首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 171 毫秒
1.
通过1个钢筋混凝土剪力墙和4个装配式空心模板剪力墙的拟静力试验,研究了剪力墙的抗震性能及竖向接缝构造对墙体受力性能的影响。试验结果表明,装配式空心模板剪力墙沿内部接缝出现宏观竖向裂缝,经历了整截面墙受力到墙柱组合体受力的过程,可防止脆性破坏,较钢筋混凝土剪力墙变形能力显著增强、受剪承载力降低;峰值荷载前沿竖向接缝两侧的相对变形将墙体分割为分缝剪力墙,提高了延性和耗能能力,降低了受剪承载力;竖向接缝处采用木板条补替部分混凝土可改善墙体的受力性能;按照强弯弱剪设计的墙体,水平接缝对墙体受力性能的影响可以忽略;装配式空心模板剪力墙的竖向接缝受力性能良好,可用于实际工程。  相似文献   

2.
通过1个钢筋混凝土剪力墙和4个装配式空心模板剪力墙的拟静力试验,研究了剪力墙的抗震性能及竖向接缝构造对墙体受力性能的影响。试验结果表明,装配式空心模板剪力墙沿内部接缝出现宏观竖向裂缝,经历了整截面墙受力到墙柱组合体受力的过程,可防止脆性破坏,较钢筋混凝土剪力墙变形能力显著增强、受剪承载力降低;峰值荷载前沿竖向接缝两侧的相对变形将墙体分割为分缝剪力墙,提高了延性和耗能能力,降低了受剪承载力;竖向接缝处采用木板条补替部分混凝土可改善墙体的受力性能;按照强弯弱剪设计的墙体,水平接缝对墙体受力性能的影响可以忽略;装配式空心模板剪力墙的竖向接缝受力性能良好,可用于实际工程。  相似文献   

3.
为研究榫卯式接缝预制混凝土剪力墙的受力性能,进行了1片现浇钢筋混凝土剪力墙和4片预制混凝土剪力墙在恒定轴力作用下的拟静力试验,分析了榫卯式接缝性能及墙体的抗震性能。结果表明:峰值荷载前,同一位置榫卯式接缝两侧水平钢筋应变基本相同,接缝两侧墙体基本无相对变形。破坏时水平、竖向相对变形仅为0.34、0.79mm,接缝连接可靠,保证了墙体的整体性能。榫卯式接缝预制混凝土剪力墙的受弯承载力、刚度与钢筋混凝土剪力墙基本相当,能够达到“等同现浇”的设计目标;破坏时墙体竖向接缝处混凝土剥落,减小了根部混凝土压溃区域面积,提高了墙体的变形能力;当顶点位移角为1/50时,预制混凝土剪力墙仍保持良好的竖向承载能力;提高边缘构件纵筋配筋率,墙体承载力提高,破坏区域更加集中在墙体的接缝处,延缓了根部混凝土的压溃。  相似文献   

4.
谷倩  黄蓉华  张延宾  邓庆  柯杨 《建筑结构》2021,51(21):73-80
为研究采用《装配式混凝土建筑技术标准》(GB/T 51231-2016)附录A规定的水平接缝连接方式的单面叠合剪力墙平面外受力性能,完成了1片带水平接缝单面叠合剪力墙和1片现浇剪力墙试件的平面外受力单调加载试验.结果表明:单面叠合剪力墙试件的裂缝分布形态与现浇剪力墙试件相同,均表现为典型的弯曲破坏特征;单面叠合剪力墙试件在平面外受力时的初始刚度、延性性能、极限承载力均明显高于现浇剪力墙试件,平面外刚度退化速度略大于现浇剪力墙试件;采用该水平接缝连接方式的竖向连接钢筋能有效传递钢筋应力;在平面外荷载作用下,单面叠合剪力墙的整体性保持完好,预制-后浇混凝土界面未发生剪切滑移破坏.在试验研究基础上,采用ABAQUS软件对试件进行有限元建模分析,计算结果与试验结果吻合良好;计算结果表明,随着轴压比增大,单面叠合剪力墙的平面外承载力明显增加,而延性明显降低;竖向连接钢筋搭接长度越短,平面外承载力越低.  相似文献   

5.
提出一种“螺栓-钢连接件-套筒”形式的全装配预制混凝土剪力墙水平接缝方案。为研究该水平接缝的工作性能,设计了普通剪力墙和采用全装配式水平接缝的预制混凝土剪力墙,完成了低周反复静力加载试验,利用有限元方法对其进行数值模拟,分析了全装配式水平接缝方案套筒布置与搭接钢筋直径对墙片水平受剪承载力的影响。研究结果表明:普通墙和预制墙的破坏形式均为受弯破坏,极限位移角相近,分别为1/43和1/45,预制墙水平受剪承载力比普通墙稍高,延性和耗能比普通墙略差。由钢筋破坏形态和应变结果可知,套筒能有效传递钢筋内力,水平接缝为墙片提供了可靠的竖向连接,采用全装配式水平接缝方案的预制混凝土剪力墙总体抗震性能良好。数值模拟结果与试验结果基本吻合,套筒布置与搭接钢筋直径对墙片水平受剪承载力具有明显影响,优化套筒布置与搭接钢筋直径可以进一步提高全装配式墙体的水平受剪承载能力。  相似文献   

6.
对1个现浇钢筋混凝土剪力墙试件和2个装配整体式剪力墙剪力墙试件进行拟静力试验,研究剪跨比为1.5的装配整体式剪力墙的抗震性能以及榫卯板构造对榫卯接缝的连接性能的影响.结果 表明:榫卯接缝整体性良好,接缝开裂时试件位移角远大于1/1000;装配整体式剪力墙的破坏区域主要集中在榫卯接缝处,峰值荷载时墙体根部混凝土基本完好,承载力低于现浇钢筋混凝土剪力墙,但刚度退化速率小于现浇钢筋混凝土剪力墙,变形能力、累计耗能大于现浇钢筋混凝土剪力墙,峰值荷载后装配整体式剪力墙进入墙柱组合体受力阶段,承载力下降减缓,位移角达到1/25时仍保持水平和竖向承载力;榫卯板横向凹槽底部与竖向孔洞内侧是否平齐对墙体承载力基本没有影响,但平齐构造可延缓榫卯接缝破坏,有助于提高墙体的刚度和耗能能力.  相似文献   

7.
对1个钢筋混凝土剪力墙试件、1个后浇带连接的预制混凝土剪力墙试件和1个榫卯接缝连接的装配整体式剪力墙试件开展拟静力试验研究,研究了不同构造接缝的连接性能及其对墙体受力性能的影响.结果 表明,榫卯接缝的连接性能较好,可保证墙体的整体性,对受弯承载力无不利影响;峰值荷载后,沿榫卯接缝的横向凹槽底部截面形成竖向裂缝,有助于提高墙体的变形能力,减小根部混凝土压溃区域;后浇带接缝剪力墙开裂较早且发展较快,对承载力影响较大,榫卯接缝的连接性能优于后浇带连接接缝.  相似文献   

8.
带接缝连接梁的预制混凝土剪力墙抗震性能试验研究   总被引:1,自引:0,他引:1  
采用钢筋混凝土接缝连接梁来实现预制墙体竖向钢筋的连续性连接。通过6个高宽比为1.7、不同截面高度和位置的接缝连接梁预制混凝土剪力墙的低周反复加载试验,分析了试件的破坏形态、顶点荷载-位移滞回曲线、承载力、变形能力、刚度退化等特性,并与整体现浇墙体进行对比。试验结果表明:预制墙体试件与整体现浇墙体试件的破坏模式、破坏形态基本相同,均为墙体角部混凝土压碎、钢筋拉断或屈曲;预制墙体试件的水平承载力相当,略低于现浇墙体,接缝连接梁的位置及截面高度对承载力有一定程度的影响;预制墙体试件的变形能力略小于现浇墙体试件,但极限位移角均超过1/100;接缝连接梁可以有效传递荷载。  相似文献   

9.
完成了6个带竖向接缝的预制混凝土空心模剪力墙试件在恒定轴力作用下的拟静力试验,研究了墙体的受弯性能以及竖向接缝的连接性能,明晰了墙体的破坏过程和破坏形态。试验结果表明:墙体破坏形态与钢筋混凝土剪力墙相似,破坏时墙体根部混凝土压溃、边缘构件纵筋压曲;部分墙体的破坏区域发展至中部墙板,预制混凝土与后浇混凝土剥离;竖向接缝构造合理、连接可靠,能够保证墙体的整体性能,对受弯性能基本无影响;试件的转角延性系数为4.35~12.54,具有良好的延性;提高边缘构件纵筋配筋率和轴压比,墙体的承载力提高,混凝土压溃面积增大;采用单排竖向插筋对墙体的受弯性能影响较小;GB 50010-2010《混凝土结构设计规范》的计算方法可用于计算空心模剪力墙试件的承载力,计算结果较为保守。  相似文献   

10.
通过在预制剪力墙底部预留混凝土后浇区,上、下层墙体竖向分布钢筋在此区域内搭接连接,在此区域外支腿范围内的纵向钢筋采用套筒灌浆连接,形成装配整体式剪力墙结构。为研究该类剪力墙的抗震性能,设计了5组共15片装配整体式足尺剪力墙,对其进行拟静力试验。研究表明:装配整体式剪力墙为典型的弯剪破坏模式;底部预留混凝土后浇区上方的水平接缝和墙底水平接缝开裂并贯通,在试验过程中竖向接缝未开裂,当轴压比较大或剪跨比较小时,底部后浇区角部混凝土会产生压溃或剥落现象;装配整体式剪力墙的破坏模式以及滞回特征、承载力、延性、刚度退化情况等指标与对应的现浇试件基本一致,水平承载力相差不超过5.7%,位移延性系数不低于4.1,极限层间位移角均在1/87以上,呈现良好的整体性能和抗震性能。  相似文献   

11.
预制空心板剪力墙结构是一种新型装配式剪力墙结构。为研究预制空心板剪力墙的抗震性能、同层相邻预制空心板的整体性、采用水平插筋间接搭接连接的水平钢筋的抗剪作用、灌孔边缘构件的有效性,完成了6个轴压比设计值为0.3、剪跨比为1.61~2.42、压弯破坏为主的空心板剪力墙试件的拟静力试验。试验结果表明:试件的破坏形态均为压弯破坏,实现了预期的强剪弱弯设计目标,水平钢筋能有效抵抗水平剪力;试件的水平力-位移滞回曲线比较饱满,极限位移角为1/72~1/38,可按现浇剪力墙计算偏心受压空心板剪力墙的受压承载力;同层相邻空心板之间竖向接缝的开裂宽度小,接缝两侧构件竖向错动小,斜裂缝在竖向接缝处连续,直接拼接连接、后浇竖向拼缝连接都能使空心板成为整体;采用灌孔边缘构件的空心板剪力墙,其抗震性能满足现行规范要求。  相似文献   

12.
Precast shear walls, as an environmentally friendly building system, have been vigorously developed in China. There are many vertical and horizontal joints on precast reinforced concrete shear wall system, which certainly have a significant effect on seismic performance of structures. In this paper, 3 L‐shaped precast reinforced concrete shear walls that were assembled by 2 precast parts through a middle cast‐in‐situ joint and a compared 1 completely cast‐in‐situ were tested under low frequency cyclic loading to investigate their seismic behaviors. The vertical distributed reinforcements in the three precast specimens were equivalently spliced by grouting sleeves arranged along the center line of the wall, and the horizontal reinforcements were directly anchored in cast‐in‐situ joints. The experimental results, including failure mode, yielding load and displacement, skeleton curve, energy dissipation, stiffness degradation, ductility, and so forth were presented in the paper. The results show that the precast specimens have similar bearing capacity whereas much better deformation capacity and ductility compared to the cast‐in‐situ specimen. Additionally, the experimental results of ultimate shear capacity of specimens were also compared with that of the calculation results. These results indicate that the tested precast shear walls have good and reliable seismic performance and can be used as a structural member in engineering projects.  相似文献   

13.
为了研究采用钢板焊接连接的带水平接缝预制装配式钢筋混凝土剪力墙的抗震性能,设计了4个装配式钢筋混凝土剪力墙足尺试件并进行低周往复水平荷载试验,研究参数包括连接钢板厚度、侧向钢板设置和轴压比。结果表明:各试件均为压弯破坏,水平承载力在186~288kN之间,极限位移在25.74~29.37mm之间,滞回曲线为饱满的弓形,延性和耗能能力较好,刚度退化较慢;在连接钢板满足强度要求前提下,增大连接钢板厚度、增加侧向钢板对剪力墙的延性、刚度、承载能力和耗能能力影响较小;提高轴压比可以明显提高装配式剪力墙的刚度和承载能力,但会降低其耗能能力。采用ABAQUS有限元软件对装配式剪力墙抗震性能进行分析,所建立的有限元模型可以较好地模拟装配式剪力墙的受力性能。通过对比采用规范公式计算的承载力与试验承载力,表明可以采用JGJ 3—2010《高层建筑混凝土结构技术规程》中的公式计算文中装配式剪力墙的承载力,并给出了连接钢板的计算方法。  相似文献   

14.
介绍了3片剪跨比为2.13的钢筋混凝土剪力墙试件在特定轴压比下的拟静力试验,其中1片为现浇试件CW-1,另外2片为采用预制墙板,两端暗柱与水平齿槽现浇混凝土在墙体底部实现与之连接的预制试件。预制试件的主要区别是一片在齿槽内不设竖向分布钢筋的试件PW-1,另一片齿槽内竖向分布钢筋自由搭接的试件PW-2。试验结果表明:通过齿槽连接的预制墙体,其破坏形态与现浇试件基本相同,墙体两端暗柱底部混凝土受压破坏、竖向钢筋受拉屈服;预制试件的极限位移角为1/48~1/53;齿槽式连接能够保证剪力墙在正常工作状态下的受剪承载力;预制试件PW-2的滞回曲线饱满,受剪承载力与现浇试件相当,其延性性能满足抗震要求,齿槽区域墙体竖向分布钢筋自由搭接的连接方式在一定轴压比下可行,经进一步的试验和分析研究后可推广应用。  相似文献   

15.
为研究带水平接缝的装配整体式双面叠合剪力墙的平面外受力性能,完成了1片双面叠合剪力墙和1片现浇剪力墙足尺试件的平面外静力加载试验和有限元参数分析,对比分析了各试件的破坏形态、荷载-位移曲线、刚度退化特征和水平接缝处竖向连接钢筋的传力性能,提出了双面叠合剪力墙平面外受弯承载力和水平接缝截面受剪承载力的计算方法。结果表明:双面叠合剪力墙与现浇剪力墙试件的破坏形态基本相同,均为平面外弯曲破坏,与现浇剪力墙相比,双面叠合剪力墙试件的初始裂缝出现在底部水平接缝处,随后在墙面出现并逐级向上发展,表现出良好的延性破坏特征; 双面叠合剪力墙试件具有较高的平面外受弯承载力和变形能力,其初始刚度、极限承载力、平面外位移延性系数均大于现浇剪力墙试件; 双面叠合剪力墙试件的有限元计算结果与试验结果吻合良好; 随着轴压比增加,叠合剪力墙平面外承载力明显增加,但延性明显降低; 高厚比越小,叠合剪力墙平面外承载力越高,而对延性则影响不大; 提出的受弯承载力计算结果与试验结果吻合较好,可用于指导工程实践。  相似文献   

16.
为了研究免模剪力墙的抗震性能,完成了1片免模保温剪力墙、1片免模非保温剪力墙和1片现浇剪力墙的拟静力试验,对比分析了试件的承载能力、滞回曲线、骨架曲线、刚度退化曲线、延性性能、耗能能力等抗震指标,并对免模剪力墙的整体性进行了分析。结果表明:免模剪力墙与现浇剪力墙的受力过程、破坏形态基本相同,抗震性能指标相近,具有与现浇剪力墙相近的抗震性能;与现浇剪力墙相比,免模剪力墙中预制模板和保温层的存在一定程度上削弱了墙体的工作性能,但是影响有限;在工作过程中,免模剪力墙预制模板平面内和平面外的相对位移均较小,没有出现较大范围预制模板与现浇区分离的现象,抗剪连接件和自然粗糙面的构造措施能够较好地保证免模剪力墙各组成部分的协同工作能力和墙体的整体性。  相似文献   

17.
为提高双层钢板混凝土组合剪力墙的施工效率,提出了设置竖向通缝、水平缝通过螺栓连接的装配式双层钢板-混凝土组合剪力墙,并对6个缩尺比为1∶2的组合剪力墙进行了拟静力试验,得到其破坏形态、滞回性能、应变、刚度和承载力退化、耗能能力等试验结果,分析设置竖向通缝、不同形式水平缝螺栓连接等构造对组合剪力墙抗震性能的影响。试验结果表明:该装配式组合剪力墙抗震性能良好;相比于边缘构件和墙体焊接的组合剪力墙,设置竖向通缝的组合剪力墙承载力降低约25%,但延性提高;采用合理的水平缝螺栓连接构造,可保证连接处应力的有效传递。与一字形和锯齿形缝组合剪力墙相比,企口形缝组合剪力墙的承载力较低。  相似文献   

18.
装配式RC梁柱塑性可控钢质节点由钢制节点模块、上下柱模块、梁模块以及阻尼器模块装配组成。通过对该装配式节点及现浇节点进行拟静力加载足尺试验,并采用ABAQUS软件进行有限元数值模拟,研究装配式节点承载力、滞回耗能、延性以及承载力退化等抗震性能指标。试验及有限元模拟结果表明:相较于现浇节点,装配式RC梁柱塑性可控钢质节点的滞回曲线更饱满,耗能能力更强,延性更好,承载能力退化更缓慢;该装配式节点的极限承载力低于现浇节点,但能有效控制混凝土损伤,避免梁端混凝土发生弯曲破坏,实现梁端“塑性可控”;建立的有限元模型可较准确地预测同种装配式节点的承载能力和变形能力。  相似文献   

19.
双面叠合剪力墙水平连接节点是传递竖向荷载和水平剪力的关键部位,其水平节点连接钢筋是“间接搭接”的形式。通过6个双面叠合剪力墙水平连接节点和2个现浇节点在竖向荷载和循环剪切荷载作用下的试验,研究双面叠合剪力墙水平连接节点和现浇节点的滞回特性、位移延性系数、刚度退化、承载力退化以及耗能特性。试验结果表明,双面叠合剪力墙水平连接节点的水平裂缝出现在灌浆层和上下墙体的交界面,双面叠合剪力墙水平连接节点的抗剪承载力和现浇节点较为接近,各项抗震性能指标较为接近。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号