共查询到19条相似文献,搜索用时 78 毫秒
1.
2.
3.
4.
5.
6.
提出将电阻层析成像(ERT)技术应用于冰水两相流相含率、相分布等特征参数的测量,并设计了ERT测量系统,研究了基于图像的相含率计算方法.阐述了ERT系统的工作原理,提出了16电极ERT系统的设计方案.介绍了线性反投影图像重构算法(LBP);并结合数字图像处理技术,提出了截面相含率的计算方法.最后,通过一组实验验证了电阻层析成像技术应用于冰水两相流检测的可行性.实验结果表明:通过ERT系统可以获得管道内冰柱在水中的位置以及实时运动结果,直观反映冰水两相介质的相分布;另外,通过ERT系统可以近似地真实反映冰柱的相对大小,两次截面相含率测量误差分别为6%与2.8%.研究表明,ERT技术可以实现冰水两相流的实时在线监测,而且具有良好的测量准确度. 相似文献
7.
8.
电容层析成像(Electrical Capacitance Tomography,ECT)技术是目前最具发展前景的多相流参数检测方法,它可重建两相流在其流经管道横截面上的分布图像.对12电极的电容传感器进行了数学描述,建立了电容敏感场分布的数学模型及其有限元模型,分析了敏感场的算法,利用有限元法实现了敏感场的仿真,并且研究了敏感场分布的规律.在此基础上利用灰度图像重建的方法重现出不同流体分布状态下油管横截面的灰度图像,为两相流在线检测仪器的设计提供了理论依据. 相似文献
9.
10.
11.
Visualization of flow pattern in thermosyphon by ECT 总被引:3,自引:0,他引:3
Visualization of the liquid flow in a two-phase closed thermosyphon (TPCT) is studied using electrical capacitance tomography (ECT) with optimal step lengths for iterative image reconstruction algorithm. Measurements are made under a range of heating rates. Experimental results demonstrated ECT’s capability of reconstructing images of thin films of the order of μm in thickness. Results are compared with the established theory and agreements and discrepancies are observed for different thresholds. ECT images of the liquid distributions in the TPCT show clear dependence on the variation of working conditions, which reveals the potential of ECT as an advanced technique for monitoring the operation of TPCT. 相似文献
12.
13.
Compared to general room-temperature fluids, the characteristics of cryogenic fluids, as well as the complexity of the cryogenic environment, pose greater challenges for reconstruction algorithms for Electrical Capacitance Tomography (ECT). Based on deep learning, a hybrid model is proposed for cryogenic fluid ECT image reconstruction in this study. The multi-head self-attention mechanism is employed to initially establish the mapping of capacitance to the image, and then an improved U-net-like convolution neural network is presented to perform deep feature extraction and image reconstruction. The ConvNeXt block is adopted for multi-level feature extraction, and a separate downsampling layer is used to replace the pooling layer. A dataset covering a variety of two-phase typical flow patterns and irregular flow patterns is built for training. A capacitance vector and an image of phase distribution are included in each sample. Extensive numerical experiments are carried out on the trained model. The results show that the model can accurately predict phase distribution and produce a clear interface. Finally, the model was successfully applied in cryogenic experiment to obtain the phase distribution image of liquid nitrogen stratified flow. 相似文献
14.
Abstract In this paper, a movable electrical impedance tomography (MEIT) system is introduced to reduce the noise of electrical impedance tomography. This moving scheme could yield more independent measurements and reconstruct improved impedance images. After averaging the entire reconstructed image, we could improve the image quality substantially. The experiment result shows a quality improvement compared with the measuring systems without moving scheme. This preliminary work provides a feasibility to reduce the noise of electrical impedance tomography by a moving electrode scheme. 相似文献
15.
16.
17.
18.