1.
The Harshaw TLD system has three key calibration procedures: the Reader, the Dosemeter and the Algorithm. These functions must be properly calibrated for the system to achieve the optimum results. For the conventional reader and dosemeter calibration, Harshaw TLD recommends a pre-fade and a post-fade of 24-48 h when calibrating the system for LiF:Mg,Ti type dosemeter. It is also recommended that keeping the fade time consistent is important to maintain the quality of the system performance. In recent years, new calibration features have been introduced into the Harshaw TLD models 6600 and 8800 operating systems. These new features are Auto Calibration, Auto QC and Auto Blank, and they give the user the ability to set up the clear-expose-read process to be performed automatically in a sequence for each dosemeter. This saves processing time and keeps the fade time the same. However, since the fade time is near zero, will it affect the TLD system calibration factors? What should the user expect? This paper presents a study of the effect of Auto Calibration/Auto QC to the TLD operation.  相似文献   

2.
An up-to-date microprocessor controlled thermoluminescence dosemeter (TLD) system for environmental and space dose measurements has been developed. The earlier version of the portable TLD system, Pille, was successfully used on Soviet orbital stations as well as on the US Space Shuttle, and for environmental monitoring. The new portable TLD system, Pille'95, consists of a reader and TL bulb dosemeters, and each dosemeter is provided with an EEPROM chip for automatic identification. The glow curve data are digitised and analysed by the program of the reader. The measured data and the identification number appear on the LED display of the reader. Up to several thousand measured data together with the glow curves can be stored on a removable flash memory card. The whole system is supplied either from built-in rechargeable batteries or from the mains of the space station.  相似文献   

3.
The Harshaw Model 6600 Plus is a reader with a capacity for 200 TLD cards or 800 extremity cards. The new unit integrates more functionality, and significantly automates the QC and calibration process compared to the Model 6600. The Model 6600 Plus was tested against the IEC 61066 (1991-2012) procedures using Harshaw TLD-700H and TLD-600H, LiF:Mg,Cu,P based TLD Cards. An overview of the type testing procedures is presented. These include batch homogeneity, detection threshold, reproducibility, linearity, self-irradiation, residue, light effects on dosemeter, light leakage to reader, voltage and frequency, dropping and reader stability. The new TLD reader was found to meet all the IEC criteria by large margins and appears well suited for whole body, extremity and environmental dosimetry applications, with a high degree of dosimetric performance.  相似文献   

4.
In India, approximately 58,000 radiation workers are monitored using locally made CaSO4:Dy teflon embedded thermoluminescence dosemeter (TLD) badge system. The automatic hot gas readers developed locally are also used in TL measurements. The hot gas reader system has many advantages over the manual readers used previously and has completely replaced the manual reader system in all TLD personnel monitoring units in India. In the present study, the new reader system is studied and a theoretical attempt has been made to interpret the experimentally obtained results. The glow curves are generated theoretically and are also plotted experimentally. It has been found that the heat capacity of the heating gas, which is responsible for the transfer of heat, has a role in deciding the position of peak and is verified experimentally using different gas flow rates of nitrogen and argon as heating gases in the reader. The theoretical study may also be helpful in fitting the experimentally obtained glow curves and, therefore, the elimination of unwanted non-radiation-induced contributions, such as dark current, electronic spikes, light leakage and triboluminescence that generally distort the glow curve shape, can be achieved.  相似文献   

5.
This work intends to identify and follow up quality control parameters important for the general improvement of our thermoluminescence dosemeter (TLD) system for Individual Monitoring that is currently preparing its accreditation according to the EN ISO/IEC 17025 Standard. A retrospective analysis of the readers' start-up tests revealed an eventual variation of parameters, like the high voltage, which may affect the light collecting system, and hence the TL dose results. This was investigated and although the high voltage requires a careful look, the stability and reproducibility of the TLD system was ascertained by the results of quality control procedures. As a consequence of this work, the start-up procedure was modified and the warning levels used for the start-up daily tests of the readers were derived from a more realistic approach.  相似文献   

6.
A new configuration for a thermoluminescent dosimetric card has been developed through collaboration between the Institute of Nuclear Physics in Kraków and several commercial dosimetric companies. The card is based on high-sensitivity LiF:Mg,Cu,P circular pellets (MCP-N) welded inside synthetic foils. The basic configuration consists of two pellets of 3.6 mm diameter and thicknesses from 0.25 up to 0.38 mm. The cards can be processed in a standard 6600 or 8800 Harshaw automatic TLD reader. The dosemeters demonstrate very high sensitivity, low background and good stability. This article presents results of the performance tests of the new dosimetric cards in the automatic TLD readers and a comparison of their properties.  相似文献   

7.
The uncertainty in very low doses measured with TLDs is partly caused by the uncertainty in the zero signal of the detector. A mathematical model for the thermodynamics of TLD heating and the zero signal in a hot gas reader with constant gas temperature is presented. The major component of the heating is described as diffusion limited conductive heating, the major component of the zero signal is black body radiation from the hot TLD. The parameters in the model were determined from the glow curves recorded at five different gas temperatures. The model explains the shape and statistics of a zero signal glow curve and can be used in the quality control of non-irradiated TLDs before calibration irradiation and readout.  相似文献   

8.
The results of an intercomparison exercise within the US Navy dosimetric network (USN-DN) are presented and discussed. The USN-DN uses a commercially available LiF:Mg,Cu,P thermoluminescent dosemeter (TLD) model Harshaw 8840/8841 and TLD reader model Harshaw 8800 manufactured by Thermo Fisher Scientific. The USN-DN consists of a single calibration facility and 16 satellite dosimetry reading facilities throughout the world with ~ 40 model 8800 TLD readers and in excess of 350 000 TLD cards in circulation. The Naval Dosimetry Center (NDC) is the primary calibration site responsible for the distribution and calibration of all TLD cards and their associated holders. In turn, each satellite facility is assigned a subpopulation of cards, which are utilised for servicing their local customers. Consistency of the NDC calibration of 150 dosemeters (calibrated at NDC) and 27 locally calibrated remote readers was evaluated in the framework of this intercomparison. Accuracy of TLDs' calibration, performed at the NDC, was found to be <3 % throughout the entire network. Accuracy of the readers' calibration, performed with the NDC issued calibration dosemeters at remote sites, was found to be better than 4 % for most readers. The worst performance was found for reader Channel 3, which is calibrated using the thinnest chip of the Harshaw 8840/8841 dosemeter. The loss of sensitivity of this chip may be caused by time-temperature profile that has been designed for all four chips without consideration of chip thickness.  相似文献   

9.
The ENEA photon dosemeter, introduced in 1995, consisting of two differently filtrated LiF(Mg,Cu,P) detectors, has been modified recently. The ABS (acrylonitrile butadiene styrene) plastic support has been replaced by a new aluminium card supporting the same two detectors (LiF(Mg,Cu,P) GR200). The new card, fully developed at the ENEA-Radiation Protection Institute (which is going to be patented), can now be processed through a Harshaw Model 6600 Automated TLD Reader, a hot gas reader. This paper reports the results of the individual calibration of approximately 60,000 LiF(Mg,Cu,P) GR200 detectors inserted on the new aluminium cards. Before the implementation in routine of the new cards, the reader has been characterised. Steps and tests to be made to use the card in routine (i.e. reader stability, linearity, reproducibility, etc.) are reported. The whole dosimetric system now combines the very good performances of the Harshaw Model 6600 reader and that of LiF(Mg,Cu,P) thermoluminescent material.  相似文献   

10.
One source of background signals, which are non-radiation related, is the reader system and it includes dark current, external contaminants and electronic spikes. These factors can induce signals equivalent to several hundredths of mSv. Mostly, the effects are minimised by proper design of the TLD reader, but some effects are dependent on proper operation of the system. The other main group of background signals originates in the TL crystal and is due to tribothermoluminescence, dirt, chemical reactions and stimulation by visible or UV light. These factors can have a significant contribution, equivalent to over several mSv, depending on whether the crystal is bare or protected by PTFE. Working in clean environments, monitoring continuously the glow curves and performing glow curve deconvolution are suggested to minimise non-radiation induced spurious signals.  相似文献   

11.
In modern radiation therapy such as intensity modulated radiation therapy or proton therapy, one is able to cover the target volume with improved dose conformation and to spare surrounding tissue with help of modern measurement techniques. Novel thermoluminescence dosimetry (TLD) foils, developed from the hot-pressed mixture of LiF:Mg,Cu,P (MCP TL) powder and ethylene-tetrafluoroethylene (ETFE) copolymer, have been applied for 2-D dosimetry of radiotherapeutical proton beams at INFN Catania and IFJ Krakow. A TLD reader with 70 mm heating plate and CCD camera was used to read the 2-D emission pattern of irradiated foils. The absorbed dose profiles were evaluated, taking into account correction factors specific for TLD such as dose and energy response. TLD foils were applied for measuring of dose distributions within an eye phantom and compared with predictions obtained from the MCNPX code and Eclipse Ocular Proton Planning (Varian Medical Systems) clinical radiotherapy planning system. We demonstrate the possibility of measuring 2-D dose distributions with point resolution of about 0.5 x 0.5 mm(2).  相似文献   

12.
A batch of LiF thermoluminescence dosemeters (TLDs), each containing five TLD-600 and TLD-700 thermoluminescence dosemeter chips, was irradiated with 59.85 MeV per nucleon 86Kr20+ ions from the K1200 superconducting cyclotron at the National Superconducting Cyclotron Laboratory (NSCL). Michigan State University, USA. The average linear energy transfer of the accelerated 86Kr ions and the resulting dose imparted to the TLD chips were calculated to be 3343 keV.microm(-1) per ion and 1.68 Gy respectively. A similar batch of TLD chips was irradiated with 1.3 MeV gamma rays from a 60Co source to 1.0 Gy. The TLD chips were evaluated at a ramp heating rate of 10 degrees C.s(-1) to 400 degrees C using a hot-finger type TLD reader. The thermoluminescence efficiency of the TLD-600 and TLD-700 dosemeters, relative to 60Co gamma rays was calculated to be 0.0025 and 0.0027 respectively  相似文献   

13.
We are introducing a new high-capacity thermoluminescent dosemeter (TLD) system to measure the whole body values of H(p)(10) and H(p)(0.07) from photons for use in individual monitoring services. Small and light-weight badges allow a convenient application in a wide variety of workplaces with photon radiation from 20 keV to at least 7 MeV. The main advantage of this system will be the large capacity of ~ 100,000 dosemeters per month at costs equivalent to the current film monitoring. The hot-pressed thin-layer TL detector (LiF:Mg,Ti) is welded onto an aluminium substrate and provided with a data matrix code for automatic processing. The detector holder has been optimised, that no additional filter is necessary. The new designed TLD reader with readout times <10 s will allow a large throughput and a considerable degree of automation.  相似文献   

14.
三轴承支撑不平衡转子非线性动力学研究   总被引:7,自引:1,他引:7  
针对具有三个滑动轴承支撑的双跨弹性转子的非线性特点,建立了数学模型,用数值积分和庞加莱映射方法对采用短同承模型的该类转子系统动力学特性随某一参数变化时稳定性的改变进行了分析,计算结果表明,系统具有发生倍周期分叉、概周期的可能,用数值方法得到系统在某些域中的分叉图,直观显示了系统在某些参数域中的运行状态和轴承几何参数变化对系统动力特性的影响,数值分析结果为该类转子--轴承系统的设计和运动状态控制提供了理论参考。  相似文献   

15.
This paper introduces a new type of tuned liquid damper (TLD) having a relatively simple, easy-to-model behavior and high effectiveness in controlling structural vibrations. It consists of a traditional TLD with addition of a floating roof. Since the roof is much stiffer than water, it prevents wave breaking, hence making the response linear even at large amplitudes. The roof also facilitates the incorporation of supplemental devices with which the level of damping of the liquid vibration can be substantially augmented. This newly proposed TLD, denoted as tuned liquid damper with floating roof (TLD-FR), maintains the traditional advantages of TLDs (low cost, easy installation and tuning), but its numerical characterization is much simpler because the floating roof suppresses higher sloshing vibration modes, resulting in a system that can be represented by a single-degree-of-freedom model. An efficient numerical scheme, where the dynamic behavior of the TLD-FR is expressed as a second-order lineal system of equations, is discussed and validated by scaled experimental tests. The equations of motion of a structure equipped with a TLD-FR are then derived and manipulated to offer a unifying representation dependent upon only four model characteristics of the TLD-FR: The first three (mass, frequency and damping ratios) are common for all type of mass dampers, whereas the final one, termed efficiency index, is related to a similar parameter used to characterize liquid column dampers. Through this approach, the behavior of the proposed TLD-FR can be easily correlated with the behavior of other well-known linear mass damper devices. The relationship between these parameters and the geometrical characteristics of the TLD-FR is also examined. Finally, the identification of the optimal characteristic of the TLD-FR (natural frequency and damping) under stationary stochastic excitation is discussed.  相似文献   

16.
为了保证机械式蒸汽再压缩(mechanical vapor recompression, MVR)系统的运行经济性和稳定性,对MVR系统中离心式蒸汽压缩机与蒸发器的匹配特性进行研究。针对蒸发器换热系数在新投、工作和结垢工况下的变化,提出了蒸发器运行温阻特性线的概念,并将其与离心式蒸汽压缩机的温升特性线叠加,从而开展离心式蒸汽压缩机与蒸发器的匹配分析。通过分析发现,离心式蒸汽压缩机的设计流量偏大或蒸发器的换热面积过小会导致匹配不足,易发生喘振,从而影响MVR系统的运行稳定性。而离心式蒸汽压缩机的设计流量偏小或蒸发器的换热面积过大会导致匹配过度,致使MVR系统的运行经济性差,甚至可能造成MVR系统无法建立热力自循环。结果表明,离心式蒸汽压缩机在MVR系统启动过程中会出现不稳定的喘振现象,可以通过系统参数的临时调节或采取辅助措施来避开不稳定区。设计时应保证离心式蒸汽压缩机的喘振裕度大于20%,蒸发器换热面积的设计裕度为30%;MVR系统运行时实际蒸发温度与设计温度的偏差应控制在±5 ℃以内。研究结果可为MVR系统的设计和调试提供参考。  相似文献   

17.
The experiment 'Dosimetric Mapping' conducted as part of the science program of NASA's Human Research Facility (HRF) between March and August 2001 was designed to measure integrated total absorbed doses (ionising radiation and neutrons), heavy ion fluxes and its energy, mass and linear energy transfer (LET) spectra, time-dependent count rates of charged particles and their corresponding dose rates at different locations inside the US Lab at the International Space Station. Owing to the variety of particles and energies, a dosimetry package consisting of thermoluminescence dosemeter (TLD) chips and nuclear track detectors with and without converters (NTDPs), a silicon dosimetry telescope (DOSTEL), four mobile silicon detector units (MDUs) and a TLD reader unit (PILLE) with 12 TLD bulbs as dosemeters was used. Dose rates of the ionising part of the radiation field measured with TLD bulbs applying the PILLE readout system at different locations varied between 153 and 231 microGy d(-1). The dose rate received by the active devices fits excellent to the TLD measurements and is significantly lower compared with measurements for the Shuttle (STS) to MIR missions. The comparison of the absorbed doses from passive and active devices showed an agreement within +/- 10%. The DOSTEL measurements in the HRF location yielded a mean dose equivalent rate of 535 microSv d(-1). DOSTEL measurements were also obtained during the Solar Particle Event on 15 April 2001.  相似文献   

18.
Accurate dosimetry is a prerequisite for reliable comparisons between radiobiological irradiation experiments. Parameters affecting the determination of absorbed dose to cells in the shape of a small cell pellet in a centrifuge tube, irradiated by 28 keV mono-energetic photons from a synchrotron, were investigated. Thermoluminescent dosimeter (TLD), diode and ion chambers were utilized to monitor the irradiations. The distribution of the absorbed dose and such parameters as scatter, attenuation and interface dosimetry in the target, which influence the dose, were studied. A method for inter-calibrations of two different calibration sources by using TLD and TLD readers is given. Characteristics of the TLD, that is, fading, supralinearity, energy response, self-attenuation and mini-dosimetry were considered for the dosimetry. A method for correcting photon fluence attenuation in cylindrical TLDs is presented. The study shows that the absorbed dose to cells irradiated at low photon energy at a synchrotron irradiation facility can, using accurate dosimetry protocol, be correctly and reproducibly determined.  相似文献   

19.
At the Institute of Nuclear Physics of the Polish Academy of Sciences (IFJ) in Kraków, a two-dimensional (2-D) thermoluminescence (TL) dosimetry system was developed within the MAESTRO (Methods and Advanced Equipment for Simulation and Treatment in Radio-Oncology) 6 Framework Programme and tested by evaluating 2-D dose distributions around radioactive sources. A thermoluminescent detector (TLD) foil was developed, of thickness 0.3 mm and diameter 60 mm, containing a mixture of highly sensitive LiF:Mg,Cu,P powder and Ethylene TetraFluoroEthylene (ETFE) polymer. Foil detectors were irradiated with (226)Ra brachytherapy sources and a (90)Sr/(90)Y source. 2-D dose distributions were evaluated using a prototype planar (diameter 60 mm) reader, equipped with a 12 bit Charge Coupled Devices (CCD) PCO AG camera, with a resolution of 640 x 480 pixels. The new detectors, showing a spatial resolution better than 0.5 mm and a measurable dose range typical for radiotherapy, can find many applications in clinical dosimetry. Another technology applicable to clinical dosimetry, also developed at IFJ, is the Si microstrip detector of size 95 x 95 mm(2), which may be used to evaluate the dose distribution with a spatial resolution of 120 microm along one direction, in real-time mode. The microstrip and TLD technology will be further improved, especially to develop detectors of larger area, and to make them applicable to some advanced radiotherapy modalities, such as intensity modulated radiotherapy (IMRT) or proton radiotherapy.  相似文献   

20.
张娅  王维民  姚剑飞 《振动与冲击》2012,31(12):141-145
动静碰摩是透平机械常见的故障之一,其动力学行为较为复杂,表现为在机器运行的过程中碰摩故障产生的故障征兆丰富多样。建立了双盘转子-轴承系统在轴向碰摩、径向碰摩以及两种碰摩共同冲击下的有限元法连续模型,采用计及了回转效应和剪切效应的梁单元,对转子系统在不同碰摩情况下的非线性动力学行为进行了数值模拟,研究了转子转速、转子系统上的不平衡量的分布以及碰摩刚度对系统的影响。研究结果表明:相对于径向碰摩故障的动力学特征,轴向碰摩产生的非线性特征不明显,与工程中观察的现象基本一致的;但当两种碰摩均考虑时,系统的非线性动力学特征与仅考虑径向碰摩时有显著的不同。所得计算结果可为大型高速旋转机械系统的故障诊断和碰摩故障的振动控制提供理论指导,从而保证系统的安全运行。  相似文献   