首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
基于硼掺杂金刚石电极的酚生物传感器的研究   总被引:1,自引:0,他引:1  
该文研究了以硼掺杂金刚石为基底电极的酪氨酸酶传感器.该酶传感器对酚的催化作用强于以玻碳为基底电极的酪氨酸酶传感器.在浓度为1.0×10-8~1.0×10-5mol/L的范围内传感器对邻苯二酚的响应具有良好的线性关系,检测下限为5.2×10-9mol/L.酶电极的Michaelis-Metent常数(Kapp m)为33.65μmol/L.酶电极对苯酚和对甲苯酚也有良好的响应,线性范围分别为:5.0×10-8~2.0×10-5mol/L、5.0×10-8~5.0×10-6 mol/L.酶传感器有较好的稳定性和重现性.  相似文献   

2.
利用氨基功能化离子液体修饰石墨烯(IL-GR)的独特性质,以壳聚糖(CHI)为交联剂,首先在玻碳电极表面固定IL-GR,然后吸附乙酰胆碱酯酶(AChE)制得新型有机磷检测酶电极(AChE/IL-GR/CHI/GCE),并用于卷心菜样品中毒死蜱农药残留的测定。采用透射电镜(TEM)表征了IL-GR的形貌,采用循环伏安法(CV)和差示脉冲伏安法(DPV)研究了酶电极的电化学性质。结果表明,在优化的实验条件下,抑制率(I%)与毒死蜱浓度的对数在1.0×10-10mol/L~1.0×10-5mol/L范围内呈良好的线性关系,检出限为7.0×10-12mol/L(S/N=3)。测定了卷心菜中毒死蜱的含量,回收率为92.3%~108.6%。  相似文献   

3.
酶在电极上的固定是酶传感器制备中的重要环节,它直接影响酶传感器的检测性能.该文利用静电吸附的自组装法以碳纳米管为载体将酶固定在电极上来制备酶传感器,该酶传感器制备过程简单、稳定性好、组装到电极表面的酶的量多并可保持其生物活性,可检测浓度在1.0×10-6~5.4×10-5mol/L范围内的H2O2,最低检测限为5.3×10-7mol/L.这种制备方法为检测农药残留生物传感器的制备提供了一种新的方法.  相似文献   

4.
光电协同催化生物传感器用于检测有机磷农药的研究   总被引:2,自引:2,他引:0  
该文制备了AChE/PbO2/TiO2/Ti电流型生物传感器,并用原子力显微镜(AFM)对该电极的表面形貌进行了表征,结合流动注射技术将其用于有机磷农药(OPs)的检测.该文利用有机磷农药对乙酰胆碱酯酶的抑制作用,以硫代乙酰胆碱(ATCh)为底物,实现了对有机磷农药敌百虫的检测.实践表明,PbO2/TiO,修饰的酶生物传感器,具有光电协同催化性能,响应速度快,检测灵敏度高,稳定性好;固定在传感器上的乙酰胆碱酯酶具有良好的酶动力学响应,其表观米氏常数(KappM)为1.34mmol/L.对敌百虫的最低检测限达到1.0 nmol/L.  相似文献   

5.
利用气相沉积方法在玻碳电极表面得到二氧化钛凝胶膜,并在电极表面同时固定5'-核苷酸酶(5'-NT)和辣根过氧化物酶(HRP),构建了一种新型快速测定肌苷酸(IMP)含量的安培传感电极(5'-NT-HRP/GCE).在溶解氧存在的条件下,IMP被凝胶膜中的5'-NT催化氧化,通过产物H2O2在电位-150 mV下被HRP酶催化还原的电化学响应对IMP进行测定.在邻苯二酚存在下,该传感器对IMP表现出快速的响应(响应时间小于10 s).该电极对IMP的测定具有较宽的线性范围(1×10-6-2×10-4mol/L)和较低的检测限(0.5×10-6mol/L).该电极对IMP的测定具有很高的准确度和良好的重现性.除抗坏血酸以外,与IMP共存的其它物质对其测定没有干扰.结果表明,该电极显示出很好的重现性和稳定性,能用于鸡肉中IMP的在线检测.  相似文献   

6.
利用气相沉积方法在玻碳电极表面得到二氧化钛凝胶膜,并在电极表面同时固定5'-核苷酸酶(5'-NT)和辣根过氧化物酶(HRP),构建了一种新型快速测定肌苷酸(IMP)含量的安培传感电极(5'-NT-HRP/GCE).在溶解氧存在的条件下,IMP被凝胶膜中的5'-NT催化氧化,通过产物H2O2在电位-150 mV下被HRP酶催化还原的电化学响应对IMP进行测定.在邻苯二酚存在下,该传感器对IMP表现出快速的响应(响应时间小于10 s).该电极对IMP的测定具有较宽的线性范围(1×10-6-2×10-4mol/L)和较低的检测限(0.5×10-6mol/L).该电极对IMP的测定具有很高的准确度和良好的重现性.除抗坏血酸以外,与IMP共存的其它物质对其测定没有干扰.结果表明,该电极显示出很好的重现性和稳定性,能用于鸡肉中IMP的在线检测.  相似文献   

7.
该文报道了一种用于检测有机磷农药的安培生物传感器,将钴(Ⅱ)-4,4′,4",4 四氨基酞菁(CoTAPc)单体电聚合到一支玻碳电极上作为硫代胆碱电化学氧化的电催化剂,通过交联的方法将乙酰胆碱酯酶(AChE)固定在醋酸纤维膜上,再将该酶膜固定于聚四氨基钴酞菁(p-CoTAPc)修饰电极表面.采用10min的温育时间,百分抑制率与对硫磷或乐果浓度的对数值都在1.0×10-9~1.0×10-6mol/L浓度范围内呈线性关系,检测限分别可达7.0×10-100 mol/L和2.6×10-100 mol/L.农药对AChE的抑制作用产生后,用2-吡啶醛肟甲基氯化物(2-PAM)可以有效地使酶膜再生活化.  相似文献   

8.
采用石墨电极作为基础电极 ,将待测兔抗原用丝素蛋白溶液固定在基础电极表面 ,根据抗原抗体的单一性识别原理 ,选用山羊抗兔IgG HRP抗体与其选择性结合制作而成 .利用H2 O2 将该生物敏传感器的电位响应信号放大 ,采用直接电位法检测兔抗原的浓度 .结果符合奈斯特响应 ,兔抗原的最低检测浓度 1.0× 10 -10 mol/L ,线性范围 1.0× 10 -8~ 1.0× 10 -10 mol/L ,响应时间为 15s .这种以固定化抗原结合酶标抗体量的多少作为检测抗原浓度的新型酶免疫电极 ,在临床检测、生物医学研究等领域中有着广阔的应用前景  相似文献   

9.
以无创检测人体血糖为应用需求,采用高灵敏度锇氧化还原聚合物修饰在薄膜电极上,并通过戊二醛交联法固定酶分子制备成新型生物传感器。实验结果表明:在0~700μmol/L的葡萄糖标准浓度范围内,传感器灵敏度为23.955 nA/(μmol.L-1),最低检测限为0.3μmol/L,相关系数为0.999;在标准皮下葡萄糖浓度0~19mmol/L浓度范围内,被抽取出的葡萄糖电流响应值与皮下葡萄糖的浓度成线性关系,线性相关系数为0.994,灵敏度为4.03 nA/(mmol.L-1);单只传感器对100μmol/L葡萄糖检测的精度为4.07%(n=10),不同传感器之间对100μmol/L葡萄糖测量的精度为3.22%(n=10),在4℃条件下,传感器的寿命可达450 d。  相似文献   

10.
制备了一种基于活化的玻碳电极的新型电化学DNA生物传感器,可用于膀胱癌DNA的检测.通过循环伏安法(CV)实现玻碳电极在NaOH溶液中的刻蚀,使电极表面负载大量官能团,为DNA提供连接位点,由Laviron方程计算得到玻碳电极表面的羧基浓度为 1.022×10-6 mol/cm2.亚甲基蓝(MB)作为电化学检测的杂交指示剂.采用原子力显微镜(AFM)对刻蚀后的电极进行了形貌表征.在最优杂交条件下,通过差分脉冲法(DPV)计算出最佳检测限为5.677×10-13 mol/L(n=5),适用目标 DNA浓度范围1×10-8 mol/L~1×10-12 mol/L.该传感器有望用于实际样品中膀胱癌DNA的快速检测.  相似文献   

11.
电化学式葡萄糖传感器阳极的研究   总被引:1,自引:0,他引:1  
制备了一种石墨粉含量高的混合物导电材料,研究了该材料的导电性能及水中贮存稳定性,并将其作为电化学式葡萄糖传感器的阳极,以此电极作为固定化酶载体得到的葡萄糖氧化酶电极对葡萄糖的响应时间为20 ~30 s、灵敏度为60 nA/(mmol·L-1) 、线性响应范围为0 .02 ~7 .0 m mol/L,在水溶液中储存20 天,传感器的响应值基本保持不变。  相似文献   

12.
报导在平衡双注照相乳化过程中用AgBr,AgCl单晶电极测定P^Br(P^Cl,P^Ag和pH)值,用微机调控银盐(AgNO3)和卤盐(KBr或KCl)的流量,采用电极流动注入分析法EFIA(ElectrodeFlowInjectionAnalysis)保持在照相乳化中所设定的P^Br(或P^cl)值,从而得到了颗粒分布均匀和立方晶形的AgX晶体,增加了照相乳化的感光度。  相似文献   

13.
A flexible vertically stacked flexible polychromatic color‐tunable OLED has been developed by means of low resistive intermediate electrode technology. The polychromatic OLED has a capability to show 16 million colors with 105% National Television Committee Standard (NTSC) color reproduction. The device can produce arbitrary shape with arbitrary colors, suitable for artistic expressions, just as many as those used in information displays. Independently controlled red, green, and blue light‐emitting layers are stacked vertically. With conventional indium tin oxide technology, because of the temperature restriction, it was quite difficult to achieve low resistance on plastic substrate. The reported numbers were all more than 80 Ω/□. According to the surface mobility control using Fick's law analysis, low sheet resistance 7.34 Ω/□ on plastic film was developed. At first, flexible 7.17 cm2 transparent OLED was fabricated for the performance confirmation of transparent electrode. And then polychromatic color‐tunable OLED with the same size were successfully fabricated on plastic. With optical length optimization for each color stack of polychromatic OLED, more than 100% color reproduction in National Television Committee Standard was achieved by stack design. The polychromatic device can be used for colored illumination, as well as for organic‐light‐emitting display pixels for three times emission than conventional pixel design. The device is fabricated on plastic substrate so that the polychromatic organic‐light‐emitting‐diode device is manufacturable with roll‐to‐roll production line.  相似文献   

14.
针对传统Ag/AgCl胶状电极在长期心电监护中出现的问题和近年来可穿戴式健康监测的发展需求,对可用于心电信号采集的新型传感器技术——织物电极技术进行了综述。介绍了干电极、织物电极的概念;从有源电极和无源电极两方面分别对织物电极技术研究进展进行了分析;从制作工艺、导体材质、依托载体、电化学性能等织物电极技术进行了讨论;分析了目前织物电极在市场应用中的制约因素,并对未来织物电极技术的发展方向进行了展望。  相似文献   

15.
研制了一种用猪肾修饰的碳糊电极,线性范围为1×10-5~4.5×10-3mol·L-1,检出下限为2.5×10-6mol·L-1,并能较好地抵抗组氨酸的干扰。文章对组胺在电极表面的反应机理作了探讨。  相似文献   

16.
The artificial eye functions similar to a camera, in which light beams pass into a regulator and are modulated, and then transmitted by a wireless scheme, The aim of the study is to modify the structure of a traditional biphasic stimulation current circuit of a retinal prosthesis, comprising four parts: a camera device, a wireless transmitting unit, a retinal chip, a micro stimulus electrodes unit, and the device of the direction epiretina, which includes a digital-analog converter, an active-feedback current mirror, a demultiplexer, and a two-way control circuit. To this stimulation circuit, an inverter is added, resulting in the formation of more symmetrical positive and negative waveforms. In the simulation, a sufficient maximal current of 600 μA at 10 kΩ is applied and a driven voltage lower than that in previous studies obtained.  相似文献   

17.
飞行器在空中飞行时因为各种原因产生的静电放电可能导致其油箱的起火爆炸,静电放电产生的辐射还会对飞行器的通讯和导航系统造成干扰,这就需要飞行器的表面材料具有一定的防静电性能。表面电阻率是衡量材料防静电性能的一个重要参数,飞行器在空中高速运动过程中会因与大气摩擦而产生很高的热量,因此,测量高温条件下材料的表面电阻率尤为重要。对于常温态下材料的表面电阻率的测试有三电极法、两电极法等测试方法。本文通过对比分析三电极法和两电极法,在两电极法的基础上提出了高温条件下表面材料电阻测试方法,并构建了高温条件下材料表面电阻率测试系统。通过对某材料随温度升高的表面电阻率的测试,证明该方法的可行性。  相似文献   

18.
作者提出一种用微生物电极测定制剂中链霉素的电流测定法。本法的原理是基于链霉素对埃希氏大肠杆菌的呼吸的抑制作用。溶解氧电极测定培养3h后的埃希氏大肠杆菌呼吸被抑制的程度,以定链霉素量。测得链霉素浓度在10~70μg/mL的范围内,电流改变值(△i)与链霉素浓度呈线性关系。用本法测得的制剂中链霉素量与制剂的标称量相当一致。  相似文献   

19.
Three synthesized platinum(II) complexes, [PtR2(NN)] (R = Me, p-MeC6H4 and p-MeOC6H4; NN = 2,2′-bipyridyl), were studied to characterize their ability as an anion carrier in a PVC membrane electrode. The polymeric membrane electrodes (PME) and also coated glassy carbon electrodes (CGCE) prepared with [Pt(p-MeOC6H4)2(NN)] showed excellent response characteristics to perchlorate ions. The electrodes exhibited Nernstian responses to ClO4 ions over a wide concentration range from 5 × 10−7 to 4.0 × 10−1 M for PME and 1.5 × 10−7 to 2.7 × 10−1 M for CGCE with low detection limits (4.0 × 10−7 M for PME and 1.0 × 10−7 M for CGCE). The electrodes possess fast response time, satisfactory reproducibility, appropriate lifetime and, most importantly, good selectivity toward ClO4 relative to a variety of other common anions. The potentiometric response of the electrodes is independent of the pH of the test solution in the pH range 2.5–9.5. The proposed sensors were used in potentiometric determination of perchlorate ions in mineral water, urine samples and also samples containing interfering anions. The interaction of the ionophore with perchlorate ions was shown by UV–vis spectroscopy.  相似文献   

20.
制备一种可供活体测量的针状微型pH传感器。以高纯度Pt丝为基体,PVC为载体,α—萘胺为活性物质,THF为溶剂制成涂丝H+离子选择性电极。该电极在pH=2~11范围内成良好的线性响应,平均响应斜率为48mV/pH,抗干扰能力强,相对标准偏差在2%以内,响应时间小于10 s。其针状结构在在体测量中应用方便。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号