首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This study is to experimentally investigate the heat transfer enhancement by delta winglet vortex generators in air cooling of a staggered array of rectangular electronic modules. The winglet vortex generators are placed in front of 3 × 5 modules with 20° attack angle. Each module has dimensions of 1.8 × 5.4 × 0.6 mm and each one generates heat at 2.5 W. The adiabatic heat transfer coefficients, the thermal wake functions including their correlations for the modules with and without the vortex generators are considered at different values of Reynolds number and the module density. It could be seen that the vortex generators could enhance the adiabatic heat transfer coefficients, reduce the thermal wake functions and the module temperatures significantly. The module temperatures predicted by the superposition of the convective effect due to the module heat generations and the module thermal wakes are fitted very well with the measured data.  相似文献   

2.
《Applied Thermal Engineering》2005,25(11-12):1684-1696
Local heat transfer coefficients were measured on fin-tube heat exchanger with winglets using a single heater of 2 inch diameter and five different positions of winglet type vortex generators. The measurements were made at Reynolds number about 2250. Flow losses were determined by measuring the static pressure drop in the system. Results showed a substantial increase in the heat transfer with winglet type vortex generators. It has been observed that average Nusselt number increases by about 46% while the local heat transfer coefficient improves by several times as compared to plain fin-tube heat exchanger. The maximum improvement is observed in the re-circulation zone. The best location of the winglets was with ΔX = 0.5D and ΔY = 0.5D. The increase in pressure drop for the existing situation was of the order of 18%.  相似文献   

3.
This paper presents the influences of main parameters of longitudinal vortex generator (LVG) on the heat transfer enhancement and flow resistance in a rectangular channel. The parameters include the location of LVG in the channel, geometric sizes and shape of LVG. Numerical results show that the overall Nusselt number of channel will decrease with the LVGs’ location away from the inlet of the channel, and decrease too with the space between the LVG pair decreased. The location of LVG has no significant influence on the total pressure drop of channel. With the area of LVG increased, the average Nusselt number and the flow loss penalty of channel, especially when β = 45° will increase. With the area of LVG fixed, increasing the length of rectangular winglet pair vortex generator will bring about more heat transfer enhancement and less flow loss increase than that increasing the height of rectangular winglet pair vortex generator. With the same area of LVG, delta winglet pair is more effective than rectangular winglet pair on heat transfer enhancement of channel, and delta winglet pair-b is more effective than delta winglet pair-a. Delta winglet pair-a results in a higher pressure drop, the next is rectangular winglet pair and the last is delta winglet-b. The increase of heat transfer enhancement is always accompanied with the decrease of field synergy angle between the velocity and temperature gradient when the parameters of LVG are changed. This confirms again that the field synergy is the fundamental mechanism of heat transfer by longitudinal vortex. The laminar heat transfer of the channel with punched delta winglet pair is experimentally and numerically studied in the present paper. The numerical result for the average heat transfer coefficient of the channel agrees well with the experimental result, indicating the reliability of the present numerical predictions.  相似文献   

4.
The article presents an experimental investigation on thermal performance enhancement in a constant heat-fluxed square duct fitted with combined twisted-tape and winglet vortex generators. The experiments are carried out for the airflow rate through the tested square duct fitted with both the vortex generators for Reynolds number from 4000 to 30,000. The effect of the combined twisted tape and rectangular winglet inserts on heat transfer and pressure drop presented in terms of respective Nusselt number and friction factor is experimentally investigated. The characteristics of the combined twisted-tape and winglet include two twist ratios (Y = 4 and 5), three winglet- to duct-height ratios, (RB = 0.1, 0.15 and 0.2), four winglet-pitch to tape-width ratios, (RP = 2, 2.5, 4 and 5) and a single attack angle of winglet, α = 30°. The experimental results reveal that the Nusselt number and friction factor for the combined twisted-tape and V-winglet increase with increasing RB but decreasing RP. The inserted duct at RB = 0.2, RP = 2 and Y = 4 provides the highest heat transfer rate and friction factor but the one at RB = 0.1, RP = 2 and Y = 4 yields the highest thermal performance. The application of combined vortex-flow devices gives thermal performance around 17% higher than the twisted tape alone.  相似文献   

5.
A modified rectangular longitudinal vortex generator (LVG) obtained by cutting off the four corners of a rectangular wing is presented. Fluid flow and heat transfer characteristics of this LVG mounted in rectangular channel are experimentally investigated and compared with those of original rectangular LVG. Results show that the modified rectangular wing pairs (MRWPs) have better flow and heat transfer characteristics than those of rectangular wing pair (RWP). Near the positions of z = ±40 mm from the centerline of the heater plate, the local heat transfer is enhanced due to the strong longitudinal vortices generated by the presence of the LVGs. The down-sweep of the longitudinal vortices is beneficial to the heat transfer enhancement. The distance from the core of the main vortices of MRWP1 to the heater wall is slightly lower than those of RWP, and hence MRWP1 has a comparably better heat transfer characteristic.  相似文献   

6.
《Applied Thermal Engineering》2007,27(11-12):1806-1816
In this study, the heat transfer enhancement and pressure drop values of seven different fin angles with plain fin-tube heat exchangers were investigated. The numerical simulation of the fin-tube heat exchanger was performed by using a three dimensional (3-D) numerical computation technique. Therefore, a CFD computer code, the FLUENT was used to solve the equation for the heat transfer and pressure drop analyses in the fin-tube heat exchanger. The model drawing was created and meshed by using GAMBIT software. The heat transfer and pressure drop values of the vertical fin angle (θ = 0°) were provided to compare with variable inclined fin angles (θ = 5°, 10°, 15°, 20°, 25°, 30°). The heat transfer values were normalized to compare all cases. For inclined fin angle θ = 30°, which is the optimum angle, the maximum heat transfer enhancement per segment was obtained 1.42 W (the normalized value 105.24%), the maximum loss power associated with pressure drop per segment was only 0.54 mW.  相似文献   

7.
This article analyzes the detailed heat transfer phenomena during natural convection within tilted square cavities with isothermally cooled walls (BC and DA) and hot wall AB is parallel to the insulated wall CD. A penalty finite element analysis with bi-quadratic elements has been used to investigate the results in terms of streamlines, isotherms and heatlines. The present numerical procedure is performed over a wide range of parameters (103 ? Ra ? 105,0.015 ? Pr ? 1000,0° ? φ ? 90°). Secondary circulations cells are observed near corner regions of cavity for all φ’s at Pr = 0.015 with Ra = 105. Two asymmetric flow circulation cells are found to occupy the entire cavity for φ = 15° at Pr = 0.7 and Pr = 1000 with Ra = 105. Heatlines indicate that the cavity with inclination angle φ = 15° corresponds to large convective heat transfer from the wall AB to wall DA whereas the heat transfer to wall BC is maximum for φ = 75°. Heat transfer rates along the walls are obtained in terms of local and average Nusselt numbers and they are explained based on gradients of heatfunctions. Average Nusselt number distributions show that heat transfer rate along wall DA is larger for lower inclination angle (φ = 15°) whereas maximum heat transfer rate along wall BC occur for higher inclination angle (φ = 75°).  相似文献   

8.
The average heat transfer rates of gravitational and magnetic convection of water heated from below and cooled from above are measured for two cases of cold wall temperature θc at 10 °C and 30 °C. The height of the cylindrical enclosure is 2 mm with 40 mm in diameter. The magnetic field is imposed in a vertical direction to increase or decrease 29% of the gravitational acceleration in a bore space of a super-conducting magnet of 10 T at the solenoid center. The group of data at θc = 30 °C gives a better agreement with the classical heat transfer rate of Silveston than that at θc = 10 °C. This is probably due to the almost constant value in the volumetric magnetic susceptibility of water at about 10 °C.  相似文献   

9.
The effect of enhanced geometry (pore diameter, gap width) is investigated on the pool boiling of R-123/oil mixture for the enhanced tubes having pores with connecting gaps. Tubes having different pore diameters (and corresponding gap widths) are specially made. Significant heat transfer degradation by oil is observed for the present enhanced tubes. At 5% oil concentration, the degradation is 26–49% for Tsat = 4.4 °C. The degradation increases 50–67% for Tsat = 26.7 °C. The heat transfer degradation is significant even with small amount of oil (20–38% degradation at 1% oil concentration for Tsat = 4.4 °C), probably due to the accumulation of oil in sub-tunnels. The pore size (or gap width) has a significant effect on the heat transfer degradation. The maximum degradation is observed for dp = 0.20 mm tube at Tsat = 4.4 °C, and dp = 0.23 mm tube at Tsat = 26.7 °C. The minimum degradation is observed for dp = 0.27 mm tube for both saturation temperatures. It appears that the oil removal is facilitated for the larger pore diameter (along with larger gap) tube. The highest heat transfer coefficient with oil is obtained for dp = 0.23 mm tube, which yielded the highest heat transfer coefficient for pure R-123. The optimum tube significantly (more than 3 times) outperforms the smooth tube even with oil. The heat transfer degradation increases as the heat flux decreases.  相似文献   

10.
Analysis has been carried out for the energy distribution and thermal mixing in steady laminar natural convective flow through the rhombic enclosures with various inclination angles, φ for various industrial applications. Simulations are carried out for various regimes of Prandtl (Pr) and Rayleigh (Ra) numbers. Dimensionless streamfunctions and heatfunctions are used to visualize the flow and energy distribution, respectively. Multiple flow circulations are observed at Pr = 0.015 and 0.7 for all φs at Ra = 105. On the other hand, two asymmetric flow circulation cells are found to occupy the entire cavity for φ = 75° at higher Pr (Pr = 7.2 and 1000) and Ra (Ra = 105). Heatlines are found to be parallel circular arcs connecting the cold and hot walls for the conduction dominant heat transfer at Ra = 103. The enhanced convective heat transfer is explained with dense heatlines and convective loop of heatlines at Ra = 105. Heatlines clearly demonstrate that the left wall receives heat from the bottom wall as heatlines directly connect both the walls whereas the convective heat circulation cells play lead role to distribute the heat along the right wall, especially for smaller φs. On the other hand, the heat flow is evenly distributed to both side walls at higher φs via convection as well as direct conductive transport. Significant convective heat transfer from the bottom hot wall to the left cold wall occurs for φ = 30° cavity whereas the heat transfer to the right cold wall is maximum for φ = 75° irrespective of Pr. Average Nusselt number studies also show that φ = 30° cavity gives maximum heat transfer rate from the bottom to left wall irrespective of Pr in isothermal heating case. On the other hand, enhanced thermal mixing occurs at φ = 75° for both isothermal and non-isothermal heating strategies except at Pr = 0.015 in isothermal heating case.  相似文献   

11.
The behaviors of improved Heat transfer and the associated higher pressure drop for liquid flow in rectangular micochannels with longitudinal vortex generators (LVGs) were determined experimentally for the Reynolds numbers of 170–1200 with hydraulic diameter of 187.5 μm and aspect ratio of 0.067 for LVGs with different number of pairs and angles of attack. It was found that the range of critical Reynolds numbers (600–730) were at a much smaller value by adding LVGs than the one without (Re  2300); heat transfer performance was improved (9–21% higher for those with laminar flow and 39–90% for those with turbulent flow), while encountering larger pressure drop (34–83% for laminar flow and 61–169% for turbulent flow). Empirical correlations for these two parameters were then obtained by curve-fittings for a variety of rectangular microchannels under study.  相似文献   

12.
In this study, radiative and convective heat transfer coefficients at the ceiling are determined for a cooled ceiling room. Firstly, convective heat transfer is simulated numerically neglecting the radiative heat transfer at the surfaces (εf = εw = εc = 0), then, radiative heat transfer is calculated theoretically for different surface emissivities (εf = εw = εc = 0.5, 0.6, 0.7, 0.8 and 0.9) for different room dimensions (3 × 3 × 3, 4 × 3 × 4 and 6 × 3 × 4 m) and thermal conditions (Tf = 25 °C, Tw = 28–36 °C and Tc = 0–25 °C). Numerical data is compared with the results of correlations based on experimental data given in literature. New equations related to convective and total (including the effect of convection and radiation) heat transfer coefficients for ceiling are found in the current study.  相似文献   

13.
Experimental investigation was performed on the mixed convection heat transfer of thermal entrance region in an inclined rectangular duct for laminar and transition flow. Air flowed upwardly and downwardly with inclination angles from ?90° to 90°. The duct was made of duralumin plate and heated with uniform heat flux axially. The experiment was designed for determining the effects of inclination angles on the heat transfer coefficients and friction factors at seven orientations (θ = ? 90°, ?60°, ?30°, 0°, 30°, 60° and 90°), six Reynolds numbers (Re  420, 840, 1290, 1720, 2190 and 2630) within the range of Grashof numbers from 6.8 × 103 to 4.1 × 104. The optimum inclination angles that yielded the maximum heat transfer coefficients decreased from 30° to ?30° with the increase of Reynolds numbers from 420 to 1720. The heat transfer coefficients first increased with inclination angles up to a maximum value and then decreased. With further increase in Reynolds numbers, the heat transfer coefficients were nearly independent of inclination angles. The friction factors decreased with the increase of inclination angles from ?90° to 90° when Reynolds numbers ranged from 420 to 1290, and independent of inclination angles with higher Reynolds numbers.  相似文献   

14.
Experimental heat transfer studies during evaporation of R-134a inside a corrugated tube have been carried out. The corrugated tube has been provided with different tube inclination angles of the direction of fluid flow from horizontal, α. The experiments were performed for seven different tube inclinations, α, in a range of − 90° to + 90° and four mass velocities of 46, 81, 110 and 136 kg m 2 s 1 for each tube inclination angle during evaporation of R-134a. Data analysis demonstrate that the tube inclination angle, α, affects the boiling heat transfer coefficient in a significant manner. The effect of tube inclination angle, α, on heat transfer coefficient, h, is more prominent at low vapor quality and mass velocity. In the low vapor quality region, the heat transfer coefficient, h, for the + 90° inclined tube is about 62% more than that of the − 90° inclined tube. The results also showed that at all mass velocities, the highest average heat transfer coefficient were achieved for α = + 90°. An empirical correlation has also been developed to predict the heat transfer coefficient during flow boiling inside a corrugated tube with different tube inclinations.  相似文献   

15.
An experimental investigation has been carried out to study the heat transfer coefficient and friction factor by using artificial roughness in the form of specially prepared inverted U-shaped turbulators on the absorber surface of an air heater duct. The roughened wall is uniformly heated while the remaining three walls are insulated. These boundary conditions correspond closely to those found in solar air heaters.The experiments encompassed the Reynolds number range from 3800 to 18000; ratio of turbulator height to duct hydraulic mean diameter is varied from, e/Dh = 0.0186 to 0.03986 (Dh = 37.63 mm and e = 0.7 to 1.5 mm) and turbulator pitch to height ratio is varied from, p/e = 6.67 to 57.14 (p = 10 to 40 mm). The angle of attack of flow on turbulators, α = 90° kept constant during the whole experimentation. The heat transfer and friction factor data obtained is compared with the data obtained from smooth duct under similar geometrical and flow conditions. As compared to the smooth duct, the turbulator roughened duct enhances the heat transfer and friction factor by 2.82 and 3.72 times, respectively. The correlations have been developed for area averaged Nusselt number and friction factor for turbulator roughened duct.  相似文献   

16.
Natural convection in isosceles triangular enclosures with various configurations (case 1 — inverted, case 2 — straight and case 3 — tilted) is studied via heatline analysis for linear heating of inclined walls. Detailed analysis and comparison for various base angles (φ = 45°, 60°) of triangular enclosures have been carried out for a range of fluids (Pr = 0.015  1000) within Ra = 103  105 using Galerkin finite element method. The heat flow distributions indicate conduction dominant heat transfer at low Ra (Ra = 103) for case 1 and case 2 whereas in case 3, convective heat flow is observed due to high buoyancy force. As Ra increases, enhanced thermal mixing is observed at the core of the cavity. Wall to wall heat transfer occurs at walls AB and AC due to linear heating boundary condition in all the cases. Although the distributions of fluid flow and heat flow are qualitatively similar for φ = 45° and 60°, the intensity of fluid flow and heat flow decreases as φ increases. Strength of fluid flow and heat flow circulation cells is found to be higher in case 3 for identical parameters. Results show that upper side wall (AC) for case 3 exhibits higher heat transfer rates whereas heat transfer rates for walls AB and AC are the same for case 1 and case 2. Also NuAB is higher for case 2 followed by case 1 and case 3 at the middle portion of wall AB. Thus to achieve high heat transfer from fluid to wall at the central region, case 2 and case 3 configurations may be recommended at high Ra (Ra = 105) and Pr, irrespective of φ.  相似文献   

17.
Numerical analyses were performed for the effect of inclined angle on the mixing flow in a square channel with uniform temperature walls (Tw = 30 °C) and inlet temperature (T0 = 10 °C). Three-dimensional governing equations were solved numerically for Re = 100, Pr = 0.72 and various inclined angles (from ?90° to 90°). Three-dimensional behavior of fluid in a channel was examined for each angle. Thermal performance was evaluated using the relationship between Nusselt number ratio and pressure loss ratio with and without buoyancy induced flow as a parameter of inclined angles. High heat transfer and low pressure loss region was from ?15° to ?60° in thermal performance using mean Nusselt number ratio.  相似文献   

18.
In this paper we present the results on experimental investigation of the local opposing mixed convection heat transfer in the vertical flat channel with symmetrical heating in a laminar–turbulent transition region. The experiments were performed in airflow (p = 0.1–1.0 MPa) in the range of Re from 1.5 × 103 to 6.6 × 104 and Grq up to 1 × 1011 at the limiting condition qw1 = qw2 = const. The analysis of the results revealed significant increase in the heat transfer with increasing of air pressure (Gr number). Also sharp increase in heat transfer was noticed in the region with vortex flow in comparison with the turbulent flow region.  相似文献   

19.
纵向涡强化换热的优化设计及机理分析   总被引:1,自引:0,他引:1  
对带纵向涡发生器的椭圆管翅片换热器空气侧表面的换热和流动特性进行了三维数值模拟.深入分析了纵向涡对流场和温度场的影响,并通过场协同原理揭示了纵向涡强化换热的根本机理,即减小了速度和温度梯度之间的夹角,改善了速度场和温度场的协同性.在此基础上,对纵向涡发生器的布置位置(上游布置和下游布置)和纵向涡发生器的攻角α(15°,30°,45°,60°)进行了优化设计.结果表明:当纵向涡发生器布置于换热管下游时,具有更好的强化换热能力;在纵向涡发生器采用下游布置的前提下,当纵向涡发生器的攻角α=30°时,具有最佳的强化换热能力.  相似文献   

20.
Delta-winglet vortex generators (VGs) are known to enhance the heat transfer between the energy-carrying fluid and the heat transfer surfaces in plate-fin-and-tube banks. In this study optimal angles of attack of the delta-winglets are investigated based on the Pareto optimal strategy. The optimization process combines a CFD analysis, genetic algorithms and the response surface methodology. The angle of attack of a pair a delta-winglet-type VGs mounted behind each tube is varied between β = ?90° and +90°. Three circular tube rows with inline and staggered tube arrangements are investigated for Reynolds numbers from 200 to 1200 (based on the inlet height and inlet velocity). The flow structure and heat transfer behavior is analyzed in detail for certain cases and the staggered and the inline tube arrangements are compared. Finally, for each of these arrangements the optimal sets of angles of attack for different Reynolds numbers are presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏