首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper investigates the structural performance of vertically distributed multiple tuned mass dampers (MTMDs), which can save valuable occupiable space near the top of tall buildings, control the first as well as higher mode responses and be installed more easily because of smaller tuned mass damper (TMD) masses. Vertically distributed MTMD theory is presented. With this theory, the effectiveness of vertically distributed MTMDs along the building height is predicted using simplified models, compared with the conventional TMDs installed near the top of tall buildings. Vertically distributed MTMDs are designed for a typical 60‐storey tall building subjected to representative dynamic wind loads, and their performance is measured. The results of these studies show that TMDs can be distributed vertically along the building height without substantial loss of their effectiveness. Considering their advantages over the conventional system, vertically distributed MTMDs possess a high potential of practical applications for tall‐building motion control. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
3.
The wind‐induced vibrations of super tall buildings become excessive due to strong wind loads, super building height and high flexibility. Tuned mass dampers (TMDs) and tuned liquid column dampers (TLCDs) have been widely used to control vibrations for actual super tall buildings for decades. To fully use both the economic advantage of the TLCD system and the high efficiency of the TMD system, an innovative supplemental damping system including both TLCD and TMD and called combined tuned damper (CTD), which can substantially decrease the cost of the damper, was proposed to control the wind‐induced vibrations of tall buildings. The governing equations are generated for the motion of both the primary structure and the CTD and solved to anticipate the dynamic response of the CTD‐structure system. Moreover, an optimal design method of human comfort performance is proposed, in which the life cycle cost of the damper‐structure system is considered as the quantitative index of the performance. The life cycle cost includes the initial cost, the maintenance cost and the failure cost. The failure cost can be calculated using the vibration‐sensation rate model, which is based on the Japanese code AIJES‐V001‐2004. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

4.
The most common device for control of tall buildings under wind loads is the tuned mass damper (TMD). However, during their lifetimes, high‐rise and slender buildings may experience natural frequency changes under wind speed, ambient temperatures and relative humidity variations, among other factors, which make the TMD design challenging. In this paper, a proposed approach for the design of robust TMDs is presented and investigated. The approach accounts for structural uncertainties, optimization objectives and input excitation (wind or earthquake). For the use of TMDs in buildings, practical design parameters can be different from the optimum ones. Nevertheless, predetermined optimal parameters for a primary structure with uncertainties are useful to attain design robustness. To illustrate the applicability of the proposed approach, an example of a very slender building with uncertain natural frequencies is presented. The building represents a case study of an engineered design that is instructive. Basically, due to its geometry, the building behaves differently in one lateral direction (cantilever building) than the other (shear building). The proposed approach shows its robustness and effectiveness in reducing the response of tall buildings under multidirectional wind loads. In addition, linear‐quadratic Gaussian and fuzzy logic controllers enhanced the performance of the TMD. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
An integrated optimal structural design method for a diagrid structure and control device was developed. A multi-objective genetic algorithm was used and a 60-story diagrid building structure was developed as an example structure. Artificial wind and earthquake loads were generated to assess the wind-induced and seismic responses. A smart tuned mass damper (TMD) was used as a structural control system and an MR (magnetorheological) damper was employed to develop a smart TMD (STMD). The multi-objective genetic algorithm used five objectives including a reduction of the dynamic responses, additional stiffness and damping, mass of STMD, capacity of the MR damper for the integrated optimization of a diagrid structure and a STMD. From the proposed method, integrated optimal designs for the diagrid structure and STMD were obtained. The numerical simulation also showed that the STMD provided good control performance for reducing the wind-induced and seismic responses of a tall diagrid building structure.  相似文献   

6.
Pendulum tuned mass damper (PTMD) is usually used to control the horizontal vibration of a tall building. However, traditional PTMD is highly sensitive to frequency deviation and difficult to adjust its frequency. In order to improve this problem of traditional PTMD and protect a tall building more effectively, a novel PTMD, called self‐adjustable variable pendulum tuned mass damper (SAVP‐TMD), is proposed in this paper. On the basis of the acceleration ratio between TMD and primary structure, the SAVP‐TMD can retune itself by varying the length of the pendulum according to the improved acceleration ratio‐based adjustment algorithm. PTMD and primary structural accelerations are obtained from two accelerometers respectively, and the acceleration ratio is calculated in a microcontroller, then, the stepper motor will adjust the pendulum under the guidance of the microcontroller under a specific harmonic excitation. The improved acceleration ratio‐based adjustment algorithm is proposed and compared to solve the nonconvergent retuning problem. The SAVP‐TMD can be regarded as a passive damper including a frequency adjustment device. A single‐degree‐of‐freedom structure model is used to verify the effectiveness of SAVP‐TMD through both experimental study and numerical simulation. In order to further verify the effect of SAVP‐TMD in the MDOF structure, a five‐storey structure coupled with an SAVP‐TMD is proposed as a case study. The results of experiment, simulation, and case study all show that SAVP‐TMD can retune itself to the primary structural dominant frequency robustly, and the retuned PTMD has a better vibration control effect than the mistuned one.  相似文献   

7.
A particle tuned mass damper system is an integration of tuned mass damper and particle damper. The damping performance of such device is investigated by an aero‐elastic wind tunnel test on a benchmark high‐rise building. The robustness of the system is studied by comparing the damping performance to that of a traditional tuned mass damper, and the results show that the damper has excellent and steady wind‐induced vibration control effects. Meanwhile, the parameters (filling ratio, mass ratio, and mass ratio of the container to particles), which have great influence on the vibration reduction performance of the system, are also analyzed, and it is found that the particles filling ratio plays the most important role in deciding the damping effects of the dampers. There exists an optimum filling ratio and mass ratios in which the damper can reach the best damping state. Proper parameter selections can greatly improve the damping performance.  相似文献   

8.
Active tuned mass dampers (ATMDs) are one of the most effective solutions for mitigation of destructive effects of earthquakes and strong winds in tall buildings. In order to achieve optimal performance, these systems are designed and tuned to mitigate effect of either wind or earthquake excitation. However, due to different frequency contents and intensities of wind and earthquake excitations, which will cause contrasting structural modes stimulation, the ATMD designed for one of these disturbances may not work optimally for the other one. This paper addresses a methodological simulation approach for adaptive control design of ATMDs in tall buildings located in regions with high level of seismic activity and recurrent strong winds. For this purpose, a multi‐objective adaptive genetic‐fuzzy controller is proposed for the control of an ATMD of a benchmark 76‐story building subjected to wind load and earthquake disturbances. Simulation results reveal that the optimal ATMD designed for earthquake disturbance does not work adequately for wind load disturbance and vice versa. Furthermore, the proposed adaptive controller has superior performance in suppressing base shear and inter‐story drifts induced by wind load and earthquake excitations. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
This study presents an advanced experimental system, hardware‐in‐the‐loop (HIL), recently referred to as hybrid testing, to validate the effectiveness of a double‐decker tuned sloshing damper (TSD) system with screens applied to a recently constructed tall building. The HIL simulation facilitates a performance analysis of a combined structure‐damper system in which the nonlinear behavior of liquid motion in a TSD is physically modeled, whereas a building system under wind loads that behaves linearly is embedded virtually utilizing a computer model. The scaled model of the TSD is composed of a computer‐controlled system with a shaking table, sensors, and a real‐time communication link. The virtual building system on the computer communicates in real time with the hardware, that is, the physical model of TSD to evaluate on‐the‐fly the performance of a combined building‐TSD system. External excitation including random loading characteristics of winds, waves, or earthquakes can be implemented in HIL to observe the dynamics of the building‐damper system under a host of loading scenarios. An example of a recently completed tall reinforced concrete building with multiple TSDs placed side by side in double‐decker configuration under a suite of external loads and the proposed damping estimation procedure to evaluate the amount of auxiliary damping with TSD for ensuring the TSD design is presented. It examines the habitability of the building in winds and evaluates the effectiveness of the TSD system as well as the efficacy of the first HIL simulation for an actual tall building‐TSD system equipped with screens inside.  相似文献   

10.
通过数值模拟研究了地震作用下高层结构多个调谐质量阻尼器(MTMD)减震控制。根据实际工程,利用国际通用软件ETABS建立了结构三维有限元模型,进行了动力特性的分析,得到了结构的前几阶频率;根据不同场地类型,选取了4条典型的地震波;研究了调谐质量阻尼器(TMD)的参数选取和有限元的模拟;运用时程分析方法,分别研究了不同地震作用下高层结构有无控制下的反应。研究结果表明,MTMD对高层结构的减震控制效果明显,场地类型对减震控制效果有一定的影响。所获得的结果为高层结构减震控制设计提供参考和依据。  相似文献   

11.
As today's tall buildings become ever taller and more slender, wind‐induced vibration is a serious design issue. This paper presents integrated damping systems for tall buildings. An emphasis is placed on investigating the potential of double skin facades (DSF) as an integrated damping system for tall buildings. In the first scheme, the connectors between the inner and outer skins of the DSF system are designed to have low axial stiffness with a damping mechanism. Through this design, vibration of the primary building structure can be substantially reduced. However, excessive movements of the DSF outer skin masses are a design limitation. In the second scheme, the tuned mass damper (TMD) and DSF damping (DSFD) interaction system is studied to mitigate the design limitation of the first scheme and to resolve other TMD‐related design issues. TMDs are usually very large and located near the top of tall buildings for their effective performance. As a result, very valuable occupiable space near the top of tall buildings is sacrificed to contain large TMDs. In addition, installing TMD systems means adding additional masses to tall buildings. Through the TMD/DSFD interaction system, these issues can also be substantially addressed. Compared with the conventional TMD system, the TMD/DSFD interaction system requires a significantly reduced TMD mass ratio to achieve the same target damping ratio. Compared with the first scheme only with the DSFD mechanism, movements of the DSF outer skins can be better controlled in the TMD/DSFD interaction system. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

12.
西安某科研楼顶钢结构塔楼风振控制的研究   总被引:2,自引:0,他引:2  
以西安长庆石油勘探局科研楼钢结构塔楼工程为背景 ,建立了高楼屋顶上钢结构塔楼的三维空间有限元静力模型和二维串联多自由度的动力模型。讨论了高楼上高塔的振动特性以及安装粘滞性阻尼器对屋顶钢塔风响应的振动控制。研究表明 ,安装粘滞阻尼器可以有效地控制高塔在大风下的动力响应  相似文献   

13.
结合GB 50009-2012《建筑结构荷载规范》中的等效静风荷载计算方法,研究设置主被动可切换的混合调谐质量阻尼器(TMD/ATMD)的规则高层建筑结构的风振分析与实用设计方法。将控制系统的风振控制效果按照风振响应方差相等的原则归结为对受控结构的附加等效阻尼比,推导了控制系统最优参数和附加等效阻尼比的计算公式,给出了惯性质量平均最大行程比、主动控制力和额定功率的简化计算方法;并讨论了主动/被动控制模式的切换准则。最后给出以风振控制Benchmark结构模型为对象的受控结构及混合调谐质量阻尼系统的设计算例。算例分析表明:建议的设计方法可以方便地进行受控结构响应分析和控制系统参数设计;混合调谐质量阻尼器可以有效减小设计等效静风荷载和结构的动力响应。  相似文献   

14.
随着高层以及超高层建筑结构不断向更高和更柔的方向发展,强风作用下这类建筑的传统设计方法有时已经无法完全满足结构的抗风设计要求。因此,提出了采用振动控制来抑制结构风致振动控制的新方法。论文首先概述了高层建筑中风振控制的方法及其国内外的研究现状,然后对其中的调谐质量阻尼器(TMD)、主动调谐质量阻尼器(ATMD),以及摩擦阻尼器这3种控制方法详加评述,最后进一步指出我国风振控制研究的发展方向。  相似文献   

15.
A novel semi‐active control algorithm is developed and numerically evaluated for the suppression of undesirable structural vibrations. The mechanical energy of the vibrating structure is considered as the primary variable influencing the control action. This intuitive strategy is proposed to realize improved control of structural vibrations. The numerical study conducted reveals that the proposed energy‐based predictive (EBP) algorithm can be implemented on vibration control applications. The energy imparted to the structure is also reduced due to the proposed algorithm. The influence of the parameters of the proposed semi‐active tuned mass damper is studied. Further, the application of the proposed strategy on a realistic structure is numerically demonstrated by implementing the algorithm for the wind response control of a 76‐story benchmark building. The results show that the EBP algorithm is a competitive semi‐active strategy. The robustness of the strategy is also evaluated considering uncertainties in the properties of the benchmark building.  相似文献   

16.
Abstract: The typhoon behavior and performance of a tuned mass damper (TMD) are presented based on the system identification and the inverse modal wind load estimation. The TMD was installed on a 39‐story, 184.6‐m steel building located in Incheon, Korea with a monitoring system consisting of an anemometer, accelerometers, and internet‐based data logging system. On September 2, 2010, the building experienced the Kompasu Typhoon, in which the peak wind speed, measured by an anemometer installed on the roof floor, was 49.7 m/s. To analyze the behavior of the building during the typhoon, the dynamic properties of building and TMD are identified from the measured responses. The modal wind load is then inversely estimated from the TMD and building accelerations using a Kalman filter, and the vibration reduction performance of the TMD is evaluated. The analysis results show that the typhoon‐induced vibration was reduced significantly due to the installation of TMD.  相似文献   

17.
To evaluate different energy dissipation systems used to control wind-induced vibrations of a 456 m super-tall building in fluctuating wind excitations, the finite element (FE) method was employed to simulate the dynamic responses of the building. A series of wind tunnel pressure tests were conducted on a 1:450 scale model to determine the wind forces acting on the super-tall building. A FE model was also constructed and mass, damping and stiffness matrices were subsequently formulated as an evaluation model for numerical analysis. The evaluation model was further simplified to a state reduced-order system using the state order reduction method. Three different vibration control schemes, namely a tuned mass damper (TMD) system, a system containing only nonlinear viscous dampers and a hybrid control system combining TMD and viscous dampers, were examined through simulations with respect to their effectiveness in reducing the accelerations at the top of the building. Furthermore, a cost evaluation was conducted to determine the most economical structural design and vibration control scheme. The results show that the wind-induced vibrations of the analysed building can be controlled effectively by all the three examined schemes, while the hybrid control scheme and the scheme containing only viscous dampers further reduce the wind-induced vibration to satisfy a more stringent criterion for a six-star hotel. In addition, the hybrid vibration control scheme is also the most cost-effective among the examined schemes.  相似文献   

18.
本文提出了设置粘弹性阻尼器的钢结构高层建筑抗震抗风设计的实用方法。文中在导出了设置粘弹性阻尼器高层钢结构的有效阻尼比计算公式的基础上,建立了设置粘弹性阻尼器结构抗震设计反应谱的调整公式和抗风设计风振系数、脉动增大系数的调整公式。从而使设置粘弹性阻尼器钢结构高层建筑的抗震抗风设计可在我国《高层民阻建筑钢结构设计与施工》规程的基础上进行。应用本文方法对设置粘弹性阻尼器的50层全钢缔构超高层建筑──首都规划大厦主楼的抗震抗风设计的结果表明:粘弹性阻尼器是一种十分有效的减振耗能构件,它有效地减小了结构构件的地震设计内力和结构横风向的风振加速度。对于设置粘弹性阻尼器的高层钢结构,本文提出的抗震抗风设计方法是一种对结构工程师应用十分方便的实用设计方法。  相似文献   

19.
费翔  符川 《建筑技术开发》2011,(9):22-23,77
调频气压液柱阻尼器(TLCGD)是一种从调频液柱阻尼器发展而来的新型而有效的结构减震装置。在U/V形阻尼器液柱上加上封闭式气压不仅增加了它的使用范围,使频率扩大到5Hz,并且提高了结构的有效阻尼。通过该装置在高层建筑和桥梁上的运用,U/V形调频气压液柱阻尼器能有效地控制水平为主的结构动力反应,而扭转调频气压液柱阻尼器(torsional tuned liquid column gas damper,TTLCGD)是一种能控制结构扭转为主的阻尼器。  相似文献   

20.
高层建筑几种风振控制方式的设计方法   总被引:2,自引:0,他引:2       下载免费PDF全文
本文提出了高层建筑三种风振控制方式(拉索,挡风板和可调质量阻尼器)的一个改进的设计方法。文中:建立了脉动风的成型滤波器,导得了基于结构层间位移、速度和加速度反应的扩展二次型目标函数的控制规律,实现了高层建筑强度,刚度和舒适度的控制要求,提出了消极控制的具体设计方法,采用了一种简单而实用的自适应控制方法,使主动控制得到实现。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号