首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 18 毫秒
1.
Ascorbic (H2A) and dehydroascorbic (DA) acids were for the first time directly determined in a single chromatographic run by means of the tris(2,2'-bipyridine)ruthenium(II) (Ru(bpy)(3)2+) based electrogenerated chemiluminescence (ECL) detection. For the first time, it was demonstrated that DA, a nonelectroactive compound, is ECL active and is responsible for the ECL behavior of H2A. This fact, together with the lack of a DA standard, suggested the use of a calibration graph obtained for H2A, for determining both analytes. The proven ECL activity of DA, together with literature data relative to the standard redox potentials of the different species coming from H2A, led to a reconsideration of the proposed ECL reaction mechanism for H2A. The role of the OH- ion in the reaction mechanism of the two analytes appeared to be crucial. H2A and DA could be separated by a suitable C18-reversed-phase HPLC column using an aqueous 30 mM H3PO4 solution as the mobile phase. The optimal ECL response was achieved by polarizing the working electrode at 1.150 Vvs SCE (standard calomel electrode) (oxidation diffusion limiting potential for both H2A and Ru(bpy)(3)2+). The Ru(bpy)(3)2+ solution, at pH 10 for carbonate buffer, was mixed to the eluent solution in a postcolumn system, obtaining, still at pH 10, the final 0.25 mM Ru(bpy)(3)2+ concentration. The detection limit found for the two analytes was 1 x 10(-7) M. The method was successfully applied to the determination of the analytes in a commercially available orange fruit juice.  相似文献   

2.
Chi Y  Dong Y  Chen G 《Analytical chemistry》2007,79(12):4521-4528
Electrochemiluminescence (ECL) has been accepted by the analytical chemist as a powerful tool for detection of many inorganic and organic compounds. Ru(bpy)3 2+ has been the most popular ECL system, and many investigations have been focused on the application based on the enhancement or inhibition of Ru(bpy)3 2+ ECL system. However, not much attention has been paid to the theoretical investigation of this ECL system, especially to the inhibiting mechanism for the Ru(bpy)3 2+ ECL system. In the present study, many of the inorganic and organic compounds with electrochemical oxidation activity were found to strongly inhibit Ru(bpy)3 2+ ECL. To explain these inhibited ECL phenomena, a new "electrochemical oxidation inhibiting" mechanism has been proposed via the establishment of a corresponding model. The effects of applied potential, uncompensated resistance, and concentration of inhibitor on the inhibited ECL derived from the model have been verified by experiments. The new ECL inhibition mechanism can be commonly used to explain many kinds of inhibited ECL presently observed, and it is envisioned to result in finding of more inhibitors of this type and establishment of new sensitive ECL detection methods for them.  相似文献   

3.
Choi HN  Cho SH  Lee WY 《Analytical chemistry》2003,75(16):4250-4256
Electrochemical behavior and electrogenerated chemiluminescence (ECL) of tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)3(2+)) immobilized in sol-gel-derived titania TiO2)-Nafion composite films coated on a glassy carbon electrode have been investigated. The electroactivity of Ru(bpy)3(2+) ion exchanged into the composite films and its ECL behavior were strongly dependent upon the amount of Nafion incorporated into the TiO2-Nafion composite films. The ECL sensor of Ru(bpy)32+ immobilized in a TiO2-Nafion composite with 50% Nafion content showed the maximum ECL intensities for both tripropylamine (TPA) and sodium oxalate in 0.05 M phosphate buffer solution at pH 7. Detection limits were 0.1 microM for TPA and 1.0 microM for oxalate (S/N = 3) with a linear range of 3 orders of magnitude in concentration. The present ECL sensor showed improved ECL sensitivity and long-term stability, as compared to the ECL sensors based on pure Nafion films. The present Ru(bpy)3(2+) ECL sensor based on TiO2-Nafion (50%) composite films was applied as an HPLC detector for the determination of erythromycin in human urine samples. The present Ru(bpy)3(2+) ECL sensor was stable in the mobile phase containing a high content of organic solvent (30%, v/v), in contrast to a pure Nafion-based Ru(bpy)3(2+) ECL sensor. The detection limit for erythromycin was 1.0 microM, with a linear range of 3 orders of magnitude in concentration.  相似文献   

4.
Zhang L  Dong S 《Analytical chemistry》2006,78(14):5119-5123
A novel electrogenerated chemiluminescence (ECL) sensor based on Ru(bpy)3(2+)-doped silica (RuDS) nanoparticles conjugated with a biopolymer chitosan membrane was developed. These uniform RuDS nanoparticles (approximately 40 nm) were prepared by a water-in-oil microemulsion method and were characterized by electrochemical and transmission electron microscopy technology. The Ru(bpy)3(2+)-doped interior maintained its high ECL efficiency, while the exterior nanosilica prevented the luminophor from leaching out into the aqueous solution due to the electrostatic interaction. This is the first attempt to branch out the application of RuDS nanoparticles into the field of ECL, and since a large amount of Ru(bpy)3(2+) was immobilized three-dimensionally on the electrode, the Ru(bpy)3(2+) ECL signal could be enhanced greatly, which finally resulted in the increased sensitivity. This sensor shows a detection limit of 2.8 nM for tripropylamine, which is 3 orders of magnitude lower than that observed at a Nafion-based ECL sensor. Furthermore, the present ECL sensor displays outstanding long-term stability.  相似文献   

5.
Shi L  Liu X  Li H  Xu G 《Analytical chemistry》2006,78(20):7330-7334
A sensitive electrochemiluminescent detection scheme by solid-phase extraction at Ru(bpy)3(2+)-modified ceramic carbon electrodes (CCEs) was developed. The as-prepared Ru(bpy)3(2+)-modified CCEs show much better long-term stability than other Nafion-based Ru(bpy)3(2+)-modified electrodes and enjoy the inherent advantages of CCEs. The log-log calibration plot for dioxopromethazine is linear from 1.0 x 10(-9) to 1.0 x 10(-4) mol L(-1) using the new detection scheme. The detection limit is 6.6 x 10(-10) mol L(-1) at a signal-to-noise ratio of 3. The new scheme improves the sensitivity by approximately 3 orders of magnitude, which is the most sensitive Ru(bpy)3(2+) ECL method. The scheme allows the detection of dioxopromethazine in a urine sample within 3 min. Since Ru(bpy)3(2+) ECL is a powerful technique for determination of numerous amine-containing substances, the new detection scheme holds great promise in measurement of free concentrations, investigation of protein-drug interactions and DNA-drug interactions, pharmaceutical analysis, and so on.  相似文献   

6.
Zu Y  Bard AJ 《Analytical chemistry》2001,73(16):3960-3964
We describe the effect of electrode surface hydrophobicity on the electrochemical behavior and electrogenerated chemiluminescence (ECL) of Ru(bpy)3(2+) (bpy = 2,2'-bipyridyl)/tripropylamine (TPrA) system. Gold and platinum electrodes were modified with different thiol monolayers. The hydrophobicity of the electrode surfaces changed with different terminal groups of the thiol molecules. The oxidation rate of TPrA was found to be much larger at the modified electrode with a more hydrophobic surface. The adsorption of neutral TPrA species on this kind of surface was assumed to contribute to the faster anodic kinetics. Due to the rapid generation of the highly reducing radical, TPrA., ECL intensity increased significantly at more hydrophobic electrodes. This electrode surface effect in the ECL analytical system allows one to improve the detection sensitivity at low concentrations of Ru(bpy)3(2+). The surfactant effect on the ECL process was also examined and discussed based on the change of electrode hydrophobicity by the adsorption of surfactant species.  相似文献   

7.
Zu Y  Bard AJ 《Analytical chemistry》2000,72(14):3223-3232
We describe the electrogenerated chemiluminescence (ECL) processes of the Ru(bpy)3(2+) (bpy = 2,2'-bipyridyl)/ tripropylamine (TPrA) system at glassy carbon, platinum, and gold electrodes. The electrochemical behavior of TPrA on different electrode materials and its influence on the ECL process are demonstrated. At glassy carbon electrodes, the direct oxidation of TPrA began at approximately 0.6 V vs SCE and exhibited a broad irreversible anodic peak. Two ECL waves were observed, one in the potential region more negative than 1.0 V vs SCE and one at more positive potentials. The first ECL process apparently occurs without the electrogeneration of Ru(bpy)3(3+), in contrast to that of the second ECL wave. At Pt and Au electrodes, however, the formation of surface oxides significantly blocked the direct oxidation of TPrA. An ECL wave below 1.0 V did not appear at Pt and was very weak at gold. The ECL peaks at potentials of 1.1-1.2 V were also much weaker than those observed at the glassy carbon electrode. These results showed that the direct oxidation of TPrA played an important role in the ECL processes. Therefore, the enhancement of the TPrA oxidation current might lead to an increase in the ECL intensity. Small amounts of halide species were found to inhibit the growth of surface oxides on Pt and gold electrodes and led to an obvious increase of TPrA oxidation current. The anodic dissolution of gold in halide-containing solution was also important in activating the gold electrode surface. The electrochemical catalytic effect of bromide further promoted the oxidation of TPrA. A halide effect on ECL at Pt and Au electrodes was also evident. The most effective enhancement of ECL was observed at Au electrode in a bromide-containing solution. This effect was also found in an commercial flow-through instrument (IGEN) and provided a simple way to improve the detection sensitivity at low concentrations of Ru(bpy)3(2+).  相似文献   

8.
Liu J  Yan J  Yang X  Wang E 《Analytical chemistry》2003,75(14):3637-3642
The design and performance of a miniaturized chip-type tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)3(2+)] electrochemiluminescence (ECL) detection cell suitable for both capillary electrophoresis (CE) and flow injection (FI) analysis are described. The cell was fabricated from two pieces of glass (20 x 15 x 1.7 mm), and the 0.5-mm-diameter platinum disk was used as working electrode held at +1.15 V (vs silver wire quasi-reference), the stainless steel guide tubing as counter electrode, and the silver wire as quasi-reference electrode. The performance traits of the cell in both CE and FI modes were evaluated using tripropylamine, proline, and oxalate and compared favorably to those reported for CE and FI detection cells. The advantages of versatility, sensitivity, and accuracy make the device attractive for the routine analysis of amine-containing species or oxalate by CE and FI with Ru(bpy)3(2+) ECL detection.  相似文献   

9.
The application of thin films of the metallopolymer [Ru(bpy)2PVP10]2+ for the electrochemiluminescent (ECL) detection of oxalate in a flow injection analysis system is reported, where bpy is 2,2'-bipyridyl and PVP is poly(4-vinylpyridine). Immobilization of the ECL reagent means that it can be regenerated in situ, eliminating the need to constantly deliver it to the reaction zone. Electrochemically generated Ru3+ reacts with the analyte to form the excited-state [Ru2+]*, which luminesces at 610 nm. The reaction is optimal at low pH, where the layer is swollen and homogeneous charge transport through the layer is more facile. Unlike traditional approaches, we simultaneously monitor both the amperometric and luminescent response of the modified electrode. The precision of both signals is similar at approximately 2% (n = 10). However, the ECL response has a larger dynamic range extending from the low-micromolar to high-millimolar range and a lower limit of detection, approximately 0.2 microM or 4 pmol of oxalate injected. The ECL approach displays excellent selectivity for oxalate over a wide range of potential interferences including oxygen, amines, iron sulfate, ammonium nitrate, urea, and glucose. Ascorbic acid represents the most significant ECL interference. However, the signal observed for a 1 mM solution of ascorbic acid is still only 2.6% of the response observed for the injection of a similar concentration of oxalate.  相似文献   

10.
A new electrogenerated chemiluminescence detection method is investigated for use in detection in reversed-phase and reversed-phase ion-pair HPLC with Ru(bpy)(3)(2+) in the mobile phase. In this method, different concentrations of Ru(bpy)(3)(2+) are dissolved in the mobile phase and the HPLC column flushed with the mobile phase for 1 h until the column is saturated with Ru(bpy)(3)(2+). The separated analytes along with Ru(bpy)(3)(2+) pass through an optical-electrochemical flow cell which has a dual platinum electrode held at a potential of 1250 mV vs a Ag/AgCl reference electrode. On the surface of the electrode, Ru(bpy)(3)(2+) is oxidized to Ru(bpy)(3)(3+) which reacts with the analytes to emit light. The retention times, retention orders, detection limits, and linearity in working curves are compared to those obtained with the conventional postcolumn Ru(bpy)(3)(2+) addition method. The retention times for dansyl amino acids with Ru(bpy)(3)(2+) in the mobile phase are longer than those obtained with the postcolumn addition approach. This may be caused by π-to-π interactions between the aromatic groups of the dansyl derivatives and the bipyridyl groups of Ru(bpy)(3)(2+) in the Ru(bpy)(3)(2+)-saturated reversed-phase column. Similarly, oxalate is separated from urine and blood plasma samples by reversed-phase ion-pair HPLC. Plasma samples are obtained using ultrafiltration to remove proteins from whole blood. Retention times for oxalate with the two detection techniques are identical, and detection limits for these techniques are compared.  相似文献   

11.
This paper describes a new approach for sensing electrochemically active substrates in microfluidic systems. This two-electrode sensor relies on electrochemical detection at one electrode and electrogenerated chemiluminescent (ECL) reporting at the other. Each microfabricated indium tin oxide electrode is located in a separate microfluidic channel, but the channels are connected downstream of the electrodes to maintain a complete electrical circuit. Because of laminar flow, there is no bulk mixing of the fluids in the detecting and reporting channels. This approach allows the ECL reaction to be physically and chemically decoupled from the sensing channel of the device, which greatly expands the number of analytes that can be detected. However, because the cathode and anode are connected, electron-transfer processes occurring at the sensing electrode are electrically coupled to the ECL reaction. Charge balance permits the ECL light output to be quantitatively correlated to electrochemical reductions at the cathode. The system is used to detect Fe(CN)6(3-), Ru(NH3)6(3+), and benzyl viologen and report their presence via Ru(bpy)3(2+) (bpy = bipyridine) luminescence. Each different redox target initiates ECL at a unique potential bias related to its standard redox potential. The influence of the concentrations of Ru(bpy)3(2+) and the target analytes is discussed.  相似文献   

12.
The electrochemistry and electrogenerated chemiluminescence (ECL) of Ru(bpy)3(2+) (bpy = 2,2'-bipyridyl) were studied in the presence of the nonionic surfactants Triton X-100, Thesit, and Nonidet P40. The anodic oxidation of Ru(bpy)3(2+) produces ECL in the presence of tri-n-propylamine in both aqueous and surfactant solutions. Increases in both ECL efficiency (> or =8-fold) and duration of the ECL signal were observed in surfactant media. A shift to lower energies of the Ru(bpy)3(2+) ECL emission by approximately 8 nm was also observed. The one-electron oxidation of Ru(bpy)3(2+) to Ru(bpy)3(3t) occurs at + 1.03 V vs Ag/AgCl in aqueous buffered (0.2 M potassium phosphate) solution as found by square wave voltammetry. This potential did not shift in surfactant systems, indicating that the redshifts in ECL emission are due to stabilization of ligand pi* orbitals in the metal-to-ligand charge-transfer excited state. These results are consistent with hydrophobic interactions between Ru(bpy)3(2+) and the nonionic surfactants.  相似文献   

13.
Miao W  Bard AJ 《Analytical chemistry》2004,76(18):5379-5386
An ultrasensitive DNA hybridization detection method based on electrogenerated chemiluminescence (ECL) using polystyrene microspheres/beads (PSB) as the carrier of the ECL labels, namely, tris(2,2'-bipyridyl)ruthenium(II) tetrakis(pentafluorophenyl)borate (Ru(bpy)3[B(C6F5)4]2), is reported. Probe single-stranded DNA (p-ssDNA) was attached to the surface of magnetic beads (MB) and hybridized with target-ssDNA (t-ssDNA) with immobilized PSB containing a large number of water insoluble Ru(bpy)3[B(C6F5)4]2 species (approximately 7.5 x 10(9) molecules/bead). With this approach a large amplification factor of Ru(bpy)3[B(C6F5)4]2 molecules for each t-ssDNA can be achieved, when each PSB is attached to a limited number of t-ssDNA. The p-ssDNA-MB <--> t-ssDNA-PSB/Ru(bpy)3(2+) conjugates formed were magnetically separated from the reaction media and dissolved in MeCN containing tri-n-propylamine (TPrA) as an ECL coreactant. ECL was produced with a potential scan from 0 to 3.0 V versus Ag/Ag+, and the integrated ECL intensity was found to be linearly proportional to the t-ssDNA concentration in a range of 1.0 fM to 10 nM under optimized conditions. ECL signals associated with two base pair mismatched ssDNA and noncomplementary ssDNA can be distinguished well from the ECL signal related to the complementary DNA hybridization. A Poisson distribution is followed when a large number of MB reacts with PSB, and the minimum number of 1.0- and 2.8-microm diameter MB required to bind and magnetically separate a single 10-microm diameter PSB from the reaction solution was estimated to be three and one, respectively. The principle described in this paper could be also applied to many other ECL analyses, such as immunoassays.  相似文献   

14.
The effects of metal ions on the electrochemiluminescence (ECL) properties of (bpy)2Ru(AZA-bpy) (bpy = 2,2'-bipyridine; AZA-bpy = 4-(N-aza-18-crown-6-methyl-2,2'-bipyridine) have been investigated. The electrochemistry, photophysics and ECL of Ru(bpy)3(2+) in the presence of Pb2+, Hg2+, Cu2+, and K+ are reported. The anodic oxidation of Ru(bpy)3(2+) produces ECL in the presence of tri-n-propylamine (TPrA) in 50:50 (v/v) CH3CN:H2O solution. Increases in ECL efficiency (photons generated per redox event) up to 20-fold that depend on both the concentration and nature of the metal ion have been observed, making this an interesting system for electrochemiluminescence metal ion sensing.  相似文献   

15.
The unique electrochemiluminescence (ECL) behavior of tris(bipyridine) ruthenium(II) (Ru(bpy)32+) immobilized in a gold/Nafion/Ru(bpy)32+ composite material was investigated. In this composite, the Ru(bpy)32+ ECL was found mainly occurred at 0-0.4 V during the cathodic scan process and the ECL peak was at about 0.1 V, which was quite different to the reported Ru(bpy)32+ ECL. Similar to the generally observed Ru(bpy)32+ ECL, the present ECL also could be enhanced by tri-n-propylamine (TPA). It is also unique that in the presence of TPA, another ECL peak at about 0.38 V occurred. These two ECL peak potentials all could be used as characteristic potential for the ECL determination of TPA.  相似文献   

16.
Sun X  Du Y  Dong S  Wang E 《Analytical chemistry》2005,77(24):8166-8169
A novel method for effective immobilization of Ru(bpy)3(2+) on an electrode surface is developed. The whole process involves two steps: the electrostatic interactions between citrate-capped gold nanoparticles (AuNPs) and Ru(bpy)3Cl2 in aqueous medium were used to fabricate Ru(bpy)(3)2+-AuNP aggregates (Ru-AuNPs) first, and then the Au-S interactions between as-formed Ru-AuNPs and sulfhydryl groups were used to effectively immobilize the Ru-AuNPs on a sulfhydryl-derivated indium tin oxide (ITO) electrode surface. As-prepared ITO electrode shows excellent stability, and the ECL active species Ru(bpy)3(2+) contained therein exhibit excellent ECL behaviors.  相似文献   

17.
The voltammetry and electrogenerated chemiluminescence (ECL) of tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)3 2+) ion-exchanged in Nafion and Nafion-silica composite materials have been investigated. The major goal of this work was to investigate and develop new materials and immobilization approaches for the fabrication of ECL-based sensors with improved reactivity and long-term stability. Nation-silica composite materials with varying contents of Nation (53-100 wt% relative to silica) were prepared via the two-step acid/base hydrolysis and condensation of tetramethoxysilane. The Nafion doped sols were spin cast on glassy carbon electrodes, dried, and then ion-exchanged with Ru(bpy)3 2+. The shapes of the cyclic voltammetric curves and the amount of Ru(bpy)3 2+ exchanged into the films strongly depends on the amount of Nafion incorporated into the hybrid sol. Nafion-silica films with a low content of Nafion ion-exchanged less Ru(bpy)3 2+ and exhibited tail-shaped voltammetry at 100 mV/s. The ECL of immobilized Ru(bpy)3 2+ in the presence of either tripropylamine or sodium oxalate in pH 5 acetate buffer was also strongly dependent on the amount of Nafion introduced into the composite with greater ECL observed for the Nafion-silica films relative to pure Nafion.  相似文献   

18.
The effects of nonionic surfactant chain length on the properties of tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)3(2+) where bpy = 2,2'-bipyridine) electrochemiluminescence (ECL) have been investigated. The electrochemistry, photophysics, and ECL of Ru(bpy)3(2+) in the presence of a series of nonionic surfactants are reported (Triton X-100, 114, 165, 405, 305, and 705-70). These surfactants differ in the number of poly(ethylene oxide) units incorporated into the surfactant molecule. The anodic oxidation of Ru(bpy)3(2+) produces ECL in the presence of tri-n-propylamine (TPrA) in aqueous surfactant solution. Increases in ECL efficiency (> or = 5-fold) and TPrA oxidation current (> or = 2-fold) have been observed in surfactant media. Slight decreases in ECL intensity are observed as the chain length of the nonionic surfactant increases. The data supports adsorption of surfactant on the electrode surface, thus facilitating TPrA and Ru(bpy)3(2+) oxidation and leading to higher ECL efficiencies.  相似文献   

19.
Sun X  Du Y  Zhang L  Dong S  Wang E 《Analytical chemistry》2007,79(6):2588-2592
In this correspondence, we report on the first preparation of novel, robust Ru(bpy)32+-containing supramolecular microstructures via a solution-based self-assembly strategy, carried out by directly mixing H2PtCl6 and Ru(bpy)3Cl2 aqueous solutions at room temperature. It reveals that both the molar ratio and concentration of reactants have a heavy influence on the morphologies of such microstructures. The electrochemical behavior of the Ru(bpy)32+ components contained in the solid film of the microstructures formed on the electrode surface is also studied and found to exhibit a diffusion-controlled voltammetric feature. Most importantly, such microstructures exhibit excellent electrochemiluminescence (ECL) behaviors and therefore hold great promise as new luminescent materials for solid-state ECL detection in capillary electrophoresis (CE) or CE microchip.  相似文献   

20.
The electrogenerated chemiluminescence (ECL) of Ru(bpy)3 2+ and tripropylamine, tributylamine, triethylamine, trimethylamine, or sodium oxalate encapsulated within sol-gel-derived silica monoliths have been investigated using an immobilized ultramicroelectrode assembly. The major purpose of this study was to investigate the role of the reductant on the magnitude and stability of the ECL in this solid host matrix. For gel-entrapped Ru(bpy)3 2-/tertiary amines, the shape and intensity of the ECL-potential curves were highly dependent on scan rate. At 10 mV/s, the ECL intensity was ca. 6-fold higher relative to that observed at 500 mV/s. When the ECL acquired at low scan rates was normalized by that obtained in solution under similar conditions, a value of 0.03-0.06 was obtained. In direct contrast, the ECL of the Ru(bpy)3 2+-oxalate system showed little dependence on scan rate, and the ECL was ca. 65-75% of that measured in solution. These differences can be attributed to differences in rotational and translational mobility between the reductants (amines vs oxalate) trapped in this porous solid host For both systems, the ECL was found to be stable upon continuous oxidation or upon drying the gels in a high-humidity environment for over 10 days.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号