1.
Results from a series of fire tests carried out in a horizontal model tunnel (1:10) with longitudinal ventilation are presented. Pool fire with methanol as the fuel was used to simulate the fire source. Temperature and velocity distribution in the model tunnel were measured. The heat release rate, maximum gas temperature under the ceiling, back-layering length and critical velocity were investigated and compared with models proposed previously. Predicted maximum gas temperature under tunnel ceiling by Kurioka’s model agreed well with the experimental data with maximum discrepancy less than 20%. Dimensionless back-layering length was found decreased with the increase of the dimensionless ventilation velocity nearly linearly. Due to the difference between the experimental conditions and validating conditions of models proposed previously, diversities were found between the experimental results and predicted values base on Froude modeling. Maximum discrepancy on critical velocity might be about 40%. Models considering the effect of boundaries and heat loss of smoke more detailedly remain to be further developed.  相似文献   

2.
The “critical velocity” is the minimum air velocity required to suppress the smoke spreading against the longitudinal ventilation flow during tunnel fire situations. The current techniques for prediction of the values of the critical velocity for various tunnels were mainly based on semi-empirical equations obtained from the Froude number preservation combining with some experimental data. There are a few uncertainties in the current methods of prediction of the critical ventilation velocity. The first is the influence of the fire power on the critical ventilation velocity. The second is the effect of the tunnel geometry on the critical velocity. Both problems lead to the issues of the scaling techniques in tunnel fires. This study addressed these problems by carrying out a series of experimental tests in five model tunnels having the same height but different cross-sectional geometry. Detailed temperature and velocity distributions in the tunnels have been carried out. The experimental results showed that the critical velocity did vary with the tunnel cross-sectional geometry. It was also shown clearly that there are two regimes of variation of critical velocity against fire heat release rate. At low rates of heat release the critical velocity varies as the one-third power of the heat release rate, however at higher rates of heat release, the critical velocity becomes independent of fire heat release rate. Analysis of the distribution of temperature within the fire plumes showed that there were two fire plume distributions at the critical ventilation conditions. The change of the fire plume distribution coincided with the change of the regime in the curves of the critical velocity against fire heat release rate. The study used dimensionless velocity and dimensionless heat release rate with the tunnel hydraulic height (tunnel mean hydraulic diameter) as the characteristic length in the experimental data analysis. It was shown that the experimental data for the five tunnels can be correlated into simple formulae which can be used for scaling. The new scaling techniques are examined by applying the scaling techniques to the present experimental results and three large-scale experimental results available in the public literature. A good agreement has been obtained. This suggests that the scaling techniques can be used with confidence to predict the critical ventilation velocity for larger-scale tunnels in any cross-sectional geometry. Comprehensive CFD simulations have been carried out to examine the flow behaviour inside the tunnels. Validation against the experimental results showed that the CFD gave slightly lower but satisfactory prediction of the flow velocity. However the temperature prediction in the fire region was too high. The findings from the CFD simulations supported the ones from experimental tests.  相似文献   

3.
We examined the exhaust performance of a hybrid ventilation strategy for maintaining a safe evacuation environment for tunnel users in a tunnel fire. The hybrid ventilation strategy combines the longitudinal ventilation strategy with the point ventilation strategy which is a type of transverse ventilation strategy. The model tunnel developed by this study was scaled to 1/5 the size of a full-scale tunnel. The model-scale experiment was performed taking into consideration Froude's law of similarity. Measurement items were the distribution of temperature and concentration of smoke inside the tunnel, longitudinal wind velocity, mass flow of smoke in the point ventilation duct, and the heat release rate of the fire source. The following main conclusions were obtained. The smoke height was constant even when varying the extraction rate of smoke from the ceiling vent. The backlayering length and critical velocity of the smoke flow in the hybrid strategy could be predicted by the methodology developed by using the longitudinal strategy. The hybrid strategy maintained a safe evacuation environment on both sides of the tunnel fire.  相似文献   

4.
The fire service uses a number of tactics to reduce hazards for fire-fighters and civilians within a structure on fire. One offensive fire-fighting tactic that has potential for rapidly improving or degrading conditions within the structure is ventilating the structure. Positive pressure ventilation is a tactic in which a fan is used to push hot products of combustion out of a burning structure. While a recent body of work has been produced on the effects of positive pressure ventilation in a number of fire systems, there is still widespread uncertainty on how the tactic affects the fire environment. Computational tools will play an important role in exploring the impact of positive pressure ventilation in various fire scenarios. In many simulations of structure fires, the impact of leakage on the evolution of the fire is not addressed. We find in this study that ad hoc models of leakage have significant impact on the evolution of the fire. Several ad hoc leakage models are proposed and these are studied in terms of their impact of the fire. We show that one particular leakage geometry is able to best model leakage effects in a series of fire simulations that are compared to experiments. Simple, first-order analysis is used to understand how these leakage flows affect the predictions.  相似文献   

5.
水平隧道火灾通风纵向临界风速模型   总被引:1,自引:0,他引:1  
火灾时的烟气控制在隧道防火安全设计中占有很重要的位置,为此通过1/20小尺寸模型实验和全尺寸现场试验对水平隧道火灾通风纵向临界风速进行了研究。根据隧道全尺寸试验和小尺寸实验研究结果,并结合Jae等的小尺寸实验结果以及胡隆华的全尺寸试验和数值模拟结果,建立了水平隧道火灾通风纵向临界风速的预测模型。将模型得到的预测结果跟基于气体火源的实验结果进行对比,结果表明 Wu和Barker通过气体火源小尺寸实验所建立的模型预测值偏低。  相似文献   

6.
In order to detect a fire and provide adequate fire protection to a tunnel structure, the maximum gas temperature beneath the ceiling to which the structure is exposed needs to be estimated. Theoretical analysis of maximum gas temperature beneath a tunnel ceiling based on a plume theory is given. The heat release rate, longitudinal ventilation velocity and tunnel geometry are taken into account. Two series of model-scale experimental tests were also carried out. The results of both analysis and experiments show that the maximum excess gas temperature beneath the ceiling can be divided into two regions. When the dimensionless ventilation velocity is greater than 0.19, the maximum excess gas temperature beneath the tunnel ceiling increases linearly with the heat release rate and decreases linearly with the longitudinal ventilation velocity. When the dimensionless ventilation velocity is less than 0.19, the maximum excess gas temperature beneath the ceiling varies as the two-thirds power of the dimensionless heat release rate, independent of the longitudinal ventilation velocity. In both regions, the maximum excess gas temperature varies as the −5/3 power of the vertical distance between the fire source bottom and tunnel ceiling. The investigation presented here considers only the cases when the continuous flame region is lower than the ceiling height.  相似文献   

7.
Since the prediction of ‘critical velocity’ is important to control the smoke in tunnel fires, many researches have been carried out to predict critical velocity with various fire sizes, tunnel shape, tunnel slope, and so forth. But few researches have been conducted to estimate critical ventilation velocity for varied burning rate by longitudinal ventilation, although burning rate of fuel is influenced by ventilation conditions. Therefore, there is a need to investigate the difference of upstream smoke layer (e.g., backlayering) between naturally ventilated heat release rate and varied heat release rate by longitudinal ventilation.In this study, the 1/20 reduced-scale experiments using Froude scaling are conducted to examine the difference of backlayering between naturally ventilated heat release rate and varied heat release rate by longitudinal ventilation. And the experimental results obtained are compared with numerical ones. Three-dimensional simulations of smoke flow in the tunnel fire with the measured burning rates have been carried out using Fire Dynamics Simulator; Ver. 406 code, which is developed by National Institute of Standards and Technology. They show a good degree of agreement, even if some deviation in temperature downstream of the fire is evident. Since ventilation velocity had a greater enhancing effect on the burning rate of fuel due to oxygen supply effect, the critical ventilation velocity should be calculated on the basis of varied HRR by ventilation velocity.  相似文献   

8.
《Fire Safety Journal》2006,41(6):420-426
The objective is to carry out experiments on scale models and CFD calculations in order to study the influence of tunnel width W on critical velocity (for a given tunnel height H). By definition, the critical velocity is the minimum longitudinal velocity needed to prevent smoke back flow when a fire occurs in a tunnel. Two different experimental reduced scale models are used: the first one is a thermal model using a propane gas flame to simulate the fire and the second one is a densimetrical model in which the fire-induced- smoke is represented by a continuous release of an isothermal buoyant mixing. In both approaches, for aspect ratios W/H greater than unity, it is noticed that the critical velocity decreases when the width increases, as predicted by theory, but for low values of the aspect ratio (i.e. when W<H) and for high enough fire heat release rates, the critical velocity significantly increases with tunnel width. This can be associated to a change in the transverse flow pattern close to the buoyant source. Complementary CFD calculations are also presented in order to describe the influence of the lateral confinement on smoke plume spreading and then, on critical velocity.  相似文献   

9.
隧道内火灾的热释放速率对火灾蔓延和烟气生成起着关键作用。影响热释放速率的关键参数包括:燃烧物特性、隧道形状、通风条件以及车辆流量。综述了几年来热释放速率对这些参数的依赖性所做的研究成果。设计了贝页斯概率模型来模拟火灾热释放速率受隧道形状以及纵向通风的影响,设计了定性模型来模拟火灾在类似海底隧道内从一个物体蔓延到另一个物体的情况,通风条件同样是纵向通风,并给出了此次研究的初步成果。  相似文献   

10.
The position of the maximum ceiling gas temperature indicates how far the fire plum could be blown away by a ventilation flow. It could be applied to estimate the activation of a detection system or a sprinkler system, or to estimate the range of damage to the tunnel structure. An equation for predicting the position of the maximum ceiling gas temperature in a tunnel fire is proposed based on a theoretical analysis and validated using both laboratory test data and full scale test data. A flame angle has been defined based on the position of the maximum ceiling temperature in a tunnel fire. The flame angle is directly related to the dimensionless ventilation velocity, and it becomes insensitive to the heat release rate for a large tunnel fire. Further, it is found that a constant critical flame angle exists, defined as the flame angle under the critical condition when the backlayering just disappears. For a given tunnel and fire source, the flame angle under critical conditions is the same value, independent of heat release rate, and the maximum ceiling temperature under critical conditions always corresponds to the same position. Generally the horizontal distance between the position of the maximum ceiling temperature and the fire source centre is around 1.5 times the effective tunnel height under the critical condition.  相似文献   

11.
A detailed investigation is described of the interaction between fire development, smoke production and radiative exchange in a half-scale ASTM compartment in which the source is a heptane pool fire. Measurements of heat flux, fuel mass loss rate, ventilation flow rates, temperature and soot volume fraction are reported for the compartment for varying door widths. Data from the compartment are compared with open pool fire measurements using the same equipment. The confined geometry is shown to exert a strong influence on pool fire development and suggests that considerable caution is needed in employing open pool fire data as boundary conditions for CFD simulation. Numerical simulations based on the direct calculation of radiative exchange between the liquid fuel surface, the smoke-laden environment and bounding walls do reproduce the behaviour observed when combustion, soot production and radiation are modelled in detail and finely resolved spatially.  相似文献   

12.
Critical ventilation velocity for tunnel fires occurring near tunnel exits   总被引:1,自引:0,他引:1  
Ventilation is an effective method for controlling smoke during a tunnel fire. The “critical ventilation velocity” ucr is generally defined as the minimum velocity at which smoke is prevented from spreading against the longitudinal ventilation flow in tunnel fire situations. This study conducted small-scale experiments to investigate ucr for situations when tunnel fire occurs near tunnel exits. The model tunnel was 4 m long, 0.6 m wide and 0.6 m tall, and the fires were located at 0.5 m, 1.0 m and 1.5 m from the tunnel exit. 6.3×6.3 cm2 and 9.0×9.0 cm2 square asoline fuel pans were used as fire source. Results show that ucr decreases as the fire approaches the tunnel exit.  相似文献   

13.
超大断面水平隧道纵向通风临界风速CFD分析   总被引:4,自引:1,他引:3  
首先介绍了临界风速研究的基本思路及国内外主要研究成果.结合国内某长大公路隧道设计,建立一长300m、水力高度10.64m的水平隧道模型,通过CFD模拟确定超大断面隧道临界风速的影响因子及相应的准则关联式.模拟表明:与火灾热释放速率相比,环境温度的影响可以忽略不计;与Atkinson(模型试验)及Buxton(大尺度试验)相似,临界风速随热释放速率的变化分为两个区域,与低热释放速率时不同,一旦热释放速率超过40MW,临界风速的变化明显趋于缓慢.  相似文献   

14.
This paper investigates the buoyancy-driven smoke flow layering length (both upstream and downstream) beneath the ceiling with combination of point extraction and longitudinal ventilation in tunnel fires. A theoretical model is developed based on previous back-laying model with only longitudinal ventilation, with modified actual heat release rate, as well as modified upstream and downstream opposing longitudinal air flow velocities by the induced flow velocity due to point extraction. Experiments are carried out in a reduced scale model tunnel with dimensionless of 72 m×1.5 m×1.3 m. A LPG porous gas burner is used as fire source. The smoke flow layering length both upstream and downstream are identified based on temperature profiles measured along the ceiling, for different experiment conditions. CFD simulations with FDS are also performed for the same scenarios. Results show that with combination of point extraction and longitudinal ventilation, the smoke flow layering length is not symmetric where it is longer downstream than that upstream. The upstream smoke layering length decreases, while the downstream layering length increases with increase in longitudinal ventilation velocity; and they both decrease with increase in point extraction velocity. The predictions by the proposed theoretical model agree well with the measurements and simulation results.  相似文献   

15.
This paper adopts a series of 1:20 scale tunnel experiments based on a series of large-scale tunnel experiments to study the influence of forced ventilation on fires. The small-scale tunnel has dimensions of 0.365 m (W)×0.26 m (H)×11.9 m (L). Cribs using a wood-based material provide the fuel source and forced ventilation velocities from 0.23 to 1.90 m/s are used. From the study of the measured heat release rate (HRR) and mass loss rate data it is found that the forced air velocity affects the fire spread rate and burning efficiency and further affects peak HRR values at different air velocities. A simple model to describe these influences is proposed. This model is used to reproduce the enhancement of peak HRR for cribs with different porosity factors noted by Ingason [1] and to assess the effects of using different length of cribs on peak HRR. The results from these analyses suggest that different porosity fuels result different involvement of burning surface area and result different changes in peak HRR. However, no significant difference to the enhancement on fire size is found when the burning surface area is similar. It is also found that the trend in the enhancement on fire size by using sufficiently long crib and available ventilation conditions matches the predictions of Carvel and Beard [2] for two-lane tunnel heavy goods vehicle fires.  相似文献   

16.
《Fire Safety Journal》2001,36(1):37-54
In this study, three combustion models, the volumetric heat source (VHS) model, the eddy break-up model and the presumed probability density function (prePDF) model, are examined in enclosure fire simulation. The combustion models are compared and evaluated for their performance in predicting three typical enclosure fires, a room fire, a shopping mall fire and a tunnel fire. High Reynolds number turbulence kε model with buoyancy modification and the discrete transfer radiation model (DTRM) are used in the simulation. Corresponding experimental data from the literature are adopted for validation. The results show satisfactory prediction in flow patterns and features in the complex enclosure fires. However, it is shown that these combustion models are not able to show consistent performance over the different locations and enclosure fires. The needs for adequate turbulent combustion models in enclosure fires are discussed.  相似文献   

17.
Due to the small width and the large train blockage ratio in subway tunnel, the smoke back-layering will be different from that in the wider road tunnel with small vehicle blockage ratio. In the train blockage region of tunnel, the velocity of longitudinal ventilated air-flow interacting with the back-flowed smoke gas is different from that in the upstream tunnel without train blockage. Then the back-flowed smoke gas might be prevented in the train blockage region with higher ventilation velocity, otherwise it would be stopped in the upstream tunnel without train blockage but with lower ventilation velocity. They were taken into consideration separately and an equivalent fire source was introduced by dividing the dimensionless heat release rate of fire source into two parts in the cases where the smoke back-layering length is longer than metro train length. A series of full-scale numerical simulations are carried out with FDS to investigate the smoke back-layering length in subway tunnel with different train lengths and longitudinal ventilation velocities. The simulation results indicate that the influence of metro train length on the smoke back-layering is great and cannot be ignored any more. A global correlation model is proposed based on the dimensionless analysis and simulation results.  相似文献   

18.
为满足隧道火灾安全体系研究方面的需要,本文以中国科学技术大学火灾科学国家重点实验室的隧道试验台为对象,进行了比例模型隧道火灾试验,并利用Fire Dynamics Simulator(FDS)软件对该实验在不同纵向风速控制条件下的火灾烟气层沉降速度进行了计算机模拟,通过试验与模拟结果的对比,给出了不同纵向通风速度下,隧道火灾时烟气层沉降速度的变化规律,并提出了烟气分层化临界风速这一概念,为隧道火灾的控制、救援和人员疏散提供了一定的参考价值.  相似文献   

19.
北京地铁4号线隧道火灾烟气控制的CFD模拟   总被引:1,自引:0,他引:1  
本文根据北京地铁4号线某段隧道的实际尺寸建立了几何模型,针对该模型利用CFD方法模拟了纵向通风对控制火灾烟气扩散的作用,研究了不同热源形状条件下临界通风速度与热释放率的关系,并将其与已有研究成果进行了对比.结果显示在热源形状不变时,临界通风速度与热释放率(HRR)和隧道宽度之比的1/3次方成正比,热羽流在临界通风速度下倾斜角为常数;当热源长度随热释放率成比例变化时,临界通风速度在高热释放率条件下呈现出稳定不变的趋势.研究表明在采用数值模拟方法进行隧道火灾通风设计时,热源条件的设置对模拟结果有显著影响.  相似文献   

20.
《Fire Safety Journal》2005,40(3):213-244
In ventilated tunnel fires, smoke and hot combustion products may form a layer near the ceiling and flow in the direction opposite to the ventilation stream. The existence of this reverse stratified flow has an important bearing on fire fighting and evacuation of underground mine roadways, tunnels and building corridors. In the present study, conducted by the National Institute for Occupational Safety and Health, a CFD program (fire dynamics simulator) based on large eddy simulations (LES) is used to model floor-level fires in a ventilated tunnel. Specifically, the critical ventilation velocity that is just sufficient to prevent the formation of a reverse stratified layer is simulated for two tunnels of different size. The computer code is verified by checking the computed velocity profile against experimental measurements. The CFD results show the leveling-off of the critical ventilation velocity as the heat release rate surpasses a certain value. At this critical ventilation, the ceiling temperature above the fire reaches a maximum for both tunnels. The velocity leveling-off can be explained from this observation. An extended correlation of Newman (Combust. Flame 57 (1984) 33) is applied to the temperature profiles obtained by CFD. At the critical ventilation, temperature stratification exists downstream from the fire. The computed critical ventilation velocity shows fair agreement with available experimental data taken from both horizontal and inclined fire tunnels. The CFD simulations indicate that the Froude modeling is an approximation for tunnel fires. The Froude-scaling law does not apply to two geometrically similar fire tunnels. The CFD results are compared with two simple theories of critical ventilation by Kennedy et al. (ASHRAE Trans. Res. 102(2) (1996) 40) and Kunsch (Fire safety J. 37 (2002) 67).  相似文献   