首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Applied Energy》1999,63(3):169-190
In recent years, it has become standard practice to consider Combined Heat-and-Power (CHP) systems for commercial buildings. CHP schemes are used, because they are an efficient means of power generation. Unlike conventional power stations, they produce electricity locally and thus minimise the distribution losses, however, they also utilise the waste heat from the generation process. In applications where there is a combined heating and electricity requirement, a very efficient means of energy production is achieved compared to the conventional methods of providing heating and electricity. With new initiatives from the UK government on reduced energy-use, energy-efficient systems such as CHP have been considered for new applications. This paper summarises the results of an investigation into the viability of CHP systems in supermarkets. The viability of conventional CHP has been theoretically investigated using a mathematical model of a typical supermarket. This has demonstrated that a conventional CHP system may be practically applied. It has also been shown that compared to the traditional supermarket design, the proposed CHP system will use slightly less primary energy and the running costs will be significantly reduced. An attractive payback period of approximately 4 years has been calculated. Despite these advantages a considerable quantity of heat is rejected to atmosphere with this system and this is because the configuration utilises the heat mainly for space heating which is only required for part of the year. To increase the utilisation time, a novel CHP/absorption system has been investigated. This configuration provides a continuous demand for the waste heat, which is used to drive an absorption chiller that refrigerates propylene glycol to −10°C for cooling the chilled-food cabinets. The results show this concept to be theoretically practical. The system has also been shown to be extremely efficient, with primary energy savings of approximately 20%, when compared to traditional supermarket designs and this would result in significant revenue cost savings as well as environmental benefits. Based upon these savings a payback period for this system of approximately 5 years has been demonstrated.  相似文献   

2.
In the present paper, design and economics of the novel type of thermal control system for datacenter using heat pipe based cold energy storage has been proposed and discussed. Two types of cold energy storage system namely: ice storage system and cold water storage system are explained and sized for datacenter with heat output capacity of 8800 kW. Basically, the cold energy storage will help to reduce the chiller running time that will save electricity related cost and decrease greenhouse gas emissions resulting from the electricity generation from non-renewable sources. The proposed cold energy storage system can be retrofit or connected in the existing datacenter facilities without major design changes. Out of the two proposed systems, ice based cold energy storage system is mainly recommended for datacenters which are located in very cold locations and therefore can offer long term seasonal storage of cold energy within reasonable cost. One of the potential application domains for ice based cold energy storage system using heat pipes is the emergency backup system for datacenter. Water based cold energy storage system provides more compact size with short term storage (hours to days) and is potential for datacenters located in areas with yearly average temperature below the permissible cooling water temperature (∼25 °C). The aforesaid cold energy storage systems were sized on the basis of metrological conditions in Poughkeepsie, New York. As an outcome of the thermal and cost analysis, water based cold energy storage system with cooling capability to handle 60% of datacenter yearly heat load will provide an optimum system size with minimum payback period of 3.5 years. Water based cold energy storage system using heat pipes can be essentially used as precooler for chiller. Preliminary results obtained from the experimental system to test the capability of heat pipe based cold energy storage system have provided satisfactory outcomes and validated the proposed system concept.  相似文献   

3.
Combined heating and power (CHP) systems may be considered for installation if they produce savings over conventional systems with separate heating and power. For a CHP system with a natural gas engine as the prime mover, the difference between the price of natural gas and the price of purchased electricity, called spark spread, is an indicator as to whether a CHP system might be considered or not. The objective of this paper is to develop a detailed model, based on the spark spread, that compares the electrical energy and heat energy produced by a CHP system against the same amounts of energy produced by a traditional, or separate heating and power (SHP) system that purchases electricity from the grid. An expression for the spark spread based on the cost of the fuel and some of the CHP system efficiencies is presented in this paper as well as an expression for the payback period for a given capital cost and spark spread. The developed expressions allow determining the required spark spread for a CHP system to produce a net operational savings over the SHP in terms of the performance of system components. Results indicate that the spark spread which might indicate favorable payback varies based on the efficiencies of the CHP system components and the desired payback period. In addition, a new expression for calculating the payback period for a CHP system based on the CHP system capital cost per unit of power output and fuel cost is proposed.  相似文献   

4.
Combined cooling and heating using a gas engine in a supermarket   总被引:1,自引:0,他引:1  
This paper reports the results of an investigation into the practical and economic viability of an integrated combined heating and cooling system in a supermarket. This system consists of a direct-drive screw compressor, which is powered by a throttle controlled gas engine. The waste heat from the engine is used to provide hot water for space heating and for general usage within the catering and toilet facilities in the supermarket. In this paper, the working principle of the novel system is first described. This details how the gas engine system may be integrated into the typical supermarket. The paper then describes a model, which is used to simulate the energy consumption of the supermarket. This is used to calculate the energy consumed by the conventional system and that used by a number of alternative combined heating and cooling system configurations, which are also described. The additional capital cost of each configuration is estimated and this is used to calculate the payback period. The results show that a payback period of 4.2 years may be achieved with a system that uses approximately 500,000 kWh per annum less primary energy than a conventional system. Finally, comparison between this system and a traditional Combined Heat and Power (CHP) installation is given.  相似文献   

5.
Distributed energy systems are considered as a promising technology for sustainable development and have become a popular research topic in the areas of building energy systems. This work presents a case study of optimizing an integrated distributed energy system consisting of combined heat and power(CHP), photovoltaics(PV), and electric and/or thermal energy storage for a hospital and large hotel buildings located in Texas and California. First, simulation models for all subsystems, which are developed individually, are integrated together according to a control strategy designed to satisfy both the electric and thermal energy requirements of a building. Subsequently, a multi-objective particle swarm optimization(MOPSO) is employed to obtain an optimal design of each subsystem. The objectives of the optimization are to minimize the simple payback period(PBP) and maximize the reduction of carbon dioxide emissions(RCDE). Finally, the energy performance for the selected building types and locations are analyzed after the optimization. Results indicate that the proposed optimization method could be applied to determine an optimal design of distributed energy systems, which reaches a trade-off between the economic and environmental performance for different buildings. With the presented distributed energy system, a peak shaving in electricity of about 300 kW and a reduction in boiler fuel consumption of 610 kW could be attained for the hospital building located in California for a winter day. For the summer and transition seasons, electricity peak shaving of 800 kW and 600 kW could be achieved, respectively.  相似文献   

6.
荆玲  韦新东  高青  赵晶波  常欣 《节能技术》2010,28(4):342-346
本论文探讨了长春市新建民用建筑采用热电联产时的节能、环保和经济效果。由长春和东京气候条件的相似性,以东京能源消耗强度为基础,利用修正系数推算长春能源消耗强度。根据不同建筑用途的建筑面积和能源消耗强度,计算了长春市新建民用建筑的能源需要量。本研究设立了空调系统、锅炉系统、热主电从和电主热从系统。同时,设定了设备效率和价格、能源价格和二氧化碳排放强度等参数。计算四种能源供给系统的一次能源消费量、二氧化碳排放量、初期投资、运行费用和单纯回收年数。计算结果为:与空调系统相比,锅炉系统、热主电从和电主热从的热电联产系统的节能率分别为-2.1%、21.2%和6.0%;二氧化碳排放量的消减率分别为-0.7%、24.1%和9.4%;单纯回收年数分别为8.0,5.2和3.5年。  相似文献   

7.
M.B. Blarke  H. Lund 《Renewable Energy》2008,33(7):1499-1507
Across the world, energy planners and transmission system operators are faced with decisions on how to deal with challenges associated with high penetration levels of intermittent energy resources and combined heat and power (CHP). At the same time, distributed plant operators are eager to reduce uncertainties related to fuel and electricity price fluctuations. These interests meet-up for options in distributed supply that introduces the principle of storage and relocation, typically by integrating heat pumps (HP) or electric boilers (EBs) into the operational strategies of existing CHP plants. This paper introduces the principle of storage and relocation by energy system design, and proposes for the storage and relocation potential of a technology option to be found by comparing options by their storage and relocation coefficient Rc, defined as the statistical correlation between net electricity exchange between plant and grid, and the electricity demand minus intermittent renewable electricity production. Detailed operational analyses made for various CHP options within the West Danish energy system, point to the concepts of CHP-HP and CHP-HP cold storage for effectively increasing energy system flexibility. For CHP-HP cold storage, Rc increases from 0.518 to 0.547, while the plant's fuel efficiency increases from 92.0% to 97.2%. These findings are discussed within frameworks of renewable energy systems, suggesting principles for 1st, 2nd, and 3rd generation system designs.  相似文献   

8.
针对目前刺参养殖的水温调控系统能耗大及适用性差等问题,提出基于冰源热泵的高效清洁供热及结合跨季节蓄冷实现全年冷热管理的技术思路,采用冰源热泵系统和跨季节蓄冷型冰源热泵系统对养殖水体温度进行调控,建立模型定量对比分析系统的运行能效及技术经济性.结果表明:(1)冰源热泵系统供热和供冷时的性能系数分别为3.33和3.39,全...  相似文献   

9.
Today a lot of Arctic remote communities rely on electrical energy produced by diesel generators. This type of energy is very expensive as apart from high fuel prices, the transportation costs to the remote location, also need to be added. The goal of this study is to evaluate an application of the wind turbines combined with the hydrogen energy storage system for supporting existing diesel infrastructure on the example of Grimsey island (Iceland). HOMER Energy Microgrid Power Design software is used to perform energy balance simulations and to optimise the size of the system components. The statistical data about electrical energy consumption and wind resources on Grimsey are used as a case study. The results indicate that proposed system infrastructure might be a feasible solution and the payback period of below 4 years was estimated for the optimal system configuration.  相似文献   

10.
This paper presents a techno-economic analysis of corn stover fired process heating (PH) and the combined heat and power (CHP) generation systems for a typical corn ethanol plant (ethanol production capacity of 170 dam3). Discounted cash flow method was used to estimate both the capital and operating costs of each system and compared with the existing natural gas fired heating system. Environmental impact assessment of using corn stover, coal and natural gas in the heat and/or power generation systems was also evaluated. Coal fired process heating (PH) system had the lowest annual operating cost due to the low fuel cost, but had the highest environmental and human toxicity impacts. The proposed combined heat and power (CHP) generation system required about 137 Gg of corn stover to generate 9.5 MW of electricity and 52.3 MW of process heat with an overall CHP efficiency of 83.3%. Stover fired CHP system would generate an annual savings of 3.6 M$ with an payback period of 6 y. Economics of the coal fired CHP system was very attractive compared to the stover fired CHP system due to lower fuel cost. But the greenhouse gas emissions per Mg of fuel for the coal fired CHP system was 32 times higher than that of stover fired CHP system. Corn stover fired heat and power generation system for a corn ethanol plant can improve the net energy balance and add environmental benefits to the corn to ethanol biorefinery.  相似文献   

11.
储能项目的经济性是制约储能项目商业化的重要因素之一。其中商业模式对项目经济性起着决定性作用。通过分析国内储能系统相关政策与发展现状,根据给定的储能项目系统结构与盈利方式,建立项目经济模型,通过内部收益率、投资回收期和发展成本等经济性指标评价了项目的经济性。进一步,以储能项目商业化融资难的问题为突破点,引入直接融资租赁模式,评估了在融资租赁公司低成本采购优势下项目的经济性。通过分析可知,融资租赁模式的引入可以缓解企业前几年的资金压力,提高项目的经济效益。  相似文献   

12.
Building integrated photovoltaic (BiPV) systems generate electricity, but also heat, which is typically wasted and also reduces the efficiency of generation. A heat recovery unit can be combined with a BiPV system to take advantage of this waste heat, thus providing cogeneration. Two different photovoltaic (PV) cell types were combined with a heat recovery unit and analysed in terms of their life-cycle energy consumption to determine the energy payback period. A net energy analysis of these PV systems has previously been performed, but recent improvements in the data used for this study allow for a more comprehensive assessment of the combined energy used throughout the entire life-cycle of these systems to be performed. Energy payback periods between 4 and 16.5 years were found, depending on the BiPV system. The energy embodied in PV systems is significant, emphasised here due to the innovative use of national average input–output (IO) data to fill gaps in traditional life-cycle inventories, i.e. hybrid analysis. These findings provide an insight into the net energy savings that are possible with a well-designed and managed BiPV system.  相似文献   

13.
A detailed system study on an integrated gasifier-SOFC test system which is being constructed for combined heat and power (CHP) application is presented. The performance of the system is evaluated using thermodynamic calculations. The system includes a fixed bed gasifier and a 5 kW SOFC CHP system. Two kinds of gas cleaning systems, a combined high and low temperature gas cleaning system and a high temperature gas cleaning system, are considered to connect the gasifier and the SOFC system. A complete model of the gasifier-SOFC system with these two gas cleaning systems is built and evaluated in terms of energy and exergy efficiencies. A sensitivity study is carried out to check system responses to different working parameters. The results of this work show that the electrical efficiencies of the gasifier-SOFC CHP systems with different gas cleaning systems are almost the same whereas the gasifier-SOFC CHP systems with the high temperature gas cleaning system offers higher heat efficiency for both energy and exergy.  相似文献   

14.
High efficiency thermoelectric generators (TEG) can recover waste heat from both industrial and private sectors. Thus, the development and deployment of TEG may represent one of the main drives for technological change and fuel substitution. This paper will present an analysis of system efficiency related to the integration of TEG into thermal energy systems, especially Combined Heat and Power production (CHP). Representative implementations of installing TEG in CHP plants to utilize waste heat, wherein electricity can be generated in situ as a by-product, will be described to show advantageous configurations for combustion systems. The feasible deployment of TEG in various CHP plants will be examined in terms of heat source temperature range, influences on CHP power specification and thermal environment, as well as potential benefits. The overall conversion efficiency improvements and economic benefits, together with the environmental impact of this deployment, will then be estimated. By using the Danish thermal energy system as a paradigm, this paper will consider the TEG application to district heating systems and power plants through the EnergyPLAN model, which has been created to design suitable energy strategies for the integration of electricity production into the overall energy system.  相似文献   

15.
李力群 《节能》2012,31(11)
介绍太阳能热水系统结合低温热水地板采暖系统的工作原理,以上海地区为例,在高层住宅中应用壁挂式太阳能集热器,可以实现太阳能与建筑一体化。对该太阳能系统进行节能效益分析,结果表明,系统的动态回收期为3.98年。  相似文献   

16.
Decision making under uncertainty is a difficult task in most areas. Investment decisions for combined heat and power production (CHP) are certainly one of the areas where it is difficult to find an optimal solution since the payback period is several years and parameters change due to different perturbing factors of economic and mostly political nature.  相似文献   

17.
The future energy system in community level should be more ‘smart’ to secure reliability, enhance market service, minimize environmental impact, reduce costs and improve the use of renewable energy source (RES). Therefore, this paper proposes an energy integration system – smart hybrid renewable energy for communities (SHREC). It considers both thermal (heating and cooling) and electricity market in a large community level and highlight the interactions between them through utilizing RES, combined heat and power (CHP) and energy storages. A planning model based on CHP modelling is developed for the SHREC system. A linear programming (LP) algorithm is developed to optimize the SHREC system in a weekly period and the results are compared with an existing energy optimization software. We also demonstrate the model in a sample SHREC system during three typical weeks with cold, warm and mid-season weather in the year 2011. The results indicate that the developed modelling and optimization method is more efficient and flexible for the smart hybrid renewable energy systems.  相似文献   

18.
Energy recovery ventilators (ERVs) are exhaust air energy recovery devices for outdoor ventilation air preconditioning in building HVAC systems. The energy and economic performance of an ERV depends on its effectiveness, cost, maintenance as well as other parameters such as climate, building design and HVAC system parameters. In this study, a sensitivity analysis is used to evaluate the impact of uncertainty of building and HVAC system parameters on the energy savings potential and economics of ERVs. Firstly, the impact of building parameters on HVAC system peak loads, capital cost, annual energy use and operating cost are investigated for an office building located in Chicago using TRNSYS simulations. The results show that the ventilation rate has the most significant impact on total HVAC system energy performance. Secondly, energy and economic analysis on the ERV’s payback period is conducted with a specified variation of each input parameter. The results illustrate that an ERV with 75% sensible and 60% latent effectiveness can reduce the peak heating load by 30%, the peak cooling load by 18%, the annual heating energy usage by 40% and the annual cooling energy usage by 8%, with a payback period of 2 years. The uncertainty of ERV’s payback period to its initial cost, recovery effectiveness, energy rate, HVAC equipment initial cost and efficiency as well as ventilation rate are also presented. A ±25% uncertainty in the 7 building and HVAC system input parameters studied results in a maximum 17% and 225% uncertainty in the payback period of the ERV respectively.  相似文献   

19.
The potential for both heat and power extraction from a PEM fuel cell is investigated experimentally and using computer simulation to improve the economics of a solar-hydrogen system supplying energy to a remote household. The overall average energy efficiency of the fuel cell was measured to be about 70% by utilizing the heat generated for domestic water heating, compared to only 35-50% for electricity generation alone. The corresponding round-trip energy efficiency of the hydrogen storage sub-system (electrolyzer, storage tank, and fuel cell) was raised from about 34% in a power-only application to about 50% in combined heat and power (CHP) mode. The economic benefit of using the fuel cell heat for boosting an LPG hot water system over a 30-year assessment period is estimated to be equivalent to about 15% of the total capital cost of the solar-hydrogen system. The stoichiometry of the input air, and the fuel cell operating temperature, were found to influence significantly the overall performance of the solar-hydrogen CHP system.  相似文献   

20.
There is a growing, government-led trend of applying renewable energy in Hong Kong. One area of interest lies in the wider use of solar-energy systems. The worldwide fast development of building-integrated solar technology has prompted the design alternative of fixing the solar panels on the external façades of buildings. In Hong Kong, high-rise buildings are found everywhere in the urban districts. How to make full use of the vertical facades of these buildings to capture the most solar radiation can be an important area in the technology promotion. In this numerical study, the potential application of a centralized solar water-heating system in high-rise residence was evaluated. Arrays of solar thermal collectors, that occupied the top two-third of the south and west façades of a hypothetical high-rise residence, were proposed for supporting the domestic hot-water system. Based on typical meteorological data, it was found that the annual efficiency of the vertical solar collectors could reach 38.4% on average, giving a solar fraction of 53.4% and a payback period of 9.2 years. Since the solar collectors were able to reduce the heat transmission through the building envelope, the payback was in fact even shorter if the energy saving in air-conditioner operation was considered.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号