首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Applied Thermal Engineering》2007,27(5-6):1054-1061
The integration of a water purification system allows a heat transformer to increase the actual coefficient of performance, by the reduction of the amount of heat supplied by unit of heat. A new defined COP called COPWP is proposed for the present system, which considers the fraction of heat recycled. Simulation with proven software compares the performance of the modeling of an absorption heat transformer for water purification (AHTWP) operating with water/lithium bromide, as working fluid–absorbent pair. Plots of enthalpy-based coefficients of performance (COPET) and water purification coefficient of performance (COPWP) are shown against absorber temperature for several thermodynamic operating conditions. The results showed that the proposed (AHTWP) system is capable of increasing the original value of COPET up to 1.6 times its original value by recycling energy from a water purification system. The proposed COPWP allows increments for COP values from any experimental data for water purification or for any other distillation system integrated to a heat transformer, regardless of actual COPA value or working fluid–absorbent pair.  相似文献   

2.
An experimental study has been carried out on a continuously operated pilot fractional distillation column equipped with an external heat pump. The distillation column was a 15 cm diameter glass unit containing eleven single bubble cap plates. A methanol-water mixture was fed to the column and the heat pump working fluid was R114. The actual coefficient of performance (COP)A of the heat pump increased with an increase in the mass flow rate of the working fluid. A maximum (COP)A value of 4–3 was obtained with a gross temperature lift of 41–3°C. The performance of two reciprocating compressors was compared. The experiments have shown that continuous heat pump assisted distillation using an external working fluid can greatly reduce the energy used in a distillation process. No control problems were encountered in the experiments.  相似文献   

3.
An experimental study has been carried out on a continuously operated pilot fractional distillation column equipped with an external heat pump. The distillation column was a 153 mm diameter stainless steel unit containing fourty-four sieve plates. An ethanol-water mixture was fed to the column and the heat pump working fluid was R114. The actual coefficient of performance (COP)A of the heat pump increased with an increase in the mass flow rate of the working fluid. A maximum value of 4.5 was obtained with a gross temperature lift of 45°C. The performance of two reciprocating compressors was compared. A heat pump effectiveness factor of 0.8 was achieved. A maximum relative contribution of the heat pump of 65 per cent was obtained with minimum temporary insulation. With good insulation it is estimated that the relative contribution of the heat pump should exceed 80 per cent at the design feed rate. No control problems were encountered in the experiments.  相似文献   

4.
《Applied Thermal Engineering》2007,27(5-6):1043-1053
The integration of a water purification system in a heat transformer allows a fraction of heat obtained by the heat transformer to be recycled, increasing the heat source temperature. Consequently, the evaporator and generator temperatures are also increased. For any operating conditions, keeping the condenser and absorber temperatures and also the heat load to the evaporator and generator, a higher value of COP is obtained when only the evaporator and generator temperatures are increased. Simulation with proven software compares the performance of the modeling of an absorption heat transformer for water purification (AHTWP) operating with water/lithium bromide, as the working fluid–absorbent pair. Plots of enthalpy-based coefficients of performance (COPET) and the increase in the coefficient of performance (COP) are shown against absorber temperature for several thermodynamic operating conditions. The results showed that proposed (AHTWP) system is capable of increasing the original value of COPET more than 120%, by recycling part of the energy from a water purification system. The proposed system allows to increase COP values from any experimental data for water purification or any other distillation system integrated to a heat transformer, regardless of the actual COP value and any working fluid–absorbent pair.  相似文献   

5.
The use of thermal processes for water purification is a good alternative to reduce primary energy consumption. The efficiency in heat exchange process by falling film plays a very important role in the performance of a heat pump. The objective of this paper is to evaluate the efficiency of heat transfer on a tube bank, of a heat transformer designed for water purification with LiBr–H2O as absorbent mixture, by digital image processing. To analyze the wetting area and falling film behavior of the mixture on a bank of sixteen horizontal tubes, of 1.22 cm outer diameter and 30 cm in length, experimental tests were performed. The results show the distribution of absorbent mixture, along the tubes of the bank, with 0 and 5° inclination respect to the horizontal, and different mass flow rates per unit length (0.006–0.034 kg/m s). The film thickness of LiBr–H2O was determined by the digital image processing, obtaining an average value of 0.033 cm. The most regular fall of mixture, through the tubes of the bank, was obtained with the flow of 0.025 kg/m s. This mass flow was the one which gave the best results of efficiency of heat transfer, with values between 80 and 98%.  相似文献   

6.
《Applied Thermal Engineering》2007,27(5-6):988-993
A critical cycle heat pump with HFC125 was studied experimentally. The experimental result indicates that the heat pump with HFC125 can use the general components of the conventional heat pump well. Hot water with wide-range temperature can be conveniently got by the critical heat pump system through water flow control. The COPh of the critical cycle drops a little when the temperature of outlet water rises from 60 °C to 75 °C. And adding heat recovering exchanger cannot improve the performance of the cycle, but can reduce the working pressure of the cycle. Comparing with the CO2 trans-critical heat pump, HFC125 critical heat pump has a better performance of refrigeration, lower working pressure, which is especially suitable for dual-function of supplying hot water and refrigeration in the civil and industrial buildings.  相似文献   

7.
A novel heat pump and power generation integration system (HPPGIS) using solar energy as a low temperature heat source was presented in this study. This system could be operated in both an organic Rankine cycle power generation (ORC‐PG) mode and a reverse Carnot cycle heat pump (RCC‐HP) mode. Compared with a single heat pump and power generation system, this system improved the utilization efficiency of solar energy, thus showing potential for the generation of economic benefits. Contrastive analyses of different working fluids using ORC‐PG and RCC‐HP systems were conducted first, leading to the selection of R142b and R245fa as optimal fluids. Then, an experimental investigation of the system was carried out under different conditions. A heat pump and ORC system model was proposed and validated by comparing experimental and simulated values. The experimental results indicated that the HPPGIS had good feasibility and stability in both modes. In the ORC‐PG mode, HPPGIS had a power output of 1.29 kW and a thermal efficiency of 4.71% when the water inlet temperature of the evaporator was 90.03°C. In the RCC‐HP mode, HPPGIS had a COP of 3.16 and a heat capacity of 33.24 kW when the water outlet temperature of the condenser was 106.23°C.  相似文献   

8.
The investigation presented in this article is aimed at demonstrating the technical and design feasibility of using ground-source heat pump systems in the mild climate applications for greenhouse heating, where heating requirements are dominant. An experimental comparison between a horizontal ground-source heat pump system and a vertical ground-source heat pump system was shown by focusing on the heating performance. For this purpose, an experimental set-up was constructed. The heating system mainly consists of two different ground heat exchangers, a heat pump, measuring units and a heating space of a model-sized glass greenhouse with 30 m2 located in the greenhouse location.The heating coefficient of performances of the two ground-source heat pumps (COPHP,H–V) and the overall system (COPsys,H–V) were obtained to be in the range of 3.1–3.6 for HGSHP and 3.2–3.8 for VGSHP and 2.7–3.3 for HGSHP and 2.9–3.5 for VGSHP, respectively. Although significant savings are possible with these heating systems, a substantial investment in equipment and facilities may be required. The experimental results were obtained from November to April in heating seasons of 2007–2008. The results showed that the utilization of the ground-source heat pump is suitable for greenhouse heating in this district.  相似文献   

9.
This paper describes the experimental results obtained from the heat transfer in saturated nucleate boiling for the water/lithium bromide mixture flowing upward in a uniformly heated vertical tube, which is the generator of a solar absorption refrigeration system. The concentration range for the mixture was from 48 to 56 wt.% Plots of local and average heat transfer coefficients are shown against solution concentration, heat flux and the temperature difference between the wall tube and the fluid. It was observed that the average heat transfer coefficients increased for the mixture with an increase of the heat flux and with the decrease of the solution concentration and the temperature difference. The average heat transfer coefficients varied from 1.0 to 4.0 kW/m2 °C.  相似文献   

10.
In recent years, developing an energy efficient conventional heat pipe is more important because of the development of electronics and computer industries. To enhance the thermal performance of heat pipe, different nanofluids have been widely used. In this paper, an experimental investigation of heat transfer performance of heat pipe has been conducted using three different working fluids such as DI water, CuO nanofluid and TiO2 nanofluid. The heat pipe used in this study is made up of copper layered with two layers of screen mesh wick for better capillary action. The Parameters considered in this study are heat input, angle of inclination and evaporator fill ratio. The concentration of nanoparticle used in this study is of 1.0 wt.%. From the experimental results, comparisons of thermal performance were made between the heat pipes using various working fluids. Among various fill ratio charged, the heat pipe shows good thermal performance when it is operated at 75% fill ratio for all working fluids. However, the heat pipe operated with CuO nanofluid showed higher results compared with TiO2 nanofluid and DI water. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

11.
This research describes the development of a compression/absorption hybrid heat pump system that utilizes a mixture of NH3 and H2O as a working fluid. The heat pump cycle is based on a hybrid combination of vapor compression cycle and absorption cycle. The system consists of major components of two-stage compressors, absorbers, and a desorber. There are also auxiliary parts like a desuperheater, solution heat exchangers, a solution pump, a rectifier, and a liquid/vapor separator to support stable operation of the heat pump. This compression/absorption hybrid heat pump provides many advantages of performance over conventional vapor compression heat pumps including a large temperature glide, an improved temperature lift, a flexible operating range, and greater capacity control. These benefits are optimized by changing the composition of the mixture. In this study, the effect of the composition on the operating characteristics of the compression/absorption hybrid heat pump was experimentally observed.  相似文献   

12.
An experimental study of natural convection heat transfer in a differentially heated semicircular enclosure was carried out. The flat surface was heated and the radial surface was cooled isothermally. The effects of angle of enclosure inclination on the heat transfer across semicircular regions of several radii were measured for Rayleigh numbers RaR ranging from 6.72 × 106 to 2.33 × 108, using water as the working fluid. The angle of inclination varied from −90 degrees to 90 degrees with radii R of 50, 40, and 30 mm. The flow patterns were sketched from the results of a visualization experiment using aluminum powder. The temperature measurements in the enclosure were carried out using liquid crystals and thermocouples. The results indicate that different flow patterns were encountered as the angle of inclination varied, and the heat transfer rate was largely dependent on the flow pattern. In particular, enhanced heat transfer rates can be obtained when plume-like flow occurs along both hot and cold walls in the case of an upward-facing hot wall. Heat transfer for the inclined enclosure can be predicted using the equation for a vertical enclosure presented in this paper. © 1998 Scripta Technica, Inc. Heat Trans Jpn Res, 26(2): 131–142, 1997  相似文献   

13.
A novel indirect expansion solar-assisted multi-functional heat pump (IX-SAMHP) system which composes of the multi-functional heat pump system and solar thermal collecting system is proposed and studied in this paper. This system can fulfill space heating, space cooling and water heating with high energy efficiency by utilizing solar energy. For solar water heating mode and solar space heating mode, a dynamic model is presented and validated with the experimental results. The simulation results show good consistency with the experimental data, and the established model is able to predict the system performance at a reasonable accuracy (with the root mean square deviations less than 5%). On this basis, the performances of the IX-SAMHP system are investigated under different parametric conditions. For solar water heating mode, simultaneously operating the solar thermal collecting system and multi-functional heat pump system can be an energy efficiency method. With the solar irradiation rising from 0W/m2 to 800W/m2, the COP increases from 2.35 to 2.57. In solar space heating mode, the effect of the mass flow rate of water in evaporator is investigated. To balance the heating capacity and COP, the mass flow rate of water should be adjusted according to different temperature demands and heat load.  相似文献   

14.
The system performance of a ground source heat pump (HP) system is determined by the HP characteristics itself and by the thermal interaction between the ground and its borehole heat exchanger (BHE). BHE performance is strongly influenced by the thermal properties of the ground formation, grouting material, and BHE type. Experimental investigations on different BHE types and grouting materials were carried out in Belgium. Its performances were investigated with in situ thermal response tests to determine the thermal conductivity (λ) and borehole resistance (Rb). The line‐source method was used to analyze the results, and the tests showed the viability of the method. The main goal was to determine the thermal borehole resistance of BHEs, including the effect of the grouting material. The ground thermal conductivity was measured as 2.21 W m?1 K?1, a high value for the low fraction of water‐saturated sand and the high clay content at the test field. The borehole resistance for a standard coaxial tube with cement–bentonite grouting varied from 0.344 to 0.162 K W?1 m for the double U‐tube with cement–bentonite mixture (52% reduction). Grouting material based on purely a cement–bentonite mixture results in a high thermal borehole resistance. Addition of sand to the mixture leads to a better performance. The use of thermally enhanced grouts did not improve the performance significantly in comparison with only a low‐cost grouting material as sand. Potential future applications are possible in our country using a mobile testing device, such as characteristics, standardization, quality control, and certification for drilling companies and ground source HP applications, and in situ research for larger systems. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

15.
An innovative steam reformer for hydrogen production at temperatures lower than 550 °C has been developed in the EU project CoMETHy (Compact Multifuel-Energy To Hydrogen converter). The steam reforming process has been specifically tailored and re-designed to be combined with Concentrating Solar plants using “solar salts”: a low-temperature steam reforming reactor was developed, operating at temperatures up to 550 °C, much lower than the traditional process (usually > 850 °C). This result was obtained after extensive research, going from the development of basic components (catalysts and membranes) to their integration in an innovative membrane reformer heated with molten salts, where both hydrogen production and purification occur in a single stage. The reduction of process temperatures is achieved by applying advanced catalyst systems and hydrogen selective Pd-based membranes. Process heat is supplied by using a low-cost and environmentally friendly binary NaNO3/KNO3 liquid mixture (60/40 w/w) as heat transfer fluid; such mixture is commonly used for the same purpose in the concentrating solar industry, so that the process can easily be coupled with concentrating solar power (CSP) plants for the supply of renewable process heat. This paper deals with the successful operation and validation of a pilot scale reactor with a nominal capacity of 2 Nm3/h of pure hydrogen from methane. The plant was operated with molten salt circulation for about 700 h, while continuous operation of the reactor was achieved for about 150 h with several switches of operating conditions such as molten salts inlet temperature, sweep steam flow rate and steam-to-carbon feed ratio. The results obtained show that the membrane reformer allows to achieve twice as high a conversion compared to a conventional reformer operating at thermodynamic equilibrium under the same conditions considered in this paper. A highly pure hydrogen permeate stream was obtained (>99.8%), while the outlet retentate stream had low CO concentration (<2%). No macroscopic signs of reactor performance loss were observed over the experimental operation period.  相似文献   

16.
A heat source at temperatures not higher than 80°C was used to simulate the heat input to an absorption heat transformer from a solar pond. An experimental absorption heat transformer operated with the water/Carrol mixture was used to demonstrate the feasibility of these systems to increase the temperature of the heat obtained from the solar ponds. Carrol™ is a mixture of LiBr and ethylene glycol [(CH2OH)2] in the ratio 1:4.5 by weight. Flow ratios, gross temperature, useful heat, and coefficients of performance are plotted for the heat transformer versus temperature and solution concentration. Gross temperature as high as 50°C were obtained. The maximum temperature of the useful heat produced by the heat transformer was 132°C. The COP for the unit was in the range 0.14–0.36.  相似文献   

17.
We performed tests for heat storage-type floor heating that employs a heat pump driven with nighttime electric power for 8 h (11 PM to 7 AM) as the heat source. The phase change material (PCM) applied was a package of mirabilite (Na2SO4 · 10H2O). The melting point is 32 °C, the freezing point 30 °C, and the stored heat amount 43 W · h/kg (ΔT = 10 °C). The test room for floor heating was a wooden structure without windows, and the floor area was 40 m2. The hot water panel (5 mm in thickness, made of plastic, 26 m2) was laid on the stage (1.2 m in height) inside the room and the PCM was superimposed on the upper surface of the stage (the total stored heat amount was 28.5 kW). Since the heat pump runs in cycles of 8-h operation and 16-h nonoperation, it needs an extracted heat amount of three times compared with the case of round-the-clock operation. For this reason, we have developed a wet film-type vertical heat extracting tube with a built-in Freon flashing pump to obtain extracted heat about three times greater than was previously possible. We have calculated the heat balance from the results of the tests for floor heating and have studied the practicability of this system. © 1998 Scripta Technica, Inc. Heat Trans Jpn Res, 26(2): 122–130, 1997  相似文献   

18.
In this paper, a transcritical carbon dioxide heat pump system driven by solar‐owered CO2 Rankine cycle is proposed for simultaneous heating and cooling applications. Based on the first and second laws of thermodynamics, a theoretical analysis on the performance characteristic is carried out for this solar‐powered heat pump cycle using CO2 as working fluid. Further, the effects of the governing parameters on the performance such as coefficient of performance (COP) and the system exergy destruction rate are investigated numerically. With the simulation results, it is found that, the cooling COP for the transcritical CO2 heat pump syatem is somewhat above 0.3 and the heating COP is above 0.9. It is also concluded that, the performance of the combined transcritical CO2 heat pump system can be significantly improved based on the optimized governing parameters, such as solar radiation, solar collector efficient area, the heat transfer area and the inlet water temperature of heat exchange components, and the CO2 flow rate of two sub‐cycles. Where, the cooling capacity, heating capacity, and exergy destruction rate are found to increase with solar radiation, but the COPs of combined system are decreased with it. Furthermore, in terms of improvement in COPs and reduction in system exergy destruction at the same time, it is more effective to employ a large heat transfer area of heat exchange components in the combined heat pump system. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
水—水热泵替代工质循环性能及其动态可燃特性研究   总被引:3,自引:0,他引:3  
水-水热泵在建筑能量系统的环境保护,开发和利用余热资源中起着重要作用,为了研究这种热泵的工质替代问题,就目前具有成功实验结果的水-水热泵的替代工质之一:R32/134a进行热力学及循环性能模拟分析,结果发现R32/134a当浓度为(30/70)时作为常规水-水热泵工质具有较大的优势,针对此替代物在生产使用中的重要环节一贮存和运输中的安全性问题,研究其在贮运过程中由于泄漏引起的动态燃爆特性,得出了具有实际应用价值的规律。  相似文献   

20.
《Applied Thermal Engineering》2003,23(9):1153-1165
Capillary pumping two-phase loops have been continuously investigated for electronic cooling systems, satellite thermal control and other space applications. Most tests were performed in capillary evaporators using plastic or metallic porous wick as capillary structure and anhydrous ammonia as the working fluid. In this work, capillary pumping system assisting flat solar collectors is proposed as an alternative to residential and commercial water heating systems, using fine circumferential grooves as capillary structure and acetone as the working fluid. The experimental results are obtained for a small-scale solar heating system, using one capillary pump attached to a flat copper plate of 46 cm in length and 6 cm in width. The capillary pump consists of a 19 mm OD and 500 mm long aluminium tube, with fine internal circumferential groves as the capillary structure. The working fluid is pumped from a condenser designed to delivery heat to the water storage. Heat inputs up to 14 W (507 W/m2) were estimated for heating purpose. The system presented reliable start-ups and good performance in continuous operation. The measurements were found to be in good agreement with theoretical results for the temperature field and solar power absorbed by the system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号