1.
This paper experimentally investigates the sintered porous heat sink for the cooling of the high-powered compact microprocessors for server applications. Heat sink cold plate consisted of rectangular channel with sintered porous copper insert of 40% porosity and 1.44 × 10?11 m2 permeability. Forced convection heat transfer and pressure drop through the porous structure were studied at Re ? 408 with water as the coolant medium. In the study, heat fluxes of up to 2.9 MW/m2 were successfully removed at the source with the coolant pressure drop of 34 kPa across the porous sample while maintaining the heater junction temperature below the permissible limit of 100 ± 5 °C for chipsets. The minimum value of 0.48 °C/W for cold plate thermal resistance (Rcp) was achieved at maximum flow rate of 4.2 cm3/s in the experiment. For the designed heat sink, different components of the cold plate thermal resistance (Rcp) from the thermal footprint of source to the coolant were identified and it was found that contact resistance at the interface of source and cold plate makes up 44% of Rcp and proved to be the main component. Convection resistance from heated channel wall with porous insert to coolant accounts for 37% of the Rcp. With forced convection of water at Re = 408 through porous copper media, maximum values of 20 kW/m2 K for heat transfer coefficient and 126 for Nusselt number were recorded. The measured effective thermal conductivity of the water saturated porous copper was as high as 32 W/m K that supported the superior heat augmentation characteristics of the copper–water based sintered porous heat sink. The present investigation helps to classify the sintered porous heat sink as a potential thermal management device for high-end microprocessors.  相似文献   

2.
A novel miniature porous heat sink system was presented for dissipating high heat fluxes of electronic device, and its operational principle and characteristics were analyzed. The flow and heat transfer of miniature porous heat sink was experimentally investigated at high heat fluxes. It was observed that the heat load of up to 280 W (heat flux of 140 W/cm2) was removed by the heat sink with the coolant pressure drop of about 34 kPa across the heat sink system and the heater junction temperature of 62.9 °C at the coolant flow rate of 6.2 cm3/s. Nu number of heat sink increased with the increase of Re number, and maximum value of 323 for Nu was achieved at highest Re of 518. The overall heat transfer coefficient of heat sink increased with the increase of coolant flow rate and heat load, and the maximal heat transfer coefficient was 36.8 kW(m2 °C)?1 in the experiment. The minimum value of 0.16 °C/W for the whole thermal resistance of heat sink was achieved at flow rate of 6.2 cm3/s, and increasing coolant flow rate and heat fluxes could lead to the decrease in thermal resistance. The micro heat sink has good performance for electronics cooling at high heat fluxes, and it can improve the reliability and lifetime of electronic device.  相似文献   

3.
The paper presents the geometric optimization of the micro-heat sink with straight circular microchannels with inner diameter of Di = 900 μm. The inlet cross-section has a rectangular shape and positioned tangentially to the tube axis with the four different geometries. The fluid flow regime is laminar and water with variable fluid properties is used as a working fluid. The heat flux spread through the bottom sink surface is q = 100 W/cm2. Thermal and hydrodynamic performances of the heat sink are compared with results obtained for conventional channel configuration with lateral inlet/outlet cross-section. Besides, the results are compared with the tangential micro-heat sink with Di = 300 μm. For all the cases, the thermal and hydrodynamic results are compared on a fixed pumping power basis.  相似文献   

4.
Previous studies have investigated the thermal performance of embedding a single piezoelectric fan in a heat sink. Based on this work, a multiple piezoelectric–magnetic fan system (“MPMF”) has been successfully developed that exhibits lower fan power consumption, optimum fan pitch and an optimum fan gap between the fan tips and the heat sink. In this study, the cooling performance and heat convection improvement for the MPMF system embedded in a heat sink are evaluated at different fan tip locations. The results indicate that the fan tip location of the MPMF system at x/Sl = 0.5 and y/Sh = 0 is an optimum configuration, improving the thermal resistance by 53.2% over natural convection condition for the fan input power of 0.1 W. The MPMF system breaks the thermal boundary layer and causes fluctuations inside the fins of the heat sink to enhance the overall heat transfer coefficient. Moreover, the relationship between the convection improvement and the Reynolds number for the MPMF system has been investigated and transformed into a correlation line for nine different fan tip locations to provide a means of predicting the cooling performance for the MPMF system embedded in a heat sink.  相似文献   

5.
This work uses an optimization procedure consisting of a simplified conjugate-gradient method and a three-dimensional fluid flow and heat transfer model to investigate the optimal geometric parameters of a double-layered microchannel heat sink (DL-MCHS). The overall thermal resistance RT is the objective function to be minimized, and the number of channels N, channel width ratio β, lower channel aspect ratio αl, and upper channel aspect ratio αu are the search variables. For a given bottom area (10 × 10 mm) and heat flux (100 W/cm2), the optimal (minimum) thermal resistance of the double-layered microchannel heat sink is about RT = 0.12 °C/m2W. The corresponding optimal geometric parameters are N = 73, β = 0.50, αl = 3.52, and, αu = 7.21 under a total pumping power of 0.1 W. These parameters reduce the overall thermal resistance by 52.8% compared to that yielded by an initial guess (N = 112, β = 0.37, αl = 10.32, and αu = 10.93). Furthermore, the optimal thermal resistance decreases rapidly with the pumping power and then tends to approach an constant value. As the pumping power increases, the optimal values of N, αl, and αu increase, whereas the optimal β value decreases. However, increasing the pumping power further is not always cost-effective for practical heat sink designs.  相似文献   

6.
New experimental critical heat flux results for saturated boiling conditions have been obtained for R236fa flowing in a silicon multi-microchannel heat sink composed of 67 parallel channels, 223 μm wide, 680 μm high and with 80 μm thick fins separating the channels. The microchannel length was 20 mm. The footprint critical heat fluxes measured varied from 112 to 250 W/cm2 and the wall critical heat fluxes from 21.9 to 52.2 W/cm2 for mass velocities from 276 to 992 kg/m2s. When increasing the mass velocity, the wall critical heat flux was observed to increase. The inlet saturation temperatures (20.31 ? Tsat,in ? 34.27 °C) and the inlet subcoolings (0.4 ? Δ Tsub ? 15.3 K) were found to have a negligible influence on the saturated CHF. The best methods for predicting the data were those of Wojtan et al. [L. Wojtan, R. Revellin, J. R. Thome, Investigation of critical heat flux in single, uniformly heated microchannels, Exp. Therm. Fluid Sci. 30 (2006) 765–774] and Revellin and Thome [R. Revellin, J. R. Thome, A theoretical model for the prediction of the critical heat flux in heated microchannels, Int. J. Heat Mass Transfer 50 (in press)]. They both predict the experimental CHF results with a mean absolute error of around 9%. Using the critical vapour quality, an annular-to-dryout transition is also proposed as a limit in a diabatic microscale flow pattern map. Pressure drop measurements were measured and analysed, showing that the homogeneous model could correctly predict the observed trends.  相似文献   

7.
This paper reports the results of an experimental investigation of the performance of finned heat sinks filled with phase change materials for thermal management of portable electronic devices. The phase change material (PCM) used in this study is n-eicosane and is placed inside a heat sink made of aluminium. Aluminium acts as thermal conductivity enhancer (TCE), as the thermal conductivity of the PCM is very low. The heat sink acts as an energy storage and a heat-spreading module. Studies are conducted for heat sinks on which a uniform heat load is applied for the unfinned and finned cases. The test section considered in all cases in the present work is a 80 × 62 mm2 base with TCE height of 25 mm. A 60 × 42 mm2 plate heater with 2 mm thickness is used to mimic the heat generation in electronic chips. Heat sinks with pin fin and plate fin geometries having the same volume fraction of the TCE are used. The effect of different types of fins for different power level (ranging from 2 to 7 W) in enhancing the operating time for different set point temperatures and on the duration of latent heating phase were explored in this study. The results indicate that the operational performance of portable electronic device can be significantly improved by the use of fins in heat sinks filled with PCM.  相似文献   

8.
This paper numerically and experimentally investigated the liquid cooling efficiency of heat sinks containing micro pin fins. Aluminum prototypes of heat sink with micro pin fin were fabricated to explore the flow and thermal performance. The main geometry parameters included the diameter of micro pin fin and porosity of fin array. The effects of the geometrical parameters and pressure drop on the heat transfer performance of the heat sink were studied. In the experiments, the heat flux from base of heat sink was set as 300 kW/m2. The pressure drop between the inlet and the outlet of heat sink was set < 3000 Pa. Numerical simulations with similar flow and thermal conditions were conducted to estimate the flow patterns, the effective thermal resistance. It was found that the effective thermal resistance would reach an optimum value for various pressure drops. It was also noted that the effective thermal resistance was not sensitive to porosity for sparsely packed pin fins.  相似文献   

9.
We proposed an extended vapor chamber (EVC), consisting of an evaporator part and an extended condenser part. A layer of compressed copper foam was sintered on the inner evaporator surface. The extended condenser includes a circular-straight groove network and a fin region. The groove network distributes generated vapor everywhere in the internal volume of EVC. A set of capillary holes are machined within fins. A sliced copper foam bar is inserted in each of capillary hole. The peaks of copper foam bar are tightly contacted with the evaporator copper foam piece. Water is used as the working fluid with a heater area of 0.785 cm2. A minimum thermal resistance of 0.03 K/W is reached for the bottom heating. The heat flux is up to 450 W/cm2 without reaching dryout. The transition point of thermal resistances versus heat fluxes is significantly delayed with the heat flux exceeding 300 W/cm2, beyond which thermal resistances are only slightly increased. EVC not only improves temperature uniformity on the evaporator and fin base surfaces, but also evens the temperature distribution along the fin height direction to increase the fin efficiency. Inclination angles and charge ratios are combined to affect the thermal performance of EVC. An optimal charge ratio of 0.3 was recommended. EVC can be used for ultra-high heat flux and larger heater area conditions.  相似文献   

10.
This work describes an inverse problem method to optimize the geometric design for microchannel heat sinks using a novel multi-parameter optimization approach, which integrates the simplified conjugate-gradient scheme and a fully developing three-dimensional heat transfer and flow model. Overall thermal resistance is the objective function to be minimized with number of channels, N, channel aspect ratio, α, and the ratio of channel width to pitch, β, as search variables. With a constant bottom area (10 mm × 10 mm), constant heat flux applied to the heat sink bottom surface (100 W cm?2), and constant pumping power (0.05 W), the optimal design values are N = 71, α = 8.24, and β = 0.6, with a minimum overall thermal resistance of 0.144 K W?1. Increasing pumping power reduces overall thermal resistance of the optimal design; however, the design’s effectiveness declines significantly under high pumping power. The N and α values in the optimal design increase and β decreases as pumping power increases.  相似文献   

11.
This article is the first in a three part study on flow boiling of refrigerants R236fa and R245fa in a silicon multi-microchannel heat sink. The heat sink was composed of 67 parallel channels, which are 223 μm wide, 680 μm high and 20 mm long with 80 μm thick fins separating the channels. The base heat flux was varied from 3.6 to 221 W/cm2, the mass velocity from 281 to 1501 kg/m2 s and the exit vapour quality from 2% to 75%. The working pressure and saturation temperature were set nominally at 273 kPa and 25 °C, respectively. The present database includes 1217 local heat transfer coefficient measurements, for which three different heat transfer trends were identified, but in most cases the heat transfer coefficient increased with heat flux and was almost independent of vapour quality and mass velocity. Importantly, it was found for apparently the first time that the heat transfer coefficient as a function of vapour quality reaches a maximum at very high heat fluxes and then decreases with further increase of heat flux.  相似文献   

12.
Two special biporous wicks are adopted in stainless-steel–ammonia loop heat pipes (LHPs) with flat evaporator to enhance their heat transfer performances. The experimental results demonstrate that thermal and hydraulic characteristics of the wick with porosity of 69% (in LHP 2) are better than that of the wick with porosity of 65% (in LHP 1). The maximum heat loads of LHP 1 and LHP 2 could, respectively, reach 120 W (heat flux 11.8 W/cm2) and 130 W (12.8 W/cm2) at the allowable evaporator temperature below 60 °C. Meanwhile, they can start up at heat load as low as 2.5 W. The LHPs show very fast and smooth response to heat load and operate stably without obvious temperature oscillation. The total thermal resistances of the LHPs vary between 1.47 and 0.33 °C/W at heat load ranging from 10 to 130 W.  相似文献   

13.
With the rapid development of the information technology (IT) industry, the heat flux in integrated circuit (IC) chips cooled by air has almost reached its limit about 100 W/cm2. Some applications in high technologies require heat fluxes well beyond such a limitation. Therefore the search of a more efficient cooling technology becomes one of the bottleneck problems of the further development of IT industry. The microchannel flow geometry offers large surface area of heat transfer and a high convective heat transfer coefficient. However, it has been hard to implement because of its very high pressure head required to pump the coolant fluid though the channels. A normal channel could not give high heat flux although the pressure drop is very small. A minichannel can be used in heat sink with a quite high heat flux and a mild pressure loss. A minichannel heat sink with bottom size of 20 mm × 20 mm is analyzed numerically for the single-phase laminar flow of water as coolant through small hydraulic diameters and a constant heat flux boundary condition is assumed. The effects of channel dimensions, channel wall thickness, bottom thickness and inlet velocity on the pressure drop, thermal resistance and the maximum allowable heat flux are presented. The results indicate that a narrow and deep channel with thin bottom thickness and relatively thin channel wall thickness results in improved heat transfer performance with a relatively high but acceptable pressure drop. A nearly-optimized configuration of heat sink is found which can cool a chip with heat flux of 256 W/cm2 at the pumping power of 0.205 W. The nearly-optimized configuration is verified by an orthogonal design. The simulated thermal resistance agrees quite well with the result of conventional correlations method with the maximum difference of 12%.  相似文献   

14.
In this study, effects of cross-cuts on the thermal performance of heat sinks under the parallel flow condition are experimentally studied. To find effects of the length, position, and number of cross-cuts, heat sinks with one or several cross-cuts ranging from 0.5 mm to 10 mm were fabricated. The pressure drop and the thermal resistance of the heat sinks are obtained in the range of 0.01 W<Pp < 1 W. Experimental results show that among the many cross-cut design parameters, the cross-cut length has the most significant influence on the thermal performance of heat sinks. The results also show that heat sinks with a cross-cut are superior to heat sinks containing several cross-cuts in the thermal performance. Based on experimental results, the friction factor and Nusselt number correlations for heat sinks with a cross-cut are suggested. Using the proposed correlations, thermal performances of cross-cut heat sinks are compared to those of optimized plate-fin and square pin-fin heat sinks under the constant pumping power condition. This comparison yields a contour map that suggests an optimum type of heat sink under the constraint of the fixed pumping power and fixed heat sink volume. The contour map shows that an optimized cross-cut heat sink outperforms optimized plate-fin and square pin-fin heat sinks when 0.04 < log L1 < 1.  相似文献   

15.
A spray cooling study was conducted to investigate the effect of enhanced surfaces on Critical Heat Flux (CHF). Test surfaces involved micro-scale indentations and protrusions, macro (mm) scale pyramidal pin fins, and multi-scale structured surfaces, combining macro and micro-scale structures, along with a smooth surface that served as reference. Tests were conducted in a closed loop system using a vapor atomized spray nozzle with ammonia as the working fluid. Nominal flow rates were 1.6 ml/cm2 s of liquid and 13.8 ml/cm2 s of vapor, resulting in a pressure drop of 48 kPa. Results indicated that the multi-scale structured surface helped increase maximum heat flux limit by 18% over the reference smooth surface, to 910 W/cm2 at nominal flow rate. During the additional CHF testing at higher flow rates, most heaters experienced failures before reaching CHF at heat fluxes above 950 W/cm2. However, some enhanced surfaces can achieve CHF values of up to ≈1100 W/cm2 with ≈67% spray cooling efficiency based on liquid usage. The results also shed some light on the current understanding of the spray cooling heat transfer mechanisms. Enhanced surfaces are found to be capable of retaining more liquid compared to a smooth surface, and efficiently spread the liquid film via capillary force within the structures. This important advantage delays the occurrence of dry patches at high heat fluxes, and leads to higher CHF. The present work demonstrated ammonia spray cooling as a unique alternative for challenging thermal management tasks that call for high heat flux removal while maintaining a low device temperature with a compact and efficient cooling scheme.  相似文献   

16.
An experimental study has been performed on single-phase heat transfer, boiling inception, and pressure drop of R-123 over a bank of shrouded micro pin fins 243 μm long with hydraulic diameter of 99.5 μm. Heat transfer coefficients and Nusselt numbers have been obtained over effective heat fluxes ranging from 3.5 to 65.5 W/cm2 and Reynolds numbers from 134 to 314. A delay in boiling incipience has been observed and a meta-stable single-phase region was apparent at liquid exit temperatures noticeably exceeding the saturation temperature. Once boiling was initiated, vapor burst instabilities resembling the compound relaxation instabilities were attained. It has also been found that endwalls effects on heat transfer diminished for Re > 100.  相似文献   

17.
Flow boiling heat transfer experiments using R134a were carried out for jet impingement on smooth and enhanced surfaces. The enhanced surfaces were circular micro pin fins, hydrofoil micro pin fins, and square micro pin fins. The effects of saturation pressure, heat flux, Reynolds number, pin fin geometry, pin fin array configuration, and surface aging on flow boiling heat transfer characteristics were investigated. Flow boiling experiments were carried out for two different saturation pressures, 820 kPa and 1090 kPa. Four jet exit velocities ranging from 1.1–4.05 m/s were investigated. Flow boiling jet impingement on smooth surfaces was characterized by large temperature overshoots, exhibiting boiling hysteresis. Flow boiling jet impingement on micro pin fins displayed large heat transfer coefficients. Heat transfer coefficients as high as 150,000 W/m2 K were observed at a relatively low velocity of 2.2 m/s with the large (D = 125 μm) circular micro pin fins. Jet velocity, surface aging, and saturation pressure were found to have significant effects on the two-phase heat transfer characteristics. Subcooled nucleate boiling was found to be the dominant heat transfer mechanism.  相似文献   

18.
This article investigates the thermoelectric air-cooling module for electronic devices. The effects of heat load of heater and input current to thermoelectric cooler are experimentally determined. A theoretical model of thermal analogy network is developed to predict the thermal performance of the thermoelectric air-cooling module. The result shows that the prediction by the model agrees with the experimental data. At a specific heat load, the thermoelectric air-cooling module reaches the best cooling performance at an optimum input current. In this study, the optimum input currents are from 6 A to 7 A at the heat loads from 20 W to 100 W. The result also demonstrates that the thermoelectric air-cooling module performs better performance at a lower heat load. The lowest total temperature difference-heat load ratio is experimentally estimated as ?0.54 W K?1 at the low heat load of 20 W, while it is 0.664 W K?1 at the high heat load of 100 W. In some conditions, the thermoelectric air-cooling module performs worse than the air-cooling heat sink only. This article shows the effective operating range in which the cooling performance of the thermoelectric air-cooling module excels that of the air-cooling heat sink only.  相似文献   

19.
This study numerically investigates the impinging cooling of porous metallic foam heat sink. The analyzed parameters ranges comprise ε = 0.93/10 PPI Aluminum foam, L/W = 20, Pr = 0.7, H/W = 2–8, and Re = 100–40,000. The simulation results exhibit that when the Re is low (such as Re = 100), the Numax occurs at the stagnation point (i.e. X = 0). However, when the Reynolds number increases, the Numax would move downwards, i.e. the narrowest part between the recirculation zone and the heating surface. Besides, the extent to which the inlet thermal boundary condition influences the prediction accuracy of the Nusselt number increases with a decreasing H/W and forced convective effect. The application ranges of H/W and Re that the effect of the inlet thermal boundary condition can be neglected are proposed. Lastly, comparing our results with those in other studies reveals that the heat transfer performance of the Aluminum foam heat sink is 2–3 times as large as that without it. The thermal resistance is also 30% less than that of the plate fin heat sink for the same volumetric flow rate and the 5.3 mm jet nozzle width. Therefore, the porous Aluminum foam heat sink enhances the heat transfer performance of impinging cooling.  相似文献   

20.
This study investigates the influence of using micro-encapsulated phase change material (MEPCM) on the thermal and hydraulic performance of micro-channel heat sinks used for heat dissipation of high power electronic devices. A three-dimensional, one-phase, laminar flow model of a rectangular channel using water slurry of MEPCM with temperature dependent physical properties was developed. The results showed a significant increase in the heat transfer coefficient under certain conditions for heat flux rates of 100 W/cm2 and 500 W/cm2 that is mainly dependant on the channel inlet and outlet temperatures and the selected MEPCM melting temperature. Lower and more uniform temperatures across the electronic device can be achieved at less pumping power compared to using water only as the cooling fluid.  相似文献   