首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
An efficient, Bloch wave-based method is presented for simulation of high-resolution scanning confocal electron microscopy (SCEM) images. The latter are predicted to have coherent nature, i.e. to exhibit atomic contrast reversals depending on the lens defocus settings and sample thickness. The optimal defocus settings are suggested and the 3D imaging capabilities of SCEM are analyzed in detail. In particular, by monitoring average image intensity as a function of the probe focus depth, it should be possible to accurately measure the depth of a heavy-atom layer embedded in a light-element matrix.  相似文献   

2.
Einspahr JJ  Voyles PM 《Ultramicroscopy》2006,106(11-12):1041-1052
Confocal STEM is a new electron microscopy imaging mode. In a microscope with spherical aberration-corrected electron optics, it can produce three-dimensional (3D) images by optical sectioning. We have adapted the linear imaging theory of light confocal microscopy to confocal STEM and use it to suggest optimum imaging conditions for a confocal STEM limited by fifth-order spherical aberration. We predict that current or near-future microscopes will be able to produce 3D images with 1 nm vertical resolution and sub-Angstrom lateral resolution. Multislice simulations show that we will need to be cautious in interpreting these images, however, as they can be complicated by dynamical electron scattering.  相似文献   

3.
Scanning confocal electron microscopy (SCEM) offers a mechanism for three-dimensional imaging of materials, which makes use of the reduced depth of field in an aberration-corrected transmission electron microscope. The simplest configuration of SCEM is the bright-field mode. In this paper we present experimental data and simulations showing the form of bright-field SCEM images. We show that the depth dependence of the three-dimensional image can be explained in terms of two-dimensional images formed in the detector plane. For a crystalline sample, this so-called probe image is shown to be similar to a conventional diffraction pattern. Experimental results and simulations show how the diffracted probes in this image are elongated in thicker crystals and the use of this elongation to estimate sample thickness is explored.  相似文献   

4.
After the introduction of a corrector to compensate for the spherical aberration of a TEM and the acceptance of this new instrumentation for high-resolution CTEM (conventional transmission electron microscope) and STEM (scanning transmission electron microscope) by the electron microscopy community, a demand for even higher resolution far below 1A has emerged. As a consequence several projects around the world have been launched to make these new instruments available and to further push the resolution limits down toward fractions of 1A. For this purpose the so-called TEAM (transmission electron aberration-corrected microscope) has been initiated and is currently under development. With the present paper we give a detailed assessment of the stability required for the base instrument and the electric stability, the manufacturing precision, and feasible semi-automatic alignment procedures for a novel C(c)/C(s)-corrector in order to achieve aberration-free imaging with an information limit of 0.5A at an acceleration voltage of 200 kV according to the goals for the first TEAM instrument. This new aberration corrector, a so-called Achroplanat, in combination with a very stable high-resolution TEM leads to an imaging device with unprecedented resolving power and imaging properties.  相似文献   

5.
Tomography using a scanning transmission electron microscope (STEM) offers intriguing possibilities for the three-dimensional imaging of micron-thick, biological specimens and assemblies of nanostructures, where the image resolution is potentially limited only by plural elastic scattering in the sample. A good understanding of the relationship between material thickness and spatial resolution is required, with particular emphasis on the competition between beam divergence (a geometrical effect from the converged STEM probe) and beam spreading (an unavoidable broadening due to plural elastic scattering). We show that beam divergence dominates beam spreading for typical embedding polymers beyond the 100-nm thickness range and that minimization of this effect leads to enhanced spatial resolution. The problems are more pronounced in spherical-aberration-corrected instruments where the depth of field is shorter.  相似文献   

6.
Structural and compositional studies of nanomaterials of technological importance have been carried out using advanced electron microscopy methods, including aberration-corrected transmission electron microscopy (AC-TEM), AC-high angle annular dark field scanning TEM (AC-HAADF-STEM), AC-energy filtered TEM, electron-stimulated energy dispersive spectroscopy in the AC-(S)TEM and high-resolution TEM (HRTEM) with scanning tunneling microscopy (STM) holder. The AC-EM data reveal improvements in resolution and minimization in image delocalization. A JEOL 2200FS double-AC field emission gun TEM/STEM operating at 200 kV in the Nanocentre at the University of York has been used to image single metal atoms on crystalline supports in catalysts, grain boundaries in nanotwinned metals, and nanostructures of tetrapods. Joule heating studies using HRTEM integrated with an STM holder reveal in situ crystallization and edge reconstruction in graphene. Real-time in situ AC-HAADF-STEM studies at elevated temperatures are described. Dynamic in-column energy filtering in an AC environment provides an integral new approach to perform dynamic in situ studies with aberration correction. The new results presented here open up striking new opportunities for atomic scale studies of nanomaterials and indicate future development directions.  相似文献   

7.
扫描透射电子显微术(STEM)的原子序数衬度(Z-contrast)像具有分辨率高、对化学组成敏感以及图像直观可直接解释等优点。Z-衬度像成像方法是近年来在国外兴起的一种新型的高分辨成像方法,本文主要介绍了扫描透射电子显微术(STEM)的原子序数衬度像(Z-衬度像)的成像原理及方法,并指出了在材料科学研究中Z-衬度像的突出特点及应用前景。  相似文献   

8.
In a simulation study, we found that focal depth extension using a hollow cone-shaped probe with an annular aperture is useful for three-dimension (3D) tomography of aberration-corrected scanning transmission electron microscopy (STEM). Our calculations showed that, for 200 kV STEM, a sub-angstrom sized probe could extend the focal depth from a few to more than several tens nm. We also examined the influence of obstructing bridges, including actual fabricated annular apertures, on focused probe intensity distribution. We found that, to avoid any distortion of probe intensity, the width of the bridges should be narrow. Quantitative evaluation showed that the ratio of obstructing area of the bridges to the area of the annular slit should be less than 0.11.  相似文献   

9.
We study atomic-resolution annular electron energy-loss spectroscopy (AEELS) in scanning transmission electron microscopy (STEM) imaging with experiments and numerical simulations. In this technique the central part of the bright field disk is blocked by a beam stop, forming an annular entry aperture to the spectrometer. The EELS signal thus arises only from electrons scattered inelastically to angles defined by the aperture. It will be shown that this method is more robust than conventional EELS imaging to variations in specimen thickness and can also provide higher spatial resolution. This raises the possibility of lattice resolution imaging of lighter elements or ionization edges previously considered unsuitable for EELS imaging.  相似文献   

10.
This work quantitatively evaluates the contrast in phase contrast images of thin vermiculite crystals recorded by TEM and aberration-corrected bright-field STEM. Specimen movement induced by electron irradiation remains a major problem limiting the phase contrast in TEM images of radiation-sensitive specimens. While spot scanning improves the contrast, it does not eliminate the problem. One possibility is to utilise aberration-corrected scanning transmission electron microscopy (STEM) with an Ångstrom-sized probe to illuminate the sample, and thus further reduce irradiation-induced specimen movement. Vermiculite is relatively radiation insensitive in TEM to electron fluences below 100,000 e2 and this is likely to be similar for STEM although different damage mechanisms could occur. We compare the performance of a TEM with a thermally assisted field emission electron gun (FEG) and charge coupled device (CCD) image capture to the performance of STEMs with spherical aberration correction, cold field emission electron sources and photomultiplier tube image capture at a range of electron fluences and similar illumination areas. We show that the absolute contrast of the phase contrast images obtained by aberration-corrected STEM is better than that obtained by TEM. Although the STEM contrast is higher, the efficiency of collection of electrons in bright field STEM is still much less than that in bright field TEM (where for thin samples virtually all the electrons contribute to the image), and the SNR of equivalent STEM images is three times lower. This is better than expected, probably due to the absence of a frequency dependent modulation transfer function in the STEM detection system. With optimisation of the STEM bright field collection angles, the efficiency may approach that of bright field TEM, and if reductions in beam-induced specimen movement are found, STEM could surpass the overall performance of TEM.  相似文献   

11.
Environmental scanning electron microscopy (ESEM) enables wet samples to be observed without potentially damaging sample preparation through the use of partial water vapour pressure in the microscope specimen chamber. However, in the case of latices in colloidal state or microorganisms, samples are not only wet, but made of objects totally submerged in a liquid phase. In this case, under classical ESEM imaging conditions only the top surface of the liquid is imaged, with poor contrast, and possible drifting of objects. The present paper describes experiments using a powerful new Scanning Transmission Electron Microscopy (STEM) imaging system, that allows transmission observations of wet samples in an ESEM. A special device, designed to observe all sorts of objects submerged in a liquid under annular dark-field imaging conditions, is described. Specific features of the device enable to avoid drifting of floating objects which occurs in the case of a large amount of water, thus allowing slow-scan high-definition imaging of particles with a diameter down to few tens of nm. The large potential applications of this new technique are then illustrated, including the imaging of different nano-objects in water. The particular case of grafted latex particles is discussed, showing that it is possible to observe details on their surface when submerged in water. All the examples demonstrate that images acquired in wet STEM mode show particularly good resolution and contrast, without adding enhancing contrast objects, and without staining.  相似文献   

12.
The optimal lens parameters for incoherent imaging using third and fifth-order aberration-corrected electron microscopes are derived analytically. We propose simple models for the point spread function (PSF) and transfer function that give analytic formulae for the lateral resolution and depth resolution. We also derive an analytic formula for the contrast transfer function (CTF) in three dimensions and show that depth sectioning has an information limit equivalent to tomography with a missing cone of 90 degrees minus the aperture angle.  相似文献   

13.
The techniques of reflection electron microscopy (REM) using TEM instruments and scanning reflection electron microscopy (SREM) using STEM instruments have been explored as means for the observation of surface structure with high spatial resolution, better than 1 nm in each case. Under the ordinary environment of a commercial TEM instrument, we have studied the contrast in REM images of atomic steps and made comparison with the calculated results from the multi-slice dynamical diffraction theory. Comparison has also been made between the REM images of defects and the calculated images based on the column approximation. The influence of surface resonances on the contrast has been investigated. By SREM performed in a modified HB5 STEM with attached high vacuum preparation chamber, we have observed the formation of periodically distributed Pd particles on the surface of cleaved MgO.  相似文献   

14.
The first part of this paper is devoted to physics, to explain high‐angle annular dark‐field scanning transmission electron microscopy (HAADF‐STEM) imaging and to interpret why HAADF‐STEM imaging is incoherent, instructing a strict definition of interference and coherence of electron waves. Next, we present our recent investigations of InGaN/GaN multiple quantum wells and AlGaN/GaN strained‐layer superlattice claddings in GaN‐based violet laser diodes, which have been performed by HAADF‐STEM and high‐resolution field‐emission gun scanning electron microscopy.  相似文献   

15.
The size distribution of second phase precipitates is frequently determined using conventional transmission electron microscopy (CTEM). However, other techniques, which present different advantages, can also be used for this purpose. In this paper, we focus on high angle annular dark field (HAADF) in TEM and scanning TEM (STEM) in scanning electron microscopy (SEM) imaging modes. The mentioned techniques will be first described, then compared to more conventional ones for the measurement of carbides size distribution in two FeCV and FeCVNb model alloys. This comparative study shows that STEM in SEM, a technique much easier to undertake compared to TEM, is perfectly adapted for size distribution measurements of second phase particles, with sizes ranging between 5 and 200 nm in these systems.  相似文献   

16.
Yu Z  Batson PE  Silcox J 《Ultramicroscopy》2003,96(3-4):275-284
The introduction of an experimental black level may introduce unintended artifactual details into high-resolution annular dark field scanning transmission electron microscopy (ADF-STEM) lattice images. This article presents the multislice simulation results of such possible situations. Three simulated scanning transmission electron microscopy (STEM) probes of sizes 0.8, 1.2 and 2.0 A are scanned on the surface of a <1;10> oriented Si/Ge crystal. The simulation results suggest that high-frequency artifact peaks will appear in the power spectra when an artificial black level clips the lowest (background) signal. The lowest signal in an ADF-STEM image decreases as the incident probe shrinks in size. Therefore, care must be taken when interpreting the resolution limit of the microscope from images taken with nonzero black level setting, especially in case of sub-A microscope. The simulation result is compared with an experimental image and they agree with each other. The analysis suggests that aberration corrected STEM provide sensitive low level detail.  相似文献   

17.
Imaging internal features of whole, unfixed bacteria   总被引:1,自引:0,他引:1  
Wet scanning-transmission electron microscopy (STEM) is a technique that allows high-resolution transmission imaging of biological samples in a hydrated state, with minimal sample preparation. However, it has barely been used for the study of bacterial cells. In this study, we present an analysis of the advantages and disadvantages of wet STEM compared with standard transmission electron microscopy (TEM). To investigate the potential applications of wet STEM, we studied the growth of polyhydroxyalkanoate and triacylglycerol carbon storage inclusions. These were easily visible inside cells, even in the early stages of accumulation. Although TEM produces higher resolution images, wet STEM is useful when preservation of the sample is important or when studying the relative sizes of different features, since samples do not need to be sectioned. Furthermore, under carefully selected conditions, it may be possible to maintain cell viability, enabling new types of experiments to be carried out. To our knowledge, internal features of bacterial cells have not been imaged previously by this technique.  相似文献   

18.
Aberration correction of the scanning transmission electron microscope (STEM) has made it possible to reach probe sizes close to 1 Å at 60 keV, an operating energy that avoids direct knock-on damage in materials consisting of light atoms such as B, C, N and O. Although greatly reduced, some radiation damage is still present at this energy, and this limits the maximum usable electron dose. Elemental analysis by electron energy loss spectroscopy (EELS) is then usefully supplemented by annular dark field (ADF) imaging, for which the signal is larger. Because of its strong Z dependence, ADF allows the chemical identification of individual atoms, both heavy and light, and it can also record the atomic motion of individual heavy atoms in considerable detail. We illustrate these points by ADF images and EELS of nanotubes containing nanopods filled with single atoms of Er, and by ADF images of graphene with impurity atoms.  相似文献   

19.
We report a local crystal structure analysis with a high precision of several picometers on the basis of scanning transmission electron microscopy (STEM). Advanced annular dark-field (ADF) imaging has been demonstrated using software-based experimental and data-processing techniques, such as the improvement of signal-to-noise ratio, the reduction of image distortion, the quantification of experimental parameters (e.g., thickness and defocus) and the resolution enhancement by maximum-entropy deconvolution. The accuracy in the atom position measurement depends on the validity of the incoherent imaging approximation, in which an ADF image is described as the convolution between the incident probe profile and scattering objects. Although the qualitative interpretation of ADF image contrast is possible for a wide range of specimen thicknesses, the direct observation of a crystal structure with deep-sub-angstrom accuracy requires a thin specimen (e.g., 10 nm), as well as observation of the structure image by conventional high-resolution transmission electron microscopy.  相似文献   

20.
This work addresses two major issues relating to Helium Ion Microscopy (HeIM). First we show that HeIM is capable of solving the interpretation difficulties that arise when complex three-dimensional structures are imaged using traditional high lateral resolution techniques which are transmission based, such as scanning transmission electron microscopy (STEM). Secondly we use a nano-composite coating consisting of amorphous carbon embedded in chromium rich matrix to estimate the mean escape depth for amorphous carbon for secondary electrons generated by helium ion impact as a measure of HeIM depth resolution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号