1.
A solar adsorption cooling system was constructed in the green building of Shanghai Institute of Building Science. The system consisted of evacuated tube solar collector arrays of area 150 m2, two adsorption chillers with nominal cooling capacity of 8.5 kW for each and a hot water storage tank of 2.5 m3 in volume. A mathematical model of the system was established. According to experimental results under typical weather condition of Shanghai, the average cooling capacity of the system was 15.3 kW during continuous operation for 8 h. The theoretical analysis of the system was verified and found to agree well with the experimental results. The performance analysis showed that solar radiant intensity had a more distinct influence on the performance of solar adsorption cooling system as compared with ambient temperature. It was observed that the cooling capacity increased with the increase of solar collector area, whereas, solar collecting efficiency varied quite contrary. With the increase of water tank volume, cooling capacity decreased, while, the solar collecting efficiency increased. The system performances can be enhanced by increasing the height-to-diameter ratio of water tank. Additionally, it was observed that solar collecting efficiency decreased with the increase of the initial temperature of water in the tank; however, cooling capacity varied on the contrary. Also can be seen is that optimum nondimensional mass flow rate is 0.7 when the specific mass flow rate exceeds 0.012 kg/m2 s.  相似文献   

2.
A solar-powered adsorption chiller with heat and mass recovery cycle was designed and constructed. It consists of a solar water heating unit, a silica gel-water adsorption chiller, a cooling tower and a fan coil unit. The adsorption chiller includes two identical adsorption units and a second stage evaporator with methanol working fluid. The effects of operation parameter on system performance were tested successfully. Test results indicated that the COP (coefficient of performance) and cooling power of the solar-powered adsorption chiller could be improved greatly by optimizing the key operation parameters, such as solar hot water temperature, heating/cooling time, mass recovery time, and chilled water temperature. Under the climatic conditions of daily solar radiation being about 16–21 MJ/m2, this solar-powered adsorption chiller can produce a cooling capacity about 66–90 W per m2 collector area, its daily solar cooling COP is about 0.1–0.13.  相似文献   

3.
《Applied Thermal Engineering》2007,27(8-9):1612-1628
The design and performance of a solar (and/or natural gas) powered adsorption (desiccant-vapor) heat pump for residential cooling (and heating) is described. The entire system is modeled and analyzed: adsorption heat pump itself, ice thermal storage reservoir, and solar collectors. The adsorption heat pump embodies patent pending improvements to the state-of-the-art which elevate coefficient of performance for cooling from a maximum of 1.2 reported in the literature to a conservatively predicted minimum of 1.5. The adsorption device utilizes economical, robust configurations (shell-and-tube) and components (helical annular finned tubes, multi-lumen tubes) commonly employed in heat exchangers in a manner heretofore untried, as well as other enhancements (metal wool to diffuse heat throughout the adsorbent). The vessel is all aluminum and the adsorbent-refrigerant pair is carbon-ammonia. The ice reservoir provides 24 h cooling. Two types of solar collector are determined to be satisfactory at the selected operating temperature of 170 °C: (1) compound parabolic concentrator with high concentration ratio (10+) and automatic tilt adjustment, and (2) evacuated (0.001 atm) flat panel, similar to atmospheric pressure versions employed for domestic water heating.  相似文献   

4.
A conceptual design and performance of a dual-purpose solar continuous adsorption system for domestic refrigeration and water heating is described. Malaysian activated carbon and methanol are used as the adsorbent–adsorbate pair. The heat rejected by the adsorber beds and condensers during the cooling process of the refrigeration part is recovered and used to heat water for the purpose of domestic consumption. In a continuous 24-h cycle, 16.9 MJ/day of heat can be recovered for heating of water in the storage tanks. In the single-purpose intermittent solar adsorption system, this heat is wasted. The total energy input to the dual-purpose system during a 24-h operation is 61.2 MJ/day and the total energy output is 50 MJ/day. The latter is made up of 44.7 MJ/day for water heating and 5.3 MJ/day for ice making. The amount of ice that can be produced is 12 kg/day. Using typical value for the efficiency of evacuated tube collector of water heating system of 65%, the following coefficient of performances (COP's) are obtained: 44% for adsorption refrigeration cycle, 73% for dual-purpose solar water heater, 9.1% for dual-purpose solar adsorption refrigeration and 82.1% for dual-purpose of both solar water heater and refrigerator.  相似文献   

5.
《Applied Energy》2007,84(9):971-983
Performance variations of a solar-powered ejector cooling-system (SECS) using an evacuated-tube collector are presented for Antalya, Aydin, Konya and Urfa cities located in the southern region of Turkey by means of hourly and monthly average ambient temperature and solar radiation meteorological data. A SECS, based on a constant-area ejector flow model and using R-123, was considered. The cooling season and period were taken into account for the 6 months (May–October) and the hours 8:00–17:00, respectively. It was found that the evacuated-tube collector efficiency depending upon the ambient temperature and solar radiation within the day was remarkably varied. However, for all the cities, the cooling capacities of the SECS were very similar. When generator, condenser, and evaporator temperatures were taken, namely, 85 °C, 30 °C and 12 °C, the maximum overall coefficient of performance and the cooling capacity were obtained as 0.197 and 178.26 W/m2, respectively, at 12:00 in August for Aydin. The evacuated-tube collector area per ton cooling was found to be around 21 m2 at noontime in August for all the cities. Furthermore, at the off-design conditions, a performance map of the system was derived and discussed. It was determined that the SECS could be used for office-cooling purposes during the hours (8:00–15:00) in the southern region of Turkey.  相似文献   

6.
Solar thermal driven cooling systems for residential applications are a promising alternative to electric compression chillers, although its market introduction still represents a challenge, mainly due to the higher investment costs. The most common system configuration is an absorption chiller driven by a solar thermal system, backed up by a secondary heating source, normally a gas boiler. Heat storage in the primary (solar) circuit is mandatory to stabilize and extend the operation of the chiller, whereas a cold storage tank is not so common.This paper deals with the selection of the most suitable configuration for residential cooling systems with solar energy. In Spain, where cooling needs are usually higher than heating needs, the interest of a reversible heat pump as auxiliary system and a secondary cooling storage are analyzed.A complete TRNSYS model has been developed to compare a configuration with just hot storage (of typical capacity 40 L/m2 of solar collector surface) and a configuration with both, hot and cool storages. The most suitable configuration is very sensible to the solar collector area. As the collector area increases, the advantages of a cool storage vanish. Increasing the collector area tends to increase the temperature of the hot storage, leading to higher thermal losses in both the collector and the tank. When the storage volume is concentrated in one tank, these effects are mitigated. The effect of other variables on the optimal configuration are also analyzed: collector efficiency curve, COP of the absorption chiller, storage size, and temperature set-points of the chillers.  相似文献   

7.
Based on the mechanism of falling film evaporation condensation, a new four-stage distillation unit with triple-effect regeneration has been designed, constructed and field tested. The seawater desalination system is driven by 80 m2 all-glass vacuum tube solar collection system with an additional 1 kW wind power system to provide electricity for pumps. The field testing and monitoring of the system had been carried out under the real weather condition for 2 years. The results show that the water production of the system for per unit of solar collector area could reach up to more than 12 kg/m2/day under the fine weather conditions. Water production of the system was stable in long period and the annual production could reach to 250 tons in northern China. The economic performance of the system is also discussed. The cost of water production is estimated approximately 4.6 Dollar/ton for the 15-year service life.  相似文献   

8.
In this study, performance assessment of an integrated cooling plant having both free cooling system and solar powered single-effect lithium bromide–water absorption chiller in operation since August 2002 in Oberhausen, Germany, was performed. A floor space of 270 m2 is air-conditioned by the plant. The plant includes 35.17 kW cooling (10-RT) absorption chiller, vacuum tube collectors’ aperture area of 108 m2, hot water storage capacity of 6.8 m3, cold water storage capacity of 1.5 m3 and a 134 kW cooling tower. The results show that free cooling in some cooling months can be up to 70% while it is about 25% during the 5 years period of the plant operation. For sunny clear sky days with equal incident solar radiation, the daily solar heat fraction ranged from 0.33 to 0.41, collectors’ field efficiency ranged from 0.352 to 0.492 and chiller COP varies from 0.37 to 0.81, respectively. The monthly average value of solar heat fraction varies from 31.1% up to 100% and the five years average value of about 60%. The monthly average collectors’ field efficiency value varies from 34.1% up 41.8% and the five-year average value amounts about 28.3%. Based on the obtained results, the specific collector area is 4.23 (m2/kWcold) and the solar energy system support of the institute heating system for the duration from August 2002 to November 2007 is 8124 kWh.  相似文献   

9.
《Applied Thermal Engineering》2007,27(2-3):450-456
In this study, the thermo-economic optimization analysis to determinate economically optimal dimensions of collector area and storage volume in domestic solar heating systems with seasonal storage is presented. For this purpose, a formulation based on the simplified P1 and P2 method is developed and solved by using MATLAB optimization Toolbox for five climatically different locations of Turkey. The results showed that the required optimum collector area in Adana (37 °N) for reaching maximum savings is 36 m2/house and 65 m2/house in Erzurum (39 °N) for same storage volume (1000 m3). The effects of collector efficiency on solar fraction and savings are investigated. The simulation results showed that the solar fraction and savings of the selective flat plate collector systems are higher than the other black paint flat plate collector systems.  相似文献   

10.
Despite its attractiveness, solar cooling technology is still in an early stage of development. Most installations currently in operation show differences in the collector area per kilowatt of cooling capacity that cannot be explained only by project-specific circumstances. The purpose of this paper was twofold. First, to answer some questions that came up during the design process of the plant by using a TRNSYS system model and statistical tools. Second, to gain knowledge about the plant operation and validate the TRNSYS model through measured data. The system was equipped with a flat-plate collector field of 38.4 m2. A lithium bromide-water single-effect absorption chiller (17.6 kW) was selected in order to provide chilled water to fan-coils. Performance data were registered at the solar plant working with a 1000-l heat storage tank and a required temperature of 80 °C to drive the absorption machine. An average of 29% of the solar energy incident on the solar collectors’ surface was transferred to the hot water storage. The registered average COP of the absorption chiller was 0.691. The performance data were compared with the values predicted by the TRNSYS plant model and a high level of agreement was obtained.  相似文献   

11.
In this paper, a solar-powered compound system for heating and cooling was designed and constructed in a golf course in Taiwan. An integrated, two-bed, closed-type adsorption chiller was developed in the Industrial Technology Research Institute in Taiwan. Plate fin and tube heat exchangers were adopted as an adsorber and evaporator/condenser. Some test runs have been conducted in the laboratory. Under the test conditions of 80 °C hot water, 30 °C cooling water, and 14 °C chilled water inlet temperatures, a cooling power of 9 kW and a COP (coefficient of performance for cooling) of 0.37 can be achieved. It has provided a SCP (specific cooling power) of about 72 W/(kg adsorbent). Some field tests have been performed from July to October 2006 for providing air-conditioning and hot water. The efficiency of the collector field lies in 18.5–32.4%, with an average value of 27.3%. The daily average COP of the adsorption chiller lies in 33.8–49.7%, with an average COP of 40.3% and an average cooling power of 7.79 kW. A typical daily operation shows that the efficiency of the solar heating system, the adsorption cooling and the entirely solar cooling system is 28.4%, 45.2%, and 12.8%, respectively.  相似文献   

12.
Mehmet Bilgili 《Solar Energy》2011,85(11):2720-2731
A solar electric-vapor compression refrigeration (SE-VCR) system has been proposed in this study. The SE-VCR system was investigated for different evaporating temperatures and months in Adana city located in the southern region of Turkey. First, the hourly cooling load capacities (heat gain) of a sample building during the 23rd days of May, June, July, August and September months were determined by using meteorological data such as hourly average solar radiations and atmospheric temperatures. The hourly total heat gain of the sample building comprised of wall, window, humans, illumination and devices were determined by using the Cooling Load Hourly Analysis Program (HAP) 4.4. Then, the hourly variations of various parameters such as coefficient of the performance, condenser capacity and compressor power consumption were calculated. In addition, the minimum photovoltaic panel surface area was determined to meet the compressor power demand according to the hourly average solar radiation data. For evaporating temperature Te = 0 °C, the maximum compressor power consumption was obtained as 2.53 kW at 15:00 PM on August 23. The required photovoltaic panel surface area was found to be around 31.26 m2. It was determined that the SE-VCR system could be used for home/office-cooling purposes during the day in the southern region of Turkey.  相似文献   

13.
《Energy Conversion and Management》2005,46(13-14):2032-2041
A solar adsorption ice maker with activated carbon–methanol adsorption pair was developed for a practical application. Its main features include utilization of a water cooled condenser and removing all valves in the refrigerant circuit except the one that is necessary for refrigerant charging. Year round performance tests of the solar ice maker were performed in Kunming, Yunnan Province, China. Test results show that the COP (coefficient of performance) of the solar ice maker is about 0.083–0.127, and its daily ice production varies within the range of 3.2–6.5 kg/m2 under the climatic conditions of daily solar radiation on the surface of the adsorbent bed being about 15–23 MJ/m2 and the daily average ambient temperature being within 7.7–21.1 °C. The suitable daily solar radiation under which the solar ice maker can run effectively in Kunming is above 16 MJ/m2.  相似文献   

14.
A comprehensive improvement of the mathematical model for the so called transfer function method is presented in this study. This improved transfer function method can estimate the traditional solar collector parameters such as zero loss coefficient and heat loss coefficient. Two new collector parameters t and mfCf are obtained. t is a time scale parameter which can indicate the heat transfer ability of the solar collector. mfCf can be used to calculate the fluid volume content in the solar collector or to validate the regression process by comparing it to the physical fluid volume content if known. Experiments were carried out under dynamic test conditions and then test data were processed using multi-linear regression method to get collector parameters with statistic analysis. A comparison of the collector parameters obtained from the improved transfer function (ITF) method and the quasi-dynamic test (QDT) method is carried out. The results show that the improved transfer function method can accurately obtain reasonable collector parameters. The influence of different averaging time intervals is investigated. Based on the investigation it is recommended to use on line calculation if applicable for the second-order differential term with 6–9 min as the best averaging time interval. The measured and predicted collector power output of the solar collector are compared during a test of 13 days continuously both for the ITF method and the QDT method. The maximum and averaging error is 53.87 W/m2 and 5.22 W/m2 respectively of the ITF method while 64.13 W/m2 and 6.22 W/m2 of the QDT method. Scatter and relative error distribution of the measured power output versus the predicted power output is also plotted for the two methods. No matter in either error analysis or scatter distribution, the ITF method is more accurate than the QDT method in predicting the power output of a solar collector.In conclusion, all the results show that the improved transfer function method can accurately and robustly estimate solar collector parameters and predict solar collector thermal performance under dynamic test conditions.  相似文献   

15.
The work presented in this article aims to investigate a PV/T hybrid solar window on a system level. A PV/T hybrid is an absorber on which solar cells have been laminated. The solar window is a PV/T hybrid collector with tiltable insulated reflectors integrated into a window. It simultaneously replaces thermal collectors, PV-modules and sunshade. The building integration lowers the total price of the construction since the collector utilizes the frame and the glazing in the window. When it is placed in the window a complex interaction takes place. On the positive side is the reduction of the thermal losses due to the insulated reflectors. On the negative side is the blocking of solar radiation that would otherwise heat the building passively. This limits the performance of the solar window since a photon can only be used once. To investigate the sum of such complex interaction a system analysis has to be performed. In this paper results are presented from such a system analysis showing both benefits and problems with the product. The building system with individual solar energy components, i.e. solar collector and PV modules, of the same size as the solar window, uses 1100 kW h less auxiliary energy than the system with a solar window. However, the solar window system uses 600 kW h less auxiliary energy than a system with no solar collector.  相似文献   

16.
《Energy》2006,31(14):2710-2727
The main objective of the work is to demonstrate experimentally and numerically the performance of a simple solar distillation unit that is based on the multiple condensation–evaporation cycle. The pilot plant was designed, fabricated, tested and simulated at the solar energy laboratory, Mattarria Faculty of Engineering, Cairo, Egypt. The distillation chamber consists of a humidifier (evaporator) and a dehumidifier (condenser) units. The circulation of air in the two units is maintained by natural convection. The cold salt water is preheated inside the distillation unit before exchanging heat with the solar collector loop. This plant has a flat-plate collector field area of 3.1 m2, it constitutes a closed loop with its own storage tank. The research is then carried out to evaluate the unit performance of such design and to estimate the fraction factor of the solar system to the load. A numerical simulation was developed for the system being considered. A detailed annual performance of the system is presented. The annual variation of the temperatures and useful heat gain were estimated for the system components. In addition, the optimum collector area by which the system has the maximum life-cycle savings and solar fraction was obtained. The comparison between the numerical and experimental results are accepted. The multiple-effect distillation unit that is considered in the study produces 24 l/day of distilled water. The system performance can be accepted according to the previous edited results.  相似文献   

17.
The present study developed a maximum-power point tracking control (MPPT) technology for solar heating system to minimize the pumping power consumption at an optimal heat collection. The net solar energy gain Qnet (=Qs ? Wp/ηe) was experimentally found to be the cost function for MPPT with maximum point. The feedback tracking control system was developed to track the optimal Qnet (denoted Qmax). A tracking filter which was derived from the thermal analytical model of the solar heating system was used to determine the instantaneous tracking target Qmax(t). The system transfer-function model of solar heating system was also derived experimentally using a step response test and used in the design of tracking feedback control system. The PI controller was designed for a tracking target Qmax(t) with a quadratic time function. The MPPT control system was implemented using a microprocessor-based controller and the test results show good tracking performance with small tracking errors. It is seen that the average mass flow rate for the specific test periods in five different days is between 18.1 and 22.9 kg/min with average pumping power between 77 and 140 W, which is greatly reduced as compared to the standard flow rate at 31 kg/min and pumping power 450 W which is based on the flow rate 0.02 kg/s m2 defined in the ANSI/ASHRAE 93-1986 Standard and the total collector area 25.9 m2. The average net solar heat collected Qnet is between 8.62 and 14.1 kW depending on weather condition. The MPPT control of solar heating system has been verified to be able to minimize the pumping energy consumption with optimal solar heat collection.  相似文献   

18.
Institutional buildings contain different types of functional spaces which require different types of heating, ventilating and air conditioning (HVAC) systems. In addition, institutional buildings should be designed to maintain an optimal indoor comfort condition with minimal energy consumption and minimal negative environmental impact. Recently there has been a significant interest in implementing desiccant cooling technologies within institutional buildings. Solar desiccant cooling systems are reliable in performance, environmentally friendly and capable of improving indoor air quality at a lower cost. In this study, a solar desiccant cooling system for an institutional building in subtropical Queensland (Australia) is assessed using TRNSYS 16 software. This system has been designed and installed at the Rockhampton campus of Central Queensland University. The system's technical performance, economic analysis, energy savings, and avoided gas emission are quantified in reference to a conventional HVAC system under the influence of Rockhampton's typical meteorological year. The technical and economic parameters that are used to assess the system's viability are: coefficient of performance (COP), solar fraction, life cycle analysis, payback period, present worth factor and the avoided gas emission. Results showed that, the installed cooling system at Central Queensland University which consists of 10 m2 of solar collectors and a 0.400 m3 of hot water storage tank, achieved a 0.7 COP and 22% of solar fraction during the cooling season. These values can be boosted to 1.2 COP and 69% respectively if 20 m2 of evacuated tube collector's area and 1.5 m3 of solar hot water storage volume are installed.  相似文献   

19.
《Applied Thermal Engineering》2007,27(2-3):442-449
Solar energy integrated with the building is an important approach for the synchronous development of solar energy and architecture. The energy gain of the solar collector integrated with the pitched roof has been greatly influenced by the roof azimuth and tilted angle. Investment cost of the collectors is mainly decided by the size of the collector area. Accordingly, it is significant for solar building design to economically determinate the area compensation of the solar collector at different azimuth and tilted angles. Take Kunming and Beijing as examples, area compensation for the flat-plate tube-fin solar collector used in southern regions and the evacuated tube collector with cylindrical absorbers used in northern regions in China have been theoretically calculated. The results to some extent show that the daily horizontal solar radiation, ambient temperature, the azimuth and tilted angle of the collector integrated into the roof have an influence on the area compensation. The azimuth angle and tilted angle of the roof are the main factors that influence the A/A0, which is defined as the collector area ratio of the non-south-facing collectors to the south-facing ones with the optimal tilted angle. Comparative studies found that the range of A/A0 for the evacuated tube collector used in the northern regions is close to that for the flat-plate tube-fin solar collector used in the southern regions. When the pitched roof tilted angle β  [25°, 45°] and the azimuth angle ∣γ  30°, the collectors can intercept a lot of solar radiant-energy. Considering the economic situations of the ordinary consumers in China, the optimal area compensation A/A0  1.30 is recommended in this paper.  相似文献   

20.
Investigating the complicated thermal physics mechanisms of the parabolic trough solar collector systems plays a vital role in efficiently utilizing the solar energy. In this paper, the least squares support vector machine (LSSVM) method is developed to model and optimize the parabolic trough solar collector system. Numerical simulations are implemented to evaluate the feasibility and efficiency of the LSSVM method, where the sample data derived from the experiment and the simulation results of two solar collector systems with 30 m2 and 600 m2 solar fields, and the complicated relationship between the solar collector efficiency and the solar flux, the flow rate and the inlet temperature of the heat transfer fluid (HTF) is extracted. Some basic rules, such as the solar collector efficiency increases with the increase of the solar flux and the flow rate of the heat transfer fluid, and decreases with the increase of the inlet temperature of the HTF, are obtained, which indicates the LSSVM method is competent to optimize the solar collector systems. As a result, the new approach will provide meaningful data for developing the parabolic trough solar thermal power plant in China.  相似文献   