共查询到20条相似文献,搜索用时 955 毫秒
1.
2.
以印染废水的COD和浊度为指标,考察氧化-混凝法(Fenton试剂-PAFC-CPAM)处理印染废水的效果。试验结果表明, Fenton试剂单独处理印染废水时,在pH值为4, FeSO4和H2O2的投加量分别为0.3、 1.32 g/L时,COD的质量浓度和浊度分别降至602.3 mg/L和60 NTU。Fenton试剂与PAFC(0.5 g/L)联合处理时, COD的质量浓度和浊度分别降至484.6 mg/L和38 NTU,继续投加6 mg/L的CPAM后, COD的质量浓度和浊度分别降至419.9 mg/L和25 NTU, COD去除率达到了51.22%。Fenton试剂-PAFC-CPAM联合处理印染废水的效果明显优于单一试剂。 相似文献
3.
4.
气动絮凝强化城市污水一级处理试验研究 总被引:1,自引:0,他引:1
在设定的絮凝条件下,以济南市水质净化一厂初沉池进水为试验水样,无机高分子絮凝剂聚合氯化铁铝(PFAC)和有机高分子絮凝剂聚丙烯酰胺(PAM)为试验药剂,浊度、COD、溶解氧等为测定指标,进行了一系列气动絮凝试验。试验结果表明,采用气动絮凝方式强化城市污水一级处理效果明显。单独投加25mg/L PFAC时,浊度、COD去除率分别为90%、78.5%,溶解氧增加230%;组合投加20mg/L PFAC+1.0mg/LPAM时,浊度、COD去除率分别为92.4%、78.6%,溶解氧增加246%。 相似文献
5.
6.
《现代化工》2016,(5)
采用纳米Fe_3O_4与聚合氯化铝(PAC)复配制备磁性复合絮凝剂MFPAC,利用MFPAC强化混凝-改性矿化垃圾吸附处理垃圾渗滤液。结果表明,MFPAC中适宜的前驱物质量比为m(Fe_3O_4)∶m(PAC)=1∶3,正交实验结果表明,m(Fe_3O_4)∶m(PAC)以及投药量对混凝效果有较为显著的影响,p H和沉淀时间对去除效果影响相对较小,MFPAC对COD和色度的去除效果均优于单独投加PAC,投加量为1.5 g/L时,COD和色度去除率分别达到62.6%和66.5%;采用焙烧法对矿化垃圾进行改性,利用改性矿化垃圾吸附MFPAC混凝出水,在焙烧温度为700℃,吸附剂投加量为40 mg/L的条件下,COD和氨氮的去除率分别为56.7%和68.4%;MFPAC混凝-矿化垃圾吸附联合工艺对垃圾渗滤液COD、色度和氨氮的去除率分别为83.8%、78.5%和74.3%。 相似文献
7.
8.
壳聚糖复合絮凝剂处理含油废水 总被引:1,自引:0,他引:1
壳聚糖复合絮凝剂处理含油废水,正交实验结果分析表明:pH值为7,PAM量为2mg/L,壳聚糖量为2mg/L时,对废水化学耗氧量(COD)去除率可达47.33%;pH值为7.PAM量为1mg/L,壳聚糖量为8mg/L时,对废水浊度处理得到较为满意的效果,浊度去除率可达91.73%。对浊度和COD去除率的影响因素主次顺序是:pH值〉PAM投加量〉搅拌时间〉壳聚糖投加量。 相似文献
9.
《水处理技术》2016,(2)
采用矿化垃圾吸附-Fenton-NaClO氧化联合深度处理垃圾渗滤液。吸附实验在矿化垃圾粒径为2 mm,用700℃焙烧改性的矿化垃圾作为吸附剂,投加量为60g/L、pH=9的条件下进行,COD和氨氮的去除率分别达到最大的53.15%和78.77%;吸附出水在初始pH为6、H_2O_2投加量为60 mmol/L、n(H_2O_2):n(Fe~(2+))为4:1、反应时间为75 min的条件下进行Fenton氧化,COD和氨氮的去除率分别达到最大的52.37%和11.5%;Fenton氧化出水在NaClO,投加量为60 mmol/L、pH为6、温度为50℃和反应时间为60 min的条件下进行NaClO氧化,NaClO对COD和氨氮的去除率分别达到最高的81.86%和98.96%,此时COD为78 mg/L,氨氮的质量农度为0.42mg/L,均可满足GB16889-2008规定的排放标准。 相似文献
10.
采用高锰酸钾与次氯酸钠复合预氧化与常规处理工艺联用对白石水库微污染水源水进行了中试研究。试验结果表明,该处理工艺对CODMn、浊度、色度均有较好的去除效果,出水CODMn低于3.0mg/L,浊度低于1.0NTU,色度低于5度。预氧化剂高锰酸钾投加量在0.30mg/L、次氯酸钠投加量在5.0mg/L时,就具有明显的助凝效果,沉后水的CODMn去除率为25%,浊度去除率为80%,色度去除率为85%。 相似文献
11.
采用电混凝-反渗透组合工艺处理渗滤液经膜生物反应器的出水,考察组合工艺的处理效果及电混凝作为RO进水预处理的可行性。结果表明,组合工艺出水COD和NH3-N、TP的质量浓度分别为100 mg/L和20、0.2 mg/L,去除率分别达到95%、90%、98%,可以满足GB 16889-2008的排放要求;出水电导率为355μS/cm,膜出水电导率与进水电导率的比大于0.94。电混凝工艺能够有效降低RO进水的COD、TP含量,明显地减缓膜结垢污染,改善膜的产水率,可以作为膜前预处理。 相似文献
12.
13.
以福建省某市处理规模为250 m3/d的中老龄垃圾填埋场渗滤液处理工程为例,介绍了水质均衡+两级A/O+超滤+纳滤+反渗透组合工艺在填埋场渗滤液处理中的应用情况。处理后出水COD≤30 mg/L、BOD5≤10 mg/L、NH3-N≤20 mg/L,满足《生活垃圾填埋场污染控制标准》(GB 16889—2008)中表2排放限值,且大大减少药剂投加成本。 相似文献
14.
《Desalination》2007,202(1-3):310-317
In this paper, the technical applicability of the vibratory shear-enhanced processing reverse osmosis (VSEPRO) membrane system for the treatment of stabilized leachate from the NENT landfill in Hong Kong was studied using both 99 and 96% NaCl rejection membranes. The performance of VSEPRO for NH3-N and COD removal was evaluated and compared to the performances of other individual and/or combined treatments from other studies. Without any pH adjustment, it was found that the rejection rates of VSEPRO were 96% for COD and 98% for NH3-N with initial COD and/or NH3-N concentrations of 8000 and 2620 mg/L, respectively. It was evident that pH adjustment of raw leachate to acidic conditions (pH 6.0) slightly improved the rejection rates for COD (97%) and NH3-N (99.6%). These results were satisfactory compared to other physicochemical treatments. It is important to note that the treatment of leachate using VSEPRO was able to meet the local effluent limit for COD of lower than 200 mg/L and for NH3-N of less than 5 mg/L. This result suggests that VSEPRO is technically applicable and appealing for the treatment of stabilized leachate. 相似文献
15.
厌氧/SBR/混凝沉淀耦合工艺处理垃圾渗滤液的研究 总被引:3,自引:0,他引:3
采用厌氧/SBR/混凝沉淀耦合工艺对城市垃圾渗滤液进行处理,确定厌氧、SBR法和混凝沉淀的最佳运行参数。结果表明,当进水COD=1720mg/L、NHTN=127.6mg/L时,通过该系统处理后,出水COD=148.4mg/L、NH3-N=12.2mg/L,COD总去除率达到91.2%,NH3-N去除率达90.4%,达到较好的去除有机物和脱氮效果。 相似文献
16.
采用微波-Fenton法,絮凝沉淀法联合强化处理工艺对垃圾渗滤液进行了处理研究,通过实验考察了不同工艺方法的最佳处理条件和处理结果。实验结果表明:将垃圾渗滤液稀释100倍,调节pH至3.0,在处理液中加入8 mL浓度为8 mmol·L-1的Fe2+溶液,1 mL H2O2,用功率为320 W微波加热6 min时,垃圾渗滤液的COD去除率为98.74%,但NH3-N的去除率较低,在此基础上进行微生物絮凝沉淀处理,垃圾渗滤液中的COD和NH3-N的含量分别为2 mg·L-1和0.039 mg·L-1,达到了污水排放标准。 相似文献
17.
18.
由于垃圾渗滤液COD、NH4-N浓度高,并且含有重金属等有毒污染物,通常,单纯的生物处理方式效果并不理想.高COD浓度的垃圾渗滤液经混凝沉淀后,调节pH=12,进行氨吹脱,经此预处理后的垃圾渗滤液,进行Fed-Batch Reactor(FBR)好氧生物处理,比较投加粉末活性碳(PAC)和不投加两种情况下对COD和NH4-N去除效果.当PAC投加量为2 g/L时,COD去除率达86 %,NH4-N去除率达26 %. 相似文献
19.
20.
气浮-混凝-Fenton氧化处理垃圾渗滤液动态模拟研究 总被引:1,自引:1,他引:0
采用气浮-混凝-Fenton氧化组合工艺对垃圾渗滤液进行处理。试验研究结果表明,最佳气浮条件:气水比为45~60mL/L、氧化石蜡皂用量为300mg/L、气浮时间为15min;最佳混凝条件:PAM投加量为9mg/L、PAC投加量为1100mg/L、pH值为5、搅拌强度为200r/min;最佳Fenton氧化条件:pH值为3,Fe2+投加量为0.04mol/L,n(H2O2)/n(Fe2+)为15,反应时间为90min。垃圾渗滤液经过气浮-混凝-Fenton氧化处理后COD、NH3-N得到了较好的去除,最终出水COD、NH3-N、TP可达《生活垃圾填埋场污染控制标准》(GB16889—2008)中的排放浓度限值。 相似文献