Electrochemical determination of dopamine (DA) and serotonin (5-HT) have been studied at a modified glassy carbon electrode (GCE) in 0.1 M phosphate buffer solution (PBS) using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) at pH 7.4, all over the interfering biomolecule ascorbic acid (AA). The GCE was modified by palladium-functionalized, multi-walled carbon nanotubes (MWCNTs-Pd) with electrochemical deposition of poly 3,4-ethylenedioxy pyrrole (PEDOP), denoted as PEDOP/MWCNTs-Pd/GCE, and investigated by SEM and EIS experiments. The highly electrocatalytic activity of the modified electrode toward 5-HT and DA was demonstrated from the sensitive and well-separated voltammetric experiment. The oxidation peaks found were 0.165 and 0.355 mV for DA and 5-HT, respectively. The composite film shows a significant accumulation effects on two species, as well as the mutual interference among the analytes. This biosensor was best in response compared to other modified electrodes made in the same lab. The lowest detection limits were found to be 5.0 x 10(-9) and 1.0 x 10(-8) for 5-HT and DA, respectively. The respective linear ranges were determined as 1.0 x 10(-7) to 2.0 x 10(-4) and 1.0 x 10(-7) to 2.0 x 10(-4) for 5-HT and DA.  相似文献   

2.
A facile and reliable electrochemical technique at beta-cyclodextrin incorporated carbon nanotubes modified glassy carbon electrode (beta-CD/CNTs/GCE) was proposed for determination of pentachlorophenol (PCP). The electrochemical behavior of PCP at the beta-CD/CNTs/GCE was investigated by cyclic voltammetry and linear sweep voltammetry. The beta-CD/CNTs/GCE showed good analytical performance characteristics in electrocatalytic oxidation of PCP, compared with the simple carbon nanotube modified electrode (CNTs/GCE) and bare glassy carbon electrode (GCE). After accumulation for 5 min on beta-CD/CNTs/GCE, the peak current increased linearly with the concentration of PCP in the range from 8.0 x 10(-7) to 1.04 x 10(-5) mol/L. The detection limit was 4.0 x 10(-8) mol/L at 3 sigma level. The proposed electrode presented good repeatability for the determination of PCP in artificial wastewater, and the recovery was 97%-103%. This modified electrode combined the advantages of carbon nanotubes and supramolecular cyclodextrin, leading to new capabilities for electrochemical detection of PCP.  相似文献   

3.
The electrochemical oxidation of the adenine moiety in NAD+ and other adenine nucleotides at carbon paste electrodes gives rise to redox-active products which strongly adsorb on the electrode surface. Carbon paste electrodes modified with the oxidation products of NAD+ show excellent electrocatalytic activity toward NADH oxidation, reducing its overpotential by about 400 mV. The rate constant for the catalytic oxidation of NADH, determined by rotating disk electrode measurements and extrapolation to zero concentration of NADH, was found to be 2.5 x 10(5) M-1 s-1. The catalytic oxidation current allows the amperometric detection of NADH at an applied potential of +50 mV (Ag/AgCl) with a detection limit of 4.0 x 10(-7) M and linear response up to 1.0 x 10(-5) M NADH. These modified electrodes can be used as amperometric transducers in the design of biosensors based on coupled dehydrogenase enzymes and, in fact, we have designed an amperometric biosensor for glycerol based on the glycerol dehydrogenase (GlDH) system. The enzyme GlDH and its cofactor NAD+ were co-immobilized in a carbon paste electrode using an electropolymerized layer of nonconducting poly(o-phenylenediamine) (PPD). After partial oxidation of the immobilized NAD+, the modified electrode allows the amperometric detection of the NADH enzymatically obtained at applied potential above 0 V (Ag/AgCl). The resulting biosensor shows a fast and linear response to glycerol within the concentration range of 1.0 x 10(-6)-1.0 x 10(-4) M with a detection limit of 4.3 x 10(-7) M. The amperometric response remains stable for at least 3 days. The biosensor was applied to the determination of glycerol in a plant-extract syrup, with results in good agreement with those for the standard spectrophotometric method.  相似文献   

4.
A new biosensor is prepared by cross-linking glucose oxidase (GOD) with glutaradehyde at the electrode combining Au nanoparticles (AuNP) with multi-walled carbon nanotubes (MWCNTs). Au nanoparticles-doped chitosan (CS) solution (AuNP-CS) is prepared by treating the CS solution followed by chemical reduction of Au (III) with NaBH4. MWCNTs are then dispersed in AuNP-CS solution. TEM, FT-IR, and UV-Vis show that the AuNP-CS solution is highly dispersed and stable. The synergistic effect between AuNP and CNTs of the AuNP-CNTs-CS material has been investigated by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and amperometric methods. The modified glassy carbon electrode (GCE) allows low-potential detection of H2O2 with high sensitivity and fast response time. With the immobilization of GOD, a biosensor has been constructed. In phosphate buffer solutions (PBS, pH 7.0), nearly free interference determination of glucose has been realized at 0.4 V(vs. Ag/AgCl/3.0 M KCI) with a wide linear range from 2.0 x 10(-5) to 1.5 x 10(-2) M and a fast response time within 5s. The biosensor has been used to determine glucose in human serum samples and the results are satisfactory.  相似文献   

5.
2-Aminothiazole was electropolymerized by cyclic voltammetry (CV) on the multi-walled carbon nanotubes (MWCNTs) modified glassy carbon electrode (GCE) surface. Poly(2-aminothiazole)/MWCNTs/GCE was used for determination of copper ions. The anodic peak currents of copper ions evaluated by differential pulse stripping voltammetry (DPSV) are linear with the concentrations in the range from 1.0 x 10(-7) M to 2.0 x 10(-5) M with a linear coefficiency of 0.9985. The detection limit is 2.0 x 10(-9) M calculated for a signal-to-noise ratio of 3 (S/N = 3). The proposed method was applied successfully to the determination of copper ions in drinking water, and the recovery was 96%.  相似文献   

6.
A novel chemically modified electrode has been prepared on the basis of the attachment of multi-wall carbon nanotubes (MWNT) onto the surface of a glassy carbon electrode (GCE) in the presence of a hydrophobic surfactant, dihexadecyl phosphate (DHP). This MWNT film was characterized by transmission electron microscopy images (TEM) and scanning electron microscopy (SEM). The electrochemical behavior of tyrosine at the MWNT film coated GCE was examined and it is found that this MWNT-modified GCE greatly enhances the oxidation peak current of tyrosine. Effects of some important factors, including pH, scan rate and amount of modifier, on the oxidation process of tyrosine were investigated. When the signal to noise ratio (SNR) is 3, the detection limit is 1 x 10(-7) M. The low relative standard deviations of the detection of tyrosine in human morning urine (3.3%) and white wine (5.2%) suggest a good reproducibility of the modified electrode.  相似文献   

7.
A novel strategy for highly sensitive electrochemical detection of uric acid (UA) was proposed based on graphene quantum dots (GQDs), GQDs were introduced as a suitable substrate for enzyme immobilisation. Uric oxidase (UOx) was immobilised on GQDs modified glassy carbon electrode (GCE). Transmission electron microscope, scanning electron microscopy, cyclic voltammetry and electrochemical impedance spectroscopy techniques were used for characterising the electrochemical biosensor. The developed biosensor responds efficiently to UA presence over the concentration linear range 1–800 μM with the detection limit 0.3 μM. This novel biosensing platform based on UOx/GQDs electrode responded even more sensitively than that based on GCE modified by UOx alone. The inexpensive, reliable and sensitive sensing platform based on UOx/GQDs electrode provides wide potential applications in clinical.Inspec keywords: organic compounds, graphene devices, quantum dots, enzymes, biosensors, biochemistry, electrochemical electrodes, electrochemical sensors, transmission electron microscopy, scanning electron microscopy, voltammetry (chemical analysis), electrochemical impedance spectroscopy, nanomedicine, molecular biophysicsOther keywords: sensitive uric acid determination, graphene quantum dots, uric oxidase immobilisation, electrochemical detection, GQD, enzyme immobilisation, glassy carbon electrode, GCE, transmission electron microscope, scanning electron microscopy, cyclic voltammetry, electrochemical impedance spectroscopy, electrochemical biosensor, C  相似文献   

8.
A multiwall carbon nanotube-modified glassy carbon (GC) electrode was employed for the investigation of chloramphenicol (CAP) reduction. Carbon nanotube coating can greatly lower the overpotential of the electrochemical reduction of CAP and promote the electrode reaction. CAP undergoes an irreversible reduction process in phosphate buffer by the modified electrode. The reduction peak current (Ip) was significantly increased. Effects of some important factors, including pH, scan rate, and amount of modifier, on the determination of CAP were investigated. In the range of 3 x 10(-7) to 1.2 x 10(-5) M, the reduction peak current (Ip) has a good linear relationship with the concentration of CAP. When the signal-to-noise ratio is 3, the detection limit is 4.5 x 10(-8) M. The relative standard deviation of 10 measurements for 3 x 10(-6) M CAP is 5.3%, suggesting an excellent reproducibility of the modified electrode. Interfering experiments show that the modified electrode has excellent selectivity for the detection of CAP. The modified electrode was used to determine CAP in eyedrops, and the recoveries were approximately 100%.  相似文献   

9.
Chen J  Zhang J  Wang K  Lin X  Huang L  Chen G 《Analytical chemistry》2008,80(21):8028-8034
In this study, an electrochemical DNA biosensor was developed for detection of the breakpoint cluster region gene and the cellular abl (BCR/ABL) fusion gene in chronic myelogenous leukemia by using 18-mer locked, nucleic acid-modified, single-stranded DNA as the capture probe. The capture probe was covalently attached on the sulfonic-terminated aminobenzenesulfonic acid monolayer-modified glassy carbon electrode through the free amines of DNA bases based on the acyl chloride cross-linking reaction. The covalently immobilized capture probe could selectively hybridize with its target DNA to form double-stranded DNA (dsDNA) on the LNA/4-ABSA/GCE surface. Differential pulse voltammetry was used to monitor the hybridization reaction on the capture probe electrode. The decrease of the peak current of methylene blue, an electroactive indicator, was observed upon hybridization of the probe with the target DNA. The results indicated that, in pH 7.0 Tris-HCl buffer solution, the peak current was linear with the concentration of complementary strand in the range of 1.0 x 10 (-12)1.1 x 10 (-11) M with a detection limit of 9.4 x 10 (-13) M. This new method demonstrates its excellent specificity for single-base mismatch and complementary dsDNA after hybridization, and this probe has been used for assay of PCR real sample with satisfactory results.  相似文献   

10.
A single-wall carbon nanotubes (SWNT)-film coated glassy carbon electrode (GCE) was described for the determination of tryptophan. In pH 2.5 Na2HPO4-citric acid buffer, tryptophan yields a well-defined and very sensitive oxidation peak at about 1.08 V at the SWNT-film coated GCE. The oxidation peak current increases greatly and the peak potential shifts toward more negative direction at the SWNT-modified GCE in contrast to that at the bare GCE. Under optimized conditions, the oxidation peak current is proportional to the concentration of tryptophan over the range from 4 x 10(-8) to 1 x 10(-5) mol/L. The detection limit is 1 x 10(-8) mol/L at 3 min of accumulation. Using the proposed method, tryptophan in the human's blood serum samples was determined.  相似文献   

11.
J Wei  J Qiu  L Li  L Ren  X Zhang  J Chaudhuri  S Wang 《Nanotechnology》2012,23(33):335707
In this paper, a 'green' and safe hydrothermal method has been used to reduce graphene oxide and produce hemin modified graphene nanosheet (HGN) based electrochemical biosensors for the determination of l-tyrosine levels. The as-fabricated HGN biosensors were characterized by UV-visible absorption spectra, fluorescence spectra, Fourier transform infrared spectroscopy (FTIR) spectra and thermogravimetric analysis (TGA). The experimental results indicated that hemin was successfully immobilized on the reduced graphene oxide nanosheet (rGO) through π-π interaction. TEM images and EDX results further confirmed the attachment of hemin on the rGO nanosheet. Cyclic voltammetry tests were carried out for the bare glass carbon electrode (GCE), the rGO electrode (rGO/GCE), and the hemin-rGO electrode (HGN/GCE). The HGN/GCE based biosensor exhibits a tyrosine detection linear range from 5?×?10(-7)?M to 2?×?10(-5)?M with a detection limitation of 7.5?×?10(-8)?M at a signal-to-noise ratio of 3. The sensitivity of this biosensor is 133 times higher than that of the bare GCE. In comparison with other works, electroactive biosensors are easily fabricated, easily controlled and cost-effective. Moreover, the hemin-rGO based biosensors demonstrate higher stability, a broader detection linear range and better detection sensitivity. Study of the oxidation scheme reveals that the rGO enhances the electron transfer between the electrode and the hemin, and the existence of hemin groups effectively electrocatalyzes the oxidation of tyrosine. This study contributes to a widespread clinical application of nanomaterial based biosensor devices with a broader detection linear range, improved stability, enhanced sensitivity and reduced costs.  相似文献   

12.
Nano-porous hydroxyapatite (HAp) modified electrode was fabricated by simply electrodepositing HAp onto the glassy carbon electrode (GCE) from the electrolytes solution containing Ca(NO3)2 4H2O and NH4H2PO4, the resulting electrode (nano-HAp/GCE) was characterized with scanning electron microscopy (SEM). The electrochemical behavior of p-chlorophenol (p-CP) at nano-HAp/GCE was studied by cyclic voltammetry. The electrode displayed selective and enhanced electroanalytical response towards p-CP, obviously because p-CP is accumulated at the electrode. For the greater sensitivity, a semi-derivative technique was adopted to obtain the current signal. The results indicated that the nano-HAp/GCE exhibits substantial enhancement in electrochemical sensitivity for p-CP due to its large surface area and particular adsorbability. After accumulation of 4 min for p-CP on nano-HAp/GCE, the peak height was linearly related to the concentration of p-CP in the range of 1.0 x 10(-8) to 1.0 x 10(-7) mol L(-1). The detection limit was 4.0 x 10(-9) mol L-(1) at 3sigma level. Based on this, the modified electrode was successfully applied in water samples with low cost and high sensitivity.  相似文献   

13.
Wang J  Li M  Shi Z  Li N  Gu Z 《Analytical chemistry》2002,74(9):1993-1997
The electrochemistry of horse heart cytochrome c was studied by cyclic voltammetry at a glassy carbon electrode modified with single-wall carbon nanotubes (SWNTs). A pair of well-defined redox waves was obtained in cytochrome c aqueous solution at an activated SWNT film-modified electrode. The optimal conditions for activating the SWNT film-modified electrode has been determined. The electrode reaction of cytochrome c is a diffusion-controlled process. The peak current increases linearly with the concentration of cytochrome c in the range from 3.0 x 10(-5)-7.0 x 10(-4) M. The detection limit is 1.0 x 10(-5) M. The activated SWNT film was characterized by scanning electron microscopy. Furthermore, interaction of cytochrome c with adenine was characterized by electrochemical and spectral methods.  相似文献   

14.
In this work, reduced graphene oxide coated zinc oxide flower (ZnO–RGO) nanocomposite has been prepared via a simple one-pot hydrothermal synthesis method. The morphology and properties of the proposed ZnO–RGO were characterized using SEM, Raman and UV–VIS spectroscopy. Then, an ascorbic acid (AA) electrochemical sensor was prepared based on a glassy carbon electrode (GCE) modified with the ZnO–RGO nanocomposite. An advanced performance was recorded on the ZnO–RGO/GCE compared with that of the bare GCE, ZnO/GCE, and RGO/GCE. The proposed electrochemical sensor exhibited a wide linear detection from 5 μM to 2 mM with a low detection limit of 1.2 μM. Further, the proposed AA electrochemical sensor showed a good repeatability, reproducibility and stability.  相似文献   

15.
A cobalt(II) tetra-neopentyloxy phthalocyanine-multi-walled carbon nanotubes (CoTNPPc–MWNTs) composite was synthesized and characterized by UV–Vis spectra and transmission electron microscopy. The CoTNPPc–MWNTs glassy carbon electrode (CoTNPPc–MWNTs/GCE) was prepared by drop coating. The electrocatalytic performance of the chemically modified electrode was investigated for oxidation of ascorbic acid (AA). It was found that in phosphate buffer solution at pH = 6.60, the chemically modified electrode exhibited excellent electrocatalytic activity toward the oxidation of AA. The oxidation peak current increased linearly with the concentration of AA in the range of 10 μM–1.6 mM within the detection limit of 5 μM and low response time of 4 s.  相似文献   

16.
An amperometric glucose biosensor has been developed using DNA as a matrix of Glucose oxidase (GOx) at Prussian-blue (PB)-modified glassy carbon (GC) electrode. GC electrode was chemically modified by the PB. GOx was immobilized together with DNA at the working area of the PB-modified electrode by placing a drop of the mixture of DNA and GOx. The response of the biosensor for glucose was evaluated amperometrically. Upon immobilization of glucose oxidase with DNA, the biosensor showed rapid response toward the glucose. On the other hand, no significant response was obtained in the absence of DNA. Experimental conditions influencing the biosensor performance were optimized and assessed. This biosensor offered an excellent electrochemical response for glucose concentration in micro mol level with high sensitivity and selectivity and short response time. The levels of the relative standard deviation (RSDs), (<4%) for the entire analyses reflected a highly reproducible sensor performance. Through the use of optimized conditions, a linear relationship between current and glucose concentration was obtained up to 4 x 10(-4) M. In addition, this biosensor showed high reproducibility and stability.  相似文献   

17.
Two-dimensional (2D) titanium carbide (MXene) nanosheets exhibited excellent conductivity,flexibility,high volumetric capacity,hydrophilic surface,thermal stability,etc.So,it has been exploited in various applications.Herein,we report synthesis of mixed phase 2D MXene as a catalytic material for simultaneous detection of important biomolecules such as ascorbic acid (AA),dopamine (DA) and uric acid (UA),Crystalline structure,surface morphology and elemental composition of mixed phase titanium carbide (Ti-C-Tx) MXene (Tx =-F,-OH,or-O) nanosheets were confirmed by X-ray diffraction (XRD),Raman spectroscopy,high-resolution transmission electron microscopy (HR-TEM),high-resolution scanning electron microscopy (HR-SEM) and Energy-dispersive X-ray spectroscopy (EDS) mapping analysis.Furthermore,Ti-C-Tx modified glassy carbon electrode (GCE) was prepared and its electrochemical properties are studied by cyclic voltammetry (CV) and differential pulse voltammetry (DPV).It was found that Ti-C-Tx modified GCE (Ti-C-Tx/GCE) showed excellent electrocatalytic activity and separated oxidation peaks of important biomolecules such as AA (at 0.01 V),DA (at 0.21 V) and UA (at 0.33 V).Also,Ti-C-Tx/GCE sensor is enabled their simultaneous detection in physiological pH from 100 to 1000 μM for AA,0.5-50 μM for DA and 0.5-4 μM & 100-1500 μM for UA.The limit ofdetection's (LOD) was estimated as 4.6 μM,0.06 μM and 0.075 μM for AA,DA and UA,respectively.Moreover,real sample analysis indicated that spiked AA,DA and UA can be determined accurately by Ti-C-Tx/GCE with the recovery ratio in the range between 100.5%-103% in human urine samples.The proposed Ti-C-Tx modified electrode exhibited good stability,selectivity and reproducibility as an electrochemical sensor for the detection ofAA,DA and UA molecules.  相似文献   

18.
In the present work, we have demonstrated the fabrication of catechol (CC) biosensor based on reduced graphene oxide (rGO) decorated β-cyclodextrin (β-CD) nanosheet immobilized using nafion (Nf) on modified GCE (glassy carbon electrode). The rGO/β-CD nanocomposite is synthesized through sonochemical approach and characterized by spectral (UV–visible, FT-IR, and Raman), analytical techniques (XRD, SEM, SAED, mapping analysis, HR-TEM and EDX) and electrochemical studies. The rGO/β-CD/Nf modified GCE exhibit a prominent electrocatalytic activity towards selective and sensitive determination of CC than other modified electrodes. Besides, the electrochemical sensor was revealed an excellent current response for the determination of CC with wide linear ranges (0.1–0.7 µM), high sensitivity (19.1 µA µM-1cm2) and very low detection limit (LOD) 0.0012 µM. The excellent reproducibility, selectivity, stability, and sensitivity results are achieved for the determination of CC.  相似文献   

19.
Nanowires of poly-cobalt[tetrakis(o-aminophenyl)porphyrin] (PCoTAPPNW) were fabricated by electrochemical polymerization by the cyclic voltammetric method in anodic aluminum oxide membranes. A glassy carbon electrode (GCE) modified by PCoTAPPNW and single-walled carbon nanotubes (SWNT) without any binder was investigated with voltammetric methods in phosphate buffer saline (PBS) at pH 7.4. The PCoTAPPNW + SWNT/GCE exhibited strongly enhanced voltammetric and amperometric sensitivity towards hydrogen peroxide (H2O2), which shortened the response time (< 5 seconds), showed detection limit of 1.0 microM and enhanced the sensitivity for H2O2 detection with 194 microA mM(-1) cm(-2). The PCoTAPPNW + SWNT/GCE can be used to monitor H2O2 at very low concentration in physiological pH as an efficient electrochemical H2O2 sensor.  相似文献   

20.
在玻碳电极上修饰一层表面均匀的聚吡咯膜,然后利用钙钛矿和壳聚糖的复合膜来固定牛血红蛋白(Hb),制备出性能良好的过氧化氢生物传感器.采用循环伏安(CV)和扫描电镜对修饰电极进行了表征.该传感器对H2O2具有好的催化响应,且响应快.在优化的实验条件下,所制备的传感器对H2O2的线性范围为7.0×10-6~1.5×10-3mol/L,检测限为9.0×10-8mol/L.  相似文献   