首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in water and suspended particulate matter (SPM) collected from the Xijiang River, China, were measured by the quarter from September 2005 to June 2006. Total PCDD/F concentration ranged from 2.659 to 4.596pg/L for water and from 562.4 to 3259.5pg/g for SPM. Concentrations were high in summer and low in winter. I-TEQ values in water and SPM were low, ranging from 0.012 to 0.075pg/L, with a mean value of 0.039pg/L. Calculated annual loadings of total PCDD/Fs and I-TEQ were 8.55kg and 0.026kg, respectively. Composition and homologue distribution of PCDD/Fs were varied because of large seasonal differences in discharge from the Xijiang River into the South China Sea. Comparison of the PCDD/Fs homologue and congener profiles of atmospheric deposition, soil, and water revealed that soil was the dominant source of PCDD/Fs in the Xijiang River. Industrial effluents were also possible sources of PCDD/Fs. A good correlation between logK(oc) and logK(ow) was observed for 2,3,7,8-substituted PCDDs and PCDFs and correlation coefficients were 0.71 and 0.84, indicating organic matter in SPM played a dominant role in PCDD/Fs partition between SPM and water.  相似文献   

2.
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in the surrounding environment (outdoor) and workplace air of two municipal solid waste incinerators (MSWIs, T and M) were characterized and compared. T and M represented two typical municipal solid waste incinerators in the north of Taiwan, which have different processes for controlling the PCDD/F emissions. The results of this study are summarized as follows. (1) The total PCDD/F and the total PCDD/F WHO-TEQ concentrations in the workplace air were 5-13 and 5-15 times higher than those in the outdoor air, respectively. Obviously, it is worthwhile to explore more on health risk assessment for exposure of PCDD/Fs emitted from MSWIs, particularly in the workplace air. (2) Mean total PCDD/F I-TEQ concentrations in the outdoor air ranged between 0.0216 and 0.155 pg I-TEQ/Nm(3) and averaged 0.0783 pg I-TEQ/Nm(3) (0.0828 pg WHO-TEQ/Nm(3)) during two seasons for two MSWIs, which were 6.5-fold higher than that of a remote site (0.0119 pg I-TEQ/Nm(3) or 0.0132 pg WHO-TEQ/Nm(3)) in Taiwan. However, the above outdoor air concentration levels in the MSWIs were still much lower than the air quality limitation of PCDD/Fs (0.6 pg I-TEQ/Nm(3)) in Japan []. (3) PCDFs were the primary toxicity distributors for PCDD/Fs in the outdoor air, since the ratios of PCDDs/PCDFs (I-TEQ) at all sampling sites ranged from 0.180 to 0.492 and were less than unity. (4) The OCDD, OCDF, 1,2,3,4,6,7,8-HpCDD and 1,2,3,4,6,7,8-HpCDF were the four dominant species in both workplace and outdoor air near MSWIs. (5) By spraying water on and wetting both the fly and bottom ashes, the mean total PCDD/F I-TEQ concentration in the workplace air was reduced 86.9% in the T MSWI. The above results indicate an appropriate improving action did inhibit the fugitive emission of PCDD/Fs and reduce the health risk of workers during work handling ashes in MSWIs.  相似文献   

3.
In this study, agriculture soil in Taiwan has been sampled and analyzed to determine the background level of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/DF) in the agricultural and nature preserve areas. Another objective is to investigate relationship between soil characteristics and air deposition in Taiwan. The results indicate that in nature preserve areas the topsoil shows an extraordinary profile of PCDD/DF compared to that in the air deposition. The PCDD/DF levels of the low-contaminated agricultural soils are compatible with those of the nature preserves soils. However, in the highly-contaminated agricultural soils, there is an abrupt jump in their concentrations, 10-100 times higher. The overall I-TEQ values of the background topsoils range from 0.101 to 15.2 ng I-TEQ/kg. Near industrial/urban areas in Taiwan the PCDD/DF are slightly higher compared to those in the low concentration group. Typically, the PCDD/DF background values found in this survey fall in the 90% confidence interval and can thus, be deemed the background levels in Taiwan. Ninety-five percent of these data are below the European and American soil standard of 10 ng I-TEQ/kg d.w. The PCDD/DF profile with one neighborhood soil sample was shown no significant difference.  相似文献   

4.
Thermal treatment technology was used to remove polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from heavily contaminated soil. For a soil with an original PCDD/F content of 35,970ng International Toxic Equivalents (I-TEQ)/kg, >99.99% PCDD/F removal efficiency was obtained with a primary furnace at two different treatment temperatures (750 degrees C and 850 degrees C), while a secondary furnace at 1200 degrees C gave >98% decomposition efficiency. The total PCDD/F I-TEQ contents in treated soils at 750 degrees C and 850 degrees C were 1.56ngI-TEQ/kg and 2.15ngI-TEQ/kg, respectively, which were far below the soil pollution standard of Taiwan (1000ngI-TEQ/kg soil). Although air pollution control devices had significant effects on the removal of PCDD/Fs, the total I-TEQ concentrations in the upstream flue gas of PUF cartridge at 750 degrees C and 850 degrees C (2.61ngI-TEQ/Nm(3) and 2.38ngI-TEQ/Nm(3), respectively) were still higher than the stationary emission limit of the Taiwan EPA (0.5ngI-TEQ/Nm(3)). The above results also suggested that additional APCDs, such as activated carbon injection in front of the filter are needed to enhance PCDD/F removal efficiency.  相似文献   

5.
The distribution and concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (dioxin-like PCBs, also called co-PCBs) in a typical area of eastern China were evaluated by analysis of 21 soil and 6 sediment samples. The range of WHO-TEQ values for the PCDD/Fs and dioxin-like PCBs in 17 soil samples representing the background investigation in the study area was 0.017-5.04 pg g(-1) (dry weight, dw), with a mean value 0.967(+/-1.361)pg g(-1) and medium value 0.348 pg g(-1), which indicates that the levels of PCDD/Fs and dioxin-like PCBs over the major part of this district were low. However, the WHO-TEQ values (6.52-16.7 pg g(-1) dw) for PCDD/Fs and dioxin-like PCBs in soil samples to the leeward of a known contaminated disassembly industrial park were much higher than that of the background investigation, and the levels of sediment samples downstream of this area were in the range 2.25-34.6 pg g(-1) (dw). The levels of WHO-TEQ in soil and sediment samples decreased with an increase in distance from the researched pollution source. The principal component analysis demonstrated that the PCDD/Fs and dioxin-like PCBs in major part of contaminated sediment and soil samples derived from the correlative matrix. Yet the different distribution patterns of them in part of sediment samples strongly indicate that other potential sources may be exist, further researches should be done to get more information about the sources and the distributions of the PCDD/Fs and PCBs.  相似文献   

6.
Different from most previous studies with quantity-limited data, this paper presents PCDD/F content characterization in the fly ash discharged from sixteen large-scale commercial MSWIs. From the results with over hundreds of data using periodically sampling and analysis, it was found that the PCDD/F contents in the fly ash were from 9.07 to 46.68 ng/g, d.w., and if based on international toxicity equivalent quantity, they were from 0.78 to 2.86 ng I-TEQ/g, d.w. The higher chlorinated PCDDs likely dominated more than lower chlorinated PCDDs, but this tendency was not for PCDFs. The OCDD had the highest contribution to the total PCDD/F content, but if based on I-TEQ content, 2,3,4,7,8-PeCDF is the PCDD/F congener with the highest toxicity contribution. Moreover, the PCDD/F characteristic index (DCI) is suggested using the representative congener content of 2,3,4,7,8-PeCDF to characterize the fly ash. The DCI is 0.875 ± 7.6% for the fly ash discharged from the MSWI with the APCD assembly of SD, AC and BF. The findings obtained in this work provide overview information on the PCDD/F content characterization in fly ash. They will provide PCDD/F fingerprint information to distinguish from other PCDD/F sources, like steel refinery industry, hazardous waste incinerators, or cement kilns, and thus be applied to fly ash management in the environment.  相似文献   

7.
Hair samples collected from e-waste recycling workers (n=23 males, n=4 females) were analyzed to assess occupational exposures to polybrominated diphenyl ethers (PBDEs) and polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) at a large e-waste recycling facility in Taizhou, eastern China. Hair samples from a reference population composed of residents of Shanghai (n=11) were analyzed for comparison. The mean concentration of ∑PBDEs (range, 22.8-1020 ng/g dw; mean, 157 ng/g dw) found in hair samples from e-waste recycling workers was approximately 3 times higher than the mean determined for the reference samples. The congener profiles of PBDEs in hair from e-waste recycling workers were dominated by BDE 209, whereas the profiles in the reference-population samples showed comparable levels of BDE 47 and BDE 209. Total PCDD/F concentrations in hair from e-waste workers (range, 126-5820 pg/g dw; mean, 1670 pg/g dw) were approximately 18-fold greater than the concentrations measured in hair from the reference population. Concentrations of PCDFs were greater than concentrations of PCDDs, in all of the hair samples analyzed (samples from e-waste and non-e-waste sites). Tetrachlorodibenzofurans (TCDFs) were the major homologues in hair samples. Overall, e-waste recycling workers had elevated concentrations of both PBDEs and PCDD/Fs, indicating that they are exposed to high levels of multiple persistent organic pollutants.  相似文献   

8.
In this study, a dual bag filter system was established to decrease the concentration of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in the stack flue gases of a fly ash treatment plant, which retained zinc from the fly ash of electric arc furnaces. Compared to the original single bag filter system with activated carbon injection (ACI) of 40 kg h(-1), the PCDD/F concentrations in the stack flue gas after the plant was equipped with the dual bag filter system dropped enormously from 3.38-7.73 ng I-TEQNm(-3) to 0.03 ng I-TEQNm(-3), and the total PCDD/F I-TEQ removal efficiency increased from 97.6% to 99.3% with ACI of 16 kg h(-1), that is, about 40% of the original AC usage. The AC utilization efficiency (0.560 mg I-TEQ absorbed kg ACI(-1)) of the dual bag filter system (AC: 16 kg h(-1)) was estimated about three times higher than that (0.192 mg I-TEQ absorbed kg ACI(-1)) of single bag filter system with ACI (40 kg h(-1)). The reason is that the particulate phase PCDD/Fs and some gas phase PCDD/Fs (captured by the recycled AC/ash mixture) were removed first by the first bag filter, and the rest of the gas phase PCDD/Fs were able to be adsorbed more completely by the AC/ash mixture due to a lower fly ash load, and then were removed by the second bag filter.  相似文献   

9.
The concentrations of 17PCDD/F congeners as well as tetra- to octa-homologues were determined in 33 soil samples collected within a radius of 7 km from a municipal solid waste (MSW) incineration plant that is equipped with three fluidized bed incinerators (FBIs) of co-firing MSW with coal in Hangzhou, China. The total PCDD/F concentrations ranged from 0.39 to 5.04 pg I-TEQ g(-1) (54-285 pg g(-1)), with an average and a median value of 1.22 and 0.84 pg I-TEQ g(-1) (105 and 86 pg g(-1)), respectively. A systematic decrease of PCDD/F levels was observed with the increasing distances and with the decreasing downwind frequencies from the plant. The comparisons of homologue and congener patterns and multivariate analysis of soil and flue gas samples strongly indicated that most of the soil samples were influenced by the FBIs. Apart from the incineration plant, historical PCDD/F emissions of hazardous waste incinerator (HWI) and motor vehicles as well as the application of 1,3,5-trichloro-2-(4-nitrophenoxy) benzene (CNP) seemed to play an important role in soil samples adjacent to these potential sources.  相似文献   

10.
This study employed direct photolysis to treat mixed polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) solutions. The solutions included a synthetic standard 17 2, 3, 7, 8-substituted congeners solution and a practical liquid extracted from the bag filter ash of an electric arc furnace. Additionally, this work utilized a coupled catalyst (ZnO/SnO2) under UV irradiation for photocatalytic degradation of 1, 2, 3, 6, 7, 8-HxCDD and OCDD. The direct photolysis rate of PCDFs was faster than that of PCDDs. The degradation rate of international toxicity equivalency quantity (I-TEQ) for PCDDs and PCDFs in the synthetic standard solution was 1.369 and 1.472 h(-1), respectively, and that in the ash-extracted solution was 0.061 and 0.117 h(-1), respectively. The rate of photocatalytic degradation declined as the number of chlorine atoms increased. No 2, 3, 7, 8-substituted congeners were identified during photocatalytic degradation; additionally, the photolytic rate of the UV/coupled catalyst was higher than that of UV/single catalyst system. Experimental results suggested that the primary degradation pathway for direct photolysis and photocatalysis of PCDD/Fs was the CCl cleavage and CO cleavage, respectively.  相似文献   

11.
The gasification behavior of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in fly ash by thermal treatment has been investigated to estimate gas-particle partition in flue gas. The results obtained in thermal experiments under various conditions showed that gasification of PCDD/Fs depends on air flow rate and treatment weight of fly ash as well as treatment temperature. On the other hand, the results obtained in the thermal experiments using dioxin-free fly ash revealed that during thermal treatment, the de novo synthesis, gasification, and decomposition of PCDFs proceeded at different rates. This difference in the reaction rates indicates that thermal treatment time is also a factor in determining the gas-particle partition of PCDD/Fs in fly ash. Therefore, reasonable thermal treatment conditions were established and applied to three ash samples. For all samples, PCDD/Fs started to gasify at 350 degrees C treatment, whereas 53-98% of PCDD/F homologs gasified at 400 degrees C treatment, implying that gaseous PCDD/Fs are dominant in flue gas at temperatures in the range 350-400 degrees C regardless of particle concentration.  相似文献   

12.
Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) levels in a total of 25 food items in Taiwan were surveyed. It was observed that shellfish and saltwater fish possessed the highest PCDD/Fs levels, 9.82 and 3.60 pg WHO-TEQ/g, respectively, on the lipid basis. The dietary intakes of humans at the ages of 12-18, 19-64, and over 65 were determined. The estimated intake were between 21.8 pg (female teenagers) and 37.6 pg (male seniors) WHO-TEQ/day; the levels varied with the dietary habits. The PCDD/F intakes for all human groups are far below the tolerable limit of 70 pg WHO-TEQ/kg b.w./month. In addition, the daily PCDD/F intake levels for duck-farmers consuming average and large amounts of PCDD/F contaminated duck eggs were examined. The result shows that consuming more than one duck egg with level higher than 10 pg WHO-TEQ/g lipid of PCDD/Fs per day could lead to a PCDD/F intake level higher than the tolerable limit. However, for normal population, there is a little risk to ingest intolerable amount of PCDD/Fs because of consuming contaminated duck eggs.  相似文献   

13.
We measured the concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from the flue gas and the ambient atmosphere of a power plant fueled by heavy oil in northern Taiwan. The mean emission concentration and I-TEQ concentration of total PCDD/Fs were 0.292 ng/Nm(3) and 0.016 ng I-TEQ/Nm(3), respectively. All PCDD/F emission concentrations in the flue gas were supposed to meet the Environmental Protection Administration Executive Yuan, R.O.C. standard (1.0 ng I-TEQ/Nm(3) from 2008). Furthermore, the mean I-TEQ concentration in the ambient atmosphere was 0.011 pg I-TEQ/Nm(3), which was much lower than the environmental quality standards for dioxins in Japan (0.6 pg TEQ/Nm(3)). Also, the PCDD/F emission factor was 0.188 ng I-TEQ/L fuel, which was comparable to the data issued in US EPA [EPA, Locating and estimating air emissions from sources of dioxins and furans, Office of Air Quality Planning and Standards, Research Triangle Park, NC, DCN No. 95-298130-54-01, 1997] (0.2 ng I-TEQ/L of fuel). Also, the result of the correlations of PCDD/Fs and operational parameters illustrated that the positively significant correlation (r=0.502, p=0.048) was found only between PCDD/Fs (I-TEQ) and the flue gas emission temperature (125-157 degrees C). However, PCDD-TEQ/PCDF-TEQ ratios were statistically significantly associated with the decreased flue gas flow (r=-0.659, p=0.006), moisture (r=-0.612, p=0.012) and flue gas temperature (r=-0.503, p=0.047). For proper environmental management of dioxins, it is necessary to establish a complete emission inventory of PCDD/Fs, and, in particular, the government should pay more attention to power plants to address the information shortage.  相似文献   

14.
Surface water from Guangzhou to which standard polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were added was treated by coagulation with ferric chloride (FC), polyaluminium chloride (PAC), and aluminium sulfate (AS) at optimum removal dosages for nature organic matter (NOM) to assess the polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) removal efficiencies. PCDD/Fs in suspended particulate matter (SPM) and treated water (TW) after coagulation were analysed. Low residual levels of PCDD/Fs were found in treated water after coagulation: 0.8% for FC, 0.9% for PAC, and 3.1% for AS. The removal efficiency calculated using these results was >99% for FC and PAC and 97-98% for AS. Most PCDD/Fs congeners could be removed by the three coagulation processes; the removal efficiency of FC and PAC was similar, and slightly higher than that of AS. The results also demonstrate that coagulation with FC preferentially removed tetra- and penta-substituted PCDD/Fs from raw water.  相似文献   

15.
This study determined the polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs) contents in ash in the super heater (SH), economizer (EC), semi-dryer absorber (SDA), fabric filter (FF), fly ash pit (FAP) and bottom residue (BR) in a municipal solid waste incinerator (MSWI). A high-resolution gas chromatograph/high-resolution mass spectrometer (HRGC/HRMS) was utilized for analyzing 17 PCDD/F species. Experimental results showed that average PCDD/F contents in ash samples from the SH, EC, SDA, FF, FAP and BR were 0.102, 0.788, 0.210, 1.95, 2.04 and 0.0218 ng I-TEQ g(-1), respectively. PCDD/F content was very low in the SH and BR due to high temperatures (around 461 degrees C in the SH and 914 degrees C in combustion chamber). Conversely, total PCDD/F content was significantly high in ash samples from the EC (around 340 degrees C), mainly because the temperature is within the favorable range of 250-400 degrees C for PCDD/F formation due to de nova reformation mechanisms. Although the SDA operated at 245 degrees C, the PCDD/F content decreased very significantly, mainly because the temperature was relatively low and because calcium carbonate was introduced into flue gases to dechlorinate and dilute chlorine-containing species. PCDD/Fs were captured by the active carbon in the FF. Furthermore, the duration that fly ash remained in the FF was longer than that for other incinerator units, and thus causing an increasing trend of PCDD/Fs level downstream (except the SDA). Total PCDD/Fs emission factors (microg tonnes-waste(-1); microg I-TEQ tonnes-waste(-1)) in ash samples from different units were: SH (42.3; 0.846), EC (326; 6.12), SDA (58.1; 1.10), FF (1540; 61.3), FAP (2950; 107) and BR (537; 4.31). Most PCDD/Fs in ash were contributed by the FF (about 56%), and the generation of PCDD/Fs in ash was significant (about 35%) during the transfer process from different units to the FAP. A strong and positive correlation in a logarithmic form existed between PCDD/Fs and chlorine (Cl(-1)) contents in ash. In Taiwan, the government policy for incineration residues advocates their reuse as road sub-bases or secondary building materials provided that total PCDD/Fs content is below the legal limit (1 ng I-TEQ g(-1)). Thus, ash with total PCDD/Fs content below the legal limit, such as that from the SH, EC, SDA and BR, can be collected and transferred to the FAP and reused. Ash with total PCDD/Fs content exceeding the legal limit, such as that from the FF, should be collected separately and be treated properly before being disposal in a landfill.  相似文献   

16.
For an accurate determination of the gas-particle partition of polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs) and dioxin-like biphenyls (DLPCBs) in dust-rich flue gas, a parallel monitoring procedure with an isokinetic and a non-isokinetic train was used. For four flue gas samples, the two trains gave a significantly different weight of the collected fly ash particles despite the equal gas volume sampled. On the basis of the quantitative values of PCDD/F and DLPCB homologues and the weight of the collected particles, ratios of each homologue in the real flue gas samples in gaseous form were predicted using simultaneous equations. For the four flue gas samples examined, the predicted gaseous ratios were considerably higher that those calculated using a previously reported equation, suggesting that there are some properties which affect partitions of PCDD/Fs in flue gas besides their saturation vapor pressures and fly ash concentration. The partitions for higher temperature flue gases obtained by fractional determinations of each collection device were additionally different from those predicted by the parallel collection, indicating that conventional determination by fractional measurements is subjected to large errors in dust-rich flue gas due to severe adsorption of gaseous PCDD/Fs and DLPCBs onto particles collected on a low-temperature collection device.  相似文献   

17.
The levels and homologue profile of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from stack gas of three typical fluidized bed incinerators co-firing municipal solid waste (MSW) with Chinese coal were measured. The PCDD/Fs emission was in the range of 0.0054-0.1961 ng I-TEQ/N m(3). Comparison of PCDD/Fs detection results by HRGC/HRMS and HRGC/LRMS suggested that it was feasible to detect fly ash with high PCDD/Fs concentration by HRGC/LRMS. Several factors on PCDD/Fs emission were discussed. The primary reason for the lower PCDD/Fs emission was the inhibition mechanism of relatively high sulfur in feeding coal on PCDD/Fs formation. The emission results also showed that there was no directly correlation between PCDD/Fs levels and CO, O(2) and HCl concentration in flue gas. It was estimated that about 0.1034 g I-TEQ was annually emitted to atmosphere from the tested three MSW incinerators (total daily treatment capacity is 800 tonnes MSW).  相似文献   

18.
The contamination status of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (DL-PCBs) was preliminarily investigated in surface sediments collected from the East River during April 2007. The contamination levels of PCDD/Fs and DL-PCBs ranged from 2.1 to 9.8 with mean concentration of 4.5 pg WHO98-TEQ g−1 and ranged from 0.042 to 0.45 with mean concentration of 0.19 pg WHO98-TEQ g−1, respectively. All sediments were characterized by the elevated levels of PCDDs, especially OCDD. Higher concentrations of PCDD/Fs were found in the sediments from Guangzhou and Dongguan. Source analysis revealed that PCDD/Fs in the sediments from Guangzhou were mainly from the secondary copper smelters and steel-making plants, and PCDD/Fs in the sediment from Dongguan were mainly from MSWIs. PCP and paper mills were unlikely to be the main sources.  相似文献   

19.
Although many researches focused on the polychlorinated dibenzo-p-dioxins/dibenzofuran (PCDD/F) emissions from stack, in the bottom ash and in the surrounding environment, researches focused on PCDD/F mass distributions in the whole incineration plant have seldom been addressed. This study determined PCDD/F emissions in the whole plant. A high-resolution gas chromatograph/high-resolution mass spectrometer was utilized for analyzing 17 PCDD/F species. Experimental results displayed that PCDD/Fs were formed during fly ash from super heater (SH), economizer (EC), semi-dryer absorber (SDA) and fabric filter (FF) was transferred to fly ash pit. Mass distribution ratios of PCDD/Fs in g I-TEQ (Toxicity Equivalency Quantity) per week from stack, SH, EC, SDA, FF, generation and bottom residue (BR) in start-up operations were 14.6%, 0.1%, 8.3%, 1.0%, 41.7%, 33.4% and 0.9%, respectively. Above results indicated that main PCDD/F source in the MSWI was from fly ash. However, the fly ash is easily controlled and PCDD/F emitted from stack flue gases will be difficult to be handled. Therefore, we should pay more attention on PCDD/F emission from flue gases especially from start-up procedure. Besides, fly ash should be controlled by sodium hypophosphite before being landfilled. MSWI did require further detoxification treatments for the solid residues and flue gases.  相似文献   

20.
Emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from an industrial park operated as Taiwan's center of metallurgical industries were investigated. The characteristics of mean PCDD/F I-TEQ concentrations, congener profiles and emission factors of each source were studied over samples of stack flue gases of individual sources. Different characteristics of congener profiles and large variations of emission factors of secondary aluminum smelters (ALSs) were observed. The mean emission factors of electric arc furnaces were comparable to those for ALSs and much greater than those of municipal solid waste incinerators and sinter plants, but still less than that of clinical waste incinerators. Annual PCDD/F emission contribution of each source was estimated, raising critical concerns over the overall PCDD/F emissions from metallurgical processes. The metallurgical industries altogether contributed approximately 98.1% of the total annual emissions, while waste incinerators only 1.9%. The contributions by sinter plants and metallurgical industries to the total annual emissions of the Park were much higher than the corresponding national averages of Taiwan. The combined dioxin emissions from the entire metallurgical processes and their controls should be seriously envisaged by industrial parks devoted to metal productions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号