共查询到20条相似文献,搜索用时 15 毫秒
1.
Poly(2-hydroxyethyl methacrylate) [poly(HEMA)] membranes were prepared by UV-initiated photopolymerization of HEMA in the presence of an initiator (α-α′-azobis-isobutyronitrile, AIBN). The triazine dye Cibacron Blue F3GA was attached as an affinity ligand to poly(HEMA) membranes, covalently. These affinity membranes with a swelling ratio of 58% and containing 10.7 mmol Cibacron Blue F3GA/m2 were used in the albumin adsorption studies. After dye-attachment, Zn(II) ions were chelated within the membranes via attached-dye molecules. Different amounts of Zn(II) ions [650–1440 mg Zn(II)/m2] were loaded on the membranes by changing the initial concentration of Zn(II) ions and pH. Bovine serum albumin (BSA) adsorption on these membranes from aqueous solutions containing different amounts of BSA at different pH was investigated in batch reactors. The nonspecific adsorption of BSA on the poly(HEMA) membranes was negligible. Cibacron Blue F3GA attachment significantly increased the BSA adsorption up to 92.1 mg BSA/m2. Adsorption capacity was further increased when Zn(II) ions were attached (up to 144.8 mg BSA m2). More than 90% of the adsorbed BSA was desorbed in 1 h in the desorption medium containing 0.5M NaSCN at pH 8.0 and 0.025M EDTA at pH 4.9. © 1998 John Wiley & Sons, Inc. J Appl Polym Sci 68: 657–664, 1998 相似文献
2.
An affinity dye ligand, Cibacron Blue F3GA, was covalently attached onto magnetic poly(2‐hydroxyethyl methacrylate) (mPHEMA) beads for human serum albumin (HSA) adsorption from both aqueous solutions and human plasma. The mPHEMA beads, in the size range of 80 to 120 µm, were prepared by a modified suspension technique. Cibacron Blue F3GA molecules were incorporated on to the mPHEMA beads. The maximum amount of Cibacron Blue F3GA attachment was obtained as 68.3 µmol g?1. HSA adsorption onto unmodified and Cibacron Blue F3GA‐attached mPHEMA beads was investigated batchwise. The non‐specific adsorption of HSA was very low (1.8 mg g?1). Cibacron Blue F3GA attachment onto the beads significantly increased the HSA adsorption (94.5 mg g?1). The maximum HSA adsorption was observed at pH 5.0. Higher HSA adsorption was observed from human plasma (138.3 mg HSA g?1). Desorption of HSA from Cibacron Blue F3GA‐attached mPHEMA beads was obtained by using 0.1 M Tris/HCl buffer containing 0.5 M NaSCN. High desorption ratios (up to 98% of the adsorbed HSA) were observed. It was possible to re‐use Cibacron Blue F3GA‐attached mPHEMA beads without any significant decreases in their adsorption capacities. Copyright © 2004 Society of Chemical Industry 相似文献
3.
以纤维素滤纸膜为载体,染料Cibacron Blue F3GA为配基,制备了一种新型亲和膜色谱介质。采用扫描电镜、红外光谱、元素分析等方法对亲和膜介质进行鉴定与表征,该膜具有良好的色谱性能。亲和膜对F3GA的键合质量摩尔浓度达93.7μmol/g。研究了木瓜蛋白酶在亲和膜上的吸附行为,实验表明:在30℃下、酶质量浓度为2 mg/mL、pH=8.0时,吸附质量比可达57.9 mg/g,改变pH值及离子强度等条件对吸附质量比有明显的影响。在最适条件下吸附遵循Langmuir型吸附。可以初步推断,纤维素滤纸膜可以制成性能优良的亲和膜色谱介质,成本低廉,适合工业化分离纯化生物大分子。 相似文献
4.
Poly(ethylene glycol dimethacrylate-hydroxyethyl methacrylate) [poly-(EGDMA-HEMA)]microbeads in the size range of 150–200 μm were produced by a modified suspension copolymerization of EGDMA and HEMA. The dyes (Congo red, Cibacron blue F3GA, and alkali blue 6B) were covalently immobilized; then, Zn(II) ions were incorporated within the microbeads by chelation with the dye molecules. The maximum amounts of dye loadings were 14.5 μmol/g, 16.5 μmol/g, and 23.7 μmol/g for Congo red, Cibacron blue F3GA, and alkali blue 6B, respectively. Different amounts of Zn(II) ions(2.9–53.8 mg/g polymer) were incorporated on the microbeads by changing the initial concentration of Zn(II) ions and the pH of the medium. Bovine serum albumin (BSA) adsorption onto dye/Zn(II)-derived microbeads containing Congo red, Cibacron blue F3GA, and alkali blue 6B was investigated. The maximum BSA adsorptions onto the dye/Zn(II)-derived microbeads from aqueous solutions containing different amounts of BSA were 159 mg/g, 122 mg/g, and 93 mg/g for the Congo red, Cibacron blue F3GA, and alkali blue 6B dyes, respectively. The maximum BSA adsorptions were observed at pH 6.0 in all cases. Desorption of BSA molecules was achieved by using 0.025M EDTA (pH 4.9). High desorption ratios (more than 93% of the adsorbed BSA) were observed in all cases. It was possible to reuse these novel metal chelate sorbents without significant losses in their adsorption capacities. © 1997 John Wiley & Sons, Inc. J Appl Polym Sci 65: 2085–2093, 1997 相似文献
5.
Poly(N-vinylimidazole) (PVIm) gels were prepared by irradiating a binary mixture of N-vinylimidazole (VIm)–water in a 60Co-γ source having 4.5 kGy/h dose rate. In the glucose oxidase (GOx) adsorption studies, affinity gels with a swelling ratio of 1100% for PVIm and 40 and 55% for Cu(II)- and Co(II)-chelated PVIm gels, respectively, at pH 6.5 in phosphate buffer were used. FTIR spectra were taken for PVIm and Cu(II)- and Co(II)-chelated PVIm, and glucose oxidase adsorption on these gels, to characterize the nature of the interactions in each species. The results show that PVIm–glucose oxidase interaction is mainly electrostatic and metal ion–chelated PVIm gel–glucose oxidase interaction is of coordinate covalent nature. Cu(II) and Co(II) ions were chelated within the gels via amine groups on the imidazole ring of the gel. Different amounts of Cu(II) and Co(II) ions [maximum 3.64 mmol/g dry gel for Cu(II) and 1.72 mmol/g dry gel for Co(II)] were loaded on the gels by changing the initial concentration of Cu(II) and Co(II) ions at pH 7.0. GOx adsorption on these gels from aqueous solutions containing different amounts of GOx at different pH was investigated in batch reactors. GOx adsorption capacity was further increased when Cu(II) and Co(II) ions were attached [up to 0.53 g GOx/g dry Co(II)-chelated PVIm gels]. More than 90% of the adsorbed GOx was desorbed in 5 h in desorption medium containing 1.0M KSCN at pH 7.0 for plain gel and 0.05M EDTA at pH 4.9 for metal-chelated gel. Nonspecific glucose oxidase adsorption on/in the metal ion–chelated PVIm gel was investigated using 0.02M of phosphate buffer solution. The nonspecific GOx adsorption was determined to be about 18% for PVIm and 8% for the metal ion–chelated PVIm gels. The ionic strength effect was investigated both on PVIm and on the metal ion–chelated PVIm gels for the glucose oxidase adsorption. It was found that ionic strength was more effective on the PVIm gel because of the electrostatic interaction between protonated gel and the deprotonated glucose oxidase side chain. © 2001 John Wiley & Sons, Inc. J Appl Polym Sci 82: 446–453, 2001 相似文献
6.
Lysozyme adsorption onto Cibacron Blue F3GA attached and Cu(II) incorporated poly(2-hydroxyethyl methacrylate–ethylene glycol dimethacrylate) [poly(HEMA-EGDMA)] microspheres was investigated. The microspheres were prepared by suspension polymerization. Various amounts of Cibacron Blue F3GA were attached covalently onto the microspheres by changing the initial concentration of dye in the reaction medium. The microspheres with a swelling ratio of 65%, and carrying different amounts of dye (between 1.4 and 22.5 µmol/g−1) were used in the lysozyme adsorption studies. Lysozyme adsorption on these microspheres from aqueous solutions containing different amounts of lysozyme at different pH values was investigated in batch reactors. The lysozyme adsorption capacity of the dye–metal chelated microspheres (238.2 mg g−1) was greater than that of the dye-attached microspheres (175.1 mg g−1). The maximum lyzozyme adsorption capacities (qm) and the dissociation constant (kd) values were found to be 204.9 mg g−1 and 0.0715 mg ml−1 with dye-attached and 270.7 mg g−1 and 0.0583 mg ml−1 with dye–metal chelated microspheres, respectively. More than 90% of the adsorbed lysozyme were desorbed in 60 min in the desorption medium containing 0.5 M KSCN at pH 8.0 or 25 mM EDTA at pH 4.9. © 1999 Society of Chemical Industry 相似文献
7.
Epoxy group‐containing poly(hydroxyethyl methacrylate/glycidyl methacrylate), p(HEMA/GMA), membrane was prepared by UV initiated photopolymerization. The membrane was grafted with chitosan (CH) and some of them were chelated with Fe(III) ions. The CH grafted, p(HEMA/GMA), and Fe(III) ions incorporated p(HEMA/GMA)‐CH‐Fe(III) membranes were used for glucose oxidase (GOD) immobilization via adsorption. The maximum enzyme immobilization capacity of the p(HEMA/GMA)‐CH and p(HEMA/GMA)‐CH‐Fe(III) membranes were 0.89 and 1.36 mg/mL, respectively. The optimal pH value for the immobilized GOD preparations is found to have shifted 0.5 units to more acidic pH 5.0. Optimum temperature for both immobilized preparations was 10°C higher than that of the free enzyme and was significantly broader at higher temperatures. The apparent Km values were found to be 6.9 and 5.8 mM for the adsorbed GOD on p(HEMA/GMA)‐CH and p(HEMA/GMA)‐CH‐Fe(III) membranes, respectively. In addition, all the membranes surfaces were characterized by contact angle measurements. © 2006 Wiley Periodicals, Inc. J Appl Polym Sci 103: 3084–3093, 2007 相似文献
8.
Lysozyme adsorption onto dye‐attached nonporous monosize poly(2‐hydroxyethyl‐methacrylate‐methylmethacrylate) [poly(HEMA‐MMA)] microspheres was investigated. Poly(HEMA‐MMA) microspheres were prepared by dispersion polymerization. The monochloro‐triazine dye, Cibacron Blue F3GA, was immobilized covalently as dye–ligand. These dye‐affinity microspheres were used in the lysozyme adsorption–desorption studies. The effect of initial concentration of lysozyme and medium pH on the adsorption efficiency of dye‐attached and metal‐chelated microspheres were studied in a batch reactor. Effect of Cu(II) chelation on lysozyme adsorption was also studied. The nonspecific adsorption of lysozyme on the poly(HEMA‐MMA) microspheres was 3.6 mg/g. Cibacron Blue F3GA attachment significantly increased the lysozyme adsorption up to 247.8 mg/g. Lysozyme adsorption capacity of the Cu(II) incorporated microspheres (318.9 mg/g) was greater than that of the Cibacron Blue F3GA‐attached microspheres. Significant amount of the adsorbed lysozyme (up to 97%) was desorbed in 1 h in the desorption medium containing 1.0M NaSCN at pH 8.0 and 25 mM EDTA at pH 4.9. In order to examine the effects of separation conditions on possible conformational changes of lysozyme structure, fluorescence spectrophotometry was employed. We conclude that dye‐ and metal‐chelate affinity chromatography with poly(HEMA‐MMA) microspheres can be applied for lysozyme separation without causing any significant changes and denaturation. Repeated adsorption/desorption processes showed that these novel dye‐attached monosize microspheres are suitable for lysozyme adsorption. © 2000 John Wiley & Sons, Inc. J Appl Polym Sci 76: 115–124, 2000 相似文献
9.
The aim of this study was to investigate the heavy metal adsorption performance of supermacroporous poly(hydroxyethyl methacrylate) [PHEMA] cryogel. The PHEMA cryogel was produced by cryo‐polymerization. The PHEMA cryogel was characterized by scanning electron microscopy (SEM). The PHEMA cryogel containing 385 μmol Reactive Green HE‐4BD/g were used in the adsorption studies. Adsorption capacity of the PHEMA cryogel for the metal ions, i.e., Cu2+, Cd2+, and Pb2+ were investigated in aqueous media containing different amounts of the ions (5–600 mg/L) and at different pH values (3.2–6.9). The maximum adsorption capacities of the PHEMA cryogel were 11.6 mg/g (56 μmol/g) for Pb2+, 24.5 mg/g (385 μmol/g) for Cu2+ and 29.1 mg/g (256 μmol/g) for Cd2+. The competitive adsorption capacities were 10.9 mg/g (52 μmol/g) for Pb2+, 22.1 mg/g for Cd2+ (196 μmol/g) and 23.2 mg/g (365 μmol/g) for Cu2+. The PHEMA/Reactive Green HE‐4BD cryogel exhibited the following metal ion affinity sequence on molar basis: Cu2+ > Cd2+ > Pb2+. The PHEMA/Reactive Green HE‐4BD cryogel can be easily regenerated by 50 mM EDTA with higher effectiveness. These features make the PHEMA/Reactive Green HE‐4BD cryogel a potential adsorbent for heavy metal removal. © 2010 Wiley Periodicals, Inc. J Appl Polym Sci, 2010 相似文献
10.
In this study, chitosan microspheres were prepared and characterized for adsorption of human serum albumin (HSA) as affinity sorbent. The chitosan microspheres were obtained with a “suspension crosslinking technique” in the size range of 30–700 μm by using a crosslinker, i.e., glutaraldehyde. The chitosan microspheres used in HSA adsorption studies were having the average size of 170 ± 81 μm. Adsorption medium pH and the initial HSA concentration in the adsorption medium were changed as 4.0–7.0 and 0.5–2.0 mg HSA/mL, respectively, to investigate the HSA adsorption capacity of chitosan microspheres. Maximum HSA adsorption (i.e., 11.35 mg HSA/g chitosan microspheres) was obtained at pH 5.0 and 1.5 mg HSA/mL of the initial HSA concentration in the adsorption medium was obtained as the saturation value for HSA adsorption. A very common dye ligand, i.e., Cibacron Blue F3GA was attached to the chitosan microspheres to increase the HSA adsorption capacity. Actually, the HSA adsorption capacity was increased up to 15.35 mg HSA/g chitosan microspheres in the case of Cibacron Blue F3GA attached to chitosan microspheres used. © 2002 Wiley Periodicals, Inc. J Appl Polym Sci 86: 3035–3039, 2002 相似文献
11.
BACKGROUND: New magnetic carrier separation technologies, capable of treating dilute solutions in large‐scale processes, even in the presence of biological debris, are necessary for the future development of biotechnology. Non‐porous magnetic carriers are more resistant to fouling, show better mass transfer and have lower non‐specific adsorption than porous carriers. Nanosized magnetic carriers have a surface area comparable to that of typical macroporous resins, and therefore their application has advantages. RESULTS: Magnetic poly(methyl methacrylate) (PMMA) nanospheres with an average diameter of 76 nm and narrow size distribution were prepared by a facile mini‐emulsion polymerization. After surface modification with poly(ethylene glycol), Cibacron Blue F3GA (CB) was coupled to the magnetic PMMA nanospheres to form dye ligand‐attached magnetic adsorbents for bovine serum albumin (BSA) adsorption. The CB‐coupled magnetic PMMA nanospheres showed very high adsorption capacity (121.98 mg g?1) and little non‐specific adsorption for BSA. The adsorbed protein could be easily desorbed using high ionic strength solution. CONCLUSION: The CB‐coupled magnetic PMMA nanospheres showed a high BSA adsorption capacity, low non‐specific adsorption and fast adsorption kinetics in comparison with other dye‐affinity adsorbents. These characteristics indicate that these magnetic PMMA nanospheres have great potential for protein affinity separation and purification. Copyright © 2009 Society of Chemical Industry 相似文献
12.
Adil Denizli Gülay Kktürk Handan Yavuz Erhan Pikin 《Reactive and Functional Polymers》1999,40(3):195-203
Affinity dye-ligand Cibacron Blue F3GA, was covalently coupled with poly(EGDMA-HEMA) microbeads via nucleophilic reaction between the chloride of its triazine ring and the hydroxyl groups of the HEMA under alkaline conditions. The microbeads carrying 16.5 μmol Cibacron Blue F3GA per gram polymer was incorporated with Zn(II) ions. Zn(II) loading was 189.6 μmol/g. Cibacron Blue F3GA-Zn(II) attached affinity sorbent was used for albumin adsorption from aqueous solutions and human plasma in a packed-bed column. BSA adsorption capacity of the microbeads decreased with an increase in the recirculation rate. High adsorption rates were observed at the beginning, then equilibrium was gradually achieved in about 60 min. The BSA concentration in the mobile phase also effected adsorption. BSA adsorption was first increased with BSA concentration, then reached a plateau which was about 128 mg BSA/g. The maximum adsorption was observed at pH 5.0 which is the isoelectric pH of BSA. Higher human serum albumin adsorption was observed from human plasma (215 mg HSA/g). High desorption ratios (over 90% of the adsorbed albumin) were achieved by using 1.0 M NaSCN (pH 8.0) in 30 min. 相似文献
13.
An amperometric choline biosensor was constructed by immobilizing choline oxidase (ChO) on poly(2‐hydroxyethyl methacrylate) (PHEMA)‐grafted Teflon (polytetrafluoroethylene, PTFE) film. Grafting was achieved by γ irradiation. PHEMA‐grafted Teflon films were activated with epichlorohydrin or glutaraldehyde to achieve covalent immobilization of enzyme onto the film. To decrease the diffusional barrier caused by the enzyme‐immobilized film, the film was stretched directly on the electrode. The PHEMA‐grafted Teflon film, therefore, had to have appropriate mechanical properties. Glucose oxidase (GOD) was used in the determination of optimum immobilization conditions, then these were applied to ChO. With GOD, the effect of activation type and film position in electrode on enzyme activity was studied and the highest catalytic activity was obtained when the enzyme was immobilized using glutaraldehyde and the film was stretched over the electrode surface. Further studies revealed that the films activated with glutaraldehyde, immobilized in 2 mg/mL ChO concentration, and stretched directly on the electrode were suitable (specific activity, 0.427 ± 0.068 U mg?1) for use in the choline biosensor. The linear working range of this biosensor was found to be 52–348 μM, with a 40 ± 5 μM minimum detection limit. The response of the sensor, however, decreased linearly upon repeated use. © 2007 Wiley Periodicals, Inc. J Appl Polym Sci, 2007 相似文献
14.
Metal chelating properties of Cibacron Blue F3GA‐derived poly(EGDMA‐HEMA) microbeads have been studied. Poly(EGDMA‐HEMA) microbeads were prepared by suspension copolymerization of ethylene glycol dimethacrylate (EGDMA) and hydroxy‐ethyl methacrylate (HEMA) by using poly(vinyl alcohol), benzoyl peroxide, and toluene as the stabilizer, the initiator, and the pore‐former, respectively. Cibacron Blue F3GA was covalently attached to the microbeads via the nucleophilic substitution reaction between the chloride of its triazine ring and the hydroxyl groups of the HEMA, under alkaline conditions. Microbeads (150–200 μm in diameter) with a swelling ratio of 55%, and carrying 16.5 μmol Cibacron Blue F3GA/g polymer were used in the adsorption/desorption studies. Adsorption capacity of the microbeads for the selected metal ions, i.e., Cu(II), Zn(II), Cd(II), Fe(III), and Pb(II) were investigated in aqueous media containing different amounts of these ions (5–200 ppm) and at different pH values (2.0–7.0). The maximum adsorptions of metal ions onto the Cibacron Blue F3GA‐derived microbeads were 0.19 mmol/g for Cu(II), 0.34 mmol/g for Zn(II), 0.40 mmol/g for Cd(II), 0.91 mmol/g for Fe(III), and 1.05 mmol/g for Pb(II). Desorption of metal ions were studied by using 0.1 M HNO3. High desorption ratios (up to 97%) were observed in all cases. Repeated adsorption/desorption operations showed the feasibility of repeated use of this novel sorbent system. © 1999 John Wiley & Sons, Inc. J Appl Polym Sci 71: 1397–1403, 1999 相似文献
15.
16.
β-Galactosidase was immobilized in/on poly(2-hydroxyethyl methacrylate) (pHEMA) membranes by two different methods: adsorption on Cibacron F3GA derivatized pHEMA membranes (pHEMA-CB), and entrapment in the bulk of the pHEMA membranes. The maximum β-galactosidase adsorption on pHEMA-CB membranes was obtained as 95·6μgcm-2 in 2·0mgcm-3 enzyme solution. The adsorption phenomena appeared to follow a typical Langmuir isotherm. In the entrapment, an increase in β-galactosidase loading resulted in a consistent increase in membrane activity from 3·3×10-2 to 17·8×10-2Ucm-2 pHEMA membranes. The Km values for both immobilized β-galactosidase (adsorbed 0·32mM and entrapped 0·81mM ) were higher than that of the free enzyme (0·26mM ). The optimum reaction temperature of the adsorbed enzyme was 5°C higher than that of both the free and the entrapped enzyme. The optimum reaction pH was 7·5 for free and both immobilized preparations. After 15 successive uses the retained activity of the adsorbed and the entrapped enzymes was 80% and 95%, respectively. The storage stability of the enzyme was found to increase upon immobilization. ©1997 SCI 相似文献
17.
This paper describes the application of a photoinitiated polymerisation-induced phase separation method to the preparation of PHEMA and P[HEMA-co-(MeO-PEGMA)] hydrogels. PHEMA sponges having a morphology of agglomerated polymer droplets and interconnected pores were easily prepared from aqueous mixtures containing HEMA, EDGMA (crosslinker) and DPAP (photoinitiator). P[HEMA-co-(MeO-PEGMA)] copolymers having similar morphologies could also be prepared, provided that the proportion of MeO-PEGMA in the copolymer was relatively small. When higher proportions of MeO-PEGMA were used, the resulting polymers were gels rather than sponges, and did not show the sought after droplet/pore morphology. P[HEMA-co-(MeO-PEGMA)] copolymers having higher proportions of MeO-PEGMA and having a morphology of agglomerated polymer droplets and interconnected pores were easily prepared by addition of NaCl to the polymerisation mixture. Thus, incorporation of MeO-PEGMA and adddition of NaCl to the photopolymerisation mixtures provides an easy way of tuning the hydrophilicity of PHEMA copolymer sponges without compromising the desired porous morphology. 相似文献
18.
19.
A new membrane affinity biosorbent carrying thionein has been developed for selective removal of cadmium ions from human serum. Microporous poly(2‐hydroxyethyl methacrylate) (pHEMA) membranes were prepared by photopolymerization of HEMA. The pseudo dye ligand Cibacron Blue F3GA (CB) was covalently immobilized on the pHEMA membranes. Then, the cysteine‐rich metallopeptide thionein was conjugated onto the CB‐immobilized membrane. The maximum amounts of CB immobilized and thionein conjugated on the membranes were 1.07 µmol cm−2 and 0.92 µmol cm−2, respectively. The hydrophilic pHEMA membrane had a swelling ratio of 58% (w/w) with a contact angle of 45.8 °. CB‐immobilized and CB‐immobilized–thionein‐conjugated membranes were used in the Cd(II) removal studies. Cd(II) ion adsorption appeared to reach equilibrium within 30 min and to follow a typical Langmuir adsorption isotherm. The maximum capacity (q m) of the CB‐immobilized membranes was 0.203 (µmol Cd(II)) cm−2 membrane and increased to 1.48 (µmol Cd(II)) cm−2 upon CB–thionein‐complex conjugation. The pHEMA membranes retained their cadmium adsorption capacity even after 10 cycles of repeated use. © 2000 Society of Chemical Industry 相似文献
20.
Monodisperse nonporous crosslinked poly(glycidyl methacrylate) (PGMA) particles with immobilized metal affinity ligands were prepared for selective recovery of proteins. The PGMA particles, with an average size of 2.2 µm, were prepared by a simple dispersion polymerization of glycidyl methacrylate (GMA) and ethylene glycol dimethacrylate (EGDMA). The particles were characterized by scanning electron microscopy (SEM) and Fourier‐transform infrared spectroscopy (FTIR). The epoxy groups of the particles were modified with the metal chelating agent iminodiacetic acid (IDA), which forms metal–IDA chelates at the active sites. After charging with copper ions, the particles were used to recover a model protein, bovine hemoglobin (BHb), in a batchwise manner. The particles had the adsorption capacity of 218.7 mg g−1 with little nonspecific adsorption. The adsorption behavior could be described with the Langmuir equation. The effect of pH on the adsorption was also studied. Regeneration of the metal‐chelated particles was easily performed with 50 mmol L−1 ethylenediaminetetraacetic acid (EDTA), followed by washing with water and reloading with Cu2+. The particles could be very useful as an affinity separation adsorbent. Copyright © 2005 Society of Chemical Industry 相似文献