首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 766 毫秒
1.
S. O. Enibe   《Renewable Energy》2003,28(14):2269-2299
The transient thermal analysis of a natural convection solar air heater is presented. The heater consists of a single-glazed flat plate solar collector integrated with a paraffin type phase change material (PCM) energy storage subsystem and a rectangular enclosure which serves as the working chamber. The PCM is prepared in modules, with the modules equispaced across the absorber plate. The underside of the absorber plate, together with the vertical sides of the PCM module container, serve as air heating vanes. Air flow through the system is by natural convection. Energy balance equations are developed for each major component of the heater and linked with heat and mass balance equations for the heated air flowing through the system. The airflow rate is determined by balancing the buoyancy head resulting from thermally induced density differences and the friction head due to various flow resistances. The predicted performance of the system is compared with experimental data under daytime no-load conditions over the ambient temperature range of 19–41 °C and daily global irradiation of 4.9–19.9 MJ m–2. Predicted temperatures at specific locations on the absorber plate, heat exchanger plate, glazing, and heated air agree closely with experimental data to within 10, 6, 8, and 10 °C, respectively. Maximum predicted cumulative useful and overall efficiencies of the system are within the ranges 2.5–13 and 7.5–18%, respectively. Correlations of the predicted efficiencies are presented.  相似文献   

2.
An experimental energy storage system has been designed using an horizontal shell and tube heat exchanger incorporating a medium temperature phase change material (PCM) with a melting point of 117.7 °C. Two experimental configurations consisting of a control unit with one heat transfer tube and a multitube unit with four heat transfer tubes were studied. The thermal characteristics in the systems have been analysed using isothermal contour plots and temperature time curves. Temperature gradients along the three directions of the shell and tube systems; axial, radial and angular directions have been analysed and compared. The phase change in the multitube system was dominated by the effect of convective heat transfer compared to conductive heat transfer in the control system. The temperature gradient in the PCM during phase change was greatest in the radial direction for both the control and multitube systems. The temperature gradients recorded in the axial direction for the control and multitube systems during the change of phase were respectively 2.5 and 3.5% that of the radial direction, indicating essentially a two-dimensional heat transfer in the PCM. The onset of natural convection through the formation of multiple convective cells in the multitube system significantly altered the shape of the solid liquid interface fluid flow and indicates the requirement for an in-depth study of multitube arrangements.  相似文献   

3.
A thermal model is developed for heating and cooling of an agricultural greenhouse integrated with an aquifer coupled cavity flow heat exchanger system (ACCFHES). The ACCFHES works on the principal of utilizing deep aquifer water available at the ground surface through an irrigation tube well already installed in every agricultural field at constant year-round temperature of 24 °C. The analysis is based on the energy balance equations for different components of the greenhouse. Using the derived analytical expressions, a computer program is developed in C++ for computing the hourly greenhouse plant and room air temperature for various design and climatic parameters. Experimental validation of the developed model is carried out using the measured plant and room air temperature data of the greenhouse (in which capsicum is grown) for the winter and summer conditions of the year 2004–2005 at Chandigarh (31°N and 78°E), Punjab, India. It is observed that the predicted and measured values are in close agreement. Greenhouse room air and plant temperature is maintained 6–7 K and 5–6 K below ambient, respectively for an extreme summer day and 7–8 K and 5–6 K above ambient, respectively for an extreme winter night. Finally, parametric studies are conducted to observe the effect of various operating parameters such as mass of the plant, area of the plant, mass flow rate of the circulating air and area of the ACCFHES on the greenhouse room air and plant temperature.  相似文献   

4.
The thermal and dehumidification behaviour of a standard cross-flow type plate heat exchanger, intended for use as a dehumidifier/cooler, has been investigated both experimentally and numerically. Three sets of experiments have been carried out where air is blown into the primary and secondary sides of the exchanger, while water and liquid desiccant were being sprayed in a counter flow arrangement. The first set represents the indirect evaporative cooling of the primary stream by the secondary air stream. The second set is with liquid desiccant only and no indirect evaporative cooling. In the third set of experiments the primary air stream is indirectly evaporatively cooled by the secondary air stream and dehumidified by the liquid desiccant sprayed into the primary side of the exchanger. The above experiments indicate that the heat exchanger performs well when used with liquid desiccant. Furthermore, for an exchanger angle of 45°, there is an optimum value of air mass flow rate at which the effectiveness and dehumidification efficiency of the plate heat exchanger are maxima. To investigate the effect of the ambient air conditions on the PHE performance, further experiments were carried out using a heater element and a humidifier. The results show that under laboratory conditions the exchanger effectiveness and dehumidification efficiency increase with increasing primary air inlet temperature and humidity ratio. The experimental results were used to validate a computer model developed for the cross-flow type plate heat exchanger/dehumidifier. Comparison indicates that the numerical results are in good agreement with the experiments.  相似文献   

5.
In this article, we use the concept of artificial neural network and goal oriented design to propose a computer design tool that can help the designer to evaluate any aspect of earth-to-air heat exchanger and behavior of the final configuration. The present study focuses mostly on those aspects related to the passive heating or cooling performance of the building. Two models have been developed for this purpose, namely deterministic and intelligent. The deterministic model is developed by analyzing simultaneously coupled heat and mass transfer in ground whereas the intelligent model is a development of data driven artificial neural network model. Six variables influencing the thermal performance of the earth-to-air heat exchangers which were taken into account are length, humidity, ambient air temperature, ground surface temperature, ground temperature at burial depth and air mass flow rate. Furthermore, a sensitivity analysis was carried out in order to evaluate the impact of various factors involved in the energy balance equation at the burial depth. The model was validated against experimental data sets. Moreover, the developed algorithm is suitable for the calculation of the outlet air temperature and therefore of the heating and cooling potential of the earth-to-air heat exchanger system. The Intelligent model predicts earth-to-air heat exchanger outlet air temperature with an accuracy of ±2.6%, whereas, the deterministic model shows an accuracy of ±5.3%.  相似文献   

6.
Thermal performance and phase change stability of myristic acid as a latent heat energy storage material has been studied experimentally. In the experimental study, the thermal performance and heat transfer characteristics of the myristic acid were tested and compared with other studies given in the literature. In the present study is included some parameters such as transition times, temperature range, and propagation of the solid–liquid interface as well as heat flow rate effect on the phase change stability of myristic acid as a phase change material (PCM). The experimental results showed that the melting stability of the PCM is better in the radial direction than the axial direction. The variety of the melting and solidification parameters of the PCM with the change of inlet water temperature is also studied. The results show that the better stability of the myristic acid was accomplished at low inlet water temperature compared with the obtained results at high inlet water temperature. We also observed that while the heat exchanger tube is in the horizontal position, the PCM has more effective and steady phase change characteristics than in the vertical position. The heat storage capacity of the container (PCM tube) is not as good as we expected in this study and the average heat storage efficiency (or heat exchanger effectiveness) is 54%. It means that 46% of the heat acrually lost somewhere.  相似文献   

7.
A numerical and experimental investigation of phase change process dominated by heat conduction in a thermal storage unit is presented in this paper. The thermal energy storage involves a shell and tube arrangement where paraffin wax as phase change material (PCM) is filled in the shell. Water as heat transfer fluid (HTF) is passed inside the tube for both charging and discharging cycles. According to the conservation of energy, a simple numerical method called alternative iteration between thermal resistance and temperature has been developed for the analysis of heat transfer between the PCM and HTF during charging and discharging cycles. Experimental arrangement has been designed and built to examine the physical validity of the numerical results. Comparison between the numerical predictions and the experimental data shows a good agreement. A detailed parametric study is also carried out for various flow parameters and system dimensions such as different mass flow rates, inlet temperatures of HTF, tube thicknesses and radii. Numerical study reveals that the contribution of the inlet temperature of HTF has much influence than mass flow rate in terms of storage operating time and HTF outlet temperature. Tube radius is a more important parameter than thickness for better heat transfer between HTF and PCM.  相似文献   

8.
In this study a mathematical model of heat and mass transfer performance of a wavy fin-and-tube heat exchanger under wet surface condition is presented. The heat exchanger is a counterflow heat exchanger in which humid air and liquid are flowing in opposite direction. A water film that causes evaporative cooling of the humid air is circulated on the humid air side. The heat and mass transfer equations are first derived for fully wet heat exchanger and then by defining a wettability parameter, these equations are obtained for partially wet heat exchanger. In modeling, values of Lewis number and wettability parameter are not necessarily specified as unity. The temperature distributions of humid air, liquid and water film, and relative humidity distribution of humid air are obtained numerically. The theoretical results are found to be in good agreement with the available experimental measurements.  相似文献   

9.
This paper presents a set of differential and algebraic equations that model heat and mass transfer in condensers in which a mixture of water vapor and non-condensable gas is cooled. The model has been used to predict the condensation rate, the bulk temperatures of the coolant and the gas–vapor mixture, and the surface temperatures of the condenser wall. The predicted results for counter flow tube condensers are compared with three sets of published experimental data for system in which air is the non-condensable gas. It is found that the predicted condensation rates and coolant bulk temperatures agree very well with all the three sets of experimental data, the predicted wall temperatures agree reasonably well with the experimental results, and the agreement between the predictions and the experimental results on the bulk temperature of the air–vapor mixture is excellent for one set of the experimental data, reasonable for the second set of experimental data, but poor for the third set of experimental data. It is suggested that the poor agreement between the predicted and measured bulk temperatures of the mixture for the third set of experimental data arises from the experimental errors. The results from this study show that when modeling vapor condensation in the presence of a non-condensable gas, a simple model for the mixture channel alone may not be sufficient since neither the temperature nor the heat flux at the wall can be assumed to be constant. The results also show that the wall temperature in the coolant channel can be quite high, and careful modeling of the heat transfer in the coolant channel is needed in order to achieve good agreement between the model predictions and the experimental results.  相似文献   

10.
In this paper, an experimental study of the condensation of water vapor from a binary mixture of air and low‐grade steam has been depicted. The study is based upon diffusion heat transfer in the presence of high concentration of noncondensable gas. To simplify the study, experimental analysis is supported by empirical solutions. The experimental setup is custom designed for testing a new shell and tube type heat exchanger supplied by the manufacturer. Air–vapor mixture at 80 °C (max) and 20.2% relative humidity enters the heat exchanger at a mass flow rate of 480 kg/h and condenses 27 kg/h vapor using cooling water at an inlet temperature of 7 °C to 10 °C and mass flow rate of 3500 kg/h. By using the experimental data of constant inlet air mass fraction, mixture gas velocity, and different volumetric flow rate of the cold fluid, the local heat transfer coefficients are obtained. The main objective of this work is to establish an approximate value for surface area and overall heat transfer coefficient of a horizontal shell and tube condenser used in process space. Under designed working conditions, the condenser is found to work efficiently with 90% vapor condensation by mass.  相似文献   

11.
In this paper, a novel bayonet tube high temperature heat exchanger (HTHE) with inner and outer fins is presented. It can be used in the ultra high temperature environment, such as hydrogen production, very high temperature reactor and externally fired combined cycle. Numerical investigation of heat transfer performance on the inside of bayonet element has been conducted for structure design. The numerical results suggest that the inner fin and inner tube should not be welded together. It is recommended that the air enters from the inner tube and exits from the annular space in the high temperature zone. A high temperature experimental system has been established to test the heat transfer and pressure drop characteristics of the HTHE. The surface area density of the tested HTHE is 6 times higher than that of the bare bayonet tube heat exchanger. The experimental results indicate that the mass flow rate on both sides and inlet temperature on the fuel gas side have a significant effect on the heat transfer rate and effectiveness, while the pressure drop ratios are mainly affected by the mass flow rate rather than the inlet temperature. Comparison between the tested HTHE and the similar HTHE without fins indicates that the proposed HTHE has a significant potential to improve the comprehensive heat transfer performance.  相似文献   

12.
Roumsak Boonsri 《传热工程》2013,34(18):1495-1503
This paper is a continuation of the authors’ previous work. Theoretical and experimental studies of the heat transfer characteristics of a helical-coiled, crimped, spiral, finned-tube heat exchanger in dry surface conditions are presented. The test section is a helical-coiled, finned-tube heat exchanger. The coil unit is composed of four concentric helical-coiled tubes of different diameters. All tubes are constructed by bending straight copper tube into seven layers of helical coil. Aluminum crimped spiral fins, with an outer diameter of 28.25 mm and a thickness of 0.5 mm, are connected around the tube. Hot water is used as a working fluid for the tube side, while ambient air is used for the shell side. The test runs are done at air mass flow rates ranging between 0.04 and 0.13 kg/s. The water mass flow rates are between 0.2 and 0.4 kg/s. The water temperatures are between 40 and 50°C. A mathematical model is developed and the simulation results show reasonable agreement with the experimental data.  相似文献   

13.
Computational fluid dynamics (CFD) is applied to predicting the performance of closed-wet cooling towers (CWCTs) for chilled ceilings according to the cooling capacity and pressure loss. The prediction involves the two-phase flow of gas and water droplets. The predicted thermal performance is compared with experimental measurement for a large industrial CWCT and a small prototype cooling tower. CFD is then applied to the design of a new cooling tower for field testing. The accuracy of CFD modelling of the pressure loss for fluid flow over the heat exchanger is assessed for a range of flow velocities applied in CWCTs. The predicted pressure loss for single-phase flow of air over the heat exchanger is in good agreement with the empirical equation for tube bundles. CFD can be used to assess the effect of flow interference on the fluid distribution and pressure loss of single- and multi-phase flow over the heat exchanger.  相似文献   

14.
The thermal performance and phase change stability of stearic acid as a latent heat energy storage material has been studied experimentally. The thermal performance and heat transfer characteristics of the stearic acid were tested and compared with other studies given in the literature. In the present study, parameters such as transition times, temperature range and propagation of the solid–liquid interface as well as the effect of the heat flow rate on the phase change stability of stearic acid as a phase change material (PCM) were studied. The experimental results showed that the melting stability of the PCM is better in the radial direction than in the axial direction. The variation in the melting and solidification parameters of the PCM with the change of inlet water temperature is also studied. We observed that while the heat exchanger tube is in the horizontal position, the PCM has more effective and steady phase change characteristics than in the vertical position. The heat storage capacity of the container (PCM tube) is not as good as we expected in this study and the average heat storage efficiency (or heat exchanger effectiveness) is 50.3%. This indicates that 49.7% of the heat is actually lost somewhere.  相似文献   

15.
为探究相变温度对相变材料回填地埋管换热器传热性能的影响,建立管内流体换热、回填区域相变换热及土壤换热的三维耦合传热数值模型,利用焓-多孔介质模型对相变区域相变问题进行处理,研究夏季间歇运行工况下不同相变温度回填材料对埋管换热器传热性能的影响。结果表明:添加PCM,可有效提高换热量,短期内缓解埋管周围热积聚,利用相变温度18℃的PCM回填,单位井深换热量至少比普通材料回填提高49.54%;在间歇运行初期,换热量随相变温度的升高逐渐减小,低相变温度的PCM可明显改善埋管换热量,但随着时间的进行,较高相变温度PCM回填对换热器换热量的改善效果优于前期低相变温度。此外,在运行期间,不同相变温度的PCM表现出不同的熔化、凝固特性,当PCM的熔化、凝固过程交替进行时,可减缓土壤温度在运行期间内波动幅度。  相似文献   

16.
The present study aims to develop an approach to define the optimal dimensions of a phase change material (PCM) packed bed heat exchanger used as a cold thermal energy storage system in a conventional refrigerator. The heat exchanger is used to extend the daily refrigerator downtime and to ensure effective temperature control to contribute to the improved performance of the refrigerator. The mathematical model has been developed according to the technical characteristics and operating conditions of the refrigerator, the technical characteristics of the ventilator, and the thermo‐physical properties of the PCM. The model parameters that have been analyzed are the PCM melting time, air velocity range for tolerable efficient operating conditions, and the pressure drop through the PCM heat exchanger. As a case study, the approach was applied to a 600‐L conventional refrigerator equipped with a 63‐W ventilator. It has been found that over the tolerated velocity range of [2.5‐3.7 m/s], the optimal dimensions of the PCM heat exchanger are defined for an optimal velocity of 3.495 m/s. This is equivalent to an optimum sphere diameter of 0.071 m, a PCM heat exchanger length of 0.213 m, and a width of 0.148 m. The PCM heat exchanger ensures an extended compressor downtime of 12.6 hours for an ice‐PCM mass of 7.15 kg and occupies only 1.2% of the useful volume of the refrigerator.  相似文献   

17.
The use of a heat exchanger using phase change material (PCM) is an example of latent heat thermal energy storage (LHTES). In this study, the charging of PCM (RT50) is studied in a double pipe heat exchanger. The designing of the heat exchanger needs to be optimized for operating and boundary conditions to store latent heat efficiently. The size of the equipment and the amount of PCM are also important to calculate the latent heat storage capacity of the LHTES device. In this study, the amount of PCM taken is quite high to avoid sensible heat transfer and to maximize the heat content of PCM. The charging process of PCM is numerically simulated using an enthalpy-porosity model. The study includes the effect of inlet temperature and flow rate of high-temperature-fluid (HTF) and concludes that both play an important role in determining the charging time. The continuous increase in inlet temperature of HTF can decrease the charging time of PCM in the heat exchanger. However, the continuous increase in the HTF flow rate cannot show the same effect. The charging time can only be minimized with a specified flow rate regime for a specific inlet temperature of HTF. These factors consequently affect the efficiency of the heat exchanger.  相似文献   

18.
In this paper, numerical simulation and experimental investigation on unit heat exchange tube for solar heat receiver are reported. Based on enthalpy method, a physical and numerical model of the unit heat exchange tube was developed. An experimental system of solar simulator test rig was also set up with high temperature LiF–CaF2 eutectic mixture as the PCM and dry air as the working fluid. The hardware, test procedures, and test results from these experiments are also discussed. The simulating orbit data was numerically analyzed and compared with test data. Canister thermal performance can be predicted well by numerical canister analyses. The results show that the output temperature of the gas of the working fluid tubes meets the expected demand during the sunlight and eclipse period and the maximum temperature and average temperature of the PCM container were all under the safe range.  相似文献   

19.
Conjugate heat transfer to supercritical CO2 in a vertical tube-in-tube heat exchanger was numerically investigated. The results demonstrate that most models considered are able to reproduce the heat transfer processes qualitatively, and the Abe, Kondoh, and Nagano model shows optimal agreement with the experimental data. The influences of hot fluid mass flux and temperature of the shell side, supercritical fluid mass flux of the tube side, flow direction, and pipe diameter on conjugate heat transfer were investigated based on velocity and turbulence fields. It is concluded that hot fluid mass flux and temperature of the shell side significantly affect heat transfer of the tube side. Mixed convection is the main heat transfer mechanism for the supercritical CO2 conjugate heat transfer process when the inner diameter of the tube is greater than 1 mm. In addition, density variation is highly significant for heat transfer of supercritical CO2 while high viscosity hinders the distortion of the flow field and reduces deterioration in heat transfer.  相似文献   

20.
Cascaded latent heat storage for parabolic trough solar power plants   总被引:6,自引:0,他引:6  
The current revival of solar thermal electricity generating systems (SEGS) unveils the still existing need of economic thermal energy storages (TES) for the temperature range from 250 °C to 500 °C. The TES-benchmark for parabolic trough power plants is the direct two tank storage, as it was used at the SEGS I plant near Barstow (USA). With the introduction of expensive synthetic heat transfer oil, capable to increase the operating temperature from former 300 °C up to 400 °C, the direct storage technology became uneconomical. Cascaded latent heat storages (CLHS) are one possible TES alternative, which are marked by a minimum of necessary storage material. The use of a cascade of multiple phase change materials (PCM) shall ensure the optimal utilization of the storage material.This paper reports experimental and numerical results from the investigation of cascaded latent heat storages with alkali nitrate salts like NaNO3, KNO3 and others more. The experiments were conducted with vertical shell and tube type heat exchanger devices under realistic operation parameters. The experimental results were used for a numerical model to simulate different CLHS configurations. Dymola/Modelica was used to conduct the simulation. The outcome of this work shows on the one hand, that the design of CLHS for this temperature range is more complex than for the temperature range up to 100 °C. And on the other hand, the low heat conductivity of available PCM is an obstacle which must be overcome to make full use of this promising storage technology.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏