首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A generalized dimensionless formulation has been developed to predict the spatial distribution of microwave power and temperature. The ‘dimensionless analysis’ is mainly based on three numbers: wave number, ; free space wave number, ; and penetration number, , where is the ratio of sample thickness to wavelength of microwaves within a material, is based on wavelength within free space and is the ratio of sample thickness to penetration depth. The material dielectric properties and sample thicknesses form the basis of these dimensionless numbers. The volumetric heat source due to microwaves can be expressed as a combination of dimensionless numbers and electric field distributions. The spatial distributions of microwave power for uniform plane waves can be obtained from the combination of transmitted and reflected waves within a material. Microwave heating characteristics are obtained by solving energy balance equations where the dimensionless temperature is scaled with respect to incident microwave intensity. The generalized trends of microwave power absorption are illustrated via average power plots as a function of , and . The average power contours exhibit oscillatory behavior with corresponding to smaller for smaller values of . The spatial distributions of dimensionless electric fields and power are obtained for various and . The spatial resonance or maxima on microwave power is represented by zero phase difference between transmitted and reflected waves. It is observed that the number of spatial resonances increases with for smaller regimes whereas the spatial power follows the exponential decay law for higher regimes irrespective of and . These trends are observed for samples incident with microwaves at one face and both the faces. The heating characteristics are shown for various materials and generalized heating patterns are shown as functions of , and . The generalized heating characteristics involve either spatial temperature distributions or uniform temperature profiles based on both thermal parameters and dimensionless numbers ().  相似文献   

2.
The effects of temperature on the kinetics of anaerobic sulphate reduction were studied in continuous bioreactors using acetate as an electron donor. Across the range of temperatures applied from 20 to , the increasing of volumetric loading rate up to 0.08 to resulted in a linear increase in reduction rate of sulphate. The increasing reaction rate showed a lower dependence on volumetric loading rate in the range 0.1-. Further increase in volumetric loading rate above was accompanied by wash out of bacterial cells and a sharp decrease in reaction rate. Despite a similar pattern for dependency of reaction rate on volumetric loading at all temperatures tested, the magnitude of reaction rate was influenced by temperature, with a maximum rate of observed at . The effect of temperature on maximum specific growth rate (μmax) and bacterial yield was insignificant. The values of maximum specific growth rate and yield were and 0.56-0.60 kg bacteria (), respectively. The decay coefficient (kd) and apparent saturation constant () were both temperature dependent. The increase of temperature resulted in decreased values of , and higher values for kd. Using the experimental data effect of temperature was incorporated in a kinetic model previously developed for anaerobic reduction of sulphate.  相似文献   

3.
4.
5.
6.
Design and analysis of fluid flow and heat and mass transfer in engineered spaces require information of spatial scales ranging from to and time scales from to . The studies of such a multiscale problem often use multiple computer models, while each of computer models is applied to a small range of spatial and time scales. Accurate solution normally requires exchanging information between a macroscopic model and a microscopic model that can be done by coupling the two models. With the approach, it is possible to obtain an informative solution with the current computer memory and speed.This paper used a few examples of fluid flow and heat and mass transfer in engineered spaces to conclude that a coupled macroscopic and microscopic model is likely to have a solution and the solution is unique. A stable solution for the coupled model can be obtained if some criteria are met. The information transfer between the macroscopic and microscopic models is mostly two ways. A one-way assumption can be accepted when the impact from small scale on large scale is not very significant.  相似文献   

7.
8.
A particle reaction model including mass and heat transfer has been developed to know the temperature variations produced inside the oxygen carrier particles during the cyclic reduction and oxidation reactions taking place in a chemical-looping combustion (CLC) system. The reactions of the different oxygen carriers based on Cu, Co, Fe, Mn, and Ni during the reduction with fuel gas (CH4, CO, and H2) and oxidation (O2) have been considered. In these systems, the oxidation reaction is always exothermic with subsequent heat release; however, the reduction reaction can be exothermic or endothermic depending on the metal oxide and the fuel gas. The heat generated inside the oxygen carriers during the exothermic reactions increases the particle temperature, and could affect the particle structure if the temperature increase is near to the melting point of the active materials. Several variables that affect the reaction rate and the heat transport process have been analyzed to know their effect on the internal particle temperature. For a given oxygen carrier and reaction, the maximum temperature of the particles depended mainly on the particle size, the reaction rate, and the external heat transfer resistance, being lower than the effect of the oxygen carrier porosity, type of inert material, and metal oxide content. The highest temperature variations were reached for the oxidation reactions, with the maximum corresponding to the Ni and Co oxygen carriers with values of for particles. The highest temperature increase observed during the reduction reactions corresponded to the reaction of CuO with CO, with values of for particles. For the rest of the reactions and metals, the variations in the particle temperature were below for particle sizes below . Under the typical operating conditions that exist in a CLC system, with particle sizes lower than , % of metal oxide content, and overall conversion times lower than , the increases of temperature with respect to the bulk conditions were lower than for any reaction of any oxygen carrier. Moreover, the temperature profiles inside the particles were near flat in most of the practical conditions, and no local points with high temperatures were found. Thus, changes in the solid porous structure of the carrier due to sintering during oxidation in fluidized bed reactors are not expected working at typical temperatures of CLC systems (1000-).  相似文献   

9.
Bubble breakage and coalescence phenomena and multicomponent gas-liquid mass transfer were studied in a Rushton turbine agitated vessel. Local bubble size distributions (BSD) were measured from air-tap water system at several agitation conditions with capillary suction probe (CSP) technique. The CSP was compared to the digital imaging (DI) and phase Doppler anemometry (PDA) techniques in a stirred vessel. The volumetric BSDs between the CSP and DI were in agreement, but number BSDs showed notable deviation. The limitations of measurement techniques seem to be the main reason.A multiblock stirred tank model with discretized population balances for bubbles and two-film Maxwell-Stefan multicomponent mass transfer between gas and liquid was created for the agitated vessel. The model considers local mass transfer conditions in the vessel and is simple enough for the mathematical optimization of unknown model parameters. Unknown parameters in the mechanistic bubble breakage and coalescence models were fitted against measured local BSDs. After this, a parameter in the liquid film mass transfer correlation was adjusted against absorption and desorption experiments of oxygen. Local gas-liquid mass transfer areas were calculated from the population balance model. The simulations with the validated models show good agreement against experiments. On the other hand, the fitted parameters deviate from the theoretical values, which emphasizes the need of model validation against accurate experiments. Due to their fundamental character and the validation process, the fitted models seem to be useful tools for the design and scale-up of agitated gas-liquid reactors.  相似文献   

10.
11.
12.
13.
Macromixing characteristics, power number and visual observation of the vortex behaviour and micromixing in an unbaffled tank agitated with a Rushton turbine are reported. The latter has also been compared in detail with earlier results from an identical tank containing baffles. The maximum mean specific energy dissipation rate, , in the unbaffled tank that can be utilised without severe air incorporation is compared to with baffles. However, at this lower , the micromixing efficiency is always significantly greater without baffles except when addition is made onto the top of the liquid or into the trailing vortex very close to the impeller. In these latter cases, they are approximately the same but even a small submergence of the feed tube below the liquid surface greatly enhances micromixing in the unbaffled case whilst it is still very poor with baffles. This good micromixing performance of the unbaffled vessel was very unexpected. Furthermore, an established method of estimating the local εT gave values of at every feed position where measurement was undertaken. Since the spatially averaged value of φ=1, this result suggests the possibility that the accepted concept of micromixing being totally controlled by the local εT at the feed point may not be valid for such swirling flows.  相似文献   

14.
15.
16.
Treatment of wastewater containing high organic matter was investigated by means of a jet loop bioreactor combined with a membrane process. Volume of jet loop bioreactor and area of membrane filtration unit were 23 l and 155 cm2 respectively. It was found that jet loop reactor had high mass transfer coefficient (KLa) varying from 58.8 to 486 h-1 depending on the water flow rate (i.e. power input) and air flow rate. Oxygen transfer efficiency and oxygenation capacity of the reactor varied from 12 to 22.5% and from 0.2 to 1.8 , respectively. The efficiency of jet loop membrane bioreactor was found to be approximately 97% for a volumetric organic load of 2- over a period of 10 weeks. The reactor was not disturbed from the organic loads up to , but the treatment efficiency decreased to about 60% at higher organic loads. This decrease was due to insufficient oxygen transfer rate. The relationship between the effluent substrate concentration and the specific oxygen uptake rate (SOUR) values was determined. Applied food/microorganism (F/M) ratio was varied between 2.5 and . Critical sludge age of the system () was evaluated to be 7.2 h. Sludge with unsatisfactory settling characteristics formed at high F/M values under turbulent conditions. Therefore, membrane process was used for solid-liquid separation and effluent solid concentration was approximately zero. Specific cake resistances (α) changed with F/M ratio. It was found that permeate fluxes were significantly effected with F/M ratio much more than mixed liquor suspended solids (MLSS). Average flux was for pore sized cellulose acetate membrane. It was concluded that the jet loop membrane bioreactor has distinctive advantages such as the ability to treat high strength wastewater, low area requirements and easy operation.  相似文献   

17.
18.
Based on airlift configuration, a novel circulating jet-loop submerged membrane bioreactor (JLMBR) adapted to ammonium partial oxidation has been developed. Membrane technology and combined air and water forced circulation are adopted to obtain a high biomass retention time and to achieve a separate control of mixing and aeration. This study is intended to determine how gas-liquid mass transfer is affected by operating conditions. In a first approximation, liquid was assumed to be perfectly mixed. A classical non-steady state clean water test, known as the “gas out-gas in” method, was used to determine the gas-liquid mass transfer coefficient kLa. Air and recirculated liquid superficial velocities were gradually increased from 0.013 to and 0.0056 to , respectively. Subsequently, the gas-liquid mass transfer coefficient kLa varied from 0.01 to . It appears to be influenced by the combined action of air and recirculated liquid flowrates in the range and , respectively, for air and liquid. Correlations are proposed to describe this double influence. Experiments were performed on tap water and a culture medium used for the autotrophic growth of nitrifying bacteria, respectively. Oxygen transfer appeared to be not significantly affected by the mineral salt encountered in this medium.  相似文献   

19.
Many commercial processes for the removal of carbon dioxide from high-pressure gases use aqueous potassium carbonate systems promoted by secondary amines. This paper presents thermodynamic and kinetic data for aqueous potassium carbonate promoted by piperazine. Research has been performed at typical absorber conditions for the removal of CO2 from flue gas.Piperazine, used as an additive in 20- potassium carbonate, was investigated in a wetted-wall column using a concentration of at 40-80°C. The addition of piperazine to a potassium carbonate system decreases the CO2 equilibrium partial pressure by approximately 85% at intermediate CO2 loading. The distribution of piperazine species in the solution was determined by proton NMR. Using the speciation data and relevant equilibrium constants, a model was developed to predict system speciation and equilibrium.The addition of piperazine to potassium carbonate increases the rate of CO2 absorption by an order of magnitude at 60°C. The rate of CO2 absorption in the promoted solution compares favorably to that of MEA. The addition of piperazine to potassium carbonate increases the heat of absorption from 3.7 to . The capacity ranges from 0.4 to for PZ/K2CO3 solutions, comparing favorably with other amines.  相似文献   

20.
A gel polymer electrolyte (GPE) was prepared using tetra(ethylene glycol) diacrylate monomer, benzoyl peroxide, and (). The LiCoO2/GPE/graphite cells were prepared and their electrochemical properties were evaluated at various current densities and temperatures.The viscosity of the precursor containing the tetra(ethylene glycol) diacrylate monomer was around . The ionic conductivity of the gel polymer electrolyte at 20°C was around . The gel polymer electrolyte had good electrochemical stability up to vs. Li/Li+. The capacity of the LiCoO2/GPE/graphite cell at rate was 63% of the discharge capacity at rate. The capacity of the cell at −10°C was 81% of the discharge capacity at 20°C. Discharge capacity of the cell with gel polymer electrolyte was stable with charge-discharge cycling.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号