首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 46 毫秒
1.
骆日佑  温祝堂等 《同位素》1995,8(4):204-209
建立了广东处级吸收剂量标准(60Co γ射线)硫酸亚铁剂量计,在25度,303nm下精确测得Fe^3 的摩尔消光系数=2174.31mol^-1,.mol^-1.cm^-1,转换因子K=280.2Gy,总不确定度为2.7%,对影响硫酸亚铁剂量计的主要因素进行了研究,本标准与国家标准及IAEA保证剂量进行比对,结果符合得较好。  相似文献   

2.
本文讨论了作为Fricke剂量计辐照容器的玻璃安瓿的预处理和封装方法对其精密度的影响,给出了最佳的预处理和封装方法,从而保证了测量值精密度在±1%以内。探讨了用市售10ml塑料滴瓶作为辐照容器的可能性,并给出预处理方法。  相似文献   

3.
辐射剂量验证技术是肿瘤放射治疗过程中的关键技术,Fricke凝胶剂量计因其制备简单、组织等效性好正逐步成为研究的热点。本研究采用辐射交联"一步法"制备Fricke凝胶剂量计,利用傅里叶红外光谱仪(Fourier transform infrared spectrometer,FTIR)、X线衍射仪(X-ray diffractometer,XRD)与热重分析仪(Thermo-gravimetric analyser,TGA)等仪器对凝胶样品的化学结构和成分进行了分析,利用分子动力学模拟研究了亚铁离子在凝胶剂量计中的扩散行为,并在医用加速器下对凝胶进行辐照,利用多功能酶标仪测定凝胶的辐射剂量响应。结果表明,辐射法制备的Fricke凝胶剂量计中,聚丙烯酸链可以抑制亚铁离子在凝胶样品中的扩散行为,添加二甲酚橙(Xylenol orange,XO)可以改善Fricke凝胶剂量计的剂量敏感性。  相似文献   

4.
研究结果表明,重铬酸溶液/银剂量计在10-40kGy剂量范围内,剂量响应线性良好;剂量率和辐照温度对剂量响应影响不大;剂量计溶液辐照前后稳定;严格控制剂量计的制备和测量程序,剂量测量精度可达±1.0%,总不确定度为±3.5%。可作为高剂量的传递标准剂量计。  相似文献   

5.
在放射治疗中,吸收剂量空间分布的准确测定是决定放疗效果的关键。通常Fricke凝胶剂量计用于空间剂量分布的测量,但Fricke凝胶剂量计存在Fe~(3+)扩散问题,限制了剂量计测定的准确性,导致剂量验证产生误差。提出毛细管型Fricke凝胶剂量计,通过物理限制与化学限制的方法,限制Fe~(3+)在二维方向上扩散问题,反演推导实现Fe~(3+)在一维方向上的扩散校正。在一维方向上构建毛细管型Fricke凝胶剂量计结合二分之一合并法的图像处理方法,实现对Fricke凝胶剂量计的准确校正。为临床吸收剂量空间分布的准确测定提供良好的前景。  相似文献   

6.
7.
李明非  白金昌  姜晓梅 《核技术》2003,26(12):946-948
给出了柱筒型自给能γ剂量计探头在γ射线的照射下电荷沉积的测量结果,并讨论了其部分特性。  相似文献   

8.
叙述了一种新型硅吸收剂量量热计的结构、电加热校准情况及其测量原理,给出了用该量热计标定中国科学院新疆物理研究所^60Coγ辐照室中吸收剂量率及升降源过程吸收剂量对距离分布情况,说明升降源过程吸收剂量尤其在短时间、近距离、小剂量等辐照情况下不可忽视。  相似文献   

9.
李明非 《核技术》1998,21(7):433-435
给出了不同结构自给能γ剂量计探头在γ射线的照射下积累电荷的测量结果,并讨论了其部分特性。  相似文献   

10.
用蒙特卡洛程序EGSnrc/DOSRZnrc模拟研究60Coγ射线中Al2O3剂量计的大小对吸收剂量的影响。结果表明,在准直60Coγ射线照射中,Al2O3剂量计的大小对剂量计的吸收剂量比率因子有明显的影响。Al2O3剂量计的半径或厚度不一样,吸收剂量比率因子也不一样,差异可达6%。而大小一定的Al2O3剂量计在水体模中不同深度(0.5~8.0 cm)处吸收剂量比率因子的值变化很小,与平均值的最大偏差不大于1%。  相似文献   

11.
Radiotherapy uses ionizing radiation to destroy tumor cells. The absorbed dose control in the target volume is realized through radiation sensors, such as Fricke dosimeters and radiochromic film, which permit to realize bi-dimensional evaluations at once and because of that, they will be used in this study as well. Among the several types of cancer suitable for ionizing radiation treatment, the Mycosis Fungoides, a lymphoma that spreads on the skin surface and depth, requires for its treatment total body irradiation by high-energy electrons. In this work the Fricke xylenol gel (FXG) was used in order to obtain information about the absorbed dose distribution induced by the electron interactions with the irradiated tissues and to control this type of treatment. FXG can be considered as an alternative dosimeter, since up to now only films have been used. FXG sample cuvettes, simulating two selected tomos (cranium and abdomen) of the Rando anthropomorphic phantom, were positioned along with radiochromic films for comparison. The phantom was subjected to Stanford total body irradiation using 6 MeV electrons. Tomographic images were acquired for both dosimeters and evaluated through horizontal and vertical profiles along the tomographic centers. These profiles were obtained through a Matlab routine developed for this purpose. From the obtained results, one could infer that, for a superficial and internal patient irradiation, the FXG dosimeter showed an absorbed dose distribution similar to the one of the film. These results can validate the FXG dosimeter as an alternative dosimeter for the Mycosis Fungoides treatment planning.  相似文献   

12.
电子束辐射加工吸收剂量标准的测量系统   总被引:4,自引:0,他引:4  
张利民  顾继青 《核技术》1995,18(4):238-246
  相似文献   

13.
14.
15.
在电离辐射计量检定工作中,标准剂量计的测量结果通过检定逐级传递到工作计量器具,以实现单位统一和量值准确可靠。由于环境水平γ射线剂量率较低,国际上常用的PTW-UNIDOS系列标准剂量计无法满足需要。针对这一特点,结合蒙特卡罗方法对高气压电离室的X射线、γ射线和宇宙射线响应特性进行模拟计算,进行了能量补偿型高气压电离室改进。测试结果表明:剂量率约30 μGy/h时,能量补偿型高气压电离室在87 keV~1.25 MeV能量范围内相对于137Cs γ射线的响应偏差不大于6%,宇宙射线和137Cs γ射线的响应偏差不大于10%,在0.5 μGy/h~1 mGy/h范围内相对固有误差为-3%,0.5 μGy/h时的重复性为0.7%,校准因子的不确定度为4%(k=2),可作为环境水平标准剂量计在校准检定工作中使用。  相似文献   

16.
本文介绍我们研制的中子吸收剂量量热计的原理、结构及其测量系统。测量了池式研究用反应堆中的中子吸收剂量并得到满意的结果。该量热计轻便、简单、测量迅速而准确。已精确知道比热数值的其它吸收材料均可采用本设计。  相似文献   

17.
巴维真  郝运海 《核技术》1995,18(1):45-50
叙述了热损补偿型铝吸收剂量量热计的结构及测量原理,给出了量热计在10-35℃工作温区的电加热标定因子,得到了60Coγ辐照室中剂量率对距离的分布。  相似文献   

18.
新型硅吸收剂量量热计的电校准   总被引:1,自引:0,他引:1  
叙述了新型硅吸收剂量量热计的结构及电校准原理;给出了量热计在0-35℃工作温区的 热校准因子,拟事出硅比热随温度变化关系式。并对实验误差进行了讨论。  相似文献   

19.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号