Grey water from a university facilities building in Cairo, Egypt was analysed for basic wastewater parameters. Mean concentrations were calculated based on grab samples over a 16-month period. Values for chemical oxygen demand (COD) and nutrients exceeded values reported in a number of other studies of grey water, while coliform counts were also high. A submerged membrane bioreactor (SMBR) system using a hollow fibre ultrafiltration membrane was used to treat the grey water with the aim of producing effluent that meets reuse guidelines for agriculture. A test run for 50 days at constant transmembrane pressure resulted in very good removal for key parameters including COD, total suspended solids (TSS), colour, turbidity, ammonia nitrogen, anionic surfactants, and coliform bacteria. High standard deviations were observed for COD and coliform concentrations for both monthly grab samples and influent values from the 50-day SMBR experiment. SMBR effluent meets international and local guidelines for at least restricted irrigation, particularly as pertains to COD, TSS, and faecal coliforms which were reduced to mean treated values of 50 mg/L, 0 mg/L (i.e., not detected), and <50 cfu/100 mL, respectively.  相似文献   

2.
Anaerobic digestion of concentrated domestic wastewater streams--black or brown water, and solid fraction of kitchen waste is considered as a core technology in a source separation based sanitation concept (DESAR--decentralised sanitation and reuse). A simple anaerobic digester can be implemented for an enhanced primary treatment or, in some situations, as a main treatment. Two reactor configurations were extensively studied; accumulation system (AC) and UASB septic tank at 15, 20 and 25 degrees C. Due to long retention times in an AC reactor, far stabilisation of treated medium can be accomplished with methanisation up to 60%. The AC systems are the most suitable to apply when the volume of waste to be treated is minimal and when a direct reuse of a treated medium in agriculture is possible. Digested effluent contains both liquid and solids. In a UASB septic tank, efficient separation of solids and liquid is accomplished. The total COD removal was above 80% at 25 degrees C. The effluent contains COD and nutrients, mainly in a soluble form. The frequency of excess sludge removal is low and sludge is well stabilised due to a long accumulation time.  相似文献   

3.
The potential of membrane bioreactors to enhance the removal of selected metals from low loaded sewages has been explored. A 1400 litre pilot plant, equipped with an industrial submerged module of hollow fibre membranes, has been used in three different configurations: membrane bioreactor, operating in sequencing batch modality, for the treatment of real mixed municipal/industrial wastewater; membrane-assisted biosorption reactor, for the treatment of real leachate from municipal landfills; continuously fed membrane bioreactor, for the treatment of water charged with cadmium and nickel ions. The results show that: (a) in treating wastewaters with low levels of heavy metals (< one milligram per litre concentration), operating high sludge ages is not an effective strategy to significantly enhance the metals removal; (b) Hg and Cd are effectively removed already in conventional systems with gravitational final clarifiers, while Cu, Cr, Ni can rely on a additional performance in membrane bioreactors; (c) the further membrane effect is remarkable for Cu and Cr, while it is less significant for Ni. Basically, similar membrane effects recur in three different experimental applications that let us estimate the potential of membrane system to retain selected metal complexes. The future development of the research will investigate the relations between the membrane effect and the manipulable filtration parameters (i.e., permeate flux, solids content, filtration cycle).  相似文献   

4.
Performances of a granular sequencing batch reactor (GSBR).   总被引:2,自引:0,他引:2  
Aerobic granulation in sequencing batch reactors is widely reported in literature and in particular in SBAR (Sequencing batch airlift reactor) configuration, due to the high localised hydrodynamic shear forces that occur in this type of configuration. The aim of this work was to observe the phenomenon of the aerobic granulation and to confirm the excellent removal efficiencies that can be achieved with this technology. In order to do that, a laboratory-scale plant, inoculated with activated sludge collected from a conventional WWTP, was operated for 64 days: 42 days as a SBAR and 22 days as a SBBC (sequencing batch bubble column). The performances of the pilot plant showed excellent organics removal. COD and BOD removal efficiencies were respectively, 93 and 94%; on the contrary, N-removal efficiency was extremely low (5%-45%/o). The granules dimensions increased during the whole experimentation; change of reactor configuration contributed to further improve this aspect. The experimental work confirmed the essential role of hydraulic settling time in the formation of aerobic granules and in the sludge settleability and the need to find an optimum between granule size and oxygen supply to achieve good N-removal efficiency.  相似文献   

5.
A pilot-scale fluidised pellet bed (FPB) bioreactor, which combines chemical coagulation, biological degradation, particle pelletisation and separation in one unit, was applied for onsite wastewater treatment and reuse. As a result of rational use of inorganic coagulant and organic polymer and moderate mechanical agitation, spherical particles were generated in the upflow column and a well-fluidised bed was formed. With a continuous supply of dissolved oxygen through a recycling loop, an aerobic condition was kept in the bottom section of the FPB column. Under such conditions the pellets in the FPB column showed the following characteristics: (1) compact structure and high density; (2) rich in microorganisms; and (3) high MLSS and MLVSS concentrations. Therefore, the FPB bioreactor achieved more than 90% removal of SS, COD, BOD and TP from raw domestic wastewater within a total hydraulic retention time (HRT) of only about 30 minutes. It also showed nitrification and denitrification ability and the TN removal could be about 50% as the recycling ratio was increased to 1:1. The treated water quality is generally competitive with the secondary effluent from a conventional activated sludge process. With these advantages the FPB bioreactor is recommendable as a compact system for onsite wastewater treatment and reuse.  相似文献   

6.
Two-stage membrane bioreactor (MBR) system was applied to the treatment of landfill leachate from a solid waste disposal site in Thailand. The first stage anoxic reactor was equipped with an inclined tube module for sludge separation. It was followed by an aerobic stage with a hollow fiber membrane module for solid liquid separation. Mixed liquor sludge from the aerobic reactor was re-circulated back to anoxic reactor in order to maintain constant mixed liquor suspended solids (MLSS) concentration in the aerobic reactor. The removal of micro-pollutants from landfill leachate along the treatment period of 300 days was monitored. The results indicated that two-stage MBRs could remove biochemical oxygen demand (BOD), chemical oxygen demand (COD) and NH(4)(+) by 97, 87 and 91% at steady operating condition. Meanwhile organic micro-pollutant removals were 50-76%. The removal efficiencies varied according to the hydrophobic characteristic of compounds but they were improved during long-term MBR operation without sludge discharge.  相似文献   

7.
The purpose of this paper is to report the study of the fate and distribution of three endocrine disrupting compounds (estrogens); Estrone (E1), 17β-estradiol (E2), and 17α-ethinylestradiol (EE2) in a laboratory scale submerged membrane bioreactor (SMBR). For this matter, both aqueous and solids phases were analyzed for the presence of E1, E2 and EE2. The outcome of this study was that three SMBRs showed enhanced elimination of estrogens in different operational conditions; the estrogen removal was close to 100% in SMBR. Additionally, E1, E2 and EE2 were detected in SMBR sludge at concentrations of up to 41.2, 37.3 and 36.9 ng g(-1) dry weight, respectively. The estrogen removal in the SMBRs was directly influenced by a combination of simultaneous biodegradation-adsorption processes, indicating that the main removal mechanism of the estrogens in the SMBRs is the biodegradation process. The E1, E2 and EE2 were biologically degraded in the SMBR (87-100%). The sorption of estrogens onto activated sludge was from 2%. Therefore, a high potential for estrogen removal by biodegradation in the SMBR was observed, allowing less estrogen concentration in the dissolved phase available for the adsorption of these compounds onto biological flocs. Two different methods were carried out for mass balance calculations of estrogens in SMBR. For the first method, the measured data was used in both liquid and solid phases, whereas for the second one, it was in aqueous phase and solid-water distribution coefficients (K(d)) value of E1, E2 and EE2. The purpose of these methodologies is to make easier the identification of the main mechanisms involved in the removal of E1, E2 and EE2 in a SMBR. Both methods can be applied in order to determine the mechanism, fate and distribution of estrogens in a SMBR.  相似文献   

8.
林可霉素高浓度有机废水处理技术   总被引:1,自引:0,他引:1  
王冰 《水资源保护》2008,24(4):53-57
采用厌氧颗粒和好氧活性污泥分别对内循环厌氧反应器(IC)和间歇式活性污泥法(SBR)进行污泥接种培养,研究水解酸化-IC-SBR工艺在林可霉素生产废水处理方面的运行效果。结果表明:在进水COD的质量浓度为6 000~9 000 mg/L,IC和SBR反应器中有机负荷分别为0.82 kg/(kg.d)和0.26 kg/(kg.d)左右的情况下,IC和SBR反应器分别运行60 d和7 d,COD平均去除率分别达到91%和61%,出水COD的质量浓度在300 mg/L以下,达到GB 8978—1996《污水综合排放标准》二级标准。  相似文献   

9.
A brief review of the fate of micropollutants in membrane-based wastewater treatment due to sorption, stripping, biological degradation/transformation and membrane separation is discussed, to give an overview of these technologies due to the growing importance for water reuse purposes. Compared with conventional activated sludge treatment (CAS) micropollutant removal in membrane bioreactor (MBR) is slightly improved due to complete suspended solids removal and increased sludge age. For discharge to sensitive receiving waters advanced treatment, such as post-ozonation or activated carbon adsorption, is recommended. In water reuse plants nanofiltration (NF) and reverse osmosis (RO) efficiently reject micropollutants due to size exclusions as well as electrostatic and hydrophobic effects reaching potable quality. To remove micropollutants fully, additionally post-ozone or the addition of powdered activated carbon (PAC) have to be applied, which in parallel also reduce NDMA precursors. The concentrate has to be treated if disposed to sensitive receiving waters due to its high micropollutant concentration and ecotoxicity potential. The present review summarizes principles and capabilities for the most important membrane-based applications for wastewater treatment, i.e. porous membranes in MBRs (micro- or ultrafiltration) and dense membrane applications (NF and RO) for water reuse.  相似文献   

10.
In treating textile wastewater, the application of membrane bioreactor (MBR) technology showed high efficiency in COD and BOD5 removal. However, insufficient colour removal was achieved for possible reuse. The aim of the work presented in this paper was to test the performance of chemical advanced oxidation on the elimination of the colour downstream of an MBR. To improve the quality of the membrane bioreactor effluent three different oxidation treatments were tested at lab-scale: ozonation, chlorination and hydrogen peroxide oxidation. Colour, COD and BOD5 were controlled in order to assess the effectiveness of each process. For chlorination, even with 250 mg/L (active chlorine) only 80% colour removal (SACin = 14; SACout = 2.8) was achieved which is considered unsatisfactory. For hydrogen peroxide, the colour removal was even poorer; it was just 10% at a concentration of 250 mg/L. In contrast, good results were obtained by ozonation. By using only 38 mg/L within 20 minutes, it was possible to achieve the reuse recommendation with a satisfactory colour removal of 93% (SACin = 14; SACout = 0.98). The results showed that ozonation was the most promising method.  相似文献   

11.
In this study, a lab scale EGSB reactor was operated for 400 days to investigate the influence of temperature-decrease on the microbial characteristic of retained sludge. The EGSB reactor was started-up at 15 degrees C seeding with 20 degrees C-grown granular sludge. The influent COD of synthetic wastewater was set at 0.6-0.8 gCOD/L. The process-temperature was stepwise reduced from 15 degrees C to 5 degrees C during 400 days operation. Decrease of temperature of the reactor from 15 degrees C to 10 degrees C caused the decline of COD removal efficiency. However, continuous operation of the EGSB reactor led the efficient treatment of wastewater (70% of COD removal, 50% of methane recovery) at 10 degrees C. We confirmed that the both acetate-fed and hydrogen-fed methanogenic activities of retained sludge clearly increased under 15 to 20 degrees C. Changes of microbial profiles of methanogenic bacteria were analyzed by 16S rDNA-targeted DGGE analysis and cloning. It shows that genus Methanospirillum as hydrogen-utilizing methanogen proliferated due to low temperature operation of the reactor. On the other hand, genus Methanosaeta presented in abundance as acetoclastic-methanogen throughout the experiment.  相似文献   

12.
In recent years a completely autotrophic nitrogen removal process based on Anammox biomass has been tested in a few European countries in order to treat anaerobic supernatant and to increase the COD/N ratio in municipal wastewater. This work reports experimental results on a possible technical solution to upgrade the S. Colombano treatment plant which treats wastewater from the Florentine urban area. The idea is to use 50% of the volume of the anaerobic digester in order to treat external sewage sludge (as septic tank sludge) together with waste activated sludge and to treat the resulting effluent on a SHARON-ANAMMOX process in order to remove nitrogen from the anaerobic supernatant. Anaerobic co-digestion, tested in a 200 L pilot plant, enables low cost treatment of septic tank sludge and increases biogas production; however, it also increases the nitrogen load re-circulated to the WWTP, where nitrogen removal efficiency is already low (<50%), due to the low COD/N ratio, which limits predenitrification efficiency. Experimental results from a SHARON process tested in a lab-scale pilot plant show that nitrite oxidising bacteria are washed-out and steady nitrite production can be achieved at retention times in the range 1 - 1.5 days, at 35 degrees C. In a lab-scale SBR reactor, coupled with a nitration bioreactor, maximum specific nitrogen removal rate under nitrite-limiting conditions (with doubling time equal to about 26 days at 35 degrees C) was equal to 0.22 kgN/kgSSV/d, about 44 times the rate measured in inoculum Anammox sludge. Finally, a cost analysis of the proposed upgrade is reported.  相似文献   

13.
A high strength industrial wastewater was treated using a pilot scale submerged membrane bioreactor (MBR) at a sludge retention time (SRT) of 200 d. The MBR was operated at a high sludge concentration of 20 g/L and a low F/M ratio of 0.11 during 300 d of operation. It was found that the MBR could achieve COD and TOC overall removal efficiencies at more than 99 and 98% TN removal. The turbidity of the permeate was consistently in the range of 0.123 to 0.136 NTU and colour254 absorbance readings varied from 0.0912 to 0.0962 a.u. cm(-1). The sludge concentration was inversely proportional to the hydraulic retention time (HRT), yielded excellent organic removal and extremely low sludge production (0.0016 kgVSS/day).  相似文献   

14.
A 2.0 L volume of EGSB reactor was operated at 20 degrees C for more than 500 days with 0.3-0.4 g COD/L of sucrose base wastewater to investigate the influence of effluent-recirculation on the process performance. At the start up period, the reactor was operated in EGSB mode with 5 m/h upflow velocity by continuous effluent recirculation. The COD loading was set to 7.2-9.6 kg COD/m(3) day with HRT of 1 hour. However, in this mode, EGSB reactor exhibited insufficient COD removal efficiency, i.e., 50-60%. Therefore, UASB mode (without recirculation, 0.7 m/h upflow velocity) was used for 30 minutes in every 40 minutes cycle to increase the COD concentration in the sludge bed. As a result, an excellent process performance was shown. The COD removal efficiency increased from 65% to 91% and the reactor could maintain a good physical property of retained sludge (sludge concentration: 33.4 g VSS/L and SVI: 25 mL/g VSS). Furthermore, retained sludge possessed sufficient level of methanogenic activity at 20 degrees C.  相似文献   

15.
A pilot-scale modified submerged membrane bioreactor (SMBR) with the capacity of 18.1 m3d(-1) was developed on the basis of the principle of air-lift internal-loop reactor. Economical aeration intensity of the SMBR was determined as 96 m3m(-2)h(-1) according to hydrodynamic investigation. Corresponding economical air-flow rate was selected as the working air-flow rate in the long-term run. Under economical aeration intensity, the critical flux zone of the modified SMBR was as high as 30-35 Lm(-2)h(-1) when MLSS was less than 13 gL(-1). Therefore, a sub-critical flux of 30 Lm(-2)h(-1) was selected as the working membrane flux in the long-term run. Membrane fouling was effectively controlled by sub-critical flux operation and periodic on-line chemical cleaning in the long-term run. When the average influent CODCr, NH3-N and turbidity were 310 and 44.3 mgL(-1) and 161 NTU, respectively, the average permeate were 38.5 and 19.5 mgL(-1) and 0.96 NTU under hydraulic retention time (HRT) was only 2.8 h. Corresponding removal was 86, 58.2 and 99.4%. DO deficiency caused by high MLSS was demonstrated as the main reason for low NH3-N removal.  相似文献   

16.
In this paper, the feasibility of grey water treatment in a UASB reactor was investigated. The batch recirculation experiments showed that a maximum total-COD removal of 79% can be obtained in grey-water treatment in the UASB reactor. The continuous operational results of a UASB reactor treating grey water at different hydraulic retention time (HRT) of 20, 12 and 8 hours at ambient temperature (14-24 degrees C) showed that 31-41% of total COD was removed. These results were significantly higher than that achieved by a septic tank (11-14%), the most common system for grey water pre-treatment, at HRT of 2-3 days. The relatively lower removal of total COD in the UASB reactor was mainly due to a higher amount of colloidal COD in the grey water, as compared to that reported in domestic wastewater. The grey water had a limited amount of nitrogen, which was mainly in particulate form (80-90%). The UASB reactor removed 24-36% and 10-24% of total nitrogen and total phosphorus, respectively, in the grey water, due to particulate nutrients removal by physical entrapment and sedimentation. The sludge characteristics of the UASB reactor showed that the system had stable performance and the recommended HRT for the reactor is 12 hours.  相似文献   

17.
Biological phosphorus removal with nitrite as election acceptor.   总被引:1,自引:0,他引:1  
Biological phosphorus removal was studied in a sequencing batch reactor (SBR). The results showed that nitrite could be used as electron acceptor in denitrifying phosphorus removal. Feed mode of nitrite had significant influence on denitrifying phosphorus removal. Anoxic phosphorus assimilation rate could reach 10.44 mgP/gSS.h and the percentage of anoxic phosphorus assimilation amount was more than 97% with continuous feed mode. Granular sludge with denitrifying phosphorus removal activity was found in the SBR. The effects of different operational conditions, such as COD loading, settling time, HRT etc., on the formation of granules were also studied.  相似文献   

18.
A single-fibre microfiltration system was employed to investigate the importance of various operating and sludge property parameters to the membrane fouling during sludge filtration. The sludge was obtained from a submerged membrane bioreactor (SMBR). A series of comparative and correlative filtration and fouling tests were conducted on the influence of the operating variables, sludge properties and the liquid-phase organic substances on the membrane fouling development. The test results were analysed statistically with Pearson's correlation coefficients and the stepwise multivariable linear regression. According to the statistical evaluation, the membrane fouling rate has a positive correlation with the biopolymer cluster (BPC) concentration, sludge concentration (mixed liquor suspended solids, MLSS), filtration flux and viscosity, a negative correlation with the cross-flow velocity, and a weak correlation with the extracellular polymeric substances and soluble microbial products. BPC appear to be the most important factor to membrane fouling development during the sludge filtration, followed by the filtration flux and MLSS concentration. The cross-flow rate also is important to the fouling control. It is argued that, during membrane filtration of SMBR sludge, BPC interact with sludge flocs at the membrane surface to facilitate the deposition of the sludge cake layer, leading to serious membrane fouling.  相似文献   

19.
This study investigated the discrepancies between the BOD removal rates measured during short term assays and those measured during continuous activated sludge treatment of bleached kraft mill effluent (BKME). A combination of batch tests and fed batch tests with oxygen uptake rate (OUR), chemical oxygen demand (COD), biochemical oxygen demand (BOD), and mixed liquor volatile suspended solids (MLVSS) measurements were used to characterize the degradation rates for the activated sludge treatment of BKME and to divide the soluble readily biodegradable substrate into two to five separate fractions based on biodegradation rates. The removal rates varied by over an order of magnitude between the most readily degradable substrates (1 x 10(-3) mg COD/mg MLVSS minute), and the more slowly degradable substrates (2 x 10(-5) mg COD/mg MLVSS minute). If the readily biodegradable fraction of BKME was modeled as one substrate, initial rate kinetic measurements from batch tests were heavily influenced by the fractions with the greatest degradation rates, while any remaining BOD in the treated effluent was predominantly from the slowly degradable fraction, giving inconsistent results. Taking the multi-component nature of the wastewater into account, batch test results can be used to predict fed-batch and continuous activated sludge reactor performance.  相似文献   

20.
A large pilot-scale membrane bioreactor (MBR) with a conventional denitrification/nitrification scheme for municipal wastewater treatment has been run for one year under two different aeration strategies in the oxidation/nitrification compartment. During the first five months air supply was provided according to the dissolved-oxygen set-point and the system run as a conventional predenitrification MBR; then, an intermittent aeration strategy based on effluent ammonia nitrogen was adopted in the aerobic compartment in order to assess the impact on process performances in terms of N and P removal, energy consumption and sludge reduction. The experimental inferences show a significant improvement of the effluent quality as COD and total nitrogen, both due to a better utilization of the denitrification potential which is a function of the available electron donor (biodegradable COD) and electron acceptor (nitric nitrogen); particularly, nitrogen removal increased from 67% to 75%. At the same time, a more effective biological phosphorus removal was observed as a consequence of better selection of denitrifying phosphorus accumulating organisms (dPAO). The longer duration of anoxic phases also reflected in a lower excess sludge production (12% decrease) compared with the standard pre-denitrification operation and in a decrease of energy consumption for oxygen supply (about 50%).  相似文献   