many compounds also displayed patterns of intermittent short‐term enhancements (spikes) well above the indoor baseline. Compounds were categorized as “high‐baseline” or “spike‐dominated” based on indoor‐to‐outdoor concentration ratio and indoor mean‐to‐median ratio. Short‐term spikes were associated with occupants and their activities, especially cooking. High‐baseline compounds indicate continuous indoor emissions from building materials and furnishings. Indoor emission rates for high‐baseline species, quantified with 2‐hour resolution, exhibited strong temperature dependence and were affected by air‐change rates. Decomposition of wooden building materials is suggested as a major source for acetic acid, formic acid, and methanol, which together accounted for ~75% of the total continuous indoor emissions of high‐baseline species.  相似文献   

14.
Although elevated nitrogen dioxide (NO2) exposures may exacerbate asthma, few studies have examined indoor NO2 levels in low-income, urban neighborhoods, where asthma prevalence is high. As part of the Healthy Public Housing Initiative, NO2 was measured in 77 homes within three Boston public housing developments, using Palmes tubes placed in the kitchen, living room, and outdoors. Air exchange rates (AERs) were assessed using a perfluorocarbon tracer technique. Overall NO2 levels were [mean (ppb)+/-s.d.]: kitchen (43+/-20, n=100), living room (36+/-17, n=102), outdoor (19+/-6, n=91). Indoor NO2 levels were significantly higher in the heating season (living room: 43 ppb vs. 26 ppb, kitchen: 50 ppb vs. 33 ppb), while AERs were significantly lower in the heating season (medians 0.49/h vs. 0.85/h). Significant univariate predictors of indoor concentrations include: outdoor NO2 levels, AERs, and occupancy. AERs and outdoor NO2 remained significant in multivariate models (P<0.05). A dummy variable for supplemental heating with gas stove was not significant (P=0.14), but had a large, positive coefficient. Indoor NO2 levels in this cohort are higher than those generally reported in residential US settings, associated in part with increased gas stove usage and decreased AERs during the heating season. PRACTICAL IMPLICATIONS: Indoor air quality is mainly a function of outdoor concentrations, indoor sources, ventilation, and residential behavior. Indoor exposures to nitrogen dioxide and other combustion pollutants may be elevated within low-income housing developments due to the presence of multiple sources, poor ventilation, small apartment size, and behavioral responses to apartment conditions (e.g. supplemental heating with gas stove). This information may be used by housing authorities and other landlords to decrease potential environmental stressors, through interventions such as source substitution and improved ventilation, particularly for sensitive sub-populations such as asthmatics.  相似文献   

15.
Retail stores contain a wide range of products that can emit a variety of indoor pollutants. Among these chemicals, phthalate esters and polybrominated diphenyl ethers (PBDEs) are two important categories of semi‐volatile organic compounds (SVOCs). Filters in heating, ventilation, and air‐conditioning (HVAC) system collect particles from large volumes of air and thus potentially provide spatially and temporally integrated SVOC concentrations. This study measured six phthalate and 14 PBDE compounds in HVAC filter dust in 14 retail stores in Texas and Pennsylvania, United States. Phthalates and PBDEs were widely found in the HVAC filter dust in retail environment, indicating that they are ubiquitous indoor pollutants. The potential co‐occurrence of phthalates and PBDEs was not strong, suggesting that their indoor sources are diverse. The levels of phthalates and PBDEs measured in HVAC filter dust are comparable to concentrations found in previous investigations of settled dust in residential buildings. Significant correlations between indoor air and filter dust concentrations were found for diethyl phthalate, di‐n‐butyl phthalate, and benzyl butyl phthalate. Reasonable agreement between measurements and an equilibrium model to describe SVOC partitioning between dust and gas‐phase is achieved.  相似文献   

16.
Indoor fine particles (FPs) are a combination of ambient particles that have infiltrated indoors, and particles that have been generated indoors from activities such as cooking. The objective of this paper was to estimate the infiltration factor (Finf) and the ambient/non‐ambient components of indoor FPs. To do this, continuous measurements were collected indoors and outdoors for seven consecutive days in 50 non‐smoking homes in Halifax, Nova Scotia in both summer and winter using DustTrak (TSI Inc) photometers. Additionally, indoor and outdoor gravimetric measurements were made for each 24‐h period in each home, using Harvard impactors (HI). A computerized algorithm was developed to remove (censor) peaks due to indoor sources. The censored indoor/outdoor ratio was then used to estimate daily Finfs and to determine the ambient and non‐ambient components of total indoor concentrations. Finf estimates in Halifax (daily summer median = 0.80; daily winter median = 0.55) were higher than have been reported in other parts of Canada. In both winter and summer, the majority of FP was of ambient origin (daily winter median = 59%; daily summer median = 84%). Predictors of the non‐ambient component included various cooking variables, combustion sources, relative humidity, and factors influencing ventilation. This work highlights the fact that regional factors can influence the contribution of ambient particles to indoor residential concentrations.  相似文献   

17.
Ventilation standards, health, and indoor air quality have not been adequately examined for residential weatherization. This randomized trial showed how ASHRAE 62‐1989 (n=39 houses) and ASHRAE 62.2‐2010 (n=42 houses) influenced ventilation rates, moisture balance, indoor air quality, and self‐reported physical and mental health outcomes. Average total airflow was nearly twice as high for ASHRAE 62.2‐2010 (79 vs. 39 cfm). Volatile organic compounds, formaldehyde and carbon dioxide were all significantly reduced for the newer standard and first‐floor radon was marginally lower, but for the older standard, only formaldehyde significantly decreased. Humidity in the ASHRAE 62.2‐2010 group was only about half that of the ASHRAE 62‐1989 group using the moisture balance metric. Radon was higher in the basement but lower on the first floor for ASHRAE 62.2‐2010. Children in each group had fewer headaches, eczema, and skin allergies after weatherization and adults had improvements in psychological distress. Indoor air quality and health improve when weatherization is accompanied by an ASHRAE residential ventilation standard, and the 2010 ASHRAE standard has greater improvements in certain outcomes compared to the 1989 standard. Weatherization, home repair, and energy conservation projects should use the newer ASHRAE standard to improve indoor air quality and health.  相似文献   

18.
Ultraviolet photocatalytic oxidation (UVPCO) systems for removal of volatile organic compounds (VOCs) from air are being considered for use in office buildings. Here, we report an experimental evaluation of a UVPCO device with tungsten oxide modified titanium dioxide (TiO2) as the photocatalyst. The device was challenged with complex VOC mixtures. One mixture contained 27 VOCs characteristic of office buildings and another comprised 10 VOCs emitted by cleaning products, in both cases at realistic concentrations (low ppb range). VOC conversion efficiencies varied widely, usually exceeded 20%, and were as high as approximately 80% at about 0.03 s residence time. Conversion efficiency generally diminished with increased airflow rate, and followed the order: alcohols and glycol ethers > aldehydes, ketones, and terpene hydrocarbons > aromatic and alkane hydrocarbons > halogenated aliphatic hydrocarbons. Conversion efficiencies correlated with the Henry's law constant more closely than with other physicochemical parameters. An empirical model based on the Henry's law constant and the gas-phase reaction rate with hydroxyl radical provided reasonable estimates of pseudo-first order photocatalytic reaction rates. Formaldehyde, acetaldehyde, acetone, formic acid and acetic acid were produced by the device due to incomplete mineralization of common VOCs. Formaldehyde outlet/inlet concentration ratios were in the range 1.9-7.2. PRACTICAL IMPLICATIONS: Implementation of air cleaning technologies for both VOCs and particles in office buildings may improve indoor air quality, or enable indoor air quality levels to be maintained with reduced outdoor air supply and concomitant energy savings. One promising air cleaning technology is ultraviolet photocatalytic oxidation (UVPCO) air cleaning. For the prototype device evaluated here with realistic mixtures of VOCs, conversion efficiencies typically exceeded the minimum required to counteract predicted VOC concentration increases from a 50% reduction in ventilation. However, the device resulted in the net generation of formaldehyde and acetaldehyde from the partial oxidation of ubiquitous VOCs. Further development of the technology is needed to eliminate these hazardous air pollutants before such a UVPCO device can be deployed in buildings.  相似文献   

19.
Little information is available about air quality in early childhood education (ECE) facilities. We collected single‐day air samples in 2010–2011 from 40 ECE facilities serving children ≤6 years old in California and applied new methods to evaluate cancer risk in young children. Formaldehyde and acetaldehyde were detected in 100% of samples. The median (max) indoor formaldehyde and acetaldehyde levels (μg/m3) were 17.8 (48.8) and 7.5 (23.3), respectively, and were comparable to other California schools and homes. Formaldehyde and acetaldehyde concentrations were inversely associated with air exchange rates (Pearson r = ?0.54 and ?0.63, respectively; P < 0.001). The buildings and furnishings were generally >5 years old, suggesting other indoor sources. Formaldehyde levels exceeded California 8‐h and chronic Reference Exposure Levels (both 9 μg/m3) for non‐cancer effects in 87.5% of facilities. Acetaldehyde levels exceeded the U.S. EPA Reference Concentration in 30% of facilities. If reflective of long‐term averages, estimated exposures would exceed age‐adjusted ‘safe harbor levels’ based on California's Proposition 65 guidelines (10?5 lifetime cancer risk). Additional research is needed to identify sources of formaldehyde and acetaldehyde and strategies to reduce indoor air levels. The impact of recent California and proposed U.S. EPA regulations to reduce formaldehyde levels in future construction should be assessed.  相似文献   

20.
This study measured air exchange rates, indoor concentrations of aldehydes and volatile organic compounds (VOCs), and radioactivity levels at 19 temporary houses in different temporary housing estate constructed in Minamisoma City following the Great East Japan Earthquake. The 19 surveyed houses represented all of the companies assigned to construct temporary houses in that Minamisoma City. Data were collected shortly after construction and before occupation, from August 2011 to January 2012. Mean air exchange rates in the temporary houses were 0.28/h, with no variation according to housing types and construction date. Mean indoor concentrations of formaldehyde, acetaldehyde, toluene, ethylbenzene, m/p‐xylene, o‐xylene, styrene, p‐dichlorobenzene, tetradecane, and total VOCs (TVOCs) were 29.2, 72.7, 14.6, 6.35, 3.05, 1.81, 7.29, 14.3, 8.32, and 901 μg/m3, respectively. The levels of acetaldehyde and TVOCs exceeded the indoor guideline (48 μg/m3) and interim target (400 μg/m3) in more than half of the 31 rooms tested. In addition to guideline chemicals, terpenes (α‐pinene and d‐limonene) and acetic esters (butyl acetate and ethyl acetate) were often detected in these houses. The indoor radiation levels measured by a Geiger–Müller tube (Mean: 0.22 μSv/h) were lower than those recorded outdoors (Mean: 0.42 μSv/h), although the shielding effect of the houses was less than for other types of buildings.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号