首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 968 毫秒
1.
PURPOSE: To determine if suprarenal placement of inferior vena cava (IVC) filters is associated with renal dysfunction or other complications. MATERIALS AND METHODS: Case files of all patients with suprarenal vena caval filter placement since 1985 were reviewed for clinical and biochemical evidence of renal dysfunction and renal vein thrombosis. The occurrence of associated complications, including IVC occlusion, filter fracture, device migration, and recurrence of pulmonary embolism was also recorded. RESULTS: Twenty-two (2.9%) of 764 IVC filters were implanted above the renal veins: titanium Greenfield filter modified hook (TGF-MH) (n = 16), LGM type I (n = 2), LGM type II (n = 2), and Bird's Nest (BN) type I (n = 2). Reasons for suprarenal filter placement included thrombus to the level of the renal veins (n = 9), failure or poor position of the infrarenal filter (n = 6), pregnancy or intent of pregnancy (n = 4), and the malpositioning of BN filters above the renal veins (n = 2). A single patient demonstrated evidence of transient renal dysfunction. Pulmonary embolus was found at autopsy in one patient. Abdominal radiographs were obtained at follow-up of 18 patients and demonstrated a 2 cm or more migration of the filter in five patients (27.7%). This rate of migration was significantly different from the 3% migration rate reported by the authors' institution in the follow-up of 320 infrarenal IVC filters. There was one filter fracture (5.5%.) and penetration of the IVC occurred in one patient (5.5%). CONCLUSION: Follow-up indicates suprarenal IVC filter placement is safe, and no evidence of permanent renal dysfunction after placement was found. Filter migration was the most frequent complication, but no clinical sequelae were noted with these patients.  相似文献   

2.
PURPOSE: The change in inferior vena caval (IVC) filter position at follow-up relative to the filter position at implantation has been used as a criterion for evaluation and comparison of these devices. Perceived changes in filter position may be due to respiratory movement and/or changes in parallax between the initial and follow-up imaging studies. In this study the authors evaluated and attempted to quantify the effects of respiratory movement and parallax. PATIENTS AND METHODS: After placement of an IVC filter, radiographs of the abdomen were taken at maximum inspiration and maximum expiration in 30 patients. The effect of parallax on apparent filter movement was studied by using a phantom. RESULTS: The average filter movement on inspiration/expiration radiographs (corrected for magnification) was 3.6 mm +/- 2.2. An 8.5-mm maximal change secondary to parallax was seen in the phantom study. CONCLUSION: When follow-up images are obtained, efforts should be made to closely reproduce patient positioning and patient respiration to reduce errors in the interpretation of filter migration.  相似文献   

3.
PURPOSE: A comparison of tilting, caval coverage, asymmetry, and insertion problems with the over-the-wire stainless-steel and titanium versions of the Greenfield filter. MATERIALS AND METHODS: The study compared 104 stainless-steel and 141 titanium Greenfield inferior vena cava (IVC) filter insertions. The angle the sheath and deployed filter made relative to the cava, as well as filter strut distribution, were determined from spot films. The proportionate caval coverage was computed from the cavogram (anteroposterior projection). Mean filter tilts, subgrouped by insertion site, and caval coverage were compared with the Student t test, whereas strut patterns were analyzed with a contingency table. RESULTS: The filter caval and sheath caval angles correlated. The filter caval angles varied with insertion site, but were lowest with a right jugular approach. Caval coverage was identical with both designs. The stainless-steel version resulted in a more uniform distribution of struts in comparison with the titanium version. The incidence of insertion problems was not significantly different between the filter types. CONCLUSIONS: While IVC filter tilting was not improved with the newer design, the pattern of struts was more uniformly symmetric with the stainless-steel device. The right jugular insertion site was associated with the lowest filter caval angles and the most symmetric pattern of struts.  相似文献   

4.
OBJECTIVE: We evaluated findings on contrast-enhanced abdominal CT scans that suggest obstruction of the superior vena cava, brachiocephalic vein, or subclavian vein. SUBJECTS AND METHODS: We conducted a retrospective review of 22 patients with superior vena caval, brachiocephalic vein, or subclavian vein obstruction and analyzed the upper abdominal images on a chest CT scan or an abdominal CT scan. We assessed collateral vessels in the upper abdomen to answer the following question: Did enhancement approach undiluted IV contrast or were there other findings? In the second part of our study, we conducted a prospective review of abdominal CT scans of 200 patients without known mediastinal disease or known upper extremity venous occlusion to determine the frequency of abnormal enhancement of these vessels in a healthy population. RESULTS: The groups of collateral vessels revealed on abdominal CT scans were azygos or hemiazygos veins, internal mammary veins, lateral thoracic and superficial thoracoabdominal veins, vertebral venous plexus veins, and small mediastinal collateral veins. In the retrospective series, one patient had focal enhancement of the liver and early inferior vena caval enhancement due to collateral vessels. In the prospective series, abdominal CT scans of two patients (1%) revealed dense undiluted enhancement of one or more groups of collateral vessels: One patient had an ipsilateral pacemaker, and the other patient had an anterior neck phlegmon to the upper mediastinum. Both conditions may have been factors in the revealing of the collateral vessels. Two other patients (1%) in the prospective series had mild to moderate vessel enhancement that was less than that from undiluted contrast material. In one of these patients, the enhancement was related to abdominal wall hyperemia after surgery. In the other patient, enhancement may have been the result of ipsilateral axillary nodes. CONCLUSION: On upper abdominal CT scans, dense undiluted contrast material in the collateral vessel groups that we studied suggests possible obstruction of the superior vena cava, brachiocephalic vein, or subclavian vein.  相似文献   

5.
PURPOSE: In vitro and in vivo investigations were performed to evaluate the Irie retrievable inferior vena caval (IVC) filter. MATERIALS AND METHODS: The clot capturing performance of the Irie and five other IVC filters were assessed in both horizontal and vertical orientations within a pulsed-flow circuit with 240 clot challenges for each filter. Subjective comparisons of the flow disturbance characteristics of the Irie and three other filters were also performed. In vivo studies consisted of 13 Irie filter insertions and eight attempted retrievals in 11 pigs. Histologic evaluation of the IVC was performed with the Irie filter in situ and following retrieval. RESULTS: In vitro testing demonstrated the clot capturing capability and flow disturbance characteristics of the Irie filter to be similar to those of other IVC filters. Filter deployment problems occurred during three of the 13 insertions. Six of the eight retrieval procedures were successful; four filters were retrieved 1 month after insertion. Follow-up cavography demonstrated two tilted filters and three caval perforations. CONCLUSION: The performance of the Irie filter is similar to that of other currently available IVC filters. The filter can be retrieved after neointimal incorporation of the struts into the IVC wall.  相似文献   

6.
PURPOSE: To review delayed and guidewire-induced morbidity associated with vena cava filters. METHODS: The records from the Johns Hopkins Hospital, a tertiary care referral center, of all patients who had vena cava filter complications from August 1993 through July 1996 were retrospectively reviewed. RESULTS: Five patients had filter migration or ensnarement with a guidewire. One patient had delayed extrusion of a filter strut into the duodenum. Four patients had filters ensnared by guidewires, including one during initial filter placement and one several years after placement. CONCLUSIONS: Delayed complications of vena cava filters should be considered whenever unusual patient signs or symptoms cannot be easily explained, even in the absence of a history of filter placement. To prevent guidewire ensnarement of filters, simple techniques should modify endovascular procedures when vena cava filters are present.  相似文献   

7.
Vena cava duplex imaging before caval interruption   总被引:1,自引:0,他引:1  
PURPOSE: Venacavograms are routinely obtained before vena cava filter placement to evaluate cava size, patency, and the presence of thrombus or venous anomalies. The objective of this study was to determine the ability of duplex ultrasonography to adequately evaluate the inferior vena cava (IVC) for size, patency, and the presence of thrombus before Greenfield filter (GF) insertion. METHODS: Duplex ultrasonographic scans were performed in 40 patients who had documented lower-extremity deep venous thrombosis diagnosed by duplex scan before GF placement. The infrarenal transverse and anteroposterior diameters of the IVC were measured, and the entire IVC was imaged for patency and the presence of thrombus or anomalies. Preoperative venacavograms were not obtained in any patients who had GFs placed in the operating room, but was performed during surgery during filter insertion. An additional 26 patients who had deep venous thrombosis and did not have caval interruption underwent IVC duplex to determine the patency and proximal extent of venous thrombosis. RESULTS: The indications for GF placement were contraindication to anticoagulation in 72.5% (29 patients); five filters were placed prophylactically; three for failure of anticoagulation; two after a complication of anticoagulation; and one before pulmonary embolectomy. The filters were placed in the operating room by surgeons in 82.5% of patients, with the remainder inserted in an angiography suite by an interventional radiologist. The ability of duplex to measure a transverse diameter of 26 mm or less had a sensitivity of 97.5%, positive predictive value of 100%, and overall accuracy of 97.5% using venacavography as the standard. Measurements of IVC diameter by duplex correlated with those based on venacavograms (r = 0.766; p < 0.001). Of the entire group of 66 IVC duplex examinations, one (1.5%) was incomplete because of technical limitations. IVC thrombus was noted by duplex in two patients who underwent GF insertion, which was confirmed with venacavography. No IVC anomalies were noted by duplex scans or venacavograms. CONCLUSION: Duplex ultrasonography is a useful and accurate method for assessment of the IVC before vena cava filter placement.  相似文献   

8.
STUDY DESIGN: Case report. OBJECTIVE: To highlight the evaluation of a patient with low back pain after an incidental radiographic finding clouded routine management. SUMMARY OF BACKGROUND DATA: Greenfield filters have been used for 20 years with good results. Complications have been seen and documented, but the natural history of filter placement in young patients is not fully appreciated. A prong from a Greenfield filter embedded within a vertebral body has been reported once as an incidental finding in a patient undergoing prophylactic monitoring for recurrence of tumor. METHODS: A 31-year-old woman had a pulmonary embolus after surgery for a benign adnexal mass. A bleeding complication occurred after systemic anticoagulation, and a vena caval filter was placed to limit the possibility of further emboli. The patient was referred to the orthopedic clinic 5 years later with low back pain and an unusual finding on computer tomographic scan: One prong of the filter was embedded within a vertebral body. RESULTS: A bone scan was obtained to evaluate the status of bone activity around the prong. Bone reaction was not evident. Conservative management of her low back pain was instituted, and after 2 years, the patient remains asymptomatic. CONCLUSION: The overall use of vena caval filters has produced favorable results, although numerous complications have been reported. All long-term sequelae have not been completely identified.  相似文献   

9.
Non-traumatic duodenocaval fistulae are rare, but may be the source of massive gastrointestional bleeding with associated fever and sepsis. These fistulae result from penetrating duodenal peptic ulcers or right nephrectomy and subsequent radiation to the upper abdomen. The outcome depends on early diagnosis and surgery before a potentially fatal hemorrhage occurs. The therapy of choice includes closure of the fistula and repair of the duodenum and inferior vena cava. We describe the seventh case with radiogenic duodenal ulcer. Gastrointestinal bleeding occurred 10 years after radical nephrectomy and radiation (60 Gy). The patient survived following partial pancreatoduodenectomy (Whipple).  相似文献   

10.
The aim of this study was to evaluate the clinical efficacy, mechanical stability, and safety of the Simon nitinol inferior vena cava filter (SNF). The SNF was inserted in 114 consecutive patients at two institutions for prophylaxis of pulmonary embolism (PE). Clinical follow-up data were obtained retrospectively on all patients, and 38 patients underwent a dedicated radiologic follow-up protocol consisting of abdominal radiography, Doppler sonography, and CT. There was no immediate complication following filter insertion. Fifty patients died, on average, 5.6 (1-23) months after filter insertion, and 64 patients were alive, on average, 27 (3-62) months after filter insertion. Recurrent pulmonary embolism was documented in 5 patients (4.4 %) but originated distal to the filter in 1 patient. Deep venous thrombosis (DVT) was documented in 5.3 %, thrombosis at the access site in 3.5 %, and thrombosis of the inferior vena cava in 3.5 %. The rate of thromboembolic complications was similar in patients who did receive long-term anticoagulation and in those who did not. Radiologic follow-up showed no filter migration after, on average, 32 (5-62) months. A CT examination showed that struts of the SNF had penetrated the vena cava in 95 %, and were in contact with adjacent organs in 76 %; however, there were no clinical symptoms attributable to the filter. Filters were in an eccentric position in 63 % and partial filter disruption was found in 16 %; however, this did not affect filter function. The rate of recurrent pulmonary embolism after insertion of the SNF is 2.4 % per patient per year. Regardless of long-term anticoagulation, the rate of caval thrombosis is acceptably low. Except for occasional access-site thrombosis, no other filter-related morbidity was observed.  相似文献   

11.
PURPOSE: To look at the benefits and complications of different vena caval filters inserted prophylactically. Three temporarily implantable caval filter systems were used in 67 patients. MATERIALS AND METHODS: Twelve Cook filters (six transjugular, six transfemoral), 11 Angiocor filters (one transjugular, 10 transbrachial), and 44 Antheor filters (three transjugular, four transfemoral, 37 transbrachial) were successfully implanted. In known iliac vein or caval thrombosis, the prophylactic filters were placed during thrombolytic therapy in 46 cases, surgery in 17 cases, thrombosis in pregnancy in three cases, and high-dose heparinization without lysis in one case. RESULTS: One patient had a fatal pulmonary embolism during treatment; seven thrombi were detected in the filter. Other complications were caused either by the underlying therapy alone (one fatal outcome of abdominal aorta aneurysmal surgery, two cases of cerebral hemorrhage, two cases of retroperitoneal hematomas, two cases of streptokinase fever reactions, one compartment syndrome, two cases of macrohematuria), by the combination of therapy and caval filter implantation (three cases of groin hematomas, three cases of arm hematomas), or by filter implantation alone (two cases of subclavian vein thrombosis, one catheter infection, one dislocation, one air embolism, one basket rupture). The bleeding complications were related to the aggressive thrombolytic therapy and would have occurred without filter implantation. CONCLUSION: Because temporary caval filters have no long-term complications per se, their use seems sensible as long as there are stringent indications, including the presence of iliac vein or caval thrombosis and risk of thrombus mobilization. The Antheor filter system was the most convenient system for implantation.  相似文献   

12.
BACKGROUND: Vascular complications remain an important cause of postoperative morbidity in liver transplant patients. Herein, we present an unusual case of nonanastomotic inferior vena cava (IVC) stenosis in a patient with a "piggyback" caval anastomosis. METHODS: A 59-year-old woman underwent liver transplantation using a piggyback IVC anastomosis. Her postoperative course was complicated by IVC thrombosis. Catheter-directed thrombolysis, followed by balloon angioplasty and intravascular stent placement, was used to recanalize the IVC and treat a severe retrohepatic IVC stenosis. RESULTS: After 46 hr of catheter-directed urokinase infusion, there was clot lysis and identification of a severe stenosis in the retrohepatic IVC. The lesion was extremely resistant to balloon dilatation alone and a 22-mm-diameter intravascular stent was placed. Simultaneous dilatation of three high-pressure balloons was necessary for maximal stent expansion. The patient remains asymptomatic with no evidence of IVC compromise through 20 months of follow-up. CONCLUSIONS: IVC stenosis and thrombosis after liver transplantation may be treated favorably in some patients using catheter-directed thrombolytic therapy followed by balloon dilatation and/or stent placement.  相似文献   

13.
Although hot spots on hepatic scintigrams have been reported in association with superior and inferior vena caval obstruction, these studies were not clinically correlated, and are hampered by the poor resolution of earlier scintillation cameras. In this report, a modern scintillation camera was used to study the formation of hot spots associated with superior and inferior vena caval obstruction. Moreover, radionuclide cavography was performed in 70 patients with superior vena caval (SVC) obstruction and in 95 patients with inferior vena caval (IVC) obstruction. As a result, 13 cases of hot spots in the liver were observed. In cases of SVC obstruction, hot spots were seen in the quadrate lobe, the medial segment, and the bare area of the liver. In IVC obstruction, a hot spot was seen in the quadrate lobe in all cases. In rare instances, in cases of both SVC and IVC obstruction, a hot spot was seen in the wide area. For these hot spots to develop, it appears necessary to have systemic-portal venous blood flow through the internal thoracic vein and the paraumbilical vein.  相似文献   

14.
Thrombosis of the access site and occlusion of the inferior vena cava after placement of an inferior vena caval filter are known complications of caval interruption. 30 patients were evaluated with colour-coded Doppler sonography 4 to 66 months (average 2.5 years) after percutaneous placement of either a Günther filter, a Bird's Nest filter or a Simon-Nitinol filter. One right internal jugular vein had post-thrombotic alterations. One inferior vena cava was found to be occluded 15 months after Simon-Nitinol filter placement. The long-term occlusion rates of access site and inferior vena cava after percutaneous filter introduction are low. These two factors need not be considered if implantation of a caval filter is contemplated.  相似文献   

15.
PURPOSE: This study was undertaken to determine the clinical outcomes for patients with Greenfield filters placed in the suprarenal (SR) inferior vena cava (IVC). METHODS: We collected data prospectively from annual follow-up evaluations of patients with filters. Patients underwent venous color-flow duplex examinations of the IVC and lower extremities, abdominal radiographs, and physical assessment. The outcomes for those patients with filters in the SR IVC were compared with the outcomes previously reported and with the outcomes for patients with filters in the infrarenal cava. RESULTS: SR placement accounted for 7.6% (148/1932) of all filter placements. Follow-up data were available for 73 placements, or 49%. No cases of renal dysfunction were related to filter placement. The rate of recurrent pulmonary embolism (PE) was 8%, and the rate of long-term caval occlusion was 2.7%. These rates did not differ statistically from the rates for patients with infrarenal filters (P > .05). Male patients tended to be older by 15 years, to have more recurrent PE, and to experience more filter migration (6 vs 2 mm). Failure of SR filters to prevent PE was associated statistically with the primary indication for placement. Recurrent PE was the indication in 5 of 6 patients who sustained PE after SR filter placement (P = .007). Filter limb fracture was seen only with the stainless-steel Greenfield filter. CONCLUSION: Greenfield filters placed above the renal vein provide protection from PE with a minimal risk of occlusion. Twenty-five years of experience with Greenfield filters shows that they are safe and effective both in young female patients of child-bearing potential and in all patients with appropriate indications for SR placement.  相似文献   

16.
BACKGROUND: The efficacy and safety of vena caval filters in the prevention of pulmonary embolism in patients with proximal deep-vein thrombosis is still a matter of debate. METHODS: Using a two-by-two factorial design, we randomly assigned 400 patients with proximal deep-vein thrombosis who were at risk for pulmonary embolism to receive a vena caval filter (200 patients) or no filter (200 patients), and to receive low-molecular-weight heparin (enoxaparin, 195 patients) or unfractionated heparin (205 patients). The rates of recurrent venous thromboembolism, death, and major bleeding were analyzed at day 12 and at two years. RESULTS: At day 12, two patients assigned to receive filters (1.1 percent), as compared with nine patients assigned to receive no filters (4.8 percent), had had symptomatic or asymptomatic pulmonary embolism (odds ratio, 0.22; 95 percent confidence interval, 0.05 to 0.90). At two years, 37 patients assigned to the filter group (20.8 percent), as compared with 21 patients assigned to the no-filter group (11.6 percent), had had recurrent deep-vein thrombosis (odds ratio, 1.87; 95 percent confidence interval, 1.10 to 3.20). There were no significant differences in mortality or the other outcomes. At day 12, three patients assigned to low-molecular-weight heparin (1.6 percent), as compared with eight patients assigned to unfractionated heparin (4.2 percent), had had symptomatic or asymptomatic pulmonary embolism (odds ratio, 0.38; 95 percent confidence interval, 0.10 to 1.38). CONCLUSIONS: In high-risk patients with proximal deep-vein thrombosis, the initial beneficial effect of vena caval filters for the prevention of pulmonary embolism was counterbalanced by an excess of recurrent deep-vein thrombosis, without any difference in mortality. Our data also confirmed that low-molecular-weight heparin was as effective and safe as unfractionated heparin for the prevention of pulmonary embolism.  相似文献   

17.
BACKGROUND: To investigate the role and impact of multiplane transesophageal echocardiography during thrombectomy in the inferior vena cava or the right atrium. EXPERIMENTAL DESIGN: Retrospective. SETTING: A university hospital. PARTICIPANTS: Four patients who underwent removal of tumor thrombus in the inferior vena cava (IVC) or the right atrium. INTERVENTIONS: The medical records of 4 patients and videotapes of these intraoperative transesophageal echocardiography examinations were reviewed. RESULTS: Before thrombectomy, multiplane transesophageal echocardiography (MTEE) provided excellent IVC long axis view, which offered precise recognition of the cephalic extent of tumor, extent of caval occlusion, characterization of the tumor head. During surgery, MTEE could provide continuous monitoring of cardiac function, cardiac volume, and pulmonary embolism. Moreover, MTEE could provide the useful images of a cannula or the caval occlusion balloon catheter, which facilitated removal of neoplasm extending into the IVC. CONCLUSIONS: We presented four surgical cases, in which the removal of the tumor extended into the inferior vena cava or the right atrium using MTEE. MTEE could provide valuable information such as excellent images of the tumor, cardiac function, the position of a cannula or the caval occlusion balloon catheter. These findings could improve the anesthetic management of the patients, as well as the surgical approach and technical maneuvers, and facilitate removal of neoplasm into the IVC.  相似文献   

18.
PURPOSE: Invasion of the inferior vena cava (IVC) by tumor is generally considered a criterion of unresectability. This study was designed to review the outcomes of a strategy of aggressive resection of the vena cava to achieve complete tumor resection coupled with prosthetic graft placement to re-establish caval flow. METHODS: Retrospective review of patients treated at a university referral center. Ten patients (mean age 54; eight females, two males) underwent tumor resection that involved circumferential resection of the IVC and immediate prosthetic replacement with ringed polytetrafluoroethylene (PTFE) grafts ranging in diameter from 12 to 16 mm. RESULTS: Seven patients had replacement of the infrarenal IVC, two of their suprarenal IVC, and one had reconstruction of the IVC bifurcation. Four of the 10 patients received preoperative chemotherapy, and none received radiotherapy. The most common (7/10) pathologic diagnosis was leiomyosarcoma arising from the IVC or retroperitoneum. Additional diagnoses included teratoma (one), renal cell carcinoma (one), and adrenal lymphoma (one). There were no perioperative deaths, and one complication (prolonged ileus) occurred. Mean length of stay was 8.1 days. Anticoagulation was not routinely used intraoperatively or postoperatively. Follow-up (mean duration = 19 months) demonstrated that survival was 80% (8/10) and 88% (7/8) of patients were free of venous obstructive symptoms. CONCLUSION: Resection of the IVC with prosthetic reconstruction allows for complete tumor resection and provides durable relief from symptoms of venous obstruction.  相似文献   

19.
OBJECTIVE: Our goal was to describe attenuation differences bordered by a straight line in the right hepatic lobe on enhanced CT in patients with right adrenal tumors and to discuss the cause of this appearance. MATERIALS AND METHODS: Three patients showing attenuation differences bordered by a straight line were discovered in the CT files of 26 cases of right adrenal tumor over 3 cm in diameter. All CT scans were examined by incremental dynamic study. RESULTS: Two patients had large zone of hyperattenuation in the right lobe bordered with a straight line intersecting both anterior branches of the right portal vein and the inferior vena cava (IVC). A third patient and one of the two patients mentioned already had zones of relative hyper- and hypoattenuation in the medial portion of the posterior hepatic segment, respectively. All three patients had large right adrenal tumors, which severely compressed the right hepatic vein near its confluence with the IVC and/or the IVC in or below its intrahepatic portion. The distribution of attenuation differences was similar to the hyperattenuation at CT arteriography or perfusion defect at CT arterial portography under temporary balloon occlusion of the right hepatic vein and inferior right hepatic vein, respectively. CONCLUSION: Straight-bordered attenuation differences within the right hepatic lobe at dynamic CT can be caused by compression of the right hepatic vein by large right adrenal tumors.  相似文献   

20.
We report herein the case of a 78-year-old man in whom an aortocaval fistula caused by spontaneous rupture of an abdominal aortic aneurysm (AAA) was successfully treated by a unique surgical technique. The aortocaval fistula had been revealed by an aortography after the patient presented with high-output heart failure. During the operation, massive bleeding from the fistula was evident. The fistula measured 2 cm in diameter, and was located between the right posterior wall of the AAA and the inferior vena cava (IVC). Direct suturing of the defect in the IVC failed to close the fistula because the tissue around it would not hold together due to degeneration. However, the bleeding was finally able to be controlled by plugging the fistula with isolated and properly trimmed omentum packed within the excluded aneurysmal sac. Unfortunately, the patient died due to respiratory failure on the 201st postoperative day. A pathological autopsy revealed that the aortocaval fistula had been closed by fibrous tissue and that the IVC was patent. Although such a drastic operative measure to repair an aortocaval fistula has never before been reported, it could be an alternative when direct closure proves unsuccessful.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏