1.
PurposeTo compare conventional method of contact lens fitting with software based contact lens fitting using Medmont corneal topographer in eyes with nebular and macular corneal scars.MethodsFifteen participants who were diagnosed with nebular and macular scars were fitted with rigid gas permeable lenses using conventional method of contact lens fitting. During the lens dispensing visit, participants underwent Medmont corneal topography. Agreement between the two methods of contact lens fitting was studied.ResultsParameters of contact lenses which were concluded using conventional method was compared to that of software based fitting. Mean difference in base curve of contact lens between the two methods was 0.094 mm ± 0.147 mm (95% CI: +0.383 to −0.194). Mean difference in diameter of contact lens between the two methods was 0.16 mm ± 0.172 mm (95% CI: +0.497 to −0.177). Contact lens parameters that were achieved using two different methods of fitting showed good correlation. Correlation coefficients, as comparison of two methods in base curve and diameter were 0.96 (P < 0.05) and 0.94 (P < 0.05), respectively.ConclusionSoftware based contact lens fitting would be useful for contact lens practitioners to predict initial base curve of contact lens in corneal scars.  相似文献   

2.
PurposeTo investigate the differences of functional visual acuity (FVA) and high order aberrations (HOAs) in relation to tinted and clear hydrogel soft contact lens (SCL) wear.MethodsA prospective comparative study was performed in 16 eyes of 16 healthy volunteers. Dynamic visual acuity (using a FVA measurement system) and higher-order aberrations (using a wavefront sensor) were compared in subjects wearing two types of soft contact lenses: 1-day Acuvue® (Vistakon, Jacksonville, FL) clear and the 1-day Acuvue® DefineTM (Vistakon, Jacksonville, FL) tinted lens. The blink rates were recorded during FVA testing. The correlation between the difference of HOAs and differences in FVA values was analyzed.ResultsThe mean LogMAR FVA scores with clear and tinted SCLs were 0.07 ± 0.13 and 0.14 ± 0.17 (P < 0.05). The mean blink frequencies with clear and tinted SCL wear were 18.4 ± 8.3 and 25.3 ± 4.7 blinks/min (P < 0.05). Both 3rd-order aberrations and total HOAs showed statistically significant differences between the two types of soft contact lenses for 6 mm pupil measurements (P < 0.05). A significant positive linear correlation was observed between ΔHOAs and ΔLogMAR FVA for 6 mm pupil measurements (R = 0.53, P = 0.04).ConclusionsTinted contact lens wear appears to induce a reduction in optical quality. Functional visual acuity measurement is a useful procedure to study the changes of visual performance and quality in tinted contact lens wear.  相似文献   

3.
PurposeTo understand the pattern of prescribing contact lenses (CL) among Indian practitioners.MethodsSurvey forms were sent to 257 practitioners across the country to collect information about their last 10 CL fits, location and type of practice, years of experience and educational qualification. A logistic regression analysis was performed to determine any association of various factors to the lens fitting pattern and chi-square test was used to compare proportions. The data were analyzed using SPSS v.16.ResultsCL fitting details from 227 practitioners were acquired representing a total of 2270 fits. The mean age of patients was 26.8 ± 7.4 years and 67% of them were females. Ninety-eight percent of patients wore soft CL comprising 24% toric lenses. Ninety percent patients preferred disposable modality with 65% of these opting for monthly disposable lenses. Twenty-eight percent of the lenses dispensed were silicone hydrogel (SiH) lenses. Optometry practices located in metropolitan cities dispensed significantly higher numbers of disposable (p < 0.001) and SiH lenses (p < 0.001). Logistic regression analysis showed Fellowship of International Association of Contact Lens Educators (FIACLE) (OR: 13.79, 95% CI: 2.61–72.70), post graduate degree (OR: 3.87, 95% CI: 0.87–17.12) and years of experience were directly associated with fitting of advanced CL.ConclusionThe CL prescribing patterns in India elicited from this survey suggest the dominance (90%) of prescribing of disposable soft CL. Higher level of education, greater experience and a FIACLE status were significantly associated with advanced fitting.  相似文献   

4.
PurposeTo evaluate the impact of differente soft contact lens power in the anterior corneal curvature and regularity in subjects with keratoconus.MethodsNineteen subjects (30 eyes) with keratoconus were included in the study. Six corneal topographies were taken with Pentacam Eye System over the naked eye and successively with soft lens (Senofilcon A) powers of −3.00, −1.50, 0.00, +1.50 and +3.00 D. Corneal measurements of mean central keratometry (MCK), maximum tangential curvature (TK), maximum front elevation (MFE) and eccentricity (Ecc) at 6 and 8 mm diameters as well as anterior corneal surface high order aberrations (i.e. total RMS, spherical- and coma-like and secondary astigmatism) were evaluated.ResultsNegative- and plano-powered soft lenses flattened (p < 0.05 in all cases), whereas positive-powered lenses did not induce any significant changes (p > 0.05 in all cases) in MCK in comparison to the naked eye. The TK power decreased with negative lenses (p < 0.05 in both cases) and increased with +3.00 D lenses (p = 0.03) in comparison to the naked eye. No statistically significant differences were found in MFE with any soft lens power in comparison to the naked eye (p > 0.05 in all cases). Corneal eccentricity increased at 8 mm diameter for all lens powers (p < 0.05 in all cases). No statistically differences were found in HOA RMS and spherical-like aberration (both p > 0.05). Statistically differences were found in coma-like and secondary astigmatism (both p < 0.05).ConclusionNegative-powered soft contact lenses provide a flatter anterior surface in comparison to positive-powered lenses in subjects with keratoconus and thus they might be more suitable for piggyback contact lens fitting.  相似文献   

5.
PurposeTo investigate the accuracy of measuring intraocular pressure over a silicone hydrogel contact lens using Goldmann applanation tonometry in eyes with glaucoma.MethodsThis was a prospective, randomized study and enrolled 28 patients (28 right eyes) with primary open angle glaucoma. Intraocular pressure was taken with and without a silicone hydrogel contact lens (−0.50 D), in situ (using Goldmann applanation tonometry), in a randomized order of measurements. Statistical analysis was performed using paired t-test and Bland–Altman plot.ResultsThe mean difference (± standard deviation) found between intraocular pressure measurement without (mean 16.7 ± 3.2 mmHg) and with (mean 17.3 ± 3.0 mmHg) contact lens was found to be −0.57 ± 2.3 mmHg (95% confidence interval, −1.5 to 0.3). No significant statistical difference was found between the two groups with paired t-test (p = 0.19). The Bland Altman plot showed some evidence of increasing variability of differences between two measures of intraocular pressure, with increasing intraocular pressure. The 95% limits of agreement of the Bland Altman plot were unacceptably large (−5 mmHg to 3.9 mmHg).ConclusionAgreement between Goldmann applanation tonometry with and without contact lenses seems to be poor in patients with glaucoma, especially for high intraocular pressure.  相似文献   

6.
Purposeto evaluate changes in tear metrics and ocular signs induced by six months of silicone-hydrogel contact lens wear and the difference in baseline characteristics between those who successfully continued in contact lens wear compared to those that did not.MethodsNon-invasive Keratograph, Tearscope and fluorescein tear break-up times (TBUTs), tear meniscus height, bulbar and limbal hyperaemia, lid-parallel conjunctival folds (LIPCOF), phenol red thread, fluorescein and lissamine-green staining, and lid wiper epitheliopathy were measured on 60 new contact lens wearers fitted with monthly silicone-hydrogels (average age 36 ± 14 years, 40 females). Symptoms were evaluated by the Ocular Surface Disease Index (OSDI). After six months full time contact lens wear the above metrics were re-measured on those patients still in contact lens wear (n = 33). The initial measurements were also compared between the group still wearing lenses after six months and those who had ceased lens wear (n = 27).ResultsThere were significant changes in tear meniscus height (p = 0.031), bulbar hyperaemia (p = 0.011), fluorescein TBUT (p = 0.027), corneal (p = 0.007) and conjunctival (p = 0.009) staining, LIPCOF (p = 0.011) and lid wiper epitheliopathy (p = 0.002) after six months of silicone-hydrogel wear. Successful wearers had a higher non-invasive (17.0 ± 8.2 s vs 12.0 ± 5.6 s; p = 0.001) and fluorescein (10.7 ± 6.4 s vs 7.5 ± 4.7 s; p = 0.001) TBUT than drop-outs, although OSDI (cut-off 4.2) was also a strong predictor of success.ConclusionSilicone-hydrogel lenses induced significant changes in the tear film and ocular surface as well as lid margin staining. Wettability of the ocular surface is the main factor affecting contact lens drop-out.  相似文献   

7.
PurposeTo compare intraocular pressure (IOP) measured with ocular response analyzer (ORA) with and without soft contact lenses (CL) on eye.MethodsGoldmann correlated intraocular pressure (IOPg) and corneal compensated intraocular pressure (IOPcc) were measured in 56 eyes of 28 subjects without any ocular pathology, using ORA. One eye was fitted with Narafilcon A (1-Day Acuvue True Eye, Johnson & Johnson) and the other eye with Nelfilcon A (Daily AquaComfort Plus, Ciba Vision), each with −3.00D and IOPg and IOPcc were again measured over CL. The variation in the IOP with and without CL was determined.ResultsOut of 28 subjects, 54% (15) were female. Mean age of the subjects was 29.4 ± 9.8 years. Both the IOPg and IOPcc when measured with CL, were found statistically significantly lower than without CL (p < 0.05). In subjects wearing Narafilcon A lens, IOPg and IOPcc were found 0.88 ± 2.04 mmHg and 1.55 ± 2.16 mmHg lower than without CL, respectively. Similarly, with Nelfilcon A lens, IOPg and IOPcc were found to be 1.03 ± 1.93 mmHg and 1.62 ± 3.12 mmHg lower, respectively. IOPcc was highly affected and underestimated by more than 3 mmHg in upto 36% of the subjects.ConclusionMeasurement of IOP over minus (−3.00D) CL with ORA is dependent upon CL properties when measured in normal IOP population. It showed lower IOP over Narafilcon A and Nelfilcon A soft CL in comparison to the pressures measured without lenses. IOPg was found less affected by CL. For the accurate measurement of IOP with ORA, CL should be removed.  相似文献   

8.
PurposeTo evaluate the success rate of highly gas permeable scleral contact lenses (SCL) for visual rehabilitation after penetrating keratoplasty (PK), over a period of up to 9 years.MethodsA total database of 31 consecutive patient fitted with SCL between January 2004 and December 2009 was retrospectively reviewed. Demographic data, etiology prior to lens fitting, visual outcomes, follow up time and complications were analyzed.ResultsAll eyes were fitted due to inadequate spectacle-corrected vision after successful penetrating keratoplasty or failure of other contact lens modalities. Out of 31 patients fitted, 28 (33 eyes) continue to wear SCL for periods between 0.5 and 8.8 years. The mean duration of follow-up after contact lens fitting was 5.2 ± 2.2 years. The mean age of corneal graft was 17.6 ± 11.4 years (range 4.3–42), and the mean interval between PK and initial contact lens fitting was 12.2 ± 10.7 years (range 0.7–36.0). The average steepest keratometry of our cohort was 55.0 ± 7.5 diopter (D) and the refractive astigmatism was 8.0 ± 4.4 D. The mean contact lens corrected visual acuity (BCVAcl) was 0.78 ± 0.25 (range 0.3–1.2). Twenty-three (82%) patients achieved a functional vision of 0.5 or more.During the studied period, ten (30.0%) eyes presented at least one graft rejection episode and two eyes (6%) had an episode of microbial keratitis. Corneal transplants of 20 years or more show a higher rate of refits due to ectasia recurrence.ConclusionsScleral lenses should be considered as lens of choice in eyes with complex corneal geometry, as besides visual rehabilitation, their use may delay or prevent further surgical involvement.  相似文献   

9.
PurposeTo evaluate the performance of two experimental contact lenses (CL) designed to induce relative peripheral myopic defocus in myopic eyes.MethodsTen right eyes of 10 subjects were fitted with three different CL: a soft experimental lens (ExpSCL), a rigid gas permeable experimental lens (ExpRGP) and a standard RGP lens made of the same material (StdRGP). Central and peripheral refraction was measured using a Grand Seiko open-field autorefractometer across the central 60° of the horizontal visual field. Ocular aberrations were measured with a Hartman-Shack aberrometer, and monocular contrast sensitivity function (CSF) was measured with a VCTS6500 without and with the three contact lenses.ResultsBoth experimental lenses were able to increase significantly the relative peripheral myopic defocus up to −0.50 D in the nasal field and −1.00 D in the temporal field (p < 0.05). The ExpRGP induced a significantly higher myopic defocus in the temporal field compared to the ExpSCL. ExpSCL induced significantly lower levels of Spherical-like HOA than ExpRGP for the 5 mm pupil size (p < 0.05). Both experimental lenses kept CSF within normal limits without any statistically significant change from baseline (p > 0.05).ConclusionsRGP lens design seems to be more effective to induce a significant myopic change in the relative peripheral refractive error. Both lenses preserve a good visual performance. The worsened optical quality observed in ExpRGP was due to an increased coma-like and spherical-like HOA. However, no impact on the visual quality as measured by CSF was observed.  相似文献   

10.
PurposeTo investigate the efficacy of spherical aberration (SA) correction with aspheric contact lenses (aspheric lenses) based on lens power, and compare the results with those of spherical contact lenses (spherical lenses).MethodsOcular higher-order aberrations were measured with a wavefront sensor, in 11 myopic subjects wearing an aspheric lens (Medalist Fresh fit (PUREVISION 2 HD); Bausch + Lomb) or a spherical lens (ACUVUE Oasys; Johnson & Johnson). Six different lens powers (−7.00 diopters (D), −5.00 D, −3.00 D, −1.00 D, +1.00 D, +3.00 D) were used for all subjects. The amount of SA correction from the contact lens at each power was calculated as the difference between SA with the contact lens on-eye and SA of the eye alone.ResultsFor the spherical lenses, SA correction was close to 0.00 μm for the +1.00 D lens, became more positive as the labeled lens power increased and became more negative as the labeled lens power decreased. For the aspheric lenses, SA correction was consistent, from −0.15 to −0.05 μm, for all lens powers except for the −1.00 D lens. SA correction for the spherical and aspheric lenses was significantly different at −7.00 D (p = 0.040), −3.00 D (p = 0.015), −1.00 D (p < 0.001), +1.00 D (p = 0.006), and +3.00 D (p < 0.001) powers.ConclusionAn aspheric lens is capable of correcting SA at different lens powers, and has SA correction in the range of −0.15 to −0.05 μm over a 6 mm aperture.  相似文献   

11.
PurposeThe aim of the present study was to compare the objective and subjective visual performance of three different soft multifocal contact lenses.Methods10 subjects (habitual soft contact lens wearers) between the ages of 40 and 45 years participated in the study. Three different multifocal silicone hydrogel contact lenses (Acuvue Oasys, Air Optix and Biofinity) were fit within the same visit. All the lenses were fit according to the manufacturers’ recommendation using the respective fitting guide. Visual performance tests included low and high contrast distance and near visual acuity, contrast sensitivity, range of clear vision and through-focus curve. Objective visual performance tests included measurement of open field accommodative response at different defocus levels and optical aberrations at different viewing distances.ResultsAccommodative response was not significantly different between the three types of multifocal contact lenses at each of the accommodative stimulus levels (p > 0.05). Accommodative lag increased for higher stimulus levels for all 3 types of contact lenses. Ocular aberrations were not significantly different between these 3 contact lens designs at each of the different viewing distances (p > 0.05). In addition, optical aberrations did not significantly differ between different viewing distances for any of these lenses (p > 0.05). ANOVA revealed no significant difference in high and low contrast distance visual acuity as well as near visual acuity and contrast sensitivity function between the 3 multifocal contact lenses and spectacles (p > 0.05).ConclusionsThere was no statistically significant difference in accommodative response, optical aberrations or visual performance between the 3 multifocal contact lenses in early presbyopes.  相似文献   

12.
PurposeTo evaluate and compare the distribution of refractive power within the optic zone of different soft contact lenses and to investigate the effect of lens decentration on the power profiles.MethodsThe Nimo TR1504 instrument was used to measure the optical power across different aperture diameters (from 1.5 mm to 5.5 mm in steps of 0.5 mm) of four daily disposable contact lenses: DAILIES TOTAL1, Proclear 1-Day, SofLens daily disposable and 1-DAY ACUVUE MOIST. Measurements were performed using a wet cell. Power data were evaluated when contact lenses were in its centered position and after inducing different amounts of lens decentration (from 0.2 mm to 1.0 mm in steps of 0.2 mm).ResultsAll contact lenses showed an increase – more negative – in lens power with distance from the lens center. The amount of change varied depending on the lens. It was about 10% of lens power for DAILIES TOTAL1 (−0.29 diopters (D)), SofLens daily disposable (−0.36 D), and Proclear 1-Day (−0.32 D) whereas 1-DAY ACUVUE MOIST showed a percentage variation of 3.3% (−0.10 D). After inducing a lens decentration up to 1 mm, the power curves were shifted in the negative direction. However, the change obtained in lens power compared with well-centered position was always lower than a quarter of diopter both for all the lenses and aperture diameters.ConclusionsOur results showed a variation of the refractive power from the lens center, becoming more negative toward the periphery, with a negligible effect of the decentration for all disposable contact lenses studied.  相似文献   

13.
PurposeTo evaluate the efficacy of two silicone hydrogel (SiH) contact lenses, approved for continuous wear for one week, following photorefractive keratectomy (PRK).MethodsForty seven myopic patients (94 eyes) undergone bilateral PRK were enrolled in this prospective, double-masked, comparative study. One eye of each patient was fitted with a Lotrafilcon B lens (Ciba Vision, Duluth, US; 30-day recommended replacement) whereas the fellow eye was fitted with an Asmofilcon A lens (Menicon, Nagoya, Japan; 14-day recommended replacement). Epithelial defect size was assessed using slit lamp biomicroscopy on the day of surgery and at days 1–4 post-operatively. Uncorrected and best-corrected visual acuity and retinal straylight (C-Quant, Oculus Optigerate, Germany) were evaluated pre-operatively and one month post-operatively.ResultsAverage epithelial defect size for Asmofilcon A and Lotrafilcon B was 25.5 ± 11.0 mm2 vs. 27.1 ± 9.9 mm2 at day 1 (p = 0.007) and 6.3 ± 7.0 mm2 vs. 9.2 ± 9.5 mm2 at day 2 (p = 0.012) post-operatively. Re-epithelialization at day 3 was completed in 87.2% of the eyes fitted with Asmofilcon A lenses, compared to 74.5% with Lotrafilcon B lenses (p = 0.012). At the 3rd post-operative day 29.8% of re-epithelialized eyes showed irregular suture with Lotrafilcon B, compared to 12.8% eyes with Asmofilcon A lenses (p < 0.001). Finally, no statistically significant differences were found post-operatively between the two lenses retinal straylight (p = 0.98) and best-corrected visual acuity (p = 0.68).ConclusionsSiH lenses can be used as an effective bandage after PRK due to the limited time requested for achieving complete corneal re-epithelialization. Faster and smoother epithelial healing is provided with Asmofilcon A over Lotrafilcon B lenses.  相似文献   

14.
PurposeTo compare lens orientation and rotational recovery of five currently available soft toric lenses.MethodsTwenty subjects were recruited and trialed with each of the study lenses in a random order. Study lenses were PureVision® Toric (B&L), Air Optix® for Astigmatism (Alcon), Biofinity® Toric (CooperVision), Acuvue® Advance for Astigmatism (Vistakon), and Proclear® Toric (CooperVision). Lens orientation in primary position to determine the lens rotation form the vertical position and rotational recovery to primary gaze orientation following a 45° manual misorientation for the different lenses was compared.ResultsThe Biofinity Toric showed the lowest rotation from the vertical position and the Proclear Toric the highest. Also, the highest and the lowest reorientation speed were related to the Biofinity Toric and the Acuvue Advance for Astigmatism, respectively. The Repeated Measures ANOVA showed a significant difference in the lens rotation (P = 0.004) and rotational recovery (P < 0.001) among different contact lenses and the performed multiple comparisons indicated differences in rotation and also in reorientation speed were only seen between the Biofinity Toric when compared to four other lenses (P < 0.05).ConclusionAlthough there was appropriate fitting, based upon lens orientation and reorientation speed, with each of the study lenses it would appear that the optimized ballast technique used in the design of the Biofinity Toric helps reduce lens rotation and improve rotational recovery compared to others.  相似文献   

15.
PurposeTo examine the influence of short-term miniscleral contact lens wear on corneal shape, thickness and anterior surface aberrations.MethodsScheimpflug imaging was captured before, immediately following and 3 h after a short period (3 h) of miniscleral contact lens wear for 10 young (mean 27 ± 5 years), healthy participants. Natural diurnal variations were considered by measuring baseline diurnal changes obtained on a separate control day without contact lens wear.ResultsSmall but significant anterior corneal flattening was observed immediately following lens removal (overall mean 0.02 ± 0.03 mm, p < 0.001) which returned to baseline levels 3 h after lens removal. During the 3 h recovery period significant corneal thinning (−13.4 ± 10.5 μm) and posterior surface flattening (0.03 ± 0.02 mm) were also observed (both p < 0.01). The magnitude of posterior corneal flattening during recovery correlated with the amount of corneal thinning (r = 0.69, p = 0.03). Central corneal clearance (maximum tear reservoir depth) was not associated with corneal swelling following lens removal (r = −0.24, p > 0.05). An increase in lower-order corneal astigmatism Z(2,2) was also observed following lens wear (mean −0.144 ± 0.075 μm, p = 0.02).ConclusionsFlattening of the anterior corneal surface was observed immediately following lens wear, while ‘rebound’ thinning and flattening of the posterior surface was evident following the recovery period. Modern miniscleral contact lenses that vault the cornea may slightly influence corneal shape and power but do not induce clinically significant corneal oedema during short-term wear.  相似文献   

16.
PurposeTo quantify the influence of soft contact lens power and thickness on the intraocular pressure (IOP).MethodsThirty-nine young, healthy adult volunteers completed this study. One eye of each subject was randomly assigned either a +6D or a ?6D high water content daily disposable lens. The other eye was fitted with the second lens. Triplicate measurements of IOP were taken before, during, and after contact lens wear. Each time, IOP was assessed in a randomized order with two noncontact tonometers. The lenses were swapped between eyes during a second session of measurements, one week later.ResultsIn the first session with the +6D lenses, the average IOPs (±SDs) before, with the lenses fitted, and after the lenses were removed, were: 14.3 ± 2.9 mmHg, 17.0 ± 3.3 mmHg and 13.9 ± 3.1 mmHg, respectively, for the CT80 and 13.6 ± 3.1 mmHg, 17.1 ± 4.5 mmHg and 13.3 ± 2.9 mmHg, respectively, for the PT100. The corresponding values for the first session with the ?6D lenses were: 14.3 ± 3.1 mmHg, 13.1 ± 3.1 mmHg and 14.1 ± 3.3 mmHg, respectively, for the CT80 and 13.6 ± 3.2 mmHg, 13.0 ± 3.0 mmHg and 13.6 ± 3.2 mmHg, respectively, for the PT100. IOP significantly (P < 0.05) increased (+ΔIOP = 2.7 ± 0.4 mmHg with the CT80 in the first session) with the +6D lenses, but decreased (P < 0.05) when the ?6D lenses were fitted (?ΔIOP = 0.6 ± 0.2 mmHg with the PT100 in the first session). The soft contact lens-induced changes were consistent between sessions but varied between tonometers.ConclusionsThe measurement of IOP through soft contact lenses resulted in consistent, statistically significant differences in IOP, which were not uniform across tonometers and which did not appear to be solely related to the central thickness of the soft contact lenses.  相似文献   

17.
PurposeThe aim of this study was to compare central corneal thickness (CCT) between corneas of normal healthy eyes (cNHE), corneas of eyes that had undergone cataract surgery by clear corneal phacoemulsification with implantation of an intracapsular intraocular lens (cIOL), corneal grafts after penetrating keratoplasty (gPK) and corneas of long-term soft contact lens wearers (cCL).MethodsThe study design was a consecutive cross-sectional trial. CCT was measured using rotating Scheimpflug camera (Pentacam, software version 1.16r04) in 80 cNHE, 79 cIOL, 46 gPK and 78 cCL. Analysis of variance (one-way ANOVA) was performed to compare differences of mean values between these four groups. Pearson's or Spearman's correlation coefficient (r) was determined between CCT value and age, follow up time after penetrating keratoplasty (timePK) or contact lens wearing time (timeCL).ResultsMeans of CCT measurements were comparable between cNHE (mean CCT ± standard deviation, 554 ± 36 μm), cIOL (551 ± 40 μm) and gPK (534 ± 52 μm) as determined by one-way ANOVA. Mean CCT values in cCL (537 ± 37 μm) were statistically significantly lower in comparison to cNHE (p = 0.026, 95% CI = 1.43–31.44). There was no linear correlation between age and CCT values of cNHE and cIOL (p = 0.841, r = −0.031 and p = 0.931, r = 0.011, respectively). No linear relationship was determined between CCT values of cCL and timeCL (p = 0.315, r = −0.125). CCT values of gPK did not correlate with timePK (p = 0.738, r = 0.054).ConclusionsThe data reported here indicate that in the same statistical model among CCT values of cNHE, cIOL and gPK only long-term soft contact lenses (CL) wearer have significantly lower CCT measurements.  相似文献   

18.
PurposeThe aim of this cross-over study was to investigate the changes in corneal thickness, anterior and posterior corneal topography, corneal refractive power and ocular wavefront aberrations, following the short term use of rigid contact lenses.MethodFourteen participants wore 4 different types of contact lenses (RGP lenses of 9.5 mm and 10.5 mm diameter, and for comparison a PMMA lens of 9.5 mm diameter and a soft silicone hydrogel lens) on 4 different days for a period of 8 h on each day. Measures were collected before and after contact lens wear and additionally on a baseline day.ResultsAnterior corneal curvature generally showed a flattening with both of the RGP lenses and a steepening with the PMMA lens. A significant negative correlation was found between the change in corneal swelling and central and peripheral posterior corneal curvature (all p  0.001). RGP contact lenses caused a significant decrease in corneal refractive power (hyperopic shift) of approximately 0.5 D. The PMMA contact lenses caused the greatest corneal swelling in both the central (27.92 ± 15.49 μm, p < 0.001) and peripheral (17.78 ± 12.11 μm, p = 0.001) corneal regions, a significant flattening of the posterior cornea and an increase in ocular aberrations (all p  0.05).ConclusionThe corneal swelling associated with RGP lenses was relatively minor, but there was slight central corneal flattening and a clinically significant hyperopic change in corneal refractive power after the first day of lens wear. The PMMA contact lenses resulted in significant corneal swelling and reduced optical performance of the cornea.  相似文献   

19.
PurposeContact lenses that incorporate antimicrobial properties may reduce the risk for microbial-associated adverse events for lens wearers. The aim of this study was to assess the antimicrobial effects of silver nanoparticles (NP) when impregnated in a hydrogel material.MethodsHydrogel disks, used as a proxy for soft contact lenses, were prepared with silver NPs to add an antimicrobial effect to the polymer. Six groups of disks were created, each with a different concentration of silver NPs. The antimicrobial effect of the hydrogels against Pseudomonas aeruginosa (ATCC15442) and Staphylococcus aureus (ATCC6538) was evaluated at 6, 24, 48 and 72 h.ResultsSilver NP concentrations ranged from 20.71 to 98.06 μg/disk. All groups demonstrated excellent antibacterial effects against P. aeruginosa at each time point. After 6 h all disks didn’t exhibit desirable antibacterial activity against S. aureus; whereas except those with 20.71 μg silver NPs showed antibacterial activity at 24 h and only the disks with 57.13 and 98.06 μg silver NPs showed antimicrobial activity at 48 and 72 h.ConclusionsThe development of contact lenses made of a silver NP-impregnated hydrogel material may bring antimicrobial effects sufficient to decrease the risk of microbial-related adverse events for lens wearers.  相似文献   

20.
PurposeTo investigate the efficacy and safety of a fenestrated and channelled soft contact lens (F-SCL) compared to a standard and non-fenestrated soft contact lens (S-SCL) in experienced soft contact lens (SCL) wearers.MethodsThis was a randomised, crossover, single-blinded (subject), and multicentre clinical trial. Sixteen experienced SCL wearers were randomly divided into two groups (FS and SF). The FS group first wore F-SCLs followed by S-SCLs, each for 10 days, separated by a 1-week washout period, whereas the SF group wore the S-SCLs first and crossed over to F-SCLs in the same manner. The F-SCLs were designed with three equally spaced, symmetrical fenestrations and a partial-thickness, connecting, circumferential channel on the back surface of the mid-periphery of the lens. Measurement of central corneal thickness using ultrasonic pachymetry was performed on the day of screening, after the 1-week washout period, and after 10 days of wearing each kind of lens, based on which central corneal swelling was calculated and compared. One eye in each subject was chosen at random for analysis.ResultsCentral corneal swelling was 1.92 ± 1.73% vs. 5.26 ± 2.14% in F-SCLs vs. S-SCLs wearers, which was statistically significant (P < 0.001). There was no significant difference between the groups in terms of SCL-corrected visual acuity or SCL-related adverse events.ConclusionThe use of F-SCLs led to reduced corneal swelling compared to S-SCLs. The newly incorporated features appear to improve tear mixing and thereby the oxygen supply to the cornea, which results in reduced corneal oedema.  相似文献   