首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The composition, stoichiometry, and organization of protein complexes can be determined by collision-induced dissociation (CID) coupled to tandem mass spectrometry (MS/MS). The increased use of this approach in structural biology prompts a better understanding of the dissociation mechanism(s). Here we report a detailed investigation of the CID of two dodecameric, heat-stable and toroidally shaped complexes: heat shock protein 16.9 (HSP16.9) and stable protein 1 (SP-1). While HSP16.9 dissociates by sequential loss of unfolded monomers, SP-1 ejects not only monomers, but also its building blocks (dimers), and multiples thereof (tetramers and hexamers). Unexpectedly, the dissociation of SP-1 is strongly charge-dependent: loss of the building blocks increases with higher charge states of this complex. By combining MS/MS with ion mobility (IM-MS/MS), we have monitored the unfolding and dissociation events for these complexes in the gas phase. For HSP16.9 unfolding occurs at lower energies than the ejection of subunits, whereas for SP-1 unfolding and dissociation take place simultaneously. We consider these results in the light of the structural organization of HSP16.9 and SP-1 and hypothesize that SP-1 is unable to unfold extensively due to its particular quaternary structure and unusually high charge density. This investigation increases our understanding of the factors governing the CID of protein complexes and moves us closer to the goal of obtaining structural information on subunit interactions and packing from gas-phase experiments.  相似文献   

2.
It remains an open question as to whether experiments involving collision-induced dissociation (CID) can provide a viable approach for monitoring spatially resolved deuteration levels in electrosprayed polypeptide ions. A number of laboratories reported the successful application of CID following solution-phase H/D exchange (HDX), whereas others found that H/D scrambling precluded site-specific measurements. The aim of the current work is to help clarify the general feasibility of HDX-CID methods, using a 22-residue zinc-bound protein domain (Zn-ZBD) as model system. Metal binding in Zn-ZBD should confer structural rigidity, and the presence of several basic residues should sequester mobile charge carriers in the gas phase. Both of these factors were expected to suppress the extent of scrambling. HDX was carried out by employing rapid on-line mixing, thereby mimicking conditions typically encountered in kinetic pulse-labeling studies. Quadrupole time-of-flight MS/MS of pulse-labeled Zn-ZBD provides high sequence coverage. However, the measured fragment deuteration levels do not correlate with the known H-bonding pattern of Zn-ZBD, suggesting the occurrence of extensive scrambling. Instead of showing a uniform distribution, the fragment ions reveal a distinct nonrandom pattern of deuteration levels. In the absence of prior information, these data could erroneously be ascribed to the presence of protected sites. However, the observed patterns clearly originate from other factors; possibly they are caused by modulations of the amide CID efficiency by kinetic isotope effects. It is concluded that scrambling does not represent the only conceptual problem in HDX-CID studies and that control experiments on uniformly labeled samples are essential for ruling out interpretation artifacts.  相似文献   

3.
There is an ongoing debate whether collision-induced dissociation (CID) of electrosprayed proteins after solution-phase hydrogen/deuterium exchange (HDX) is a viable approach for determining spatially resolved deuteration patterns. This work explores the use of two methods, source-CID and hexapole tandem mass spectrometry (MS/MS) on a quadrupole time-of-flight (Q-TOF) mass spectrometer, for measuring the fragment deuteration levels of regioselectively labeled ubiquitin. Both methods reveal that b-ions exhibit HDX levels significantly below that of the intact protein, whereas several y' fragments are labeled to a much greater extent. These results are consistent with earlier source-CID data (Akashi, S.; Naito, Y.; Takio, K. Anal. Chem. 1999, 71, 4974-4980). However, the measured b-ion deuteration levels are in disagreement with the known solution-phase behavior of ubiquitin. Partial agreement is observed for y'-ions. Control experiments on homogeneously labeled ubiquitin (having the same average deuteration level at every exchangeable site) result in highly nonuniform fragment HDX levels. In particular, b-ions exhibit deuteration levels significantly below that of intact ubiquitin, thereby mimicking the behavior seen for the regioselectively labeled protein. This effect is likely caused by isotope fractionation during collisional activation, facilitated by the high mobility of charge carriers (scrambling) in the gas phase. The observation that the b-ion labeling behavior is largely independent of the spatial isotope distribution within solution-phase ubiquitin invalidates these ions as reporters of the protein deuteration pattern. This work questions the common practice of interpreting any nonuniformities in fragment deuteration as being indicative of regioselective solution-phase labeling. Artifactual deuterium enrichment or depletion during collisional activation may have contributed to the current lack of consensus as to whether HDX/CID represents a potentially viable tool for measuring solution-phase deuteration patterns.  相似文献   

4.
The epitopes of a homohexameric food allergen protein, cashew Ana o 2, identified by two monoclonal antibodies, 2B5 and 1F5, were mapped by solution-phase amide backbone H/D exchange (HDX) coupled with Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) and the results were compared to previous mapping by immunological and mutational analyses. Antibody 2B5 defines a conformational epitope, and 1F5 defines a linear epitope. Intact murine IgG antibodies were incubated with recombinant Ana o 2 (rAna o 2) to form antigen-monoclonal antibody (Ag-mAb) complexes. mAb-complexed and uncomplexed (free) rAna o 2 were then subjected to HDX. HDX instrumentation and automation were optimized to achieve high sequence coverage by protease XIII digestion. The regions protected from H/D exchange upon antibody binding overlap and thus confirm the previously identified epitope-bearing segments: the first extension of HDX monitored by mass spectrometry to a full-length antigen-antibody complex in solution.  相似文献   

5.
Serum albumin proteins, Mr approximately 66 kDa, from 10 different species (bovine, human, rat, horse, sheep, goat, rabbit, dog, porcine, and guinea pig) have been studied by electrospray ionization mass spectrometry (ESI-MS) and tandem MS using a triple-quadrupole instrument. The effectiveness of collisional activation for the multiply charged albumin ions greatly exceeds that for singly charged ions, allowing an extension by a factor of at least 20 to the molecular mass range for obtaining sequence-specific product ions by tandem MS. Efficient dissociation is largely attributed to "preheating" in the interface Coulombic instability and the large number of collisions. Increasing the electric field in the intermediate pressure region, between the nozzle-skimmer elements of the atmospheric pressure/vacuum interface, allows fragmentation of the multiply protonated (to 96+) molecules produced by ESI. The most abundant dissociation product ions assigned have a low charge state (2+ to 5+) and are attributed to "bn" mode species from cleavage of the -CO-N- peptide backbone bonds. Particularly abundant dissociation products originate from regions near residues n = 20-25 from the NH2 terminus for parent ions of moderate charge (approximately 50+). Collisionally activated dissociation (CAD) mass spectra from porcine serum albumin, in contrast to the other albumins, also gave prominent singly charged "yn" fragments formed from cleavages near the COOH terminus. Tandem mass spectrometry (MS/MS) of the multiply charged molecular ions, and of fragment species produced by dissociation in the interface (i.e., effective MS/MS/MS), produced similar "bn" species and served to confirm spectral assignments. We also show that ESI mass spectra allow a qualitative assessment of protein microheterogeneity and, in some cases, resolution of major contributions. The physical and analytical implications of the results are discussed, including the identification of possible errors in previously published sequences.  相似文献   

6.
Nguyen A  Moini M 《Analytical chemistry》2008,80(18):7169-7173
The separation and detection of the major protein-protein and protein-metal complexes of erythrocytes directly from cell lysate under native conditions has been accomplished for the first time using capillary electrophoresis electrospray ionization-mass spectrometry (CE/ESI-MS). All three major protein-protein and protein-metal complexes in human red blood cells (RBCs) with a concentration dynamic range of approximately 3 orders of magnitude were successfully detected. Intact complexes detected in lysed RBCs included carbonic anhydrase II (CAII-Zn at approximately 0.8 amol/cell) complexed with its zinc cofactor, carbonic anhydrase I (CAI-Zn at approximately 7 amol/cell) complexed with its zinc cofactor, and hemoglobin A (Hb-tetramer at approximately 450 amol/cell)a tetramer formed by two alpha-beta-subunits and four heme groups. The average molecular weights measured for these complexes were consistent with their theoretical values within 0.01% mass accuracy. The use of Polybrene as a self-coating reagent in conjunction with ammonium acetate at pH approximately 7.4, narrow capillary for high separation efficiency, and forward polarity CE to avoid acid production at the tip of the capillary were overriding experimental factors for successful analysis of protein complexes. Diluting the lysed blood sample in ammonium acetate for a minimum of 6 h before injecting the sample into the CE was essential for obtaining the mass accuracy consistent with their theoretical average molecular weights. At physiological pH, the mass spectrum of the electrophoretic peak of Hb-tetramer included a small amount of the monomers and Hb-dimer. The migration time and peak profile of these species were almost identical to that of the tetramer, indicating that they are formed from decomposition of the Hb-tetramer during the ESI process. A separate electrophoretic peak for the Hb-dimer was only detected when the pH of the BGE was lowered from 7.4 to approximately 6.6. Running CE in forward polarity mode was essential for detection of the intact Hb-tetramer as well as CAI-Zn and CAII-Zn complexes. Under forward polarity mode, CE outlet/ESI shared electrode acts as the cathode of the CE circuit and the anode (positive voltage for positive ions) of the ESI circuit, thereby maintaining approximately neutral pH at the CE outlet/ESI electrode. In addition, under forward polarity mode, CAII-Zn and CAI-Zn migrated ahead of Hb-tetramer, avoiding being masked by 562x and 64x, respectively, molar excess of Hb-tetramer.  相似文献   

7.
The overall structure of a protein-protein complex reflects an intricate arrangement of noncovalent interactions. Whereas intramolecular interactions confer secondary and tertiary structure to individual subunits, intermolecular interactions lead to quaternary structure--the ordered aggregation of separate polypeptide chains into multisubunit assemblies. The specific ensemble of noncovalent contacts dictates the stability of subunit folds, enforces protein-protein binding specificity, and determines multimer stability. Consequently, noncovalent architecture is likely to play a role in the gas-phase dissociation of these assemblies during tandem mass spectrometry (MS/MS). To further advance the applicability of MS/MS to analytical problems in structural biology, a better understanding of the interplay between the structures and fragmentation behaviors of noncovalent protein complexes is essential. The present work constitutes a systematic study of model protein homodimers (bacteriophage N15 Cro, bacteriophage λ Cro, and bacteriophage P22 Arc) with related but divergent structures, both in terms of subunit folds and protein-protein interfaces. Because each of these dimers has a well-characterized structure (solution and/or crystal structure), specific noncovalent features could be correlated with gas-phase disassembly patterns as studied by collision-induced dissociation, surface-induced dissociation, and ion mobility. Of the several respects in which the dimers differed in structure, the presence or absence of intermolecular electrostatic contacts exerted the most significant influence on the gas-phase dissociation behavior. This is attributed to the well-known enhancement of ionic interactions in the absence of bulk solvent. Because salt bridges are general contributors to both intermolecular and intramolecular stability in protein complexes, these observations are broadly applicable to aid in the interpretation or prediction of dissociation spectra for noncovalent protein assemblies.  相似文献   

8.
The recently discovered homochiral serine octamer has been a focus of interest because of its possible implications for the origin of homochirality in living systems. Electrospray ionization (ESI) and sonic spray ionization (SSI) tandem mass spectrometry have been used to generate this unusually stable magic number cluster. Several structures have been suggested for the serine octamer, based on tandem mass spectrometry, ion mobility measurements, and quantum mechanical calculations. We now report experimental hydrogen/deuterium (H/D) exchange data, which demonstrate the existence of two different structures for the serine octamer. These forms undergo exchange at significantly different rates. One form may correspond to solution-phase assembled clusters and the other to octamers formed during the ionization process. Experiments done at higher resolution confirm that the experimental observations made here apply to the serine octamer without interference from metaclusters, namely, higher order clusters (Ser(16) + 2H)(+2), etc., the (12)C isotopes of which have mass-to-charge ratios identical to the protonated octamers. H/D exchange of racemic serine shows predominantly the extensively exchanged ion population, as well as providing evidence that racemic serine generates abundant metaclusters. The evidence presented here shows that one type of serine octamer is responsible for the strong chiral effects associated with the formation of these magic number clusters. These slowly exchanging more fragile clusters are the octamers that might have played a role in homochirogenesis.  相似文献   

9.
A custom in-line surface-induced dissociation (SID) device has been incorporated into a commercial ion mobility quadrupole/time-of-flight mass spectrometer in order to provide an alternative and potentially more informative activation method than the commonly used collision-induced dissociation (CID). Complicated sample mixtures can be fractionated by ion mobility (IM) and then dissociated by CID or SID for further structural analysis. Interpretation of SID spectra for cesium iodide clusters was greatly simplified with IM prior to dissociation because products originating from different precursors and overlapping in m/z but separated in drift time can be examined individually. Multiple conformations of two protein complexes, source-activated transthyretin tetramer and nativelike serum amyloid P decamer, were separated in ion mobility and subjected to CID and SID. CID spectra of the mobility separated conformations are similar. However, drastic differences can be observed for SID spectra of different conformations, implying different structures in the gas phase. This work highlights the potential of utilizing IM-SID to study quaternary structures of protein complexes and provides information that is complementary to our recently reported SID-IM approach.  相似文献   

10.
Zhang Z  Zhang A  Xiao G 《Analytical chemistry》2012,84(11):4942-4949
Protein hydrogen/deuterium exchange (HDX) followed by protease digestion and mass spectrometric (MS) analysis is accepted as a standard method for studying protein conformation and conformational dynamics. In this article, an improved HDX MS platform with fully automated data processing is described. The platform significantly reduces systematic and random errors in the measurement by introducing two types of corrections in HDX data analysis. First, a mixture of short peptides with fast HDX rates is introduced as internal standards to adjust the variations in the extent of back exchange from run to run. Second, a designed unique peptide (PPPI) with slow intrinsic HDX rate is employed as another internal standard to reflect the possible differences in protein intrinsic HDX rates when protein conformations at different solution conditions are compared. HDX data processing is achieved with a comprehensive HDX model to simulate the deuterium labeling and back exchange process. The HDX model is implemented into the in-house developed software MassAnalyzer and enables fully unattended analysis of the entire protein HDX MS data set starting from ion detection and peptide identification to final processed HDX output, typically within 1 day. The final output of the automated data processing is a set (or the average) of the most possible protection factors for each backbone amide hydrogen. The utility of the HDX MS platform is demonstrated by exploring the conformational transition of a monoclonal antibody by increasing concentrations of guanidine.  相似文献   

11.
A superior approach involving nano-high-performance liquid chromatography (nano-HPLC) in on-line conjunction to electrospray ionization quadrupole time-of-flight mass spectrometry (ESI QTOF MS) and tandem MS for screening and structural characterization of complex mixtures of neutral glycosphingolipids (GSLs) is here described. Neutral GSLs purified from human erythrocytes were efficiently separated according to the differences in carbohydrate chain length by an optimized nano-HPLC protocol and flow-through detected by ESI QTOF MS at the low femtomole level. Additionally, GSL species were accurately distinguished from the accompanying lipids in the mixture, thus permitting the determination of detailed structural characteristics by data-dependent analysis for identification of GSL constitution within single experiments. An alternative nano-HPLC/ESI QTOF MS approach was designed for dissection of unsaturation/saturation degree of the ceramide moieties defining the hydrophobic portion of GSLs and subsequent localization by nano-HPLC/ESI QTOF MS/MS of the -CH=CH- within the ceramide regions. The method is fast, highly sensitive, and high-throughput amenable and is highlighted as a new and valuable analytical dimension in glycolipidomics.  相似文献   

12.
Electrospray ionization (ESI) tandem mass spectrometry (MS/MS) of peptides in conjunction with automated sequence database searching of the resulting collision-induced dissociation (CID) spectra has become a powerful method for the identification of purified proteins or the components of protein mixtures. The success of the method is critically dependent on the manner by which the peptides are introduced into the mass spectrometer. In this report, we describe a capillary electrophoresis-based system for the automated, sensitive analysis of complex peptide mixtures. The system consists of an ESI-MS/MS instrument, a solid-phase extraction (SPE)-capillary zone electrophoresis (CZE) device for peptide concentration and separation, and an algorithm written in Instrument Control Language (ICL) which modulates the electrophoretic conditions in a data-dependent manner to optimize available time for the generation of high-quality CID spectra of peptides in complex samples. We demonstrate that the data-dependent modulation of the electric field significantly expands the analytical window for each peptide analyzed and that the sensitivity of the SPE-CZE technique is not noticeably altered by the procedure. By applying the technique to the analysis of in vivo phosphorylation sites of endothelial nitric oxide synthase (eNOS), we demonstrate the power of this system for the MS/MS analysis of minor peptide species in complex samples such as phosphopeptides generated by the proteolytic digestion of a large protein, eNOS, phosphorylated at low stoichiometry.  相似文献   

13.
Kim KH  Moon MH 《Analytical chemistry》2011,83(22):8652-8658
A chip-type design asymmetrical flow field-flow fractionation (AF4) channel has been developed for high-speed separation of proteins and top-down proteomic analysis using online coupled electrospray ionization mass spectrometry (ESI-MS). The new miniaturized AF4 channel was assembled by stacking multilayer thin stainless steel (SS, 1.5 mm each) plates embedded with an SS frit in such a way that the total thickness of the channel assembly was about 6 mm. The efficiency of the miniaturized AF4 channel at different channel lengths was examined with the separation of protein standards by adjusting flow rates in which an identical effective channel flow rate or an identical void time can be maintained at different channels. Detection limit, overloading effect, reproducibility, and influence of channel membrane materials on separation efficiency were investigated. Desalting and purification of proteins achieved during the AF4 operation by the action of an exiting crossflow and the use of aqueous mass-spectrometry-compatible (MS-compatible) buffer were advantageous for online coupling of the chip-type AF4 with ESI-MS. The direct coupling of AF4 and ESI-MS capabilities was demonstrated for the high-speed separation and identification of carbonic anhydrase (29 kDa) and transferrin (78 kDa) by full scan MS and for the first top-down identification of proteins with AF4-ESI-MS-MS using collision-induced fragmentation (CID). The presence of intact dimers (156 kDa) of transferrin was confirmed by AF4-ESI-MS via size separation of the dimers from monomers, followed by multiply charged ion spectral analysis of the dimers and molecular mass determinations. It was also found from these experiments that AF4-ESI-MS analysis of transferrin exhibited an increased signal-to-noise ratio compared to that of direct ESI-MS analysis due to online purification of the protein sample and size separation of dimers with AF4.  相似文献   

14.
The large-scale identification of proteins from proteomes of complex organisms, and the availability of various types of protein and DNA databases, increasingly require the additional information provided by tandem mass spectrometry. HPLC and microLC coupled to ESI-MS/MS presently dominate the field of protein identification by tandem mass spectrometry and database searching. The analysis of protein digests is typically performed using HPLC or LC columns with 50-100-microm diameters, requiring the delivery of solvent gradients at low to mid nanoliter per minute flow rates. This has been typically achieved using expensive generic HPLC pumping systems for the delivery of microliter per minute gradients that were either flow-split or sampled. Here we present an alternative system for the delivery of nanoliter per minute gradients. The inexpensive nanoflow gradient generator (etagrad) described here can be modulated to reproducibly deliver selected gradients. The performance of the etagrad on-line with a microLC-ESI-MS/MS system has been demonstrated for the identification of standard protein digests. Moreover, the performance of the etagrad-microLC-ESI-MS/MS system, with protein prefractionation by IPG isoelectric focusing, was also evaluated for rapid study of yeast and human proteomes.  相似文献   

15.
Li Y  George EJ 《Analytical chemistry》2005,77(14):4453-4458
A new method was developed for the analysis of perchlorate in water by using reversed-phase liquid chromatograhy/electrospray ionization-mass spectrometry/mass spectrometry (LC/ESI-MS/MS) in the negative ESI mode. Selective and sensitive perchlorate detection was obtained by monitoring the 35ClO4- --> 35ClO3- and 37ClO4- --> 37ClO3- mass transitions. The 35ClO4- --> 35ClO3- transition was quantitated against the internal standard oxygen-labeled sodium perchlorate (NaCl18O4). Sample pretreatment for the removal of major common anions and dissolved metal ions along with internal standard quantitation sufficiently compensated for ion suppression caused by the matrix. The 37ClO4- --> 37ClO3- transition was examined to provide additional specificity. The method sensitivity, accuracy, and precision were investigated by analyzing fortified blank samples, field samples, and performance evaluation samples. The results (1.01-13.5 microg/L) for the proficiency evaluation samples differed from the certified values (1.04-14.1 microg/L) by 3-18%. The developed reversed-phase LC/ESI-MS/MS method was rapid, accurate, and reproducible. The calculated method detection limits were 0.007 microg/L for deionized reagent water and 0.009 microg/L for synthesized reagent water, respectively. The minimum reporting limit was conservatively set to 0.05 microg/L.  相似文献   

16.
ESI FTICR mass spectrometry is the only technique currently used for accurate molecular weight analysis of PCR products above 100 bp in size. This is important in demonstrating the potential for MS in making major contributions in the molecular biology and genomics areas. In the near future, it is more likely that less expensive, more user friendly MS techniques will be used for high-throughput analyses (including MALDI TOF and ESI quadrupole). There have been numerous reports on the use of MALDI TOF. The current report is to the first to evaluate the use of ESI-quadrupole analysis of PCR products. Synthetic oligonucleotides (30 and 89 mers) and polymerase chain reaction products of varying molecular weight (62, 88, 89, and 114 bp) were analyzed by ESI using a quadrupole MS. The mass accuracy for nucleic acids in the 30-62 bp range was shown to allow determination of nucleotide substitutions and additions/deletions. For higher molecular weight PCR products (88-114 bp), the mass accuracy of ESI-MS distinguishes single or multiple nucleotide insertions/deletions. In addition, ESI quadrupole MS allows determination of molecular weight of both strands of higher molecular weight ds PCR products and can distinguish nucleotide modifications (e.g., with biotin). In conclusion, it is demonstrated that ESI-MS occupies an intermediate position (as compared to MALDI TOF and ESI FTICR) with regard to mass accuracy and resolution in analysis of nucleic acids.  相似文献   

17.
A commercial quadrupole/time-of-flight (QqTOF) tandem mass spectrometer has been adapted for ion/ion reaction studies. To enable mutual storage of oppositely charged ions in a linear ion trap, the oscillating quadrupole field of the second quadrupole of the system (Q2) serves to store ions in the radial dimension while auxiliary radio frequency is superposed on the end lenses of Q2 during the reaction period to create barriers in the axial dimension. A pulsed dual electrospray (ESI) source is directly coupled to the instrument interface for the purpose of proton transfer reactions. Singly and doubly charged protein ions as high in mass as 66 kDa are readily formed and observed after proton-transfer reactions. For the modified instrument, the mass resolving power is approximately 8000 for a wide m/z range, and the mass accuracy is approximately 20 ppm for external calibration and approximately 5 ppm for internal calibration after ion/ion reactions. Parallel ion parking is demonstrated with a six-component protein mixture, which shows the potential application of reducing spectral complexity and concentrating certain charge states. The current system has high flexibility with respect to defining MS(n) experiments involving collision-induced dissociation (CID) and ion/ion reactions. Protein precursor and CID product masses can be determined with good accuracy, providing an attractive platform for top-down proteomics. Electron transfer dissociation ion/ion reactions are implemented by using a pulsed nano-ESI/atmospheric pressure chemical ionization dual source for ionization. The reaction between protonated peptide ions and radical anions of 1,3-dinitrobenzene formed exclusively c- and z-type fragment ions.  相似文献   

18.
We modified and optimized a first generation quadrupole time-of-flight (Q-TOF) 1 to perform tandem mass spectrometry on macromolecular protein complexes. The modified instrument allows isolation and subsequent dissociation of high-mass protein complexes through collisions with argon molecules. The modifications of the Q-TOF 1 include the introduction of (1) a flow-restricting sleeve around the first hexapole ion bridge, (2) a low-frequency ion-selecting quadrupole, (3) a high-pressure hexapole collision cell, (4) high-transmission grids in the multicomponent ion lenses, and (5) a low repetition rate pusher. Using these modifications, we demonstrate the experimental isolation of ions up to 12 800 mass-to-charge units and detection of product ions up to 38 150 Da, enabling the investigation of the gas-phase stability, protein complex topology, and quaternary structure of protein complexes. Some of the data reveal a so-far unprecedented new mechanism in gas-phase dissociation of protein oligomers whereby a tetramer complex dissociates into two dimers. These data add to the current debate whether gas-phase structures of protein complexes do retain some of the structural features of the corresponding species in solution. The presented low-cost modifications on a Q-TOF 1 instrument are of interest to everyone working in the fields of macromolecular mass spectrometry and more generic structural biology.  相似文献   

19.
The capability for sensitive and accurate identification of microorganisms has potential applications that include the monitoring of industrial bioprocessing operations, food safety analyses, disease diagnosis, and detection of potential biological hazards. Efforts based upon matrix-assisted laser desorption/ionization mass spectrometry to detect and identify specific microorganisms have been actively pursued for several years. We report a new method being developed to select useful biomarkers for the identification of microorganisms based upon electrospray ionization (ESI)-ion trap mass spectrometry. Crude cell lysates are processed using a recently developed dualmicrodialysis device and then directly infused into an ion trap MS. The low ESI flow rate and precursor ion accumulation capability of the ion trap MS enables high-sensitivity MS/MS analyses. Precursor ions are automatically selected and analyzed using tandem MS (MS/MS) to produce "global" MS/MS surveys and processed to yield two-dimensional MS/MS spectral displays. Such global MS/MS surveys are demonstrated for Escherichia coli lysates. The distinctive MS/MS spectral patterns can be used to identify mass spectrometric-detected species useful as biomarkers, which then provide a basis for confident microorganism identification. The results presented demonstrate the application of this method for the identification of microorganisms, as well as for detection of bacteriophage MS2 in the presence of a large excess of E. coli.  相似文献   

20.
ESI (electrospray ionization) MS and tandem mass spectrometry (MS/MS) were used for the analysis of single nucleotide polymorphisms (SNPs) and more complex genetic variations. Double-stranded (ds) PCR products were studied. PCR products of the proline [5'-x(G17)-x(C38)x-3'] and arginine variants [(5'-x(Gl7)-x(G38)x-3'] of the p53 gene are distinguished by an SNP (cytosine or guanine) and were discriminated using both quadrupole and quadrupole ion trap MS analysis. A 69 bp arginine mutant PCR product [5'-x(C17)-x(G38)x-3'] with a negating switch has the same mass as the proline variant but was readily distinguishable on ion trap MS/MS analysis; fragments containing the mutation site, but not the polymorphism, were identified. The 69 bp PCR products were restriction-enzyme-digested, to create 43 bp fragments. ESI quadrupole ion trap MS/MS analysis of the 43 bp product-ion spectra readily demonstrated both polymorphism and negating switch sites. MS and MS/MS are powerful and complementary techniques for analysis of DNA. MS can readily distinguish SNPs but MS/MS is required to differentiate isomeric PCR products (same nucleotide composition but different sequence).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号