共查询到20条相似文献,搜索用时 10 毫秒
1.
GJ Lane WJ Hozack S Shah RH Rothman RE Booth K Eng P Smith 《Canadian Metallurgical Quarterly》1997,(345):106-112
One hundred consecutive, primary simultaneous bilateral total knee arthroplasties were prospectively compared with 100 consecutive, primary unilateral total knee arthroplasties in reference to relative risk, complications, cost, and need for rehabilitation. All procedures were performed using identical preoperative, intraoperative, and postoperative protocols. Postoperative confusion was approximately four times greater in the simultaneous bilateral total knee arthroplasties group (29% versus 7%), which was thought to represent an increased incidence of fat embolism. Cardiopulmonary complications were approximately three times greater after simultaneous bilateral total knee arthroplasties (14% versus 5%), and most commonly involved arrhythmias. The increased stress on the cardiopulmonary system with simultaneous bilateral total knee arthroplasties may make this procedure contraindicated in certain patients with preexisting disease. There was an approximately 17 times greater need for banked blood in the simultaneous bilateral total knee arthroplasties group (17% versus 1%), which is alarming given the persistent concerns of transfusion related disease transmission. Although the length of hospitalization was similar (6.4 days simultaneous bilateral total knee arthroplasties versus 6 days unilateral total knee arthroplasty), 89% of the patients in the simultaneous bilateral total knee arthroplasties group required a rehabilitation stay versus 45% of the patients in the unilateral total knee arthroplasty group. Total hospital charges averaged $53,168 for simultaneous bilateral total knee arthroplasties versus $32,598 for unilateral total knee arthroplasty. Total rehabilitation charges were similar. The relative cost savings implicit by doing simultaneous bilateral total knee arthroplasties seem to be at least partially offset by the approximately two times greater need for rehabilitation in this group. The true safety, efficacy, relative risk, and total cost analysis of simultaneous bilateral total knee arthroplasties demands further critical evaluation. 相似文献
2.
A retrospective matched-pair comparative analysis was done between 30 total knee arthroplasties following failed high tibial osteotomies and 30 total knee arthroplasties following failed unicompartmental knee arthroplasties. The groups were matched according to age, gender, type of prosthesis, primary disease, and length of followup. A minimum followup of 2 years was required for inclusion in the study, and the average followup was 3.8 years (range, 2-9 years). The Knee Society Knee Score for the high tibial osteotomy group was significantly higher than that for the unicompartmental arthroplasty group. More osseous reconstructions were required in the unicompartmental revisions. Difficulty with exposure was not significantly greater in the osteotomy group. Rates of component loosening were not significantly different between the groups. A failed unicompartmental knee arthroplasty and a failed high tibial osteotomy can be revised successfully to a total knee arthroplasty. The results confirm that revisions after unicondylar arthroplasty and high tibial osteotomy are technically demanding. In this series, the results of total knee arthroplasty following unicompartmental knee arthroplasty approached but did not equal those obtained after high tibial osteotomy. 相似文献
3.
The authors report on a series of 15 knees in which an extensor mechanism allograft was used to treat a rupture of the patellar tendon associated with a total knee arthroplasty. Nine of the knees have greater than two-year follow-up evaluation (average, 4.1 years; range, 2.3-7 years). Postoperatively, the average flexion was 106 degrees. All but three patients achieved full passive extension. Six of the nine knees had no extensor lag. The average post-operative clinical score for the follow-up group was 78 points. Graft complications include one early graft rupture, one early quadriceps junction failure, and one patellar component loosening. One graft fractured after revision of a metal-backed patella. 相似文献
4.
Thirty patients with isolated patellofemoral complications after total knee arthroplasty were compared with 20 patients with well functioning total knee replacements without patellofemoral complications. The epicondylar axis and tibial tubercle were used as references on computed tomography scans to measure quantitatively rotational alignment of the femoral and tibial components. The group with patellofemoral complications had excessive combined (tibial plus femoral) internal component rotation. This excessive combined internal rotation was directly proportional to the severity of the patellofemoral complication. Small amounts of combined internal rotation (1 degree-4 degrees) correlated with lateral tracking and patellar tilting. Moderate combined internal rotation (3 degrees-8 degrees) correlated with patellar subluxation. Large amounts of combined internal rotational (7 degrees-17 degrees) correlated with early patellar dislocation or late patellar prosthesis failure. The control group was in combined external rotation (10 degrees-0 degree). The direct correlation of combined (femoral and tibial) internal component rotation to the severity of the patellofemoral complication suggests that internal component rotation may be the predominant cause of patellofemoral complications in patients with normal axial alignment. The epicondylar axis and tibial tubercle are reproducible landmarks which are visible on computed tomography scans and can be used intraoperatively. Using this computed tomography study can determine wether rotational malalignment is present and thus, whether revision of one or both components may be indicated. 相似文献
5.
Early results of 76 geometric total knee replacements were reviewed with assistance from computer analysis. A 92% patient follow-up for one to three years showed an overall satisfactory result with substantial improvement, especially in relief of severe pain. However, several problems are noted, including fractures beneath the tibial plateau and loosening. The long-term results are still unknown. The indications for total knee replacements should remain conservative until long-term results and experience have been achieved. 相似文献
6.
While peroneal and tibial neuropathies have been described as a complication of total knee arthroplasty (TKA), a computerized literature search failed to reveal any previously reported cases of associated sacral plexopathy or sciatic neuropathy. This case report describes the diagnosis and management of a patient found to have evidence of a right sacral plexopathy and a left sciatic neuropathy, following bilateral TKA. This case suggests that these may be rare complications of TKA. 相似文献
7.
FM Griffin GR Scuderi AM Gillis S Li E Jimenez T Smith 《Canadian Metallurgical Quarterly》1998,13(5):592-598
Osteolysis has not been mentioned as a complication or cause of failure of cemented total knee arthroplasties in long-term follow-up studies. We are aware of a single case report of osteolysis after cemented total knee arthroplasty. We report the case of an 87-year-old woman with massive osteolysis beneath a cemented tibial component. 相似文献
8.
The incidence of pulmonary embolism (PE) in osteoarthritic patients prophylaxed with low-dose coumadin after cemented total knee arthroplasty (TKA) was investigated prospectively. Each patient had a preoperative perfusion scan and a ventilation-perfusion scan on the seventh postoperative day. Pulmonary embolism was diagnosed by a high probability ventilation-perfusion scan or positive arteriogram. Patients with a moderate probability scan had an arteriogram to rule out PE. Pulmonary embolus was identified in 48 (5.6%) of 852 TKAs in 755 patients. Of these, six (0.7%) were symptomatic, and no fatal PE was identified. Age, gender, and weight did not show statistical differences comparing the PE and non-PE groups, nor did the incidences of previous PE, contralateral phlebitis, malignancy, and diabetes. A history of ipsilateral phlebitis increased the risk of PE from 5.2% to 13%, and a history of cardiac disease decreased the risk from 7.8% to 4.2%. Type of anesthesia, blood loss, tourniquet time, and prosthesis type were not significant factors. With the exception of previous contralateral phlebitis, traditional risk factors for PE were not found to increase risk of PE with low-dose coumadin prophylaxis. Spinal anesthesia that has been shown to be protective in total hip surgery was not a significant factor in this study. 相似文献
9.
PURPOSE: To compare the effects of preadmission and postadmission educational programs for patients with total knee arthroplasty. DESIGN: Quasiexperimental study. SAMPLE: 60 total knee arthroplasty patients. METHODS: Subjects in the experimental group received preadmission preoperative teaching with an instruction booklet during a preoperative outpatient clinic visit. Upon admission to the hospital, they were presented with an educational video tape. The control group received only postadmission preoperative teaching with the same instruction booklet and no video. PREADMISSION AND POSTADMISSION: Preoperative anxiety level, knowledge about postoperative care, exercise performance and postoperative recovery were used as outcome measures. FINDINGS: The research results found: 1. there was no significant difference between the two groups in reduction of preoperative anxiety score: 2. the experimental group had a significantly higher knowledge level than the control group; 3. the experimental group performed exercise more regularly and correctly than those in the control group; 4. the experimental group had greater flexion of the operative knee joint than the control group. CONCLUSION: Preadmission teaching with a videotape program and a health manual for patients with total knee arthroplasty is recommended. IMPLICATIONS FOR NURSING RESEARCH: More indicators such as postoperative pain and patient satisfaction can be used to investigate the effectiveness of intervention. In addition, increasing the sample size is recommended for future studies. 相似文献
10.
Between 1990 and 1995, 25 painful primary posterior cruciate ligament retaining total knee arthroplasties were revised for flexion instability. These patients shared typical clinical presentations that included a sense of instability without frank giving way, recurrent knee joint effusion, soft tissue tenderness involving the pes anserine tendons and the retinacular tissue, posterior instability of 2+ or 3+ with a posterior drawer or a posterior sag sign at 90 degrees flexion, and above average motion of their total knee arthroplasty. The primary total knee arthroplasty was performed for osteoarthritis in 23 patients and rheumatoid arthritis in two patients. There were 13 male and 12 female patients and their mean age was 65 years (range, 35-77 years). Before the revision operation, Knee Society knee scores averaged 45 points (range, 17-68 points) and function scores averaged 42 points (range, 0-60 points). Twenty-two of the knee replacements were revised to posterior stabilized implants and three underwent tibial polyethylene liner exchange only. Nineteen of the 22 knee replacements revised to a posterior stabilized implant were improved markedly after the revision surgery. Only one of three knee replacements that underwent tibial polyethylene exchange was improved. After the revision for flexion instability, Knee Society knee scores averaged 90 points (range, 82-99 points) and function scores averaged 75 points (range, 45-100 points) for the 20 knees with a successful outcome. This study suggests that flexion instability can be a cause of persistent pain and functional impairment after posterior cruciate ligament retaining total knee arthroplasty. A revision operation that focuses on balancing the flexion and extension spaces, in conjunction with a posterior stabilized knee implant, seems to be a reliable treatment for symptomatic flexion instability after posterior cruciate retaining total knee arthroplasty. 相似文献
11.
Heparin-induced thrombocytopenia is a rare drug reaction that can be associated with thrombotic complications leading to myocardial infarct, stroke, or ischemic loss of a limb. Because of the broadening indications of low-molecular-weight heparin use, the current emphasis on ambulatory care, and the difficulty in clinical diagnosis and treatment of this drug reaction, heparin-induced thrombocytopenia is the most important allergic drug reaction that physicians must manage. An antibody-mediated drug reaction to low-molecular-weight heparin that resulted in a below-knee amputation after an elective total knee arthroplasty is reported. 相似文献
12.
A novel cosalane analog having an extended polyanionic pharmacophore was synthesized in order to target specific cationic residues on the surface of CD4. The design rationale is based on a hypothetical binding model of cosalane to the surface of the protein. The new analog displayed an EC50 of 0.55 microM as an inhibitor of the cytopathic effect of HIV-1RF in CEM-SS cells, which represents a significant increase in potency over cosalane itself (EC50 5.1 microM). Both cosalane and the new analog are inhibitors of viral entry into target cells. 相似文献
13.
14.
Genome size was determined, by nuclear Feulgen staining and image analysis, in 46 accessions of 31 species of Peronosporales (Oomycota), including important plant pathogens such as Bremia lactucae, Plasmopara viticola, Pseudoperonospora cubensis, and Pseudoperonospora humuli. The 1C DNA contents ranged from 0.046 (45. 6 Mb) to 0.163 pg (159.9 Mb). This is 0.041- to 0.144-fold that of Glycine max (soybean, 1C = 1.134 pg), which was used as an internal standard for genome size determination. The linearity of Feulgen absorbance photometry method over this range was demonstrated by calibration of Aspergillus species (1C = 31-38 Mb) against Glycine, which revealed differences of less than 6% compared to the published CHEF data. The low coefficients of variation (usually between 5 and 10%), repeatability of the results, and compatibility with CHEF data prove the resolution power of Feulgen image analysis. The applicability and limitations of Feulgen photometry are discussed in relation to other methods of genome size determination (CHEF gel electrophoresis, reassociation kinetics, genomic reconstruction) that have been previously applied to Oomycota. 相似文献
15.
We hypothesized that a pattern of decreasing postoperative length of stay (LOS) in the hospital could lead to an increased rate of manipulation after total knee arthroplasty (TKA). The decision to manipulate is based on the patient's ability to perform normal physical activities, which may in large part be dependent on adequate knee flexion (ie, range of motion [ROM]). Decreased exposure to physical therapy (as a result of decreased LOS) may be a contributing factor leading to impaired functional ROM in the 6-week postoperative period. We examined records from 745 patients (2 surgeons) who had a primary TKA from 1993 to 1996. At our institution, development and implementation of clinical pathways resulted in a significant decrease in the average LOS beginning in 1993. The average LOS in 1993 was 6.4 +/- 1.8 days (mean +/- SD) and progressively decreased to 4.4 +/- 1.0 days in 1996 (P < .0001). The rate of manipulation (patients manipulated at 6 weeks/total number of patients receiving TKA) was 6.0% in 1993 and increased to 11.3% (P = .09) in 1994, 13.5% (P = .02) in 1995, and 12.0% (P = .05) in 1996. In the period 1993-1996, patients requiring manipulation consistently had a lower ROM at discharge from the hospital (69.0 +/- 10 degrees, n = 67, P < .0001) compared with patients not requiring manipulation (80.7 +/- 10.6 degrees, n = 542). The relatively low frequency and charge for manipulation may justify the decision to decrease patient exposure to physical therapy through reduction in LOS. As efforts to decrease LOS continue, however, we must aggressively manage patients and provide adequate exposure to inpatient and outpatient physical therapy to ensure optimal ROM results. 相似文献
16.
BT Holt NL Parks GA Engh JM Lawrence 《Canadian Metallurgical Quarterly》1997,20(12):1121-4; discussion 1124-5
One hundred thirty-six primary total knee arthroplasty patients were randomized for the use of closed-suction, nonreinfusable wound drains. Blood loss was identical in the drained and undrained groups. Forty percent of undrained wounds compared with 0% of drained wounds required dressing reinforcement. Sixty-nine percent of undrained wounds compared with 39% of drained wounds developed ecchymosis, measuring 92 cm2 in the undrained group and 28 cm2 in the drained group. This study concludes that a simple wound drain effectively minimizes the undesirable accumulation of blood in the surrounding soft tissues and the postoperative wound dressing after total knee arthroplasty. 相似文献
17.
T Otani K Fujii M Ozawa K Kaechi K Funaki T Matsuba H Ueno 《Canadian Metallurgical Quarterly》1998,13(5):589-591
A 57-year-old patient with rheumatoid arthritis showed posterolateral impingement after total knee arthroplasty. The radiographs showed bone cement extrusion posterolateral to the tibial tray. Arthrotomy through a posterolateral approach revealed that the impingement was caused not only by cement extrusion against the fibular head but also by proximal tibiofibular joint instability. It was speculated that rheumatoid arthritis had caused proximal tibiofibular instability, active knee motion had caused fibular head shift by tension of biceps femoris and the fibular head had been impinged on the extruded cement. In cementing the tibial tray, especially in a rheumatoid patient, it is of paramount importance to take caution against posterolateral cement extrusion in order to minimize the risk of fibular head impingement during total knee arthroplasty. 相似文献
18.
AT Berman JL Parmet SP Harding CL Israelite K Chandrasekaran JC Horrow R Singer H Rosenberg 《Canadian Metallurgical Quarterly》1998,80(3):389-396
We analyzed the genetic defect in a 67-year-old Japanese male patient with apolipoprotein (apo) A-I and high density lipoprotein (HDL) deficiencies, corneal opacities, and coronary artery disease. The plasma concentrations of apoA-I and HDL cholesterol were 2.9 to 7.3 mg/dL and 0.08 to 0.19 mmol/L, respectively. The lecithin:cholesterol acyltransferase (LCAT) activity and cholesterol esterification rate were <40% of normal control values. LCAT mass was 550% of normal control. Sequence analysis of polymerase chain reaction-amplified DNA of the proband's apoA-I gene showed a homozygous T-to-A transition resulting in the substitution of Val 156 with Glu (apoA-I Oita). Direct sequencing of samples obtained from other family members showed that the brother was homozygous, whereas the son was a heterozygous carrier of apoA-I Oita. The heterozygote for apo A-I Oita showed nearly 60% of normal apoA-I and normal HDL cholesterol levels. In vivo turnover studies in rabbits demonstrated that the variant apoA-I was rapidly cleared from plasma compared with normal human apoA-I. Our data suggest that the Val156Glu substitution is associated with apoA-I and HDL deficiency, partial LCAT deficiency, and corneal opacities and that Val156 of apoA-I may play an important role in apoA-I function. 相似文献
19.
20.
DA Dennis RD Komistek CE Colwell CS Ranawat RD Scott TS Thornhill MA Lapp 《Canadian Metallurgical Quarterly》1998,(356):47-57
A study was conducted to determine in vivo femorotibial contact patterns for subjects having a posterior cruciate retaining or posterior cruciate substituting total knee arthroplasty. Femorotibial contact of 72 subjects implanted with a total knee replacement, performed by five surgeons, was analyzed using video fluoroscopy. Thirty-one subjects were implanted with a posterior cruciate retaining total knee replacement with a flat polyethylene posterior lipped insert, 12 with a posterior cruciate retaining total knee replacement with a curved insert, and 29 with a posterior cruciate substituting total knee replacement. Each subject performed successive deep knee bends to maximum flexion. Video images at 0 degree, 30 degrees, 60 degrees, and 90 degrees flexion were downloaded onto a workstation computer. Femorotibial contact paths were determined for the medial and lateral condyles using an interactive model fitting technique. Femorotibial contact anterior to the tibial midline in the sagittal plane was denoted as positive and contact posterior was denoted as negative. Analysis of average femorotibial contact pathways of both posterior cruciate retaining designs revealed posterior femorotibial contact in full extension with anterior translation of femorotibial contact commonly observed in midflexion and terminal flexion. In posterior cruciate substituting designs, anterior femoral translation was seen medially at 30 degrees to 60 degrees flexion but rarely was observed laterally. Posterior femoral rollback laterally from full extension to 90 degrees flexion was seen in 100% of subjects implanted with a posterior cruciate substituting total knee replacement, versus 51.6% (posterior lipped polyethylene insert) and 58.3% (curved insert) of those with a posterior cruciate retaining total knee replacement. Data from this multicenter study are remarkably similar to previous fluoroscopy data from a single surgeon series, showing a lack of customary posterior femoral rollback in both posterior cruciate retaining designs, and conversely showing an average anterior femoral translation with knee flexion. Posterior femoral rollback, less than in normal knees, routinely was observed in posterior cruciate substituting total knee arthroplasty, attributed to engagement of the femoral component cam with the tibial post. The abnormal anterior femoral translation observed in posterior cruciate retaining total knee arthroplasty may be a factor in premature polyethylene wear observed in retrieval studies. 相似文献