首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The preparation and performance of a multilayered stationary phase for open tubular anion exchange chromatography in relatively large bore (75 microm diameter) columns are described. The inner surface of a fused-silica capillary tube is coated with up to 25 successive porous polymeric layers formed by condensation polymerization of a primary amine with a diepoxide. Each layer of the anion exchange stationary phase consists of copolymer of methylamine (MA) and 1,4-butanedioldiglycidyl ether (BDDE). The polymer layers are sufficiently porous or permeable; each successive layer of the stationary phase incrementally increases the observed column capacity and chromatographic performance in the open tubular mode. Even though the column inner diameter is far from optimum for open tubular liquid chromatography, we demonstrate the baseline separation of a suite of inorganic anions (F-, Cl-, NO2-, Br-, NO3-) in a 5 m x 75 microm column coated with 25 layers of the anion exchange polymer using 1 mM KOH eluent and suppressed contactless conductometric detection at a flow rate of 1 microL/min (operating pressure of approximately 1 bar) with a plate count of >30,000. Strategies for construction of microsuppressor devices used in open tubular ion chromatography are discussed.  相似文献   

2.
A chip-based capillary electrophoresis/mass spectrometry (CE/MS) system is described for the CE separation and on-line electrospray detection of carnitine and selected acylcarnitines from mixtures of analytical standards as well as extracts of fortified human urine. Chip-based CE/MS experiments in two different laboratories were carried out using a triple-quadrupole mass spectrometer and a quadrupole time-of-flight (QTOF) mass spectrometer, respectively. The glass chips used with both systems were comparably equipped with a microfabricated capillary electrophoresis (CE) channel but with different electrosprayers. The quadrupole chip-based CE/MS experiments employed a miniature coupled microsprayer, which allowed coupling of the microelectrospray process via a micro liquid junction at the exit of the CE capillary channel. Selected ion monitoring (SIM) CE/MS experiments were employed for all of the quadrupole CE/MS work. The QTOF CE/MS full-scan single MS and MS/MS experiments were carried out in another laboratory using accurate mass measurement TOF mass spectrometry techniques. The electrospray process that was employed with the QTOF system differed in that an inserted nanoelectrospray capillary needle was carefully affixed into a flat-bottomed hole that was aligned with the CE channel exit orifice. SIM CE/MS using the described quadrupole system provided acceptable ion current electropherograms from fmole levels from analytical standard solutions of carnitine and acylcarnitines that were manually injected (loaded) onto the chip. In addition, the corresponding electropherograms for human urine fortified with the target carnitine and acylcarnitines at a 10-20 microg/mL (35-124 microM) level were obtained via SIM CE/MS techniques. The measured CE separation efficiency for the SIM CE/MS electropherograms was determined to be 2860 plates (peak width at half-height method or N = 5.54(T/WO.5(2)), and carnitine and three acylcarnitines were separated in less than 48 s. In contrast, using quadrupole-TOF technologies, the same samples could be diluted by a factor of 2-4 to obtain a comparable detector response for the target compounds. In the full-scan, single mass analyzer mode (m/z 150-500), the CE separation efficiency was measured to be 2600 plates, but mass measurement accuracy was less than 5.0 ppm for the quaternary cations. In the CE/MS/MS mode, full-scan collision-induced dissociation (CID) mass spectra were obtained with a mass accuracy of < or =10 ppm for the higher mass ions and < or =27 ppm for the lower mass product ions. These results demonstrate the feasibility for on-chip CE separation and electrospray mass spectrometric detection for these important compounds in synthetic mixtures, as well as in human urine extracts.  相似文献   

3.
The separation of the glycoforms of erythropoietin (EPO) by capillary electrophoresis (CE) was recently published as a monograph by the European Pharmacopoeia (European Pharmacopoeia 4 2002, 1316, 1123-1128). Although the experimental CE conditions employed a background electrolyte containing additives suitable for on-line UV-absorption detection, they were not appropriate for on-line mass spectrometry (MS) detection. In this work, an attempt was made to investigate experimental conditions employing volatile electrolyte systems to achieve the separation and characterization of EPO glycoforms using CE and ESI-MS methodologies. The influence of several operating conditions, such as the coating of the internal walls of the capillary as well as the composition, concentration, and the pH of the separation buffer were investigated. The results demonstrated that when the internal walls of the capillaries were permanently coated with Polybrene and a buffer electrolyte containing 400 mM of HAc-NH4Ac (acetic acid-ammonium acetate), pH 4.75, was used, a significantly reproducible separation was achieved for EPO glycoforms. Intact EPO was characterized by two mass spectrometry techniques: electrospray ionization (ESI-MS) and matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF-MS). The data demonstrated that MALDI-TOF-MS provided a good approximation to an average molecular mass of the EPO molecule. However, it was still necessary to carry out further separation of the intact EPO glycoforms in order to obtain molecular mass information when ESI-MS was used.  相似文献   

4.
Different macroporous, monolithic capillary columns were prepared to separate various bile acid mixtures through capillary electrochromatography (CEC) at high efficiency. These columns are shown to be ideally suitable for coupling to an electrospray ionization/ion trap mass spectrometer. Detection and structural identification of different bile acid derivatives in either the positive- or negative-ion mode necessitated column technologies with different polarities and the capabilities of a reversed electroosmotic flow. High column efficiencies (610,000 theoretical plates/meter for glycocholic acid in normal-phase separation) were preserved in the coupling to mass spectrometry (MS), with the detection limits of approximately 40 femtomole (for cholic acid) and identification through CEC/MS/MS.  相似文献   

5.
Chang SY  Yeung ES 《Analytical chemistry》1997,69(13):2251-2257
Mass spectrometry (MS) is usually coupled on-line with capillary electrophoresis (CE) to analyze biomolecules by using electrospray ionization or continuous-flow fast-atom bombardment. We present a new design for laser vaporization/ionization time-of-flight mass spectrometry. CE, with its low flow rate (<1 μL/min), is highly compatible with MS, even if the total column effluent is introduced directly. A UV laser is used to vaporize and ionize the solution eluting from the column. There is no need to have a makeup solvent. Using this system, we have analyzed a group of amines and peptides. The concentration detection limit of serotonin is in the 10(-)(7) M level. The separation and identification of an amine mixture by CE/MS demonstrates the complementary nature of the information.  相似文献   

6.
An improved vacuum deposition interface for coupling capillary electrophoresis with MALDI-TOF MS has been developed. Liquid samples consisting of analyte and matrix were deposited on a moving tape in the evacuated source chamber of a TOF mass spectrometer, enabling 24 h of uninterrupted analysis. The vacuum deposition procedure was compared with the dried-droplet method, and it was found that vacuum deposition generated significantly more reproducible signal intensity, eliminating the need for "sweet spot" searching. A concentration detection limit in the low-nanomolar range has been achieved with a low-attomole amount of sample consumed per spectrum. In addition, ion suppression caused by hydrophobicity differences in the analytes was reduced. To minimize ion suppression further, separation prior to MALDI MS analysis was employed. The performance of capillary electrophoresis (CE)-MALDI-TOF MS using the vacuum deposition interface was evaluated with a peptide mixture injected at low-femtomole levels. All peptides were baseline resolved with separation efficiencies in the range of 250000-400000 plates/m (2-3-s band half-width), demonstrating the high separation efficiency of the CE-MALDI MS coupling. A fast (approximately 40 s) CE separation of a mixture of angiotensins was found to reduce significantly ion suppression and enable trace level detection. It was also shown, for the analysis of an enolase digest, that sequence coverage of 65% was obtained using CE separation compared to 52% using step-elution solid-phase extraction and 44% in the control experiment using an unseparated mixture.  相似文献   

7.
Feng YL  Zhu J 《Analytical chemistry》2006,78(18):6608-6613
A new on-line capillary zone electrophoresis/mass spectrometry (CZE/MS), constant pressure-assisted electrokinetic injection (PAEKI), for the analysis of negatively charged nucleotides is reported. PAEKI uses an applied pressure to counterbalance the reverse electroosmotic flow in the capillary column during sample injection, while taking advantage of the field amplification in the sample medium. At balance, the running buffer in the column is stationary, permitting potentially unlimited injection time, and hence unlimited sample enrichment power. The ability of PAEKI to maintain a narrow sample zone over a long injection time seems to be a result of the formation of a high ion concentration band at the boundary of the two media due to rapid deceleration of the migrating ions at the boundary. The injected amount of analytes proved to be linearly proportional to both the field amplification factor, which is expressed as the ratio of resistivities of sample medium to running buffer, and the injection time, which extended up to 1200 s in CZE/MS and 3600 s in CZE/UV. For a 300-s on-line PAEKI injection in CZE/MS, 3 orders of magnitude sample enhancement (5000-fold enrichment) could be observed for the four single nucleotides without compromising separation efficiency and peak shape, and an achievement of detection limits between 0.04 and 0.07 ng/mL. With appropriate sample cleanup, PAEKI can be used in the analysis of single nucleotides in enzyme-digested DNA.  相似文献   

8.
Although several designs have been advanced for coupling sample enrichment devices to a sheathless electrospray ionization-mass spectrometry (MS) interface on a capillary electrophoresis (CE) column, most of these approaches suffer from difficulties in fabrication, and the CE separation efficiency is degraded as a result of the presence of coupling sleeves. We have developed a design that offers significant improvements in terms of ease of fabrication, durability, and maintenance of the integrity of the CE-separated analyte zones. Capillaries with different inside and outside diameters were evaluated to optimize the performance of the CE-MS system, resulting in a mass limit of detection of 500 amol for tandem MS analysis of a standard peptide using a 20-microm-i.d. capillary. The improved design incorporates an efficient method to preconcentrate a sample directly within the CE capillary followed by its electrophoretic separation and detection using a true zero dead-volume sheathless CE-MS interface. Testing of this novel CE-MS system showed its ability to characterize proteomic samples such as protein digests, in-gel-digested proteins, and hydrophobic peptides as well as to quantitate ICAT-labeled peptides.  相似文献   

9.
X Jin  J Kim  S Parus  D M Lubman  R Zand 《Analytical chemistry》1999,71(16):3591-3597
The development of a system capable of the speed required for on-line capillary electrophoresis-tandem mass spectrometry (CE-MS/MS) of tryptic digests is described. The ion trap storage/reflectron time-of-flight (IT/reTOF) mass spectrometer is used as a nonscanning detector for rapid CE separation, where the peptides are ionized on-line using electrospray ionization (ESI). The ESI produced ions are stored in the ion trap and dc pulse injected into the reTOF-MS at a rate sufficient to maintain the separation achieved by CE. Using methodology generated by software and hardware developed in our lab, we can produce SWIFT (Stored Waveform Inverse Fourier Transform) ion isolation and TICKLE activation/fragmentation voltage waveforms to generate MS/MS at a rate as high as 10 Hz so that the MS/MS spectra can be optimized on even a 1-2 s eluting peak. In CE separations performed on tryptic digests of dogfish myelin basic protein (MBP) where eluting peaks 4-8 s wide are observed, it is demonstrated that an acquisition rate of 4 Hz provides > 20 spectra/peak and is more than sufficient to provide optimized MS/MS spectra of each of the eluting peaks in the electropherogram. The detailed structural analysis of dogfish MBP including several posttranslational modifications using CE-MS and CE-MS/MS is demonstrated using this method with < 10 fmol of material consumed.  相似文献   

10.
J Bao  SN Krylov 《Analytical chemistry》2012,84(16):6944-6947
Kinetic capillary electrophoresis (KCE) is a toolset of homogeneous affinity methods for studying kinetics of noncovalent binding. Sensitive KCE measurements are typically done with fluorescence detection and require a fluorescent label on a smaller-sized binding partner. KCE with fluorescence detection is difficult to use for study of protein-small molecule interactions since labeling small molecules is cumbersome and can affect binding. A combination of KCE with mass-spectrometry (KCE-MS) has been recently suggested for label-free studies of protein-small molecule interactions. The major obstacle for studies by KCE-MS is a buffer mismatch between KCE and MS; MS requires volatile buffers while KCE of protein-ligand interactions is always run in near-physiological buffers. Here we asked a simple question: can protein-ligand interactions be studied with KCE in a volatile buffer? We compared three volatile buffers (ammonium acetate, ammonium bicarbonate, and ammonium formate) with a near-physiological buffer (Tris-acetate) for three protein-ligand pairs. The volatile buffers were found not to significantly affect protein-ligand complex stability; moreover, when used as CE run buffers, they facilitated good-quality separation of free ligands from the protein-ligand complexes. The use of volatile buffers instead of Tris-acetate in detection of small molecules by MS improved the detection limit by approximately 2 orders of magnitude. These findings prove the principle of "volatile" KCE, which can be easily coupled with MS to facilitate label-free kinetic studies of protein-small molecule interactions.  相似文献   

11.
A polymeric microfluidic chip for CE/MS determination of small molecules   总被引:4,自引:0,他引:4  
A polymeric microfluidic chip made of Zeonor 1020 was fabricated using conventional embossing techniques to perform capillary electrophoresis for selected ion monitoring and selected reaction monitoring mass spectrometric detection of small molecules. A silicon master was microfabricated using photolithographic and dry etching processes. The microfluidic channel was embossed in the plastic from a silicon master. The embossed chip was thermally bonded with a Zeonor 1020 cover to form an enclosed channel. This channel (60-microm width, 20-microm depth, 2.0- and 3.5-cm length) provided capillary electrophoresis (CE) separation of polar small molecules without surface treatment of the polymer. A microsprayer coupled via a microliquid junction provided direct electrospray mass spectrometric detection of CE-separated components. An electric field of 0.5-2 kV/cm applied between the microsprayer and a separation buffer reservoir produced a separation of carnitine, acylcarnitine, and butylcarnitine with separation efficiencies ranging from 1,650 to 18,000 plates. Injection quantities of 0.2 nmol of these compounds produced a separation of the targeted polar small molecules without surface treatment of the polymer-abundant ion current signals and baseline separation of these compounds in less than 10 s. These results suggest the feasibility of polymeric chip-based devices for ion spray CE/MS applications.  相似文献   

12.
Determination of iodide in seawater by ion chromatography   总被引:1,自引:0,他引:1  
Ito K 《Analytical chemistry》1997,69(17):3628-3632
A simple and highly sensitive ion chromatographic method with UV detection was developed for iodide (I(-)) in seawater. A high-capacity anion-exchange resin with polystyrene-divinylbenzene matrix was used for both preconcentration and separation of iodide. Iodide in artificial seawater (salinity, 35‰) was trapped quantitatively (98.8 ± 0.6%) without peak broadening on a preconcentrator column and was separated with 0.35 M NaClO(4) + 0.01 M phosphate buffer (pH 6.1). On the other hand, the major anions in seawater, chloride and sulfate ions, were partially trapped (5-20%) and did not interfere in the determination of I(-). The detection limit for I(-) was 0.2 μg/L for 6 mL of artificial seawater. The present method was applied to determination of I(-) (ND - 18.3 μg/L) and total inorganic iodine (I(-) + IO(3)(-) - I, 50.0-52.7 μg/L) in seawater samples taken near Japan.  相似文献   

13.
We describe a method, based on pressure-assisted capillary electrophoresis coupled to electrospray ionization mass spectrometry (PACE/ESI-MS), that allows the simultaneous and quantitative analysis of multivalent anions, such as citrate isomers, nucleotides, nicotinamide-adenine dinucleotides, and flavin adenine dinucleotide, and coenzyme A (CoA) compounds. Key to the analysis was using a noncharged polymer, poly(dimethylsiloxane), coated to the inner surface of the capillary to prevent anionic species from adsorbing onto the capillary wall. It was also necessary to drive a constant liquid flow toward the MS by applying air pressure to the inlet capillary during electrophoresis to maintain a conductive liquid junction between the capillary and the electrospray needle. Although theoretical plates were inferior to those obtained by CE/ESI-MS using a cationic polymer-coated capillary, the PACE/ESI-MS method improved reproducibility and sensitivity of these anions. Eighteen anions were separated by PACE and selectively detected by a quadrupole mass spectrometer with a sheath-flow electrospray ionization interface. The relative standard deviations (n = 6) of the method were better than 0.6% for migration times and between 1.4% and 6.2% for peak areas. The detection limits for these species were between 0.4 and 3.7 micromol/L with pressure injection of 50 mbar for 30 s (30 nL), that is, mass detection limits calculated in the range from 12 to 110 fmol at a signal-to-noise ratio of 3. The utility of the method was demonstrated by analysis of citrate isomers, nucleotides, dinucleotides, and CoA compounds extracted from Bacillus subtilis cells.  相似文献   

14.
A sulfonated methacrylate monolithic polymer has been synthesized inside fused-silica capillaries of diameters 50-533-microm i.d. and coated with 65-nm-diameter fully functionalized quaternary ammonium latex particles (AS18, Dionex Corp.) to form an anion-exchange stationary phase. This stationary phase was used for ion-exchange capillary electrochromatography of inorganic anions in a 75-microm-i.d. capillary with Tris/perchlorate electrolyte and direct UV detection at 195 nm. Seven inorganic anions (bromide, nitrate, iodide, iodate, bromate, thiocyanate, chromate) could be separated over a period of 90 s, and the elution order indicated that both ion exchange and electrophoresis contributed to the separation mechanism. Separation efficiencies of up to 1.66 x 10(5) plates m(-1) were achieved, and the monoliths were stable under pressures of up to 62 MPa. Another latex-coated monolith in a 250-microm-i.d. capillary was used for in-line preconcentration by coupling it to a separation capillary in which the EOF had been reversed using a coating of either a cationic polymer or cationic latex particles. Several capillary volumes of sample were loaded onto the preconcentration monolith, and the analytes (inorganic anions) were then eluted from the monolith with a transient isotachophoretic gradient before being separated by electrophoresis in the separation capillary. Linear calibration curves were obtained for aqueous mixtures of bromide, nitrite, nitrate, and iodide. Recoveries of all analytes except iodide were reduced significantly when the sample matrix contained high levels of chloride. The preconcentration method was applied to the determination of iodide in open ocean water and provided a limit of detection of 75 pM (9.5 ng/L) calculated at a signal-to-noise ratio of 3. The relative standard deviation for migration time and peak area for iodide were 1.1 and 2.7%, respectively (n = 6). Iodide was eluted as an efficient peak, yielding a separation efficiency of 5.13 x 10(7) plates m(-1). This focusing was reproducible for repeated analyses of seawater.  相似文献   

15.
A chip-based capillary electrophoresis/mass spectrometry (CE/MS) system is described for the on-chip separation and coupled electrospray detection of selected small drug molecule compounds. These studies include the quantitative determination of carnitine and acetylcarnitine in analytical standard solutions as well as imipramine and desipramine in fortified human plasma samples. A clinical human plasma sample was also analyzed following the normal administration of desipramine to a volunteer, and the parent drug was determined using the described chipbased CE/MS technique. In each instance, stable isotope-incorporated internal standards were used. The chip-based CE system was microfabricated from glass and coupled to a micro ion spray device constructed in-house. The atmospheric pressure ionization system employed in this work was a PE Sciex API III tandem triple quadrupole system operated in the selected ion monitoring (SIM) mode. The results from the work reported here demonstrate the feasibility for carrying out rapid (30 s) chipbased quantitative CE/MS determinations of samples containing small-molecule compounds. Using SIM CE/ MS techniques, the described API III quadrupole system provided acceptable ion current electropherograms from subpicomole levels of the targeted compounds loaded onto the chip. The corresponding electropherograms for the standard solution of carnitines at the 1-500 microg/mL level were obtained via SIM CE/MS techniques (R2 > 0.99). In addition, analyses of fortified samples of imipramine desipramine were measured relative to their corresponding d3 internal standards to obtain calibration curves ranging from 5 to 500 microg/mL in human plasma (R2 > 0.99). The intra-assay precision ranged from 4.1 to 7.3% RSD. The intra-assay accuracy ranged from 94.0 to 104%. These results demonstrate the feasibility for on-chip CE separation and electrospray mass spectrometric determination in applications for bioanalytical measurements for these important compounds in synthetic mixtures and human plasma extracts.  相似文献   

16.
Capillary electrophoresis-mass spectrometry (CE-MS) is still widely regarded as an emerging tool in the field of metabolomics and metabolite profiling. A major reason for this is a reported lack of sensitivity of CE-MS when compared to gas chromatography-mass spectrometry GC/MS and liquid chromatography-mass spectrometry. The problems caused by the lack of sensitivity are exacerbated when CE is coupled to Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), due to the relatively low data acquisition rate of FT-ICR MS. Here, we demonstrate the use of an online CE sample preconcentration method that uses a combination of pH-mediated stacking and transient isotachophoresis, coupled with FT-ICR MS to improve the overall detection of cationic metabolites in the bacterium Desulfovibrio vulgaris Hildenborough. This method showed a significant increase in signal-to-noise ratio when compared to CE normal sample stacking, while providing good separation efficiency, reproducibility, and linearity. Detection limits for selected amino acids were between 0.1 and 2 microM. Furthermore, FT-ICR MS detection consistently demonstrated good mass resolution and sub-ppm mass accuracy.  相似文献   

17.
Ren J  Huang X 《Analytical chemistry》2001,73(11):2663-2668
Highly sensitive and universal indirect chemiluminescence detection for capillary electrophoresis of cations was described. This novel method is based on use of the ultrasensitive cobalt(II) as a probe ion in the running buffer. A strong and stable background chemiluminescent signal can be generated by the luminol-hydrogen peroxide reaction catalyzed by cobalt(II) ion. Displacement of the cobalt(II) probe ion in the running buffer by a migrating sample cation results in a quantifiable decrease in the background signal. The conditions for electrophoresis and the chemiluminescent reaction were systematically investigated using a commercial capillary electrophoresis instrument with an in-house-built chemiluminescence detector. Under the optimal conditions, the detection limits of the concentration for manganese(II), cadmium(II), nickel(II), lead(II), and 14 lanthanides were (3.0-6.0) x 10(-9) mol/L (S/N = 3), which was approximately 3 orders of magnitude better than indirect UV detection and 2 orders better than indirect laser-induced fluorescent detection. A mixture of 18 metal ions including 14 lanthanides was efficiently separated within 3.5 min using lactate to partially complex the metal ions. Our data demonstrated that CE with indirect CL detection was a powerful and universal tool for analysis of inorganic and organic cations.  相似文献   

18.
Moini M 《Analytical chemistry》2001,73(14):3497-3501
A split-flow capillary electrophoresis electrospray ionization mass spectrometry (CE/ESI-MS) interface is introduced, in which the electrical connection to the CE capillary outlet is achieved by diverting part of the CE buffer out of the capillary through an opening near the capillary outlet. The CE buffer exiting the opening contacts a sheath metal tube which acts as the CE outlet/ESI shared electrode. In cases in which the ESI source uses a metal needle, the voltage contact to the CE buffer is achieved by simply inserting the outlet of the CE capillary, which contains an opening, into the existing ESI needle (thereby greatly simplifying the CE to MS interfacing). As a result of the concentration-sensitive nature of ESI, splitting a small percentage of the CE flow has minimal effect on the sensitivity of detection. In addition, because the liquid is flowing through the opening and out of the capillary, there is no dead volume associated with this interface. Moreover, bubble formation due to redox reactions of water at the electrode does not effect CE/ESI-MS performance, because the actual metal/liquid contact occurs outside of the CE capillary. The sensitivity associated with a sheathless CE/MS interface, the ease of fabrication, universality, and lack of any dead volume make this design a superior CE/ESI-MS interface. The performance of this interface is demonstrated by analyses of a peptide standard and a protein digest using a variety of capillary dimensions.  相似文献   

19.
The use of histidine as a protein digestion buffer followed by isoelectric trapping separations using "membrane separated wells for isoelectric focusing and trapping" (MSWIFT) and mass spectrometry (MS) analysis is described. Tryptic digestion of bovine serum albumin (BSA) performed in histidine buffered solutions yields similar amino acid sequence coverage values to those obtained using ammonium bicarbonate buffer. Time course studies suggest that histidine buffers provide faster migration of peptides from the loading compartment compared to digestions prepared in ammonium bicarbonate due to differences in conductivities of the two buffers. In addition, this sample preparation method and MSWIFT separations have been coupled with capillary electrophoresis (CE) and matrix-assisted laser desorption ionization-mass spectrometry (MALDI-MS) as an alternative separation approach for proteomic studies. Tryptic peptides of ribosomal proteins in histidine are fractionated using MSWIFT followed by CE-MALDI-MS, which further illustrates the ability to couple fractions from a pI based separation device to CE-MS. Specifically, two-dimensional CE-MS plots provide a direct correlation between the numbers of basic residues within the peptide sequence displayed in charge-state trend lines. Combining MSWIFT and CE-MS provides added information regarding peptide sequence, specifically pI and in-solution charge state. Post-translational modifications can also be identified using this method.  相似文献   

20.
New phosphorylated microbial metabolites referred to as phosphoantigens activate immune responses in humans. Although these molecules have leading applications in medical research, no direct method allows their rapid and unambiguous structural identification. Here, we interfaced online HPAEC (high performance anion-exchange chromatography) with ESI-ITMS (electrospray ionization ion trap mass spectrometry) to identify such pyrophosphorylated molecules. A self-regenerating anion suppressor located upstream of electrospray ionization enabled the simultaneous detection of pyrophosphoester by conductimetry, UV and MS. By HPAEC-ITMS and HPAEC-ITMS2, a single run permitted characterization of reference phosphoantigens and of related structures. Although all compounds were resolved by HPAEC, MS enabled their detection and identification by [M-H]- and fragment ions. Isobaric phosphoantigen analogues were also separated by HPAEC and distinguished by MS2. The relevance of this device was demonstrated for phosphoantigens analysis in human urine and plasma. Furthermore, identification of natural phosphoantigens by automatically generated 2D mass spectra from nano-ESI-ITMS is presented. This last technique permits the simultaneous performance of molecular screening of natural phosphoantigen extracts and their identification.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号