首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Shell and tube heat exchanger is one of the most prevalent heat exchangers with a wide variety of industrial applications, i.e., power plants, chemical processes, marine industries, HVAC systems, cooling of hydraulic fluid and engine oil in heavy duty diesel engines and the like specifically where a need to heat or cool a large fluid volume exist and also higher-pressure use. In the present study, the effect of using Al2O3-water nanofluid on thermal performance of a commercial shell and tube heat exchanger with segmental baffles is assessed experimentally. For this purpose, Al2O3-gamma nanoparticles with 15 nm mean diameter (99.5% purity) and Sodium Dodecyl Benzene Sulphonate (SDBS) as surfactant are used to make aqueous Al2O3 nanofluid at three various volume fractions of nanoparticles (φ = 0.03, 0.14 and 0.3%). Indeed, in this paper the effect of some parameters of hot working fluid such as Reynolds number and volume concentration of nanoparticles on heat transfer characteristics, friction factor and thermal performance factor of a shell and tube heat exchanger under laminar flow regime is investigated. The results indicate a substantial increment in Nusselt number as well as the overall heat transfer coefficient of heat exchanger by enhancement of Reynolds number and it can be seen that, at a certain Reynolds number, heat transfer characteristics of heat exchanger increase as the nanoparticles volume concentration increases. Outcomes of the heat transfer evaluation demonstrate that applying nanofluids instead of base fluid lead to increment of Nusselt number up to 9.7, 20.9 and 29.8% at 0.03, 0.14 and 0.3 vol%, respectively. Likewise it is seen that at mentioned nanoparticles volume fractions, overall heat transfer coefficient of heat exchanger enhances around 5.4, 10.3 and 19.1%, respectively. In term of pressure drop, a little penalty is found by using nanofluid in the test section. Eventually a thermal performance assessment on the heat exchanger was conducted. According to the analysis results, utilizing nanofluid at minimum and maximum nanoparticles volume fractions (φ = 0.03 and 0.3%) results in average augmentation of around 6.5% and 18.9% in thermal performance factor (η) of the heat exchanger compared to the base liquid, respectively.  相似文献   

2.
This article investigates the thermoelectric air-cooling module for electronic devices. The effects of heat load of heater and input current to thermoelectric cooler are experimentally determined. A theoretical model of thermal analogy network is developed to predict the thermal performance of the thermoelectric air-cooling module. The result shows that the prediction by the model agrees with the experimental data. At a specific heat load, the thermoelectric air-cooling module reaches the best cooling performance at an optimum input current. In this study, the optimum input currents are from 6 A to 7 A at the heat loads from 20 W to 100 W. The result also demonstrates that the thermoelectric air-cooling module performs better performance at a lower heat load. The lowest total temperature difference-heat load ratio is experimentally estimated as ?0.54 W K?1 at the low heat load of 20 W, while it is 0.664 W K?1 at the high heat load of 100 W. In some conditions, the thermoelectric air-cooling module performs worse than the air-cooling heat sink only. This article shows the effective operating range in which the cooling performance of the thermoelectric air-cooling module excels that of the air-cooling heat sink only.  相似文献   

3.
In the present study, experimental efforts have been performed to explore the forced convection heat transfer using water-based suspension of Al2O3 nanoparticles (nanofluid) to replace the pure water as the working fluids in circular tubes. The nanofluid was prepared as a functional forced convection fluid and the thermal properties including the density, thermal conductivity, and dynamic viscosity were investigated experimentally. Besides, forced convection heat transfer in circular tubes was investigated with water-based nanofluid containing various mass fractions of the Al2O3 nanoparticles (2, 5, and 10 wt%) under the following operating conditions: the volume flow rate Qf = 23.6–183.5 cm3/min (the Reynolds number Ref,0 = 188–2095), the heating power applied at the outer wall of the tube qo , eff. = 1908–7362 W/m2, and the inlet fluid temperature Tin = 24.5–25.5 °C or 49.5–50.5 °C. Measured data showed that the dispersion of increasing mass fraction of Al2O3 nanoparticles can effectively improve the thermal conductivity relative to the pure water. Besides, higher average heat transfer effectiveness εh,btd and figure of merit FOM are noted for the cases with higher inlet fluid temperature Tin.  相似文献   

4.
A thermoelectric domestic refrigerator has been developed, with a single compartment of 0.225 m3, for food preservation at 5 °C. The cooling system is made up of two equal thermoelectric devices, each composed of a Peltier module (50 W) with its hot side in contact with a two-phase and natural convection thermosyphon (TSV) and a two-phase and capillary lift thermosyphon (TPM), in contact with the cold side.The entire refrigerator has been simulated and designed using a computational model, based on the finite difference method. Subsequently an experimental optimization phase of the thermosyphons was carried out, until thermal resistance values of RTSV = 0.256 K/W and RTPM = 0.323 K/W were obtained. These values were lower than those obtained with finned heat sinks.Finally, a functional prototype of a thermoelectric refrigerator was built, and the results which were obtained demonstrate that it is able to maintain a thermal drop (Ambient Temperature–Inside Temperature) of 19 °C. The electric power consumption at nominal conditions was 45 W, reaching a COP value of 0.45. The study demonstrated that by incorporating these two-phase devices into thermoelectric refrigeration increases the COP by 66%, compared with those which use finned heat sinks.  相似文献   

5.
Solar hybrid systems with thermoelectric generators   总被引:1,自引:0,他引:1  
The possibility of using of thermoelectric generators in solar hybrid systems has been investigated. Four systems were examined, one working without radiation concentration, of the traditional PV/Thermal geometry, but with TEGs between the solar cells and heat extractor, and three other using concentrators, namely: concentrator – TEG ? heat extractor, concentrator ? PV cell ? TEG ? heat extractor, and PV cell – concentrator – TEG – heat extractor. The TEGs based on traditional semiconductor material Bi2Te3 and designed for temperature interval of 50–200 °C were studied experimentally. It was found that the TEG’s efficiency has almost linear dependence on the temperature difference ΔT between its plates, reaching 4% at ΔT = 155 °C (hot plate at 200 °C) with 3 W of power generated over the matched load. The temperature dependencies of current and voltage are also linear; accordingly, the power generated has quadratic temperature dependence. The experimental parameters, as well as parameters of two advanced TEGs taken from the literature, were used for estimation of performance of the hybrid systems. The conclusions are drawn in relation to the efficiency at different modes of operation and the cost of hybrid systems, as well as some recommendations in relation to optimal solar cells for applications in these systems.  相似文献   

6.
The convective heat transfer, friction factor and effectiveness of different volume concentrations of Fe3O4 nanofluid flow in an inner tube of double pipe heat exchanger with return bend has been estimated experimentally and turbulent flow conditions. The test section used in this study is of double pipe type in which the inner tube diameter is 0.019 m, the annulus tube diameter is 0.05 m and the total length of inner tube is 5 m. At a distance of 2.2 m from the inlet of the inner tube the return bend is provided. The hot Fe3O4 nanofluid flows through an inner tube, where as the cold water flows through an annulus tube. The volume concentrations of the nanoparticles used in this study are 0.005%, 0.01%, 0.03% and 0.06% with Reynolds number range from 15,000 to 30,000. Based on the results, the Nusselt number enhancement is 14.7% for 0.06% volume concentration of nanofluid flow in an inner tube of heat exchanger at a Reynolds number of 30,000 when compared to base fluid data; the pumping penalty of nanofluid is < 10%. The effectiveness of heat exchanger for water and nanofluid flow is explained in terms of number of transfer units (NTU) in order to estimate the overall performance of the double pipe heat exchanger. New correlations for Nusselt number and friction factor have been developed based on the experimental data.  相似文献   

7.
《Exergy》2002,2(2):113-118
In this study, an exergoeconomic analysis of condenser type parallel flow heat exchangers is presented. Exergy losses of the heat exchanger and investment and operation expenses related to this are determined with functions of steam mass flow rate and water exit temperature at constant values of thermal power of the heat exchanger at 75240 W, cold water mass flow rate and temperature. The inlet temperature of water is 18 °C and exit temperatures of water are varied from 25 °C to 36 °C. The values of temperature and pressure of saturated steam in the condenser are given to be Tcon=47 ° C and Pcon=10.53 kPa. Constant environment conditions are assumed. Annual operation hour and unit price of electrical energy are taken into account for determination of the annual operation expenses. Investment expenses are obtained according to the variation of heat capacity rate and logarithmic mean temperature difference and also heat exchanger dimension determined for each situation. The present analysis is hoped to be useful in determining the effective parameters for the most appropriate exergy losses together with operating conditions and in finding the optimum working points for the condenser type heat exchangers.  相似文献   

8.
The present study aims to identify effects due to uncertainties in effective dynamic viscosity and thermal conductivity of nanofluid on laminar natural convection heat transfer in a square enclosure. Numerical simulations have been undertaken incorporating a homogeneous solid–liquid mixture formulation for the two-dimensional buoyancy-driven convection in the enclosure filled with alumina–water nanofluid. Two different formulas from the literature are each considered for the effective viscosity and thermal conductivity of the nanofluid. Simulations have been carried out for the pertinent parameters in the following ranges: the Rayleigh number, Raf = 103–106 and the volumetric fraction of alumina nanoparticles, ? = 0–4%. Significant difference in the effective dynamic viscosity enhancement of the nanofluid calculated from the two adopted formulas, other than that in the thermal conductivity enhancement, was found to play as a major factor, thereby leading to contradictory results concerning the heat transfer efficacy of using nanofluid in the enclosure.  相似文献   

9.
An experimental study was carried out in order to find out the effects of Al2O3 nanofluid with a mean diameter of 20 nm on heat transfer, pressure drop and thermal performance of a double tubes heat exchanger. The effective viscosity of nanofluid was measured in various temperatures ranging from 27 °C to 55 °C. Experiments were carried out at different Reynolds numbers ranging from 5000 to 20,000, approximately, and in various nanoparticles concentration up to 1% by volume. Results indicate that there is a good potential in promoting the thermal performance of heat exchanger by adding nanoparticles in the investigated ranges where there is not a severe pressure drop penalty. The empirical correlation was created for Nusselt number variation based on the Reynolds number and nanoparticles concentration.  相似文献   

10.
The present study aims to explore experimentally the influence of elevated inlet fluid temperature on the turbulent forced convective heat transfer effectiveness of using alumina–water nanofluid over pure water in an iso-flux heated horizontal circular tube at a fixed heating power. A copper circular pipe of inner diameter 3.4 mm was used in the forced convection experiments undertaken for the pertinent parameters in the following ranges: the inlet fluid temperature, Tin = 25 °C, 37 °C and 50 °C; the Reynolds number, Rebf = 3000–13,000; the mass fraction of the alumina nanoparticles in the water-based nanofluid formulated, ωnp = 0, 2, 5, and 10 wt.%; and the heating flux, qo = 57.8–63.1 kW/m2. The experimental results clearly indicate that the turbulent forced convection heat transfer effectiveness of the alumina–water nanofluid over that of the pure water can be further uplifted by elevating its inlet temperature entering the circular tube well above the ambient, thereby manifesting its potential as an effective warm functional coolant. Specifically, an increase in the averaged heat transfer enhancement of more than 44% arises for the nanofluid of ωnp = 2 wt.% as the inlet fluid temperature is increased from 25 °C to 50 °C.  相似文献   

11.
Spray water cooling is an important technology used in industry for the cooling of materials from temperatures up to 1800 K. The heat transfer coefficient in the so-called steady film boiling regime is known to be a function of the water impact density. Below a specific surface temperature TL, the heat transfer coefficient shows a strong dependence on temperature (Leidenfrost effect). These findings are the results of complex self-organizing two-phase boiling heat transfer phenomena.The heat transfer coefficient was measured by an automated cooling test stand (instationary method) under clean (non-oxidizing) surface conditions. Compared to the common thought, an additional temperature dependency in the high temperature regime was found. The heat transfer from the material to the outflowing spray water is explained by a simple model of the two-phase flow region. From the experimental data, an analytic correlation for the dependence of the heat transfer coefficient α as an analytic function of water impact density VS and temperature ΔT is provided.For water temperatures around 291 K, surface temperatures between 473 and 1373 K, i.e. ΔT > 180 K and water impact densities between VS = 3 and 30 kg/(m2 s) the heat transfer coefficient α was measured. The spray was produced with full cone nozzles (vd  13–15 m/s, dd  300–400 μm).  相似文献   

12.
The aim of this work was an experimental study of the temporal evolution of isobaric adsorption uptake (release) for simplest configuration of an adsorbent-heat exchanger unit, namely, a monolayer of loose adsorbent grains located on a metal plate. The study was performed by a large temperature jump method at four various boundary conditions of an adsorptive heat transformation cycle typical for air-conditioning application driven by low temperature heat: Te = 5 and 10 °C, Tc = 30 and 35 °C and THS = 80 °C. The size of the Fuji silica grains was varied from 0.2 to 1.8 mm to investigate its effect on water sorption dynamics. For each boundary set and grain size the experimental kinetic curve could be described by an exponential function up to 80–90% of the equilibrium conversion. Desorption runs are found to be faster than appropriate adsorption runs by a factor of 2.2–3.5, hence, for optimal durations of the isobaric ad- and desorption phases of the chilling cycle should be selected accordingly. The size R of the adsorbent grains was found to be a powerful tool to manage the dynamics of isobaric water ad-/desorption. For large grains the characteristic time was strongly dependent on the grain size and proportional to R2. Much less important appeared to be an impact of the boundary conditions which variation just weakly affected the dimensionless kinetic curves for the four tested cycles. The maximal specific cooling/heating power was proportional to the maximal temperature difference ΔT and the contact area S between the layer and the metal plate, and can exceed 10 kW/kg. The heat transfer coefficient α estimated from this power was as large as 100–250 W/(m2 K) that much exceeds the value commonly used to describe the cycle dynamics.  相似文献   

13.
It would be misleading to consider only cost aspect of the design of a heat exchanger. High maintenance costs increase total cost during the services life of heat exchanger. Therefore exergy analysis and energy saving are very important parameters in the heat exchanger design. In this study, the effects of surface geometries of three different type heat exchangers called as PHEflat (Flat plate heat exchanger), PHEcorrugated (Corrugated plate heat exchanger) and PHEasteriks (Asterisk plate heat exchanger) on heat transfer, friction factor and exergy loss were investigated experimentally. The experiments were carried out for a heat exchanger with single pass under condition of parallel and counter flow. In this study, experiments were conducted for laminar flow conditions. Reynolds number and Prandtl number were in the range of 50 ? Re ? 1000 and 3 ? Pr ? 7, respectively. Heat transfer, friction factor and exergy loss correlations were obtained according to the experimental results.  相似文献   

14.
The thermophysical properties like thermal conductivity and viscosity of Al2O3 nanofluid is determined through experiments at different volume concentrations and temperatures and validated. Convective heat transfer coefficient and friction factor data at various volume concentrations for flow in a plain tube and with twisted tape insert is determined experimentally for Al2O3 nanofluid. Experiments are conducted in the Reynolds number range of 10,000–22,000 with tapes of different twist ratios in the range of 0 < H/D < 83. The heat transfer coefficient and friction factor of 0.5% volume concentration of Al2O3 nanofluid with twist ratio of five is 33.51% and 1.096 times respectively higher compared to flow of water in a tube. A generalized regression equation is developed for the estimation of Nusselt number and friction factor valid for both water and nanofluid in plain tube and with inserts under turbulent flow conditions.  相似文献   

15.
In this study, the cooling performance of Al2O3–H2O nanofluid was experimentally investigated as a much better developed alternative for the conventional coolant. For this purpose the nanofluid was passed through the custom-made copper minichannel heat sink which is normally attached with the electronic heat source. The thermal performance of the Al2O3–H2O nanofluid was evaluated at different volume fraction of the nanoparticle as well as at different volume flow rate of the nanofluid. The volume fraction of the nanoparticle varied from 0.05 vol.% to 0.2 vol.% whereas the volume flow rate was increased from 0.50 L/min to 1.25 L/min. The experimental results showed that the nanofluid successfully has minimized the heat sink temperature compared to the conventional coolant. It was noticed also that the thermal entropy generation rate was reduced via using nanofluid instead of the normal water. Among the other functions of the nanofluid are to increase the frictional entropy generation rate and to drop the pressure which are insignificant compared to the normal coolant. Given the improved performance of the nanofluid, especially for high heat transportation capacity and low thermal entropy generation rate, it could be used as a better alternative coolant for the electronic cooling system instead of conventional pure water.  相似文献   

16.
The turbulent convective heat transfer and friction factor behavior of Al2O3 nanofluid in a circular tube with different aspect ratios of longitudinal strip inserts are studied experimentally. Experiments are conducted with water and nanofluid in the range of 3000 < Re < 22,000, particle volume concentration 0 < φ < 0.5% and longitudinal strip aspect ratios of 0 < AR < 18. The agreement between the values of Nusselt number obtained with water is satisfactory when compared with the data of Heish and Huang. Results indicate that heat transfer coefficients increase with nanofluid volume concentration and decrease with aspect ratio.  相似文献   

17.
A suspended, planar multistage micro thermoelectric (TE) cooler is designed using thermal network model to cool MEMS devices. Though the planar (two-dimensional) design is compatible with MEMS fabrication, its cooling performance is reduced compared to that of a pyramid (three-dimensional) design, due to a mechanically indispensable thin dielectric substrate (SiO2) and technical limit on TE film thickness. We optimize the planar, six-stage TE cooler for maximum cooling, and predict ΔTmax = 51 K with power consumption of 68 mW using undoped, patterned 4–10 μm thick co-evaporated Bi2Te3 and Sb2Te3 films. Improvement steps of the planar design for achieving cooling performance of the ideal pyramid design are discussed. The predicted performance of a fabricated prototype is compared with experimental results with good agreements.  相似文献   

18.
《Applied Thermal Engineering》2005,25(11-12):1684-1696
Local heat transfer coefficients were measured on fin-tube heat exchanger with winglets using a single heater of 2 inch diameter and five different positions of winglet type vortex generators. The measurements were made at Reynolds number about 2250. Flow losses were determined by measuring the static pressure drop in the system. Results showed a substantial increase in the heat transfer with winglet type vortex generators. It has been observed that average Nusselt number increases by about 46% while the local heat transfer coefficient improves by several times as compared to plain fin-tube heat exchanger. The maximum improvement is observed in the re-circulation zone. The best location of the winglets was with ΔX = 0.5D and ΔY = 0.5D. The increase in pressure drop for the existing situation was of the order of 18%.  相似文献   

19.
This work uses an optimization procedure consisting of a simplified conjugate-gradient method and a three-dimensional fluid flow and heat transfer model to investigate the optimal geometric parameters of a double-layered microchannel heat sink (DL-MCHS). The overall thermal resistance RT is the objective function to be minimized, and the number of channels N, channel width ratio β, lower channel aspect ratio αl, and upper channel aspect ratio αu are the search variables. For a given bottom area (10 × 10 mm) and heat flux (100 W/cm2), the optimal (minimum) thermal resistance of the double-layered microchannel heat sink is about RT = 0.12 °C/m2W. The corresponding optimal geometric parameters are N = 73, β = 0.50, αl = 3.52, and, αu = 7.21 under a total pumping power of 0.1 W. These parameters reduce the overall thermal resistance by 52.8% compared to that yielded by an initial guess (N = 112, β = 0.37, αl = 10.32, and αu = 10.93). Furthermore, the optimal thermal resistance decreases rapidly with the pumping power and then tends to approach an constant value. As the pumping power increases, the optimal values of N, αl, and αu increase, whereas the optimal β value decreases. However, increasing the pumping power further is not always cost-effective for practical heat sink designs.  相似文献   

20.
Turbulent convective heat transfer and friction factor characteristics of magnetic Fe3O4 nanofluid flowing through a uniformly heated horizontal circular tube with and without twisted tape inserts are estimated experimentally. Experiments are conducted in the particle volume concentration range of 0 < φ < 0.6%,twisted tape inserts of twist ratio in the range of 0 < H/D < 15and Reynolds number range of 3000 < Re < 22000. Heat transfer and friction factor enhancement of 0.6% volume concentration of Fe3O4 nanofluid in a plain tube with twisted tape insert of twist ratio H/D = 5 is 51.88% and 1.231 times compared to water flowing in a plain tube under same Reynolds number. Generalized regression equation is presented for the estimation of Nusselt number and friction factor for both water and Fe3O4 nanofluid in a plain tube and with twisted tape inserts under turbulent flow condition.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏